Load Feeders and Soft Starters
Load Feeders and Soft Starters
Load Feeders and Soft Starters
SIRIUS12
3RA1
up to 100 A
3RA11 10 3RA11 20 3RA11 30 Direct-on-line starting Rated control supply voltage 50 Hz, AC 230 V1)
for 35 mm standard mounting rail or screw mounting
Circuit-breaker and contactor are linked electrically
and mechanically by means of a link module
NSKSY142
As from size 2 with adapter2) for standard mounting rail
for mechanical strengthening
Auxiliary switches 3) on the circuit-breaker and the contactor
can be easily fitted due to the modular system
(on contactor size S00: 1 NO integrated)
nsb0219 nsb0220
nsb0221
Three-phase standard Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
motor 4-pole at Inverse-time DT Order No. Price approx.
AC 400 V4) delayed overload
Standard Motor release
output current Circuit-breaker + Contactor + Link module
(guide val.) +
P I
Adapter for stand-
kW A A PG 101 1 unit kg ard mounting rail1)
Type of coordination 2 at Iq = 50 kA/100 kA at 400 V (compatible with type of coor.1)6)
0.06 0.2 0.14 ... 0.2 A 3RA11 10-0BA15-1AP0 0.47 S00 3RV10 11-0BA10
0.06 0.2 0.18 ... 0.25 A 3RA11 10-0CA15-1AP0 3RV10 11-0CA10
0.09 0.3 0.22 ... 0.32 A 3RA11 10-0DA15-1AP0 3RV10 11-0DA10
0.09 0.3 0.28 ... 0.4 A 3RA11 10-0EA15-1AP0 3RV10 11-0EA10
0.12 0.4 0.35 ... 0.5 A 3RA11 10-0FA15-1AP0 3RV10 11-0FA10
0.18 0.6 0.45 ... 0.63 A 3RA11 10-0GA15-1AP0 3RV10 11-0GA10 3RT10 15-1AP01 3RA19 11-1AA00
0.18 0.6 0.55 ... 0.8 A 3RA11 10-0HA15-1AP0 3RV10 11-0HA10 +
5)
0.25 0.8 0.7 ... 1 A 3RA11 10-0JA15-1AP0 3RV10 11-0JA10
0.37 1.1 0.9 ... 1.25 A 3RA11 10-0KA15-1AP0 3RV10 11-0KA10
0.55 1.5 1.1 ... 1.6 A 3RA11 10-1AA15-1AP0 3RV10 11-1AA10
0.75 1.9 1.4 ... 2 A 3RA11 10-1BA15-1AP0 3RV10 11-1BA10
0.75 1.9 1.8 ... 2.5 A 3RA11 20-1CA24-0AP0 0.73 S0 3RV10 21-1CA10
1.1 2.7 2.2 ... 3.2 A 3RA11 20-1DA24-0AP0 3RV10 21-1DA10
1.5 3.6 2.8 ... 4 A 3RA11 20-1EA24-0AP0 3RV10 21-1EA10
1.5 3.6 3.5 ... 5 A 3RA11 20-1FA24-0AP0 3RV10 21-1FA10 3RT10 24-1AP00
2.2 5.2 4.5 ... 6.3 A 3RA11 20-1GA24-0AP0 3RV10 21-1GA10
3 6.8 5.5 ... 8 A 3RA11 20-1HA24-0AP0 3RV10 21-1HA10 3RA19 21-1AA00
4 9.0 7 ... 10 A 3RA11 20-1JA26-0AP0 3RV10 21-1JA10 +
5)
5.5 11.5 9 ... 12.5 A 3RA11 20-1KA26-0AP0 3RV10 21-1KA10
7.5 15.5 11 ... 16 A 3RA11 20-4AA26-0AP0 3RV10 21-4AA10 3RT10 26-1AP00
7.5 15.5 14 ... 20 A 3RA11 20-4BA26-0AP0 3RV10 21-4BA10
11 22 17 ... 22 A 3RA11 20-4CA26-0AP0 3RV10 21-4CA10
11 22 18 ... 25 A 3RA11 30-4DB34-0AP0 1.9 S2 3RV10 31-4DA10
15 29 22 ... 32 A 3RA11 30-4EB34-0AP0 3RV10 31-4EA10 3RT10 34-1AP00
3RA19 31-1AA00
18.5 35 28 ... 40 A 3RA11 30-4FB35-0AP0 3RV10 31-4FA10 3RT10 35-1AP00 +
22 41 36 ... 45 A 3RA11 30-4GB36-0AP0 3RV10 31-4GA10 3RA19 32-1AA00
22 41 40 ... 50 A 3RA11 30-4HB36-0AP0 3RV10 31-4HA10 3RT10 36-1AP00
3RA1
up to 100 A
nsb0219g nsb0220g
Three-phase standard Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
motor 4-pole at Inverse-time DT Order No. Price approx.
AC 400 V3) delayed overload
Standard Motor release
output current Circuit-breaker + Contactor + Link module
(guide val.) +
P I
Adapter for stand-
kW A A PG 101 1 unit kg ard mounting rail1)
Type of coordination 2 at Iq = 50 kA/100 kA at 400 V (compatible with type of coor.1)5)
0.06 0.2 0.14 ... 0.2 A 3RA11 10-0BA15-1BB4 0.47 S00 3RV10 11-0BA10
0.06 0.2 0.18 ... 0.25 A 3RA11 10-0CA15-1BB4 3RV10 11-0CA10
0.09 0.3 0.22 ... 0.32 A 3RA11 10-0DA15-1BB4 3RV10 11-0DA10
0.09 0.3 0.28 ... 0.4 A 3RA11 10-0EA15-1BB4 3RV10 11-0EA10
0.12 0.4 0.35 ... 0.5 A 3RA11 10-0FA15-1BB4 3RV10 11-0FA10
0.18 0.6 0.45 ... 0.63 A 3RA11 10-0GA15-1BB4 3RV10 11-0GA10 3RT10 15-1BB41 3RA19 11-1AA00
0.18 0.6 0.55 ... 0.8 A 3RA11 10-0HA15-1BB4 3RV10 11-0HA10 +
0.25 0.8 0.7 ... 1 A 3RA11 10-0JA15-1BB4 3RV10 11-0JA10 4)
1) Adapters for standard mounting rail 3) Selection depends on the specific startup 4) Screw fitting with 1 push-in lug each per
also suitable for screw fitting. and rated data of the protected motor. load feeder; see accessories, page 5/14.
2) For auxiliary switches see accessories, page 5/10. 5) Load feeders ≥ 100 kA see page 5/17.
SIRIUS12
3RA1
up to 100 A
nsb0224g
nsb0223g
Three-phase standard Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
motor 4-pole at Inverse-time approx.
AC 400 V3) delayed overload DT Order No. Price
release Order No. suffix
Standard Motor cur- see below
output rent Circuit-breaker + Contactor + Link module
(guide val.)
P I +
kW A A PG 101 1 unit kg Busbar adapter
Type of coordination 2 at Iq = 50 kA at 400 V (compatible with type of coord. 1)
0.06 0.2 0.14 ... 0.2 A 3RA11 10-0B@15-1AP0 0.65 S00 3RV10 11-0BA10
0.06 0.2 0.18 ... 0.25 A 3RA11 10-0C@15-1AP0 3RV10 11-0CA10
0.09 0.3 0.22 ... 0.32 A 3RA11 10-0D@15-1AP0 3RV10 11-0DA10
3RA19 11-1AA00
0.09 0.3 0.28 ... 0.4 A 3RA11 10-0E@15-1AP0 3RV10 11-0EA10 +
0.12 0.4 0.35 ... 0.5 A 3RA11 10-0F@15-1AP0 3RV10 11-0FA10 40 mm
0.18 0.6 0.45 ... 0.63 A 3RA11 10-0G@15-1AP0 3RV10 11-0GA10 3RT10 15-1AP01
8US10 51-5DM07
0.18 0.6 0.55 ... 0.8 A 3RA11 10-0H@15-1AP0 3RV10 11-0HA10 or 60 mm
0.25 0.8 0.7 ... 1 A 3RA11 10-0J@15-1AP0 3RV10 11-0JA10 8US12 51-5DM07
0.37 1.1 0.9 ... 1.25 A 3RA11 10-0K@15-1AP0 3RV10 11-0KA10
0.55 1.5 1.1 ... 1.6 A 3RA11 10-1A@15-1AP0 3RV10 11-1AA10
0.75 1.9 1.4 ... 2 A 3RA11 10-1B@15-1AP0 3RV10 11-1BA10
0.75 1.9 1.8 ... 2.5 A 3RA11 20-1C@24-0AP0 0.93 S0 3RV10 21-1CA10
1.1 2.7 2.2 ... 3.2 A 3RA11 20-1D@24-0AP0 3RV10 21-1DA10
1.5 3.6 2.8 ... 4 A 3RA11 20-1E@24-0AP0 3RV10 21-1EA10 3RT10 24-1AP00
1.5 3.6 3.5 ... 5 A 3RA11 20-1F@24-0AP0 3RV10 21-1FA10 3RA19 21-1AA00
2.2 5.2 4.5 ... 6.3 A 3RA11 20-1G@24-0AP0 3RV10 21-1GA10 +
3 6.8 5.5 ... 8 A 3RA11 20-1H@24-0AP0 3RV10 21-1HA10 40 mm
8US10 51-5DM07
4 9.0 7 ... 10 A 3RA11 20-1J@26-0AP0 3RV10 21-1JA10 or 60 mm
5.5 11.5 9 ... 12.5 A 3RA11 20-1K@26-0AP0 3RV10 21-1KA10 8US12 51-5DM07
7.5 15.5 11 ... 16 A 3RA11 20-4A@26-0AP0 3RV10 21-4AA10 3RT10 26-1AP00
7.5 15.5 14 ... 20 A 3RA11 20-4B@26-0AP0 3RV10 21-4BA10
11 22 17 ... 22 A 3RA11 20-4C@26-0AP0 3RV10 21-4CA10
11 22 18 ... 25 Size S2 S2 3RV10 31-4DA10 3RA19 31-1AA00
only available 3RT10 34-1AP00 +
15 29 22 ... 32 3RV10 31-4EA10
for self-assembly. 40 mm
18.5 35 28 ... 40 3RV10 31-4FA10 3RT10 35-1AP00 8US10 61-5FP08
22 41 36 ... 45 3RV10 31-4GA10 or 60 mm
3RT10 36-1AP00
22 41 40 ... 50 3RV10 31-4HA10 8US12 61-5FP08
30 55 45 ... 63 For size S3 S3 3RV10 41-4JA10 3RT10 44-1AP00
37 67 57 ... 75 no adapters for 3RV10 41-4KA10 3RT10 45-1AP00 3RA19 41-1AA00
busbar mounting +
45 80 70 ... 90 are available. 3RV10 41-4LA10
3RT10 46-1AP00 not available
45 80 80 ... 100 3RV10 41-4MA10
Type of coordination 1at Iq = 50 kA at 400 V
(the circuit-breaker is compatible with type of coordination 2)
0.75 1.9 1.4 ... 2 Load feeders for lower
outputs see table above.
0.75 1.9 1.8 ... 2.5 A 3RA11 10-1C@15-1AP0 0.65 S00 3RV10 11-1CA10
1.1 2.7 2.2 ... 3.2 A 3RA11 10-1D@15-1AP0 3RV10 11-1DA10 3RA19 11-1AA00
1.5 3.6 2.8 ... 4 A 3RA11 10-1E@15-1AP0 3RV10 11-1EA10 3RT10 15-1AP01 +
1.5 3.6 3.5 ... 5 A 3RA11 10-1F@15-1AP0 3RV10 11-1FA10 40 mm
2.2 5.2 4.5 ... 6.3 A 3RA11 10-1G@15-1AP0 3RV10 11-1GA10 8US10 51-5DM07
3 6.8 5.5 ... 8 A 3RA11 10-1H@15-1AP0 3RV10 11-1HA10 or 60 mm
4 9.0 7 ... 10 A 3RA11 10-1J@16-1AP0 3RV10 11-1JA10 3RT10 16-1AP01 8US12 51-5DM07
5.5 11.5 9 ... 12 A 3RA11 10-1K@17-1AP0 3RV10 11-1KA10 3RT10 17-1AP01
7.5 15,5 11 ... 16 A 3RA11 20-4A@25-0AP0 0.93 S0 3RV10 21-4AA10 3RA19 21-1AA00
7.5 15.5 14 ... 20 A 3RA11 20-4B@25-0AP0 3RV10 21-4BA10 3RT10 25-1AP00 +
11 22 17 ... 22 A 3RA11 20-4C@25-0AP0 3RV10 21-4CA10 40 mm
11 22 20 ... 25 A 3RA11 20-4D@26-0AP0 3RV10 21-4DA10 3RT10 26-1AP00 8US10 51-5DM07
or 60 mm
15 29 22 ... 32 Load feeders for higher 8US12 51-5DM07
18.5 35 28 ... 40 outputs see table above.
22 41 36 ... 45
...
Order No. suffix
40 mm busbar centre-line spacing . . . . . . . . . . . . . . . . . . . . . C
60 mm busbar centre-line spacing . . . . . . . . . . . . . . . . . . . . . D
1) Size S00 also suitable for 60 Hz. 2) For auxiliary switches see accessories, page 5/10. 3) Selection depends on the specific startup
and rated data of the protected motor.
3RA1
up to 100 A
nsb0224g
nsb0223g
Three-phase standard Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
motor 4-pole at Inverse-time approx.
AC 400 V2) delayed overload DT Order No. Price
release Order No. suffix
Standard Motor see below
output current Circuit-breaker + Contactor + Link module
(guide val.)
P I +
SIRIUS12
3RA1
up to 100 A
nsb0225g
Three-phase standard Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
motor 4-pole at Inverse-time DT Order No. Price approx.
AC 400 V4) delayed overload
Standard Motor release
output current Circuit-breaker + 2 contactors + Link module
(guide val.)
P I +
RH = Reversing duty for rail mounting. 3) For auxiliary switches, see accessories page 5/10. with 1 push-in lug each per load feeder possible; see
1) Size S00 also suitable for 60 Hz. 4) Selection depends on the specific startup accessories, page 5/14.
2) Assembly kit for adapter for standard mounting rail and rated data of the protected motor. 6) Mechanical interlock must be ordered separately;
also suitable for screw fitting. 5) Wiring kit required; screw fixing see accessories, page 5/12.
7) Load feeders ≥ 100 kA see page 5/17.
5/6 Siemens NS K · 2002
Load Feeders and Soft Starters
SIRIUS Fuseless Load Feeders
SIRIUS12
3RA1
up to 100 A
nsb0225g
Three-phase standard Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
motor 4-pole at Inverse-time DT Order No. Price approx.
AC 400 V3) delayed overload
Standard Motor release
output current Circuit-breaker + 2 contactors + Link module
(guide val.)
P I +
kW A A PG 101 1 unit kg Assembly kit RH1)
Type of coordination 2 at Iq = 50 kA/100 kA at 400 V (compatible with type coord. 1) 6)
0.06 0.2 0.14 ... 0.2 A 3RA12 10-0BA15-0BB4 0.72 S00 3RV10 11-0BA10
0.06 0.2 0.18 ... 0.25 A 3RA12 10-0CA15-0BB4 3RV10 11-0CA10
0.09 0.3 0.22 ... 0.32 A 3RA12 10-0DA15-0BB4 3RV10 11-0DA10
0.09 0.3 0.28 ... 0.4 A 3RA12 10-0EA15-0BB4 3RV10 11-0EA10
0.12 0.4 0.35 ... 0.5 A 3RA12 10-0FA15-0BB4 3RV10 11-0FA10 3RA19 11-1AA00
0.18 0.6 0.45 ... 0.63 A 3RA12 10-0GA15-0BB4 3RV10 11-0GA10 3RT10 15-1BB42 +
3RA19 13-2A4)
0.18 0.6 0.55 ... 0.8 A 3RA12 10-0HA15-0BB4 3RV10 11-0HA10
0.25 0.8 0.7 ... 1 A 3RA12 10-0JA15-0BB4 3RV10 11-0JA10
0.37 1.1 0.9 ... 1.25 A 3RA12 10-0KA15-0BB4 3RV10 11-0KA10
0.55 1.5 1.1 ... 1.6 A 3RA12 10-1AA15-0BB4 3RV10 11-1AA10
0.75 1.9 1.4 ... 2 A 3RA12 10-1BA15-0BB4 3RV10 11-1BA10
0.75 1.9 1.8 ... 2.5 A 3RA12 20-1CB24-0BB4 1.8 S0 3RV10 21-1CA10
1.1 2.7 2.2 ... 3.2 A 3RA12 20-1DB24-0BB4 3RV10 21-1DA10
1.5 3.6 2.8 ... 4 A 3RA12 20-1EB24-0BB4 3RV10 21-1EA10 3RT10 24-1BB40
1.5 3.6 3.5 ... 5 A 3RA12 20-1FB24-0BB4 3RV10 21-1FA10
2.2 5.2 4.5 ... 6.3 A 3RA12 20-1GB24-0BB4 3RV10 21-1GA10 3RA19 21-1BA00
3 6.8 5.5 ... 8 A 3RA12 20-1HB24-0BB4 3RV10 21-1HA10 +
4 9.0 7 ... 10 A 3RA12 20-1JB26-0BB4 3RV10 21-1JA10 3RA19 23-1B5)
5.5 11.5 9 ... 12.5 A 3RA12 20-1KB26-0BB4 3RV10 21-1KA10
7.5 15.5 11 ... 16 A 3RA12 20-4AB26-0BB4 3RV10 21-4AA10 3RT10 26-1BB40
7.5 15.5 14 ... 20 A 3RA12 20-4BB26-0BB4 3RV10 21-4BA10
11 22 17 ... 22 A 3RA12 20-4CB26-0BB4 3RV10 21-4CA10
11 22 18 ... 25 Size S2 S2 3RV10 31-4DA10
15 29 22 ... 32 only available 3RV10 31-4EA10 3RT10 34-1BB40
3RA19 31-1BA00
18.5 35 28 ... 40 for self-assembly. 3RV10 31-4FA10 3RT10 35-1BB40 +
22 41 36 ... 45 3RV10 31-4GA10 3RA19 33-1B5)
3RT10 36-1BB40
22 41 40 ... 50 3RV10 31-4HA10
30 55 45 ... 63 Size S3 S3 3RV10 41-4JA10 3RT10 44-1BB40
3RA19 41-1BA00
37 67 57 ... 75 only available 3RV10 41-4KA10 3RT10 45-1BB40
+
45 80 70 ... 90 for self-assembly. 3RV10 41-4LA10
3RT10 46-1BB40 3RA19 43-1B5)
45 80 80 ... 100 3RV10 41-4MA10
Type of coordination 1 at Iq = 50 kA at 400 V 6)
(the circuit-breaker is compatible with type of coordination 2)
0.75 1.9 1.4 ... 2 Load feeders for lower
outputs see table above.
0.75 1.9 1.8 ... 2.5 A 3RA12 10-1CA15-0BB4 0.72 S00 3RV10 11-1CA10
1.1 2.7 2.2 ... 3.2 A 3RA12 10-1DA15-0BB4 3RV10 11-1DA10
1.5 3.6 2.8 ... 4 A 3RA12 10-1EA15-0BB4 3RV10 11-1EA10 3RT10 15-1BB42 3RA19 11-1AA00
1.5 3.6 3.5 ... 5 A 3RA12 10-1FA15-0BB4 3RV10 11-1FA10 +
2.2 5.2 4.5 ... 6.3 A 3RA12 10-1GA15-0BB4 3RV10 11-1GA10 3RA19 13-2A4)
3 6.8 5.5 ... 8 A 3RA12 10-1HA15-0BB4 3RV10 11-1HA10
4 9.0 7 ... 10 A 3RA12 10-1JA16-0BB4 3RV10 11-1JA10 3RT10 16-1BB42
5.5 11.5 9 ... 12 A 3RA12 10-1KA17-0BB4 3RV10 11-1KA10 3RT10 17-1BB42
7.5 15.5 11 ... 16 A 3RA12 20-4AB25-0BB4 1.8 3RV10 21-4AA10
3RA19 21-1BA00
7.5 15.5 14 ... 20 A 3RA12 20-4BB25-0BB4 S0 3RV10 21-4BA10 3RT10 25-1BB40
+
11 22 17 ... 22 A 3RA12 20-4CB25-0BB4 3RV10 21-4CA10 3RA19 23-1B5)
11 22 20 ... 25 A 3RA12 20-4DB26-0BB4 3RV10 21-4DA10 3RT10 26-1BB40
15 29 22 ... 32 Load feeders for higher
18.5 35 28 ... 40 outputs see table above.
22 41 36 ... 45
...
RH = Reversing duty for rail mounting. 3) Selection depends on the specific startup 5) Mechanical locking device to be ordered sepa-
1) Assembly kit for adapter for standard mounting rail and rated data of the protected motor. rately, see accessories, page 5/12.
also suitable for screw fitting. 4) Wiring kit necessary; screw fitting with 6) Load feeders ≥ 100 kA see page 5/17.
2) For auxiliary switches, see accessories, page 5/10. 1 push-in lug each per load feeder;
see accessories, page 5/14.
Siemens NS K · 2002 5/7
Load Feeders and Soft Starters
Fuseless Load Feeders SIRIUS
SIRIUS12
3RA1
up to 100 A
nsb0228g
Three-phase stand- Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
ard motor 4-pole at Inverse-time approx.
AC 400 V3) delayed over- DT Order No. Price
load Order No. suffix
Stand- Motor see below
ard current release Circuit-breaker + 2 contactors + Link module
output (guide val.)
+
P I
kW A A PG 101 1 unit kg Assembly kit
RS5)
Type of coordination 2 at Iq = 50 kA at 400 V (compatible with type of coord. 1)
0.06 0.2 0.14 ... 0.2 A 3RA12 10-0B@15-0AP0 1.1 S00 3RV10 11-0BA10
0.06 0.2 0.18 ... 0.25 A 3RA12 10-0C@15-0AP0 3RV10 11-0CA10
0.09 0.3 0.22 ... 0.32 A 3RA12 10-0D@15-0AP0 3RV10 11-0DA10
3RA19 11-1AA00
0.09 0.3 0.28 ... 0.4 A 3RA12 10-0E@15-0AP0 3RV10 11-0EA10 +
0.12 0.4 0.35 ... 0.5 A 3RA12 10-0F@15-0AP0 3RV10 11-0FA10 40 mm
0.18 0.6 0.45 ... 0.63 A 3RA12 10-0G@15-0AP0 3RV10 11-0GA10 3RT10 15-1AP02 3RA19 13-1C
0.18 0.6 0.55 ... 0.8 A 3RA12 10-0H@15-0AP0 3RV10 11-0HA10 or 60 mm
3RA19 13-1D
0.25 0.8 0.7 ... 1 A 3RA12 10-0J@15-0AP0 3RV10 11-0JA10
0.37 1.1 0.9 ... 1.25 A 3RA12 10-0K@15-0AP0 3RV10 11-0KA10
0.55 1.5 1.1 ... 1.6 A 3RA12 10-1A@15-0AP0 3RV10 11-1AA10
0.75 1.9 1.4 ... 2 A 3RA12 10-1B@15-0AP0 3RV10 11-1BA10
0.75 1.9 1.8 ... 2.5 A 3RA12 20-1C@24-0AP0 1.6 S0 3RV10 21-1CA10
1.1 2.7 2.2 ... 3.2 A 3RA12 20-1D@24-0AP0 3RV10 21-1DA10
1.5 3.6 2.8 ... 4 A 3RA12 20-1E@24-0AP0 3RV10 21-1EA10 3RA19 21-1AA00
3RT10 24-1AP00
1.5 3.6 3.5 ... 5 A 3RA12 20-1F@24-0AP0 3RV10 21-1FA10 +
2.2 5.2 4.5 ... 6.3 A 3RA12 20-1G@24-0AP0 3RV10 21-1GA10 40 mm
3RA19 23-1C 4)
3 6.8 5.5 ... 8 A 3RA12 20-1H@24-0AP0 3RV10 21-1HA10 or 60 mm
4 9.0 7 ... 10 A 3RA12 20-1J@26-0AP0 3RV10 21-1JA10 3RA19 23-1D 4)
5.5 11.5 9 ... 12.5 A 3RA12 20-1K@26-0AP0 3RV10 21-1KA10
7.5 15.5 11 ... 16 A 3RA12 20-4A@26-0AP0 3RV10 21-4AA10 3RT10 26-1AP00
7.5 15.5 14 ... 20 A 3RA12 20-4B@26-0AP0 3RV10 21-4BA10
11 22 17 ... 22 A 3RA12 20-4C@26-0AP0 3RV10 21-4CA10
11 22 18 ... 25 Size S2 S2 3RV10 31-4DA10 3RA19 31-1AA00
15 29 22 ... 32 only available for self-assem- 3RV10 31-4EA10 3RT10 34-1AP00 +
bly. 40 mm: 3RA19 33-1C4)
18.5 35 28 ... 40 3RV10 31-4FA10 3RT10 35-1AP00 or 60 mm
22 41 36 ... 45 3RV10 31-4GA10 3RA19 33-1D 4)
3RT10 36-1AP00
22 41 40 ... 50 3RV10 31-4HA10
30 55 45 ... 63 For size S3 S3 3RV10 41-4JA10 3RT10 44-1AP00
37 67 57 ... 75 no adapters for 3RV10 41-4KA10 3RT10 45-1AP00 3RA19 41-1AA00
busbar mounting +
45 80 70 ... 90 are available. 3RV10 41-4LA10 3RT10 46-1AP00 not available
45 80 80 ... 100 3RV10 41-4MA10
Type of coordination 1 at Iq = 50 kA at 400 V
(the circuit-breaker is compatible with type of coordination 2)
0.75 1.9 1.4 ... 2 Load feeders for lower
outputs see table above.
0.75 1.9 1.8 ... 2.5 A 3RA12 10-1C@15-0AP0 1.1 S00 3RV10 11-1CA10
1.1 2.7 2.2 ... 3.2 A 3RA12 10-1D@15-0AP0 3RV10 11-1DA10 3RA19 11-1AA00
1.5 3.6 2.8 ... 4 A 3RA12 10-1E@15-0AP0 3RV10 11-1EA10 3RT10 15-1AP02 +
1.5 3.6 3.5 ... 5 A 3RA12 10-1F@15-0AP0 3RV10 11-1FA10 40 mm
3RA19 13-1C
2.2 5.2 4.5 ... 6.3 A 3RA12 10-1G@15-0AP0 3RV10 11-1GA10 or 60 mm
3 6.8 5.5 ... 8 A 3RA12 10-1H@15-0AP0 3RV10 11-1HA10 3RA19 13-1D
4 9.0 7 ... 10 A 3RA12 10-1J@16-0AP0 3RV10 11-1JA10 3RT10 16-1AP02
5.5 11.5 9 ... 12 A 3RA12 10-1K@17-0AP0 3RV10 11-1KA10 3RT10 17-1AP02
7.5 15.5 11 ... 16 A 3RA12 20-4A@25-0AP0 1.6 S0 3RV10 21-4AA10 3RA19 21-1AA00
7.5 15.5 14 ... 20 A 3RA12 20-4B@25-0AP0 3RV10 21-4BA10 3RT10 25-1AP00 +
40 mm
11 22 17 ... 22 A 3RA12 20-4C@25-0AP0 3RV10 21-4CA10 3RA19 23-1C 4)
11 22 20 ... 25 A 3RA12 20-4D@26-0AP0 3RV10 21-4DA10 3RT10 26-1AP00 or 60 mm
3RA19 23-1D 4)
15 29 22 ... 32 Load feeders for higher
18.5 35 28 ... 40 outputs see table above. 1) Size S00 also suitable for 60 Hz.
22 41 36 ... 45 2) For auxiliary switches see accessories, page 5/10.
... 3) Selection depends on the specific startup
Order No. suffix and rated data of the protected motor.
40 mm busbar centre-line spacing . . . . . . . . . . . . . . . . . . . C 4) Mechanical locking device must be ordered separately; see accessories,
60 mm busbar centre-line spacing . . . . . . . . . . . . . . . . . . . D page 5/12.
5) RS = Reversing duty for busbar systems.
3RA1
up to 100 A
nsb0228g
Three-phase stand- Setting range Fuseless load feeder Weight Size Consisting of the following individual devices
ard motor 4-pole at Inverse-time approx.
AC 400 V3) delayed overload DT Order No. Price
release Order No. suffix
Stand- Motor see below
ard current Circuit-breaker + 2 contactors + Link module
output (guide val.)
+
P I Assembly kit
kW A A PG 101 1 unit kg RS2)