Version: A.5: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Bao'an District, Shenzhen, Guangdong, China

Download as pdf or txt
Download as pdf or txt
You are on page 1of 26

Version: A.

TEST REPORT
IEC 62133: 2012
Secondary cells and batteries containing alkaline or other non-acid electrolytes
Safety requirements for portable sealed secondary cells, and for batteries made
from them, for use in portable applications

Report Number......................................................... : TCT170814B012

Date of issue .............................................................: 2017-08-28

Total number of pages ...........................................: 23 Pages.

Tested by (name + signature) .............................. : Curry Shao

Inspected by (name + signature) ........................ : Carol Xiong

Approved by (name + signature) ........................ : Tomsin

Testing laboratory ...................................................: Shenzhen TCT Testing Technology Co., Ltd.


1B/F., Building 1, Yibaolai Industrial Park, Qiaotou,
Address ..................................................................... :
Fuyong, Bao’an District, Shenzhen, Guangdong, China
Testing location .......................................................: As above

Applicant’s name .................................................... :

Address ..................................................................... :
Manufacturer’s name ............................................. :

Address ..................................................................... :

Test specification :

Standard..................................................................... : IEC 62133: 2012

Test procedure .........................................................: Type approved

Test result ................................................................. : Pass

Non-standard test method ....................................: N/A

This test report is specially limited to the above client company and product model only, It may not
be duplicated without prior written consent of Shenzhen TCT Testing Technology Co., Ltd.

Test item description ............................................. : Rechargeable Li-ion Battery

Trade Mark ................................................................ : ---

Model/type reference ............................................. : 202440

Ratings .......................................................................: 3.7V, 230mAh, 0.85Wh

Page 1 of 23
This report shall not be reproduced except in full, without the written approval of Shenzhen TCT Testing Technology Co., Ltd.
Report No. TCT170814B012

List of Attachments (including a total number of pages in each attachment):


Attachment 1: Critical components information (page 15)
Attachment 1: Photo documentation (page 20-23)

Summary of testing:
Tests performed (name of test and test Testing location:
clause): Shenzhen TCT Testing Technology Co., Ltd.
cl.5.6.2 Design recommendation(Lithium system);
1B/F., Building 1, Yibaolai Industrial Park, Qiaotou,
cl.8.1 Charging procedure for test purposes (for Fuyong, Bao’an District, Shenzhen, Guangdong, China
Cells and Pack);
cl.8.2.1 Continuous charging at constant voltage
(Cells);
cl.8.3.1 External short circuit (Cells);
cl.8.3.2 External short circuit (Battery);
cl.8.3.3 Free fall (for Cells and Pack);
cl.8.3.4 Thermal abuse (Cells);
cl.8.3.5 Crush (Cells);
cl.8.3.6 Over-charging of battery;
cl.8.3.7 Forced discharge (Cells);
cl.8.3.8 Transport tests (Cells);
The electrolyte type of this cell doesn’t belong to
polymer, and the applicant declares that this cell
isn’t to be sold in France, Japan, Republic of
Korea and Switzerland.
Tests are made with the number of cells and
batteries specified in IEC 62133: 2012 (Second
Edition) Table 2.
Summary of compliance with National Differences:

The product fulfils the requirements of EN 62133: 2013

Copy of marking plate :


The artwork below may be only a draft

-(Black) Rechargeable Li-ion Battery


Model: 202440 1ICP4/20/31
3.7V 230mAh 0.85Wh

+(Red) Date: 2017. 07 Made in China

Page 2 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

Test item particulars..................................................... :

Classification of installation and use........................: To be defined in final product

Supply connection.........................................................: DC Lead wire

Recommend charging method declared by the Charging the battery with 115mA constant current
manufacturer.................................................................. : until 4.2V and then constant voltage until charging
current reduces to 4.6mA at ambient 20°C±5°C.

Discharge current (0,2 It A) ........................................ : 46mA

Specified final voltage................................................. : 3.0V

Chemistry ....................................................................... : nickel systems......... lithium systems

Recommend of charging limit for lithium system

Upper limit charging voltage per cell........................ : 4.25V

Maximum charging current......................................... : 230mA

Charging temperature upper limit..............................: 45°C

Charging temperature lower limit.............................. : 10°C

Polymer cell electrolyte type......................................: gel polymer solid polymer N/A

Possible test case verdicts:

- test case does not apply to the test object............ : N/A

- test object does meet the requirement................... : P (Pass)

- test object does not meet the requirement............ : F (Fail)

Testing.............................................................................. :

Date of receipt of test item........................................... : 2017-08-14

Date (s) of performance of tests................................. : 2017-08-14 to 2017-08-28

General remarks:
The test results presented in this report relate only to the object tested,
This report shall not be reproduced, except in full, without the written approval of the issuing testing
laboratory,
“(CXX #)” refers to sample number of cells, “X” is 0~9;
“(BXX #)” refers to sample number of cells, “X” is 0~9;
“(see below table)” refers to a table appended to the report.

Throughout this report a point is used as the decimal separator.

Page 3 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

General product information:


This battery is constructed with one Lithium-ion cell, and has overcharge, over-discharge, over current and
short-circuits proof circuit.

The main features of the cell in the battery pack are shown as below (clause 8.1.1):

Nominal Nominal Maximum Maximum Maximum


Nominal Nominal Cut-off
Model Charge Discharge Charge Discharge Charge
capacity voltage Voltage
Current Current Current Current Voltage

202440 230mAh 3.7V 115mA 115mA 230mA 230mA 4.2V 3.0V

The main features of the cell in the battery pack are shown as below (clause 8.1.2):
Taper-off
Upper limit Lower charge Upper charge
Model current
charge voltage temperature temperature
(0,05 It A)

202440 4.25V 11.5mA 10°C 45°C

The main features of the battery pack are shown as below (clause 8.1.1):
Nominal Nominal Maximum Maximum Maximum
Nominal Nominal Cut-off
Model Charge Discharge Charge Discharge Charge
capacity voltage Voltage
Current Current Current Current Voltage

202440 230mAh 3.7V 115mA 115mA 230mA 230mA 4.2V 3.0V

The main features of the battery pack are shown as below (clause 8.1.2):
Taper-off
Upper limit Lower charge Upper charge
Model current
charge voltage temperature temperature
(0,05 It A)

202440 4.25V 11.5mA 10C 45C

Construction:

Cell (Unit: mm)

Page 4 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

Battery (Unit: mm)

Circuit diagram:

Page 5 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

4 Parameter measurement tolerances P


Parameter measurement tolerances P

5 General safety considerations P


5.1 General P
5.2 Insulation and wiring P
The insulation resistance between the positive No metal case exists. N/A
terminal and externally exposed metal surfaces of
the battery (excluding electrical contact surfaces) is
not less than 5 MΩ
Insulation resistance (MΩ)......................................... : —
Internal wiring and insulation are sufficient to
withstand maximum anticipated current, voltage and P
temperature requirements
Orientation of wiring maintains adequate creepage P
and clearance distances between conductors
Mechanical integrity of internal connections P
accommodates reasonably foreseeable misuse
5.3 Venting P
Battery cases and cells incorporate a pressure relief Venting mechanism exists on P
mechanism or are constructed so that they relieve narrow side of the pouch cell.
excessive internal pressure at a value and rate that
will preclude rupture, explosion and self-ignition
Encapsulation used to support cells within an outer N/A
casing does not cause the battery to overheat during
normal operation nor inhibit pressure relief
5.4 Temperature/voltage/current management P
Batteries are designed such that abnormal Overcharge, over-discharge, P
temperature rise conditions are prevented over current and short-circuit
proof circuit used in this
battery. See tests of clause 8.
Batteries are designed to be within temperature, See above. P
voltage and current limits specified by the cell
manufacturer
Batteries are provided with specifications and The charging limits specified in P
charging instructions for equipment manufacturers the manufacturer’s
so that associated chargers are designed to specifications.
maintain charging within the temperature, voltage
and current limits specified
5.5 Terminal contacts P
Terminals have a clear polarity marking on the The “+(Red)” and “-(Black)” P
external surface of the battery polarity explicitly marked on
surface of the battery.
The size and shape of the terminal contacts ensure DC Lead wire contacts P
that they can carry the maximum anticipated current complied with the
requirements.

Page 6 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

External terminal contact surfaces are formed from P


conductive materials with good mechanical strength
and corrosion resistance
Terminal contacts are arranged to minimize the risk P
of short circuits
5.6 Assembly of cells into batteries P
5.6.1 If there is more than one battery housed in a single Single cell in the battery. N/A
battery case, cells used in the assembly of each
battery have closely matched capacities, be of the
same design, be of the same chemistry and be from
the same manufacturer
Each battery has an independent control and N/A
protection
Manufacturers of cells make recommendations N/A
about current, voltage and temperature limits so that
the battery manufacturer/designer may ensure
proper design and assembly
Batteries that are designed for the selective N/A
discharge of a portion of their series connected cells
incorporate separate circuitry to prevent the cell
reversal caused by uneven discharges
Protective circuit components are added as N/A
appropriate and consideration given to the end-
device application
When testing a battery, the manufacturer of the N/A
battery provides a test report confirming the
compliance according to this standard
5.6.2 Design recommendation for lithium systems only P
For the battery consisting of a single cell or a single Charging voltage: 4.2V, not P
cellblock: exceed 4.25V specified in
- Charging voltage of the cell does not exceed the Clause 8.1.2, table 4.
upper limit of the charging voltage specified in
Clause 8.1.2, Table 4; or
- Charging voltage of the cell does not exceed the N/A
different upper limit of the charging voltage
determined through Clause 8.1.2, NOTE 1.
For the battery consisting of series-connected plural N/A
single cells or series-connected plural cellblocks:
- The voltages of any one of the single cells or single
cellblocks does not exceed the upper limit of the
charging voltage, specified in Clause 8.1.2, Table 4,
by monitoring the voltage of every single cell or the
single cellblocks; or
- The voltages of any one of the single cells or single N/A
cellblocks does not exceed the different upper limit
of the charging voltage, determined through Clause
8.1.2, NOTE 1, by monitoring the voltage of every
single cell or the single cellblocks

Page 7 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

For the battery consisting of series-connected plural N/A


single cells or series-connected plural cellblocks:
- Charging is stopped when the upper limit of the
charging voltage, specified in Clause 8.1.2, Table 4,
is exceeded for any one of the single cells or single
cellblocks by measuring the voltage of every single
cell or the single cellblocks; or
- Charging is stopped when the upper limit of the N/A
different charging voltage, determined through
Clause 8.1.2, NOTE 1, is exceeded for any one of
the single cells or single cellblocks by measuring the
voltage of every single cell or the single cellblocks
5.7 Quality plan P
The manufacturer prepares and implements a Complied. P
quality plan that defines procedures for the ISO 9001: 2008 Certificate
inspection of materials, components, cells and provided.
batteries and which covers the whole process of
producing each type of cell or battery

6 Type test conditions P


Tests were made with the number of cells or Complied. P
batteries specified in Table 1 for nickel-cadmium Lithium system.
and nickel-metal hydride systems and Table 2 for
lithium systems, using cells or batteries that are not
more than six months old
Unless noted otherwise in the test methods, testing Tests are carried out at 20C P
was conducted in an ambient of 20C  5C.  5C.

7 Specific requirements and tests (nickel systems) N/A


7.1 Charging procedure for test purposes Lithium system. N/A
7.2 Intended use N/A
7.2.1 Continuous low-rate charging (cells) N/A
Results: No fire. No explosion N/A
7.2.2 Vibration N/A
Results: No fire. No explosion. No leakage (See Table 7.2.2) N/A
7.2.3 Moulded case stress at high ambient temperature N/A
Oven temperature (°C).................................................. : —
Results: No physical distortion of the battery casing N/A
resulting in exposure if internal components
7.2.4 Temperature cycling N/A
Results: No fire. No explosion. No leakage. N/A
7.3 Reasonably foreseeable misuse N/A
7.3.1 Incorrect installation cell N/A

Page 8 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

The test was carried out using: N/A


- Four fully charged cells of the same brand, type,
size and age connected in series, with one of them
reversed; or
- A stabilized dc power supply. N/A
Results: No fire. No explosion.................................... : (See Table 7.3.1) N/A
7.3.2 External short circuit N/A
The cells or batteries were tested until one of the N/A
following occurred:
- 24 hours elapsed; or
- The case temperature declined by 20% of the N/A
maximum temperature rise
Results: No fire. No explosion.................................... : (See Table 7.3.2) N/A
7.3.3 Free fall N/A
Results: No fire. No explosion. N/A
7.3.4 Mechanical shock (crash hazard) N/A
Results: No fire. No explosion. No leakage. N/A
7.3.5 Thermal abuse N/A
Oven temperature (°C).................................................. : —
Results: No fire. No explosion. N/A
7.3.6 Crushing of cells N/A
The crushing force was released upon: N/A
- The maximum force of 13 kN  1 kN has been
applied; or
- An abrupt voltage drop of one-third of the original N/A
voltage has been obtained
The cell is prismatic type and a second set of N/A
samples was tested, rotated 90° around longitudinal
axis compared to the first set
Results: No fire. No explosion.................................... : (See Table 7.3.6) N/A
7.3.7 Low pressure N/A
Chamber pressure (kPa)...............................................: —
Results: No fire. No explosion. No leakage. N/A
7.3.8 Overcharge N/A
Results: No fire. No explosion.................................... : (See Table 7.3.8) N/A
7.3.9 Forced discharge N/A
Results: No fire. No explosion.................................... : (See Table 7.3.9) N/A

Page 9 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

8 Specific requirements and tests (lithium systems) P


8.1 Charging procedures for test purposes Complied. P
8.1.1 First procedure: P
This charging procedure applied to tests other than
those specified in 8.1.2
8.1.2 Second procedure: P
This charging procedure applied to the tests of
8.3.1, 8.3.2, 8.3.4, 8.3.5, and 8.3.9
If a cell’s specified upper and/or lower charging Charge temperature range 10- N/A
temperature exceeds values for the upper and/or 45°C declared.
lower limit test temperatures of Table 4, the cells 10°C used for lower limit tests.
were charged at the specified values plus 5 °C for
the upper limit and minus 5 °C for the lower limit 45°C used for upper limit tests.

A valid rationale was provided to ensure the safety N/A


of the cell (see Figure A.1).......................................... :
For a different upper limit charging voltage (i.e. Lithium cobalt oxide system N/A
other than for lithium cobalt oxide systems at 4,25 only.
V), the applied upper limit charging voltage and
upper limit charging temperatures were adjusted
accordingly
A valid rationale was provided to ensure the safety 4.25V applied. N/A
of the cell (see Figure A.1).......................................... :
8.2 Intended use P
8.2.1 Continuous charging at constant voltage (cells) Tested complied. P
Results: No fire. No explosion.................................... : (See Table 8.2.1) P
8.2.2 Moulded case stress at high ambient temperature N/A
(battery)
Oven temperature (°C).................................................. : —
Results: No physical distortion of the battery casing N/A
resulting in exposure of internal components
8.3 Reasonably foreseeable misuse P
8.3.1 External short circuit (cell) Tested complied. P
The cells were tested until one of the following N/A
occurred:
- 24 hours elapsed; or
- The case temperature declined by 20% of the P
maximum temperature rise
Results: No fire. No explosion.................................... : (See Table 8.3.1) P
8.3.2 External short circuit (battery) Tested complied. P
The batteries were tested until one of the following P
occurred:
- 24 hours elapsed; or
- The case temperature declined by 20% of the N/A
maximum temperature rise

Page 10 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

In case of rapid decline in short circuit current, the N/A


battery pack remained on test for an additional one
hour after the current reached a low end steady
state condition
Results: No fire. No explosion.................................... : (See Table 8.3.2) P
8.3.3 Free fall Tested complied. P
Results: No fire. No explosion. No fire. No explosion. P
8.3.4 Thermal abuse (cells) P
The cells were held at 130C  2C for: Tested complied. P
- 10 minutes; or
- 30 minutes for large cells (gross mass of more N/A
than 500 g as defined in IEC 62281)
Oven temperature (°C).................................................. : 130C —
Gross mass of cell (g)....................................................: <500g, small cell. —
Results: No fire. No explosion. No fire. No explosion. P
8.3.5 Crush (cells) P
The crushing force was released upon: Tested complied. P
- The maximum force of 13 kN  1 kN has been
applied; or
- An abrupt voltage drop of one-third of the original N/A
voltage has been obtained; or
- 10% of deformation has occurred compared to the N/A
initial dimension
Results: No fire. No explosion.................................... : (See Table 8.3.5) P
8.3.6 Over-charging of battery Tested complied. P
Test was continued until the temperature of the N/A
outer casing:
- Reached steady state conditions (less than 10°C
change in 30-minute period); or
- Returned to ambient P
Results: No fire. No explosion.................................... : (See Table 8.3.6) P
8.3.7 Forced discharge (cells) Tested complied. P
Results: No fire. No explosion.................................... : (See Table 8.3.7) P
8.3.8 Transport tests Tested complied. P
Manufacturer’s documentation provided to show Tested complied. P
compliance with UN Recommendations on
Transport of Dangerous Goods
8.3.9 Design evaluation – Forced internal short circuit N/A
(cells)
The cells complied with national requirement for.......: The applicant declares that —
this cell isn’t to be sold in
France, Japan, Republic of
Korea and Switzerland.

Page 11 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

The pressing was stopped upon: N/A


- A voltage drop of 50 mV has been detected; or
- The pressing force of 800 N (cylindrical cells) or N/A
400 N (prismatic cells) has been reached
Results: No fire............................................................. : N/A

9 Information for safety P


The manufacturer of secondary cells ensures that Information for safety P
information is provided about current, voltage and mentioned in manufacturer’s
temperature limits of their products. specifications.
The manufacturer of batteries ensures that Information for safety P
equipment manufacturers and, in the case of direct mentioned in manufacturer’s
sales, end-users are provided with information to specifications.
minimize and mitigate hazards.
Systems analyses performed by device N/A
manufacturers to ensure that a particular battery
design prevents hazards from occurring during use
of a product
As appropriate, information relating to hazard N/A
avoidance resulting from a system analysis is
provided to the end user..............................................:

10 Marking P
10.1 Cell marking N/A
Cells marked as specified in the applicable cell The final product is battery. N/A
standards: IEC 61951-1, IEC 61951-2 or IEC 61960.
10.2 Battery marking P
Batteries marked in accordance with the The battery is marked in P
requirements for the cells from which they are accordance with IEC 61960,
assembled. See page 4.
Batteries marked with an appropriate caution N/A
statement.
10.3 Other information P
Storage and disposal instructions marked on or Information for storage P
supplied with the battery. instructions mentioned in
manufacturer’s specifications.
Recommended charging instructions marked on or Information for recommended P
supplied with the battery. charging instructions
mentioned in manufacturer’s
specifications.

11 Packaging P
The materials and packaging design are chosen so P
as to prevent the development of unintentional
electrical conduction, corrosion of the terminals and
ingress of environmental contaminants.

Page 12 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

Annex A Charging range of secondary lithium ion cells for safe use P
A.1 General P
A.2 Safety of lithium-ion secondary battery Complied. P
A.3 Consideration on charging voltage Complied. P
A.3.1 General P
A.3.2 Upper limit charging voltage 4.25V applied. P
A.3.2.1 General P
A.3.2.2 Explanation of safety viewpoint N/A
A.3.2.3 Safety requirements, when different upper limit 4.25V applied. N/A
charging voltage is applied
A.4 Consideration of temperature and charging current P
A.4.1 General P
A.4.2 Recommended temperature range See A.4.2.2. P
A.4.2.1 General N/A
A.4.2.2 Safety consideration when a different recommended Charging temperature range N/A
temperature range is applied declared by client is: 10-45C
A.4.3 High temperature range Not higher than the N/A
temperature specific in this
standard.
A.4.3.1 General N/A
A.4.3.2 Explanation of safety viewpoint N/A
A.4.3.3 Safety considerations when specifying charging N/A
conditions in high temperature range
A.4.3.4 Safety consideration when specifying new upper N/A
limit in high temperature range
A.4.4 Low temperature range Not lower than the N/A
temperature specific in this
standard.
A.4.4.1 General N/A
A.4.4.2 Explanation of safety viewpoint N/A
A.4.4.3 Safety considerations, when specifying charging N/A
conditions in low temperature range
A.4.4.4 Safety considerations when specifying a new lower N/A
limit in the low temperature range
A.4.5 Scope of the application of charging current P
A.5 Sample preparation N/A
A.5.1 General N/A
A.5.2 Insertion procedure for nickel particle to generate N/A
internal short

Page 13 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

IEC 62133: 2012


Clause Requirement + Test Result - Remark Verdict

The insertion procedure carried out at 20°C±5°C N/A


and under -25 °C of dew point
A.5.3 Disassembly of charged cell N/A
A.5.4 Shape of nickel particle N/A
A.5.5 Insertion of nickel particle to cylindrical cell N/A
A.5.5.1 Insertion of nickel particle to winding core N/A
A.5.5.2 Mark the position of nickel particle on the both end N/A
of winding core of the separator
A.5.6 Insertion of nickel particle to prismatic cell N/A

Page 14 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

Critical components information P


Object/part no. Manufacturer/ Type/model Technical data Standard Mark(s) of
trademark conformity
1)

Cell Dongguan 202440 3.7V, 230mAh IEC 62133: Tested with


Wiliyoung 2012 appliance
Electronics Co.,
Ltd.
- Positive Hunan Huahang HH-115 LiMn2O, Carbon -- --
electrode black, NMP, PVDF,
Conductive Additive
- Negative Zhuhai LZ-25 Graphite, CMC, SBR, -- --
electrode Lianzhong Distilled Water,
Conductive
- Separator Jujiguang JJG-0.16*26 Shutdown -- --
temperature: 130°C
546mm x 26mm x
0.016mm
- Electrolyte Hubei Nuobeng NP-605-5B LiPF6+EMC+EC -- --
Electronics Co.,
Ltd.
PCB Interchangeable Interchangeable V-0, 130°C UL 796 UL approved
Protection IC DEPUWEI DPDW01 VCU: 4.30 ± 0.05V, -- Tested with
(U1) VDL: 2.4±0.1V appliance
MOSFET PUOLOP PT8205 VDS: 20V, VGS: ±12V, -- Tested with
(Q1) ID: 6A appliance

Lead wire Interchangeable Interchangeable 24AWG, 80°C, 30V UL 758 UL approved


Tape Interchangeable Interchangeable 130°C UL 510 UL approved
Supplementary information:
1)
Provided evidence ensures the agreed level of compliance.

Page 15 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012

8.2.1 TABLE: Continuous charging at constant voltage (cells) P


Model Recommended Recommended OCV at start of Results
charging voltage charging current test, (Vdc)
Vc, (Vdc) Irec, (mA)
C1# 4.20 115 4.18 P
C2# 4.20 115 4.17 P
C3# 4.20 115 4.18 P
C4# 4.20 115 4.17 P
C5# 4.20 115 4.18 P
Supplementary information:
- No fire
- No explosion
- No leakage

8.3.1 TABLE: External short circuit (cells) P


Model Ambient, (C) OCV at start of Resistance of Maximum case Results
test, (Vdc) circuit, (m) temperature
rise T, (C)
Samples charged at charging temperature upper limit (45C)
C1# 25.0 4.21 75 117.1 P
C2# 25.0 4.20 76 113.5 P
C3# 25.0 4.20 77 114.7 P
C4# 25.0 4.21 75 119.8 P
C5# 25.0 4.21 76 114.6 P
Samples charged at charging temperature lower limit (10C)
C6# 25.0 4.16 76 111.9 P
C7# 25.0 4.17 75 114.1 P
C8# 25.0 4.16 75 115.5 P
C9# 25.0 4.16 75 108.7 P
C10# 25.0 4.17 77 113.8 P
Supplementary information:
- No fire
- No explosion

Page 16 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
8.3.2 TABLE: External short circuit (battery) P
Model Ambient, (C) OCV at start of Resistance of Maximum case Results
test, (Vdc) circuit, (m) temperature
rise T, (C)
Samples charged at charging temperature upper limit (45C)
B1# 55.0 4.21 75 55.3 P
B2# 55.0 4.21 76 55.4 P
B3# 55.0 4.20 77 55.5 P
B4# 55.0 4.20 76 55.5 P
B5# 55.0 4.21 77 55.2 P
Samples charged at charging temperature lower limit (10C)
B6# 55.0 4.16 78 55.4 P
B7# 55.0 4.17 76 55.3 P
B8# 55.0 4.17 76 55.2 P
B9# 55.0 4.17 77 55.5 P
B10# 55.0 4.16 75 55.3 P
Supplementary information:
- No fire
- No explosion

8.3.5 TABLE: Crush P


Model OCV at start of OCV at Width/ Required Results
test, (Vdc) removal of diameter of deformation
crushing force, cell before for crush,
(Vdc) crush, (mm) (mm)
Samples charged at charging temperature upper limit (45C)
C1# 4.21 -- -- -- P
C2# 4.21 -- -- -- P
C3# 4.20 -- -- -- P
C4# 4.20 -- -- -- P
C5# 4.21 -- -- -- P
Note:
A 13kN force applied at the wide side of prismatic cells.
No voltage abrupt drop occurred.
Supplementary information:
- No fire
- No explosion

Page 17 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
8.3.6 TABLE: Over-charging of battery P
Constant charging current (A).....................................: 0.46 
Supply voltage (Vdc)......................................................: 5.0 
Model OCV before Resistance of Maximum outer Results
charging, (Vdc) circuit, (m) casing temperature,
(C)
B1# 3.31 15.2 30.4 P
B2# 3.32 15.3 29.6 P
B3# 3.32 15.4 28.7 P
B4# 3.31 14.9 30.3 P
B5# 3.31 15.2 29.5 P
Supplementary information:
- No fire
- No explosion

8.3.7 TABLE: Forced discharge (cells) P


Model OCV before Measured Time for reversed Results
application of Reverse charge It, charge, (minutes)
reverse charge, (mA)
(Vdc)
C1# 3.31 230 90 P
C2# 3.32 230 90 P
C3# 3.32 230 90 P
C4# 3.31 230 90 P
C5# 3.31 230 90 P
Supplementary information:
- No fire
- No explosion

Page 18 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
8.3.8 T-5 TABLE: External short circuit (cells) P
Model Ambient, (C) OCV at start of Resistance of Maximum case Results
test, (Vdc) circuit, (m) temperature
rise T, (C)
C1# 55.0 4.18 75 118.5 P
C2# 55.0 4.17 77 117.3 P
C3# 55.0 4.18 78 113.4 P
C4# 55.0 4.17 76 119.8 P
C5# 55.0 4.17 78 117.7 P
C6# 55.0 4.17 78 118.9 P
C7# 55.0 4.18 77 114.6 P
C8# 55.0 4.17 78 115.7 P
C9# 55.0 4.18 76 122.6 P
C10# 55.0 4.18 76 116.7 P
Supplementary information:
The external short-circuit test of 10 pcs samples performed after the test of Altitude, Thermal cycling,
Vibration and Shock in sequence.
- No excessive temperature rise, no rupture, no explosion and no fire

8.3.9 TABLE: Forced internal short circuit (cells) N/A


Model Chamber OCV at start of Particle Maximum Voltage Results
ambient, (C) test, (Vdc) location 1) applied drop, (mV)
pressure, (N)

Supplementary information:
1)
Identify one of the following:
1: Nickel particle inserted between positive and negative (active material) coated area.
2: Nickel particle inserted between positive aluminium foil and negative active material coated area.
- No fire

Page 19 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Attachment 1
Photo Documentation

Product: Rechargeable Li-ion Battery


Type Designation: 202440

Picture 1. Battery view-1

Picture 2. Battery view-2

Page 20 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Photo Documentation

Picture 3. Battery view-3

Picture 4. Battery view-4

Page 21 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Photo Documentation

Picture 5. Cell view-5

Picture 6. Cell view-6

Page 22 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Report No. TCT170814B012
Photo Documentation

Picture 7. Protection board view-7

Picture 8. Protection board view-8

*** End of Test Report ***

Page 23 of 23
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Test Report
Report No. : TCT170823C004 Date : Aug. 25, 2017 Page No.: 1 of 3

Applicant:
Address:

The following sample was submitted and identified by/on behalf of the client as:
Sample Name: Li-ion Battery
Model No.: 503040
Sample Received Date: 2017.08.23
Testing Period: 2017.08.23—2017.08.25
Test Requested: Accordance with Directive 2006/66/EC, to determine the Lead (Pb), Cadmium
(Cd), Mercury (Hg) contents of the submitted sample(s).
Test Method: Please refer to the following page(s).
Test Result(s): Please refer to the following page(s).
Conclusion: Test results of submitted sample(s) comply with the limit set by Directive
2006/66/EC and its amendment 2013/56/EU.

Checked by Signed for and on behalf of TCT

Chris Zhong Kim Zhang


Technical Manager

Shenzhen TCT Testing Technology Co., Ltd.


1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Test Report
Report No. : TCT170823C004 Date : Aug. 25, 2017 Page No.: 2 of 3

Test Results:

Lead, Cadmium and Mercury Content(s)

Test Labelling Permissible


Test Items Test Method Unit MDL
Results Requirement# Limit

Lead (Pb) With reference to N.D. 0.0010 >0.004 --


GB/T 20155-2006, %
Cadmium (Cd) Analysis was N.D. 0.0010 >0.002 0.002##
performed by (w/w)
ICP-OES >0.0005
Mercury (Hg) N.D. 0.0001 0.0005

Note : - MDL = Method Detection Limit


- N.D. = Not detected, less than MDL.
#
- = According to the article 21.3, batteries, accumulators and button cells containing more
than 0,0005 % mercury, more than 0,002 % cadmium or more than 0,004 % lead, shall be
marked with the chemical symbol for the metal concerned: Hg, Cd or Pb.
##
- = Not apply to portable batteries and accumulators intended for use in:
(a) emergency and alarm systems, including emergency lighting;
(b) medical equipment; or
(c) cordless power tools.
- Results shown is/are of total weight of the battery sample.
- “--” = Not Regulated.
- According to the article 21.1, all batteries, accumulators and battery packs should be
appropriately marked with the crossed-out wheeled bin symbol.

Test Process:

Weigh sample and Add suitable digestion Digest samples


place in a digestion acid in the digestion completely in Microwave/
vessel. vessel. hotplate digestion oven.

Analyze by ICP-AES/ Make up with Transfer the digestive


AAS/ Mercury deionized water. solution into a suitable
Analyzer. volumetric flask.

Shenzhen TCT Testing Technology Co., Ltd.


1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District, Shenzhen, Guangdong, China
Hotline: 400-6611-140 Tel: 86-755-27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Test Report
Report No. : TCT170823C004 Date : Aug. 25, 2017 Page No.: 3 of 3

Photo(s) of the sample(s)

*** End of Report ***

Remark:This report is considered invalidated without the Special Seal for Inspection of the TCT. This
report shall not be altered, increased or deleted. The results shown in this test report refer only to the
sample(s) tested. Without written approval of TCT, this test report shall not be copied except in full and
published as advertisement.

Shenzhen TCT Testing Technology Co., Ltd.