Cable Glands Catalogue Web
Cable Glands Catalogue Web
Cable Glands Catalogue Web
Cable glands
and cable entries
Venting element 34 - 36
GBP M
RAL 9005
GPA M12B 9005 7016880 6418074093370 M12 x 1,5 17 5 100
GPA M16B 9005 7016881 6418074093387 M16 x 1,5 22 5 100
GPA M20B 9005 7016566 6418074093394 M20 x 1,5 27 6 100
GPA M25B 9005 7016882 6418074093400 M25 x 1,5 32 6 100
GPA M32B 9005 7016883 6418074093417 M32 x 1,5 41 7 100
GPA M40B 9005 7016884 6418074093424 M40 x 1,5 50 7 50
GPA M50B 9005 7016885 6418074093431 M50 x 1,5 60 8 50
GPA M63B 9005 7016886 6418074093448 M63 x 1,5 75 8 50
RAL 9005
GPA PG7B 9005 7016580 6418074062314 Pg 7 19 5 100
GPA PG9B 9005 7016581 6418074062321 Pg 9 22 5 100
GPA PG11B 9005 7016582 6418074062338 Pg 11 24 5 100
GPA PG13.5B 9005 7016900 6418074093523 Pg 13,5 27 6 100
GPA PG16B 9005 7016901 6418074093530 Pg 16 30 6 100
GPA PG21B 9005 7016902 6418074093547 Pg 21 36 7 100
GPA PG29B 9005 7016903 6418074093554 Pg 29 46 7 100
GPA PG36B 9005 7016904 6418074093561 Pg 36 60 8 50
GPA PG42B 9005 7016905 6418074093578 Pg 42 65 8 50
GPA PG48B 9005 7016906 6418074093585 Pg 48 70 8 50
GSP PG PG thread
10
GPAPM PG/M
Adapter, plastic
GPAPM PG/M
11
12
13
14
15
16
17
18
GMSPM PG/M
Adapter, metal
GMSPM PG/M
19
Fundamentals, assembly instruction leads from a certain size on have a similar behaviour like an antenna
and are therefore a considerable coupling source for interference. Due
One important quality characteristics of electrical and electronic to the antenna-like action electromagnetic interference is recieved
products is their electromagnetic compatibility (EMC). To ensure and heterodynes the wanted signal. The result may be a malfunction
trouble-free operation of electrical appliances, systems and plants, of the appliance up to a total breakdown of the machines or production
the basic EMC requirements must be met, i.e. electrical devices must lines.
be protected from interference and must not themselves interfere
An effective protection in such cases is the use of cables and
with other appliances and equipment.
leads with shielding, that consists of a dense wire gauze or
In the field of plant engineering arise special problems due to enormous a thin metal foil. The function of the shielding is to trap and cushion
cable lenghts for energy supply and data transmission. Cables and interferences.
EMC
Cable glands play an important part in safeguarding EMC Our EMC cable glands glands meets these requirements in an
requirements where cables and leads enter into a shielding system. outstanding way.
They have to ensure a permanent connection with very low ohmic The assembly of cable gland type GMS EMC/M/ML is quick and
or inductive resistance between the cable shield and the housing easy:
potential. 1. Partially expose the braided screen by removing the outer
sheath of the cable at a lenght of approx. 10 mm
2. Insert the cable through the dome nut and the gland body until
the contact spring is pressed against the braided screen.
3. Firmly screw on dome nut – finished!
20
21
Ex cable gland
Fundamentals, assembly instruction Assembly instruction
1. Cut off outer cable sheath and expose braided screen
3xxEMC
Our G cable gland type GMS EMC/M/ML/MW ensures
continuous contacting without gaps. The dome nut and the over a length of approx. 10 – 15 mm, depending on the
lamellar insert are simply pushed onto the lead. The exposed cable diameter.
cable shield is folded around the lamellar insert, and the 2. Push dome nut and lamellar insert with sealing ring on
gland body is then pushed on. to the cable.
3. Bend braided screen outwards at a right angle (90°).
The screw-fitting of the dome nut ensures that the cable 4. Fold braided screen towards outer sheath, i.e. by
shield is pressed over a large surface between the torsion- another 180°.
protected lamellar insert and the gland body. 5. Push gland body up to braided screen and turn briefly
The result is a very good metal contact area of the cable around both sides of the cable axis.
shield via the gland body to the housing protected from 6. Push lamellar insert with sealing ring into gland body
external environmental influences. and snap anti-rotation element into place.
7. Firmly screw on dome nut.
Individual components
Sealing ring
Lamellar insert
Braided screen
Shielded cable
Dome nut
Gland body
22
23
24
25
26
27
28
29
Equipment group II
Category / Zone 2G, 2D and 3G/ 1, 2, 21, 22
Type of protection Ex e, increased safety
Ex tD A21 – Protection by enclosures
Temperature range +20...+70 °C (M12 and M16) °C
-55...+70 °C (M20 to M32) °C
Protection grade IP66
Test standard EN 60079-0 / EN 60079-7
EN 61241-0 / EN 61241-1
30
31
32
33
Venting element
Application
Waterproof enclosures with high protection grades for outdoor use are
not automatically sealed against vapour and humid air. To avoid negative
pressure, high humidity and condensation inside the enclosure a continuous
ventilation and pressure equilibrium is necessary.
This protectional function can be achieved by using a venting element,
quick and easy to install.
The body of the venting element is made from a flameproof polyamide.
Inside is a high-quality, breathable and watertight membrane, which
provides a continuous pressure exchange and ventilation between the
enclosure and its surroundings and ensures protection against humidity.
The high level of water intrusion point of the membrane enables the high
protection grade of IP66, IP67 and IP69K.
The achieved air flow ventilation of the membrane was determined by flow
control measuring.
34
Venting element
GVPPA M/ML
35
Venting element
GVPPA M/ML
36
O-ring
GOR M/PG
37
Dust cap
GDC M/PG
38
39
Hardness: 60 ± 5
(Shore density)
Push the grommet into the hole. The grommet is then locked in
position by pulling it back.
40
FEM/FEM-C/MFM Metric/Pg 16
MembraneH cable
H gland
FEM/FEM-C/MFMH1 H1
A A
Da
Da
B B
41
FIBOX FEM SL
The FEM SL is the latest addition to the FIBOX FEM The FEM SL is equipped with a sock that closes tight
membrane range. around the cable and allows for it to be moved around
What makes the FEM SL different from existing products on like a ”joy-stick” in the opening without endangering the IP-
the market are the built-in features that you do not find in classification. So it works extremely well with cables passing
this otherwise relatively simple product. through at an angle.
FEM SL handles an exceptionelly large cable span. It is The design makes sure that the membrane stays in place,
the only “simple” grommet manufactured in a rubber- even when large cables are installed.
like material, and the only TPE-based end-plug. With the These are some of the features that creates a lot of value
”pushout” membrane you always have a round opening and added in the FEM SL, and makes it a unique product.
are guaranteed to have IP67.
Push the grommet into the hole. Pierce the grommet with the cable.
42
FEM SL
D1
H2
H B
H1
Properties
Material TPE – Thermoplastic Elastomer - Quick and simple assembly without the use of tools
Halogen Free. Handles exceptionally large cable span
UL approved material An end-plug for all applications
Mode of protection IP67
Temperature range -50 °C....+125 °C
Test standard EN60529:1991+A1,
EMKO-TUI (03-SEC) FI001/84
RAL 9005
FEM SL 5-10 9005 3545226 6418074004987 M16 5 – 10 16,5 0,5 – 3 23,5 4 11 4 6,75 50
FEM SL 6-13 9005 3545227 6418074004994 M20 6 – 13 20,5 0,5 – 3 27,5 5 11 4 6,75 50
FEM SL 8-17 9005 3545230 6418074049292 M25 8 – 17 25,5 0,5 – 3,5 32,5 7 11 4 6,75 50
FEM SL 12-24 9005 3545231 6418074049308 M32 12 – 24 32,5 0,5 – 4,5 39,5 11 11 4 6,75 25
43
EPA MB FMC
Properties
Material Polycarbonate (PC); Membrane TPE
RAL 7035
Flame resistance UL 94-V1 (PC)
UL 94HB (TPE)
Accessories
MB 10346 3570346 6418074031204 Plastic head screw (M8x25) for size 2 flange
M-8 3570577 6418074031389 Lock nut for plastic head screws M8
MB 10670 3570670 6418074030788 Connector set, size 2; incl. 4 screws
44
Code 9637210
Fibox Oy Ab
Keilaranta 19
02150 Espoo
Finland