0% found this document useful (0 votes)
142 views5 pages

Fixed Column Base Design: Eneral

This document provides details on the design of a fixed column base connection according to Eurocode standards. Key details include the column and base plate dimensions and materials, anchor bolt arrangement and properties, and loads applied. Analysis is shown for compression resistance of the concrete, bearing capacity of the anchor bolts, and shear checks for the connection. All capacity checks show the connection design is verified against the loads applied.

Uploaded by

amanpreet_ahuja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
142 views5 pages

Fixed Column Base Design: Eneral

This document provides details on the design of a fixed column base connection according to Eurocode standards. Key details include the column and base plate dimensions and materials, anchor bolt arrangement and properties, and loads applied. Analysis is shown for compression resistance of the concrete, bearing capacity of the anchor bolts, and shear checks for the connection. All capacity checks show the connection design is verified against the loads applied.

Uploaded by

amanpreet_ahuja
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Page 1 of 5

Autodesk Robot Structural Analysis Professional 2015

Fixed column base design


Eurocode 3: EN 1993-1-8:2005/AC:2009 + CEB Design Guide:
Ratio
Design of fastenings in concrete 0.71

GENERAL
Connection no.: 2
Connection name: Fixed column base

GEOMETRY
COLUMN
Section: SHSH 250x250x12.5
Lc = 4.00 [m] Column length
= 0.0 [Deg] Inclination angle
hc = 250 [mm] Height of column section
bfc = 250 [mm] Width of column section
twc = 13 [mm] Thickness of the web of column section
tfc = 13 [mm] Thickness of the flange of column section
rc = 13 [mm] Radius of column section fillet
Ac = 11700 [mm2] Cross-sectional area of a column
Iyc = 109150000 [mm4] Moment of inertia of the column section
Material: S355
fyc = 355.00 [MPa] Resistance
fuc = 490.00 [MPa] Yield strength of a material

COLUMN BASE
lpd = 500 [mm] Length
bpd = 500 [mm] Width

mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 2 of 5

tpd = 25 [mm] Thickness


Material: S355
fypd = 355.00 [MPa] Resistance
fupd = 490.00 [MPa] Yield strength of a material

ANCHORAGE
The shear plane passes through the UNTHREADED portion of the bolt.
Class = 8.8 Anchor class
fyb = 640.00 [MPa] Yield strength of the anchor material
fub = 800.00 [MPa] Tensile strength of the anchor material
d= 30 [mm] Bolt diameter
As = 561 [mm2] Effective section area of a bolt
Av = 707 [mm2] Area of bolt section
nH = 4 Number of bolt columns
nV = 4 Number of bolt rows
Horizontal spacing eHi = 130;130 [mm]
Vertical spacing eVi = 130;130 [mm]

Anchor dimensions
L1 = 50 [mm]
L2 = 600 [mm]
L3 = 50 [mm]

Anchor plate
lp = 130 [mm] Length
bp = 130 [mm] Width
tp = 10 [mm] Thickness
Material: S355
fy = 355.00 [MPa] Resistance

Washer
lwd = 60 [mm] Length
bwd = 60 [mm] Width
twd = 8 [mm] Thickness

MATERIAL FACTORS
M0
= 1.00 Partial safety factor
M2 = 1.25 Partial safety factor
C = 1.50 Partial safety factor

SPREAD FOOTING
L= 900 [mm] Spread footing length
B= 1200 [mm] Spread footing width
H= 1200 [mm] Spread footing height

Concrete
Class C40
fck = 40.00 [MPa] Characteristic resistance for compression

Grout layer
tg = 25 [mm] Thickness of leveling layer (grout)
fck,g = 40.00 [MPa] Characteristic resistance for compression
Cf,d = 0.20 Coeff. of friction between the base plate and concrete

mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 3 of 5

WELDS
ap = 8 [mm] Footing plate of the column base

LOADS
Case: Manual calculations.

Nj,Ed = -1200.00 [kN] Axial force


Vj,Ed,y = 550.00 [kN] Shear force
Vj,Ed,z = 580.00 [kN] Shear force

RESULTS

COMPRESSION ZONE
COMPRESSION OF CONCRETE
fcd = 26.67 [MPa] Design compressive resistance EN 1992-1:[3.1.6.(1)]
fj = 36.95 [MPa] Design bearing resistance under the base plate [6.2.5.(7)]
c = tp (fyp/(3*fj* M0))
c= 45 [mm] Additional width of the bearing pressure zone [6.2.5.(4)]
beff = 102 [mm] Effective width of the bearing pressure zone under the flange [6.2.5.(3)]
leff = 339 [mm] Effective length of the bearing pressure zone under the flange [6.2.5.(3)]
Ac0 = 34619 [mm2]
Area of the joint between the base plate and the foundation EN 1992-1:[6.7.(3)]
Ac1 = 311572 [mm2] Maximum design area of load distribution EN 1992-1:[6.7.(3)]
Frdu = Ac0*fcd* (Ac1/Ac0) ≤ 3*Ac0*fcd
Frdu = 2769.53 [kN] Bearing resistance of concrete EN 1992-1:[6.7.(3)]

j
= 0.67 Reduction factor for compression [6.2.5.(7)]
fjd = j*Frdu/(beff*leff)
fjd = 53.33 [MPa] Design bearing resistance [6.2.5.(7)]

Ac,n = 96879 [mm2] Bearing area for compression [6.2.8.2.(1)]


Fc,Rd,i = AC,i*fjd
Fc,Rd,n = 5166.86 [kN] Bearing resistance of concrete for compression [6.2.8.2.(1)]

RESISTANCES OF SPREAD FOOTING IN THE COMPRESSION ZONE


Nj,Rd = Fc,Rd,n
Nj,Rd = 5166.86 [kN] Resistance of a spread footing for axial compression [6.2.8.2.(1)]

CONNECTION CAPACITY CHECK


Nj,Ed / Nj,Rd ≤ 1,0 (6.24) 0.23 < 1.00 verified (0.23)

SHEAR
BEARING PRESSURE OF AN ANCHOR BOLT ONTO THE BASE PLATE
Shear force Vj,Ed,y

d,y = 0.57 Coeff. taking account of the bolt position - in the direction of shear [Table 3.4]
b,y = 0.57 Coeff. for resistance calculation F1,vb,Rd [Table 3.4]

mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 4 of 5

k1,y = 2.50 Coeff. taking account of the bolt position - perpendicularly to the direction of shear [Table 3.4]
F1,vb,Rd,y = k1,y* b,y*fup*d*tp / M2
F1,vb,Rd,y = 421.09 [kN] Resistance of an anchor bolt for bearing pressure onto the base plate [6.2.2.(7)]

Shear force Vj,Ed,z

d,z
= 0.57 Coeff. taking account of the bolt position - in the direction of shear [Table 3.4]
=
b,z 0.57
Coeff. for resistance calculation F1,vb,Rd [Table 3.4]
k1,z = 2.50 Coeff. taking account of the bolt position - perpendicularly to the direction of shear [Table 3.4]
F1,vb,Rd,z = k1,z* b,z*fup*d*tp / M2
F1,vb,Rd,z = 421.09 [kN] Resistance of an anchor bolt for bearing pressure onto the base plate [6.2.2.(7)]

SHEAR OF AN ANCHOR BOLT


b= 0.25 Coeff. for resistance calculation F2,vb,Rd [6.2.2.(7)]
Avb = 707 2 Area of bolt section [6.2.2.(7)]
[mm ]
fub = 800.00 [MPa] Tensile strength of the anchor material [6.2.2.(7)]
M2
= 1.25 Partial safety factor [6.2.2.(7)]
F2,vb,Rd = b*fub*Avb/ M2
F2,vb,Rd = 112.19 [kN] Shear resistance of a bolt - without lever arm [6.2.2.(7)]

SPLITTING RESISTANCE
Cf,d = 0.20 Coeff. of friction between the base plate and concrete [6.2.2.(6)]
Nc,Ed = 1200.00 [kN] Compressive force [6.2.2.(6)]
Ff,Rd = Cf,d*Nc,Ed
Ff,Rd = 240.00 [kN] Slip resistance [6.2.2.(6)]

SHEAR CHECK

Vj,Rd,y = nb*min(F1,vb,Rd,y, F2,vb,Rd) + Ff,Rd


Vj,Rd,y = 1586.31 [kN] Connection resistance for shear CEB [9.3.1]
Vj,Ed,y / Vj,Rd,y ≤ 1,0 0.35 < 1.00 verified (0.35)

Vj,Rd,z = nb*min(F1,vb,Rd,z, F2,vb,Rd) + Ff,Rd


Vj,Rd,z = 1586.31 [kN] Connection resistance for shear CEB [9.3.1]
Vj,Ed,z / Vj,Rd,z ≤ 1,0 0.37 < 1.00 verified (0.37)

Vj,Ed,y / Vj,Rd,y + Vj,Ed,z / Vj,Rd,z ≤ 1,0 0.71 < 1.00 verified (0.71)

WELDS BETWEEN THE COLUMN AND THE BASE PLATE


= 79.55 [MPa] Normal stress in a weld [4.5.3.(7)]
= 79.55 [MPa] Perpendicular tangent stress [4.5.3.(7)]
= 137.50 [MPa] Tangent stress parallel to Vj,Ed,y [4.5.3.(7)]
yII

zII = 145.00 [MPa] Tangent stress parallel to Vj,Ed,z [4.5.3.(7)]


W= 0.90 Resistance-dependent coefficient [4.5.3.(7)]
/ (0.9*fu/ M2)) ≤ 1.0 (4.1) 0.23 < 1.00 verified (0.23)
2
( + 3.0 ( yII2 + 2
)) / (fu/( W* M2))) ≤ 1.0 (4.1) 0.66 < 1.00 verified (0.66)
2
( + 3.0 ( zII2 + 2
)) / (fu/( W* M2))) ≤ 1.0 (4.1) 0.68 < 1.00 verified (0.68)

WEAKEST COMPONENT:
ANCHOR BOLT - SHEAR - WITH LEVER ARM

mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015
Page 5 of 5

Connection conforms to the code Ratio 0.71

mhtml:file://C:\Users\Monica.rodriguez\Documents\Autodesk\Output\ra_res.mht 26/11/2015