SAW Components B9318
SAW Rx 2in1 filter 881.5 / 1960.0 MHz
Data sheet
Application
■ Low-loss RF filter for mobile telephone CDMA
systems, receive path (Rx) of Cellular and PCS
■ Also applicable for mobile phone WCDMA systems,
receive path of Band V and BAND II
■ Bandwidth
Filter 1 (Cellular): 25 MHz
Filter 2 (PCS): 60 MHz
■ Impedance transformation from:
Filter 1 (Cellular): 50 Ω to 100 Ω
Filter 2 (PCS): 50 Ω to 100 Ω
■ Unbalanced to balanced operation
Features
0,65
■ Package size 2.0 x1.6 x 0.68 mm3 0,26 0,50
■ Package code QCS10H 1 2 3 4
0,325
■ RoHS compatible
0,26
■ Approximate weight 0.008 g 10 5 bottom view
9 8 7 6
(SMT)
0,27 0,075
■ Ni, gold-plated terminals
■ Electrostatic Sensitive Device (ESD)
0,68
side view
2,0
1,6
top view
Pin configuration
■ 1 Input [ Filter 1: Cellular]
1 9
■ 4 Input [ Filter 2: PCS ]
■ 6,7 Output balanced [ Filter 2: PCS ]
■ 8,9 Output balanced [ Filter 1: Cellular ] 8
7
■ 2,3,5,10 Case ground
4 6
2,3,5,10
Attenuation α
0.0 ... 820.0 MHz 47 55 — dB
820.0 ... 835.0 MHz 45 48 — dB
835.0 ... 849.0 MHz 47 52 — dB
914.0 ... 950.0 MHz 24 30 — dB
950.0 ... 2000.0 MHz 45 52 — dB
2000.0 ... 3000.0 MHz 40 47 — dB
3000.0 ... 6000.0 MHz 40 45 — dB
Maximum ratings
Operable temperature range T –30/+85 ˚C
Storage temperature range Tstg –40/+85 ˚C
DC voltage VDC 5 V
ESD voltage VESD 1001) V machine model, 10 pulses
Input power at
continuous wave
WCDMA band V PIN 10 dBm
@ +55˚C ambient
Tx band
1) acc. to JESD22-A115A (machine model), 10 negative & 10 positive pulses.
S22 function
Attenuation α
DC ... 1600.0 MHz 40 45 — dB
1600.0 ... 1850.0 MHz 30 35 — dB
1850.0 ... 1910.0 MHz 20 24 — dB
2040.0 ... 2200.0 MHz 25 35 — dB
2200.0 ... 2800.0 MHz 30 36 — dB
2800.0 ... 3400.0 MHz 40 43 — dB
3400.0 ... 6000.0 MHz 30 41 — dB
1) Valid in temperature range -10 ... 80˚C. Guaranteed for -30˚C: 3.2 dB
pcb loss of 0.2dB extracted.
2) Valid in temperature range -10 ... 80˚C. Guaranteed for -30˚C: 2.2 dB
3) Valid in temperature range -10 ... 80˚C. Guaranteed for -30˚C: 1.1 dB
Maximum ratings
Operable temperature range T –30/+85 ˚C
Storage temperature range Tstg –40/+85 ˚C
DC voltage VDC 5 V
ESD voltage VESD 501) V machine model, 10 pulses
Input power at
continuous wave
WCDMA band II PIN 10 dBm
@ +55˚C ambient
Tx band
1) acc. to JESD22-A115A (machine model), 10 negative & 10 positive pulses.
S22 function
References
Type B9318
Packaging F61074-V8152-Z000
For further information please contact your local EPCOS sales office or visit our webpage at
www.epcos.com .
Published by EPCOS AG
Surface Acoustic Wave Components Division
P.O. Box 80 17 09, 81617 Munich, GERMANY
EPCOS AG 2007. This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incum-
bent on the customer to check and decide whether an EPCOS product with the properties
described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic compo-
nents or failure before the end of their usual service life cannot be completely ruled
out in the current state of the art, even if they are operated as specified. In customer
applications requiring a very high level of operational safety and especially in customer appli-
cations in which the malfunction or failure of a passive electronic component could endanger
human life or health (e.g. in accident prevention or life-saving systems), it must therefore be
ensured by means of suitable design of the customer application or other action taken by the
customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is
sustained by third parties in the event of malfunction or failure of a passive electronic compo-
nent.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Conse-
quently, we cannot guarantee that all products named in this publication will always be avail-
able.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-
sion of the “General Terms of Delivery for Products and Services in the Electrical
Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, CeraDiode, CSSP, PhaseCap, PhaseMod, SIFI, SIKOREL, Silver-
Cap, SIMID, SIOV, SIP5D, SIP5K, TOPcap, UltraCap, WindCap are trademarks registered
or pending in Europe and in other countries. Further information will be found on the Internet
at www.epcos.com/trademarks.