02 Dose and Shielding Calculations RSRC 2018 EEI
02 Dose and Shielding Calculations RSRC 2018 EEI
02 Dose and Shielding Calculations RSRC 2018 EEI
1
Objectives
8/25/2018
External vs. Internal Radiation Exposure
Sealed Sources
– Radioactive material permanently contained in a capsule or
bound in a solid form, such that the radioactive material
cannot come out of the containment
Unsealed Sources
– Radioactive material that is not permanently sealed in a
capsule, therefore it could lose some of the radioactive
material
8/25/2018
Radiation Types vs. Hazards
Radiation Types vs Hazards
The three (3) major principles to assist with maintaining doses ALARA.
Time
Time
Dose is proportional to
the time of exposure.
How to reduce time of exposure
• Reduce time in contact with radiation sources as much as
compatible with the task
• Training of a particular task using non-radioactive dummy
sources helps.
Distance
Distance
Radiation dose rate is inversely proportional to the square
of the distance from the source. This is known as Inverse
Square Law.
Mathematically expressed as
Where:
D1 = Dose rate at distance r1 from
the point source
D2 = Dose rate at distance r2 from
the point source
This formula can be used to estimate dose
from a source at any distance.
How to increase distance from a source
= 0.693
HVL
Do
D= x = nHVL
2n
Tenth Value Layer (TVL)
Thickness of shielding material that will reduce the dose or
dose rate to a tenth of its original value
= 2.303
TVL
Do x = nTVL
D=
10n
HVL and TVL
The half value layer (HVL) and tenth value layer (TVL) are
mathematically related as follows:
TVL 2.303
= = = = 3.323
HVL ln(2) 0.693
TVL = 3.323 x HVL
HVL and TVL
Source Gamma HVL (cm) TVL (cm)
Energy, MeV Concrete Lead Concrete Lead
60Co 1.17, 1.33 6.3 1.10 20.3 4.0
137Cs 0.66 4.9 0.65 16.3 2.2
131I 0.08 to 0.7 4.7 0.72 15.7 2.4
192Ir 0.2 to 1.4 4.3 0.55 14.0 1.9
226Ra 0.2 to 2.4 6.9 1.66 23.4 5.5
99mTc 0.14 0.02
100 kVp x-ray 1.65 0.026 5.42 0.087
200 kVp x-ray 2.59 0.043 8.55 0.142
Manual on Shielded Enclosures, Practical Radiation Safety Manual, PRSM-2 (Rev. 1), IAEA, 1996
Examples
1. What thickness of lead shielding is required so that
the dose rate at 50 cm from 1.5 GBq Co-60 will not
exceed 20 Gy/h?
DR = DRo e - x
r2
1.5 x 3570
502
DR = DRo e - x
0.02
= e - 0.63 x DRo = 2.142 mGy/h
2.142
DR = 20 Gy/h
ln 0.02 = - 0.63 x = 0.02 mGy/h
2.142
8/25/2018
Thank you.
E-mail:
[email protected]
48