10 Reinforcement Calculation:: Sectional Plan

The document specifies reinforcement requirements for a foundation footing. It provides reinforcement sizes and spacing for the top, bottom, and sides of the footing as well as triaxial reinforcement. It then checks that the calculated weight of reinforcement provided meets the minimum requirement of 30kg/m3 of concrete. Finally, it notes the reinforcement arrangement meets code requirements for minimum longitudinal and total reinforcement.

Uploaded by

Stephen Koko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views1 page

10 Reinforcement Calculation:: Sectional Plan

The document specifies reinforcement requirements for a foundation footing. It provides reinforcement sizes and spacing for the top, bottom, and sides of the footing as well as triaxial reinforcement. It then checks that the calculated weight of reinforcement provided meets the minimum requirement of 30kg/m3 of concrete. Finally, it notes the reinforcement arrangement meets code requirements for minimum longitudinal and total reinforcement.

Uploaded by

Stephen Koko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 1

10 REINFORCEMENT CALCULATION:

Provide T 32 @ 125 c/c E/W Top and Bottom of Footing


Provide T 25 @ 200 c/c Sides of Footing
Provide T 12 @ 600 c/c Triaxial Vertical
Provide T 12 @ 600 c/c Triaxial Horizontal

10.1 CHECK FOR WEIGHT OF REINFORCEMENT

As the foundation is designed as a block foundation, a minimum shrinkage reinforcement of 30kg/m 3 shall be provided

Weight of reinf. required(footing) = 11.7 x 9.00 x 2.00 x 30 = 6318 kg


Reinforcement provided :
Footing
Top 60 bars x ( 9.00 + 2.000 ) x 3.86 = 2547.60 kg
73 bars x ( 11.70 + 2.000 ) x 6.32 = 6320.63 kg
Bottom same as that in top = 8868.23 kg
Sides (horz) 2.00 bars x 20.70 x 3.86 = 159.80 kg
2.00 bars x 20.70 x 3.86 = 159.80 kg
Triaxial (Horz) 19 bars x 9.00 x 0.89 = 152.19 kg
14 bars x 11.7 x 0.89 = 145.78 kg
Triaxial (Ver) 38 bars x 2.00 x 0.89 = 67.64 kg
Total Reinforcement in Foundation = 18421.68 kg > 6318 kg
Hence O.K
10.2 REINFORCEMENT SKETCH:

T32 - 125 c/c E/W Top and Bottom

SECTIONAL PLAN

T25 - 200 c/c T.O.G

Triaxial 38Nos of T12 - 600 c/c


B.O.F

Triaxial 19Nos of T12 - 600 c/c Triaxial 14Nos of T12 - 600 c/c

SECTIONAL ELEVATION
REINFORCEMENT ARRANGEMENT
10.3 Minimum Rebar Check

The reinforcement provided is as per Cl. No. 7.12.2.1, ACI 318M-05 @ 0.2% gross area (Top & Bottom reinforcement

in long. direction) & Cl. No 4.4.1, ACI 351.3R - 45, the minimum reinforcement of 0.38% gross area (total reinforcement

@ 30 kg/m3 of conc.).