Engineering Consultants Group: Checking and Packing Hall Checked by

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 3

ECG Project Name

Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


SEC. BEAM ID :- ( SB-1 ) Refrences
Steel grade St.37 ECP
Fy = 2.40 t/cm2
P (2)
Fu = 3.60 t/cm2 P (2)
1)- APPLIED FORCES :- Case Combination
M = 7.10 mt a
Q = 0.70 t

2)- CHOISE OF SECTION :-

The section is Rolled section IPE 300


bFL = 150.0 mm
tFL = 10.7 mm
h = 300.0 mm
tWEB = 7.1 mm

3)- BEAM DATA :-


Total length of Beam (L) = 5.00 m
Lu of compressin flange = 5.00 m

4)- CHECK SECTION :-


PROPERTIES OF SECTION :-

Y = 15.00 cm
A = 53.80 cm2
Ix = 8360.00 cm4
Sx = 557.00 cm3
rx = 12.50 cm
ry = 3.35 cm

CHECK COMPACTNESS :-
dw/tw = 35.014 Web is Compact table(2.1a)
C/tf = 5.276 Flange is Compact table(2.1c)
The sec is Compact

CHECK NORMAL STRESSES :-


Cb = 1.13 table(2.2)
( 20.bf ) / (√ fy ) = 1.936 m ECP 16
Lumax = 1.936 m
( 1380.Af ) / ( fy.d ) x Cb = 3.48 m eqn. 2.18
Lateral torsional buckling of comp.flange There is LTB
Fltb = 1.275 t/cm2
Fbcx = 1.275 t/cm2
fbcx = 1.275 t/cm2 < 1.275 SAFE

CHECK SHEAR STRESSES :-


qw = 0.04 t/cm2 < 0.840 SAFE eqn. 2.2

CHECK DEFLICTION DUO TO LIVE LOAD :-


WL.L = 0.30 t/m
Beam type = simple
δL.L = 0.139 cm < 1.67 SAFE ECP 132
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


table(9.1)
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


SEC. BEAM ID :- ( SB-1 ) Refrences
Steel grade St.37 ECP
Fy = 2.40 t/cm2 P (2)
Fu = 3.60 t/cm2 P (2)
1)- APPLIED FORCES :- Case Combination
M = 4.00 mt a
Q = 2.50 t

2)- CHOISE OF SECTION :-

The section is Built up section


bFLU = 250.00 mm The Comprision flange is bFLU
tFLU = 18.00 mm
hWeb = 200.00 mm
tWeb = 6.00 mm
bFLL = 250.00 mm
tFLL = 18.00 mm

3)- BEAM DATA :-


Total length of Beam (L) = 2.00 m
Lu of compressin flange = 10.00 m

4)- CHECK SECTION :-


PROPERTIES OF SECTION :-

Y = 11.80 cm
A = 102.00 cm2
Ix = 11117.20 cm4
Sx.top = 942.14 cm3
Sx.bot = 942.14 cm3

CHECK COMPACTNESS :-
dw/tw = 33.333 Web is Compact table(2.1a)
C/tf = 6.778 Flange is Compact table(2.1c)
The sec is Compact

CHECK NORMAL STRESSES :-


Cb = 1.30 table(2.2)
( 20.bf ) / (√ fy ) = 3.227 m ECP 16
Lumax = 3.227 m
( 1380.Af ) / ( fy.d ) x Cb = 16.82 m eqn. 2.18
Lateral torsional buckling of comp.flange There is LTB
Fltb = 1.392 t/cm2
Fbcx = 1.392 t/cm2
fbcx = 0.425 t/cm2 < 1.392 SAFE

CHECK SHEAR STRESSES :-


qw = 0.21 t/cm2 < 0.840 SAFE eqn. 2.2

CHECK DEFLICTION DUO TO LIVE LOAD :-


WL.L = 1.50 t/m
Beam type = simple
δL.L = 0.013 cm < 0.67 SAFE ECP 132
table(9.1)