Dow Integraflux™ Ultrafiltration Modules: Product Data Sheet
Dow Integraflux™ Ultrafiltration Modules: Product Data Sheet
Dow Integraflux™ Ultrafiltration Modules: Product Data Sheet
DOW IntegraFlux Ultrafiltration Modules can be used for a wide variety of treatment applications such
as industrial and municipal wastewaters, surface water, and seawater.
Product Specifications
Weight
Product Type Membrane Area Volume (empty/water filled)
m2 ft2 liters gallons kg/lbs kg/lbs
SFP-2860XP Industrial 51 549 35 9.3 48/83 106/183
NSF/ANSI 61
SFD-2860XP 51 549 35 9.3 48/83 106/183
and 419
SFP-2880XP Industrial 77 829 39 10.3 61/100 135/220
NSF/ANSI 61
SFD-2880XP 77 829 39 10.3 61/100 135/220
and 419
Page 1 of 3 ®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Form No. 795-50222, Rev 3
August 2017
Figure 1 SFP-2860XP, SFD-2860XP, SFP-2880XP, and SFD-2880XP (8-inch diameter)
Important Proper start-up of an ultrafiltration system is essential to prepare the membranes for operating service
Information and to prevent membrane damage. Following the proper start-up sequence also helps ensure that
system operating parameters conform to design specifications so that system water quality and
productivity goals can be achieved.
Before initiating system start-up procedures, membrane pretreatment, installation of the membrane
modules, instrument calibration and other system checks should be completed.
Page 2 of 3 ®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Form No. 795-50222, Rev 3
August 2017
Operation Avoid any abrupt pressure variations during start-up, shutdown, cleaning or other sequences to prevent
Guidelines possible membrane damage. Flush the ultrafiltration system to remove shipping solution prior to start-
up. Remove residual air from the system prior to start-up. Manually start the equipment. Depending on
the application, filtrate obtained from initial operations should be discarded.
General Information • If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty
will be null and void.
• To control biological growth during extended system shutdowns, it is recommended that storage
solution be injected into the membrane modules.
Please refer to the DOW UF Product Manual and Technical Service Bulletins.
Regulatory Note NSF/ANSI 61 and 419 certified drinking water modules require specific conditioning procedures prior to
producing potable water. Please refer to the product technical manual flushing section for specific
procedures. Drinking water modules may be subjected to additional regulatory restrictions in some
countries. Please check local regulatory guidelines and application status before use and sales.
Product Dow has a fundamental concern for all who make, distribute, and use its products, and for the
Stewardship environment in which we live. This concern is the basis for our product stewardship philosophy by
which we assess the safety, health, and environmental information on our products and then take
appropriate steps to protect employee and public health and our environment. The success of our
product stewardship program rests with each and every individual involved with Dow products - from
the initial concept and research, to manufacture, use, sale, disposal, and recycle of each product.
Customer Notice Dow strongly encourages its customers to review both their manufacturing processes and their
applications of Dow products from the standpoint of human health and environmental quality to ensure
that Dow products are not used in ways for which they are not intended or tested. Dow personnel are
available to answer your questions and to provide reasonable technical support. Dow product literature,
including safety data sheets, should be consulted prior to use of Dow products. Current safety data
sheets are available from Dow.
DOW™ Ultrafiltration Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and
For more information, call the Dow Water pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system.
& Process Solutions business:
North America: 1-800-447-4369 Notice: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may
Latin America: (+55) 11-5188-9222 differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this
Europe: +800-3-694-6367 document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable
Italy: +800-783-825 laws and other governmental enactments. The product shown in this literature may not be available for sale and/or available in all geographies
South Africa: +0800 99 5078
where Dow is represented. The claims made may not have been approved for use in all countries. Dow assumes no obligation or liability for the
Pacific: +800 7776 7776
information in this document. References to “Dow” or the “Company” mean the Dow legal entity selling the products to Customer unless otherwise
China: +400 889-0789
expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
www.dowwaterandprocess.com
PURPOSE ARE EXPRESSLY EXCLUDED.
Page 3 of 3 ®TM Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow Form No. 795-50222, Rev 3
August 2017