Version: A.5: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Bao'an District, Shenzhen, Guangdong, China
Version: A.5: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Bao'an District, Shenzhen, Guangdong, China
Version: A.5: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Bao'an District, Shenzhen, Guangdong, China
TEST REPORT
IEC 62133: 2012
Secondary cells and batteries containing alkaline or other non-acid electrolytes
Safety requirements for portable sealed secondary cells, and for batteries made
from them, for use in portable applications
Address ..................................................................... :
Manufacturer’s name ............................................. :
Address ..................................................................... :
Test specification :
This test report is specially limited to the above client company and product model only, It may not
be duplicated without prior written consent of Shenzhen TCT Testing Technology Co., Ltd.
Page 1 of 23
This report shall not be reproduced except in full, without the written approval of Shenzhen TCT Testing Technology Co., Ltd.
Report No. TCT170814B012
Summary of testing:
Tests performed (name of test and test Testing location:
clause): Shenzhen TCT Testing Technology Co., Ltd.
cl.5.6.2 Design recommendation(Lithium system);
1B/F., Building 1, Yibaolai Industrial Park, Qiaotou,
cl.8.1 Charging procedure for test purposes (for Fuyong, Bao’an District, Shenzhen, Guangdong, China
Cells and Pack);
cl.8.2.1 Continuous charging at constant voltage
(Cells);
cl.8.3.1 External short circuit (Cells);
cl.8.3.2 External short circuit (Battery);
cl.8.3.3 Free fall (for Cells and Pack);
cl.8.3.4 Thermal abuse (Cells);
cl.8.3.5 Crush (Cells);
cl.8.3.6 Over-charging of battery;
cl.8.3.7 Forced discharge (Cells);
cl.8.3.8 Transport tests (Cells);
The electrolyte type of this cell doesn’t belong to
polymer, and the applicant declares that this cell
isn’t to be sold in France, Japan, Republic of
Korea and Switzerland.
Tests are made with the number of cells and
batteries specified in IEC 62133: 2012 (Second
Edition) Table 2.
Summary of compliance with National Differences:
Page 2 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Recommend charging method declared by the Charging the battery with 115mA constant current
manufacturer.................................................................. : until 4.2V and then constant voltage until charging
current reduces to 4.6mA at ambient 20°C±5°C.
Testing.............................................................................. :
General remarks:
The test results presented in this report relate only to the object tested,
This report shall not be reproduced, except in full, without the written approval of the issuing testing
laboratory,
“(CXX #)” refers to sample number of cells, “X” is 0~9;
“(BXX #)” refers to sample number of cells, “X” is 0~9;
“(see below table)” refers to a table appended to the report.
Page 3 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
The main features of the cell in the battery pack are shown as below (clause 8.1.1):
The main features of the cell in the battery pack are shown as below (clause 8.1.2):
Taper-off
Upper limit Lower charge Upper charge
Model current
charge voltage temperature temperature
(0,05 It A)
The main features of the battery pack are shown as below (clause 8.1.1):
Nominal Nominal Maximum Maximum Maximum
Nominal Nominal Cut-off
Model Charge Discharge Charge Discharge Charge
capacity voltage Voltage
Current Current Current Current Voltage
The main features of the battery pack are shown as below (clause 8.1.2):
Taper-off
Upper limit Lower charge Upper charge
Model current
charge voltage temperature temperature
(0,05 It A)
Construction:
Page 4 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Circuit diagram:
Page 5 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 6 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 7 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 8 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 9 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 10 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 11 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
10 Marking P
10.1 Cell marking N/A
Cells marked as specified in the applicable cell The final product is battery. N/A
standards: IEC 61951-1, IEC 61951-2 or IEC 61960.
10.2 Battery marking P
Batteries marked in accordance with the The battery is marked in P
requirements for the cells from which they are accordance with IEC 61960,
assembled. See page 4.
Batteries marked with an appropriate caution N/A
statement.
10.3 Other information P
Storage and disposal instructions marked on or Information for storage P
supplied with the battery. instructions mentioned in
manufacturer’s specifications.
Recommended charging instructions marked on or Information for recommended P
supplied with the battery. charging instructions
mentioned in manufacturer’s
specifications.
11 Packaging P
The materials and packaging design are chosen so P
as to prevent the development of unintentional
electrical conduction, corrosion of the terminals and
ingress of environmental contaminants.
Page 12 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Annex A Charging range of secondary lithium ion cells for safe use P
A.1 General P
A.2 Safety of lithium-ion secondary battery Complied. P
A.3 Consideration on charging voltage Complied. P
A.3.1 General P
A.3.2 Upper limit charging voltage 4.25V applied. P
A.3.2.1 General P
A.3.2.2 Explanation of safety viewpoint N/A
A.3.2.3 Safety requirements, when different upper limit 4.25V applied. N/A
charging voltage is applied
A.4 Consideration of temperature and charging current P
A.4.1 General P
A.4.2 Recommended temperature range See A.4.2.2. P
A.4.2.1 General N/A
A.4.2.2 Safety consideration when a different recommended Charging temperature range N/A
temperature range is applied declared by client is: 10-45C
A.4.3 High temperature range Not higher than the N/A
temperature specific in this
standard.
A.4.3.1 General N/A
A.4.3.2 Explanation of safety viewpoint N/A
A.4.3.3 Safety considerations when specifying charging N/A
conditions in high temperature range
A.4.3.4 Safety consideration when specifying new upper N/A
limit in high temperature range
A.4.4 Low temperature range Not lower than the N/A
temperature specific in this
standard.
A.4.4.1 General N/A
A.4.4.2 Explanation of safety viewpoint N/A
A.4.4.3 Safety considerations, when specifying charging N/A
conditions in low temperature range
A.4.4.4 Safety considerations when specifying a new lower N/A
limit in the low temperature range
A.4.5 Scope of the application of charging current P
A.5 Sample preparation N/A
A.5.1 General N/A
A.5.2 Insertion procedure for nickel particle to generate N/A
internal short
Page 13 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 14 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 15 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Page 16 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
8.3.2 TABLE: External short circuit (battery) P
Model Ambient, (C) OCV at start of Resistance of Maximum case Results
test, (Vdc) circuit, (m) temperature
rise T, (C)
Samples charged at charging temperature upper limit (45C)
B1# 55.0 4.21 75 55.3 P
B2# 55.0 4.21 76 55.4 P
B3# 55.0 4.20 77 55.5 P
B4# 55.0 4.20 76 55.5 P
B5# 55.0 4.21 77 55.2 P
Samples charged at charging temperature lower limit (10C)
B6# 55.0 4.16 78 55.4 P
B7# 55.0 4.17 76 55.3 P
B8# 55.0 4.17 76 55.2 P
B9# 55.0 4.17 77 55.5 P
B10# 55.0 4.16 75 55.3 P
Supplementary information:
- No fire
- No explosion
Page 17 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
8.3.6 TABLE: Over-charging of battery P
Constant charging current (A).....................................: 0.46
Supply voltage (Vdc)......................................................: 5.0
Model OCV before Resistance of Maximum outer Results
charging, (Vdc) circuit, (m) casing temperature,
(C)
B1# 3.31 15.2 30.4 P
B2# 3.32 15.3 29.6 P
B3# 3.32 15.4 28.7 P
B4# 3.31 14.9 30.3 P
B5# 3.31 15.2 29.5 P
Supplementary information:
- No fire
- No explosion
Page 18 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
8.3.8 T-5 TABLE: External short circuit (cells) P
Model Ambient, (C) OCV at start of Resistance of Maximum case Results
test, (Vdc) circuit, (m) temperature
rise T, (C)
C1# 55.0 4.18 75 118.5 P
C2# 55.0 4.17 77 117.3 P
C3# 55.0 4.18 78 113.4 P
C4# 55.0 4.17 76 119.8 P
C5# 55.0 4.17 78 117.7 P
C6# 55.0 4.17 78 118.9 P
C7# 55.0 4.18 77 114.6 P
C8# 55.0 4.17 78 115.7 P
C9# 55.0 4.18 76 122.6 P
C10# 55.0 4.18 76 116.7 P
Supplementary information:
The external short-circuit test of 10 pcs samples performed after the test of Altitude, Thermal cycling,
Vibration and Shock in sequence.
- No excessive temperature rise, no rupture, no explosion and no fire
Supplementary information:
1)
Identify one of the following:
1: Nickel particle inserted between positive and negative (active material) coated area.
2: Nickel particle inserted between positive aluminium foil and negative active material coated area.
- No fire
Page 19 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Attachment 1
Photo Documentation
Page 20 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Photo Documentation
Page 21 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Photo Documentation
Page 22 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Photo Documentation
Page 23 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Test Report
Report No. : TCT170823C004 Date : Aug. 25, 2017 Page No.: 1 of 3
Applicant:
Address:
The following sample was submitted and identified by/on behalf of the client as:
Sample Name: Li-ion Battery
Model No.: 503040
Sample Received Date: 2017.08.23
Testing Period: 2017.08.23—2017.08.25
Test Requested: Accordance with Directive 2006/66/EC, to determine the Lead (Pb), Cadmium
(Cd), Mercury (Hg) contents of the submitted sample(s).
Test Method: Please refer to the following page(s).
Test Result(s): Please refer to the following page(s).
Conclusion: Test results of submitted sample(s) comply with the limit set by Directive
2006/66/EC and its amendment 2013/56/EU.
Test Results:
Test Process:
Remark:This report is considered invalidated without the Special Seal for Inspection of the TCT. This
report shall not be altered, increased or deleted. The results shown in this test report refer only to the
sample(s) tested. Without written approval of TCT, this test report shall not be copied except in full and
published as advertisement.