This document summarizes the specifications of an automatic current and potential transformer test instrument. It can test the ratio error and phase displacement of current transformers with nominal currents of 5, 2, and 1 amp and potential transformers with nominal voltages ranging from 30 to 350 volts. It has a broad measurement range and high resolution. Test results can be remotely accessed and transferred via an RS232 interface. Key features include testing of electronic transformers and variants specialized for current transformers or potential transformers.

Uploaded by

Khoiln
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
231 views2 pages

Presco Technical PDF

This document summarizes the specifications of an automatic current and potential transformer test instrument. It can test the ratio error and phase displacement of current transformers with nominal currents of 5, 2, and 1 amp and potential transformers with nominal voltages ranging from 30 to 350 volts. It has a broad measurement range and high resolution. Test results can be remotely accessed and transferred via an RS232 interface. Key features include testing of electronic transformers and variants specialized for current transformers or potential transformers.

Uploaded by

Khoiln
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Automatic Current and Potential

Transformer Test - Set


Series - W
Metrology version

• For testing of ratio error and phase displacement of instrument


transformers
• Broad range of corrections
• Display of the results in all accepted dimensions
• Remote control and data transfer via RS232 interface
• Measures also electronic transformers
• Variants
o WD-SM for CT and PT
o WI-SM for CT
o WU-SM for PT

Presco AG
Zürcherstrasse 70 CH – 8104 Weiningen Switzerland
Tel.: +41 44 750 63 63 Fax: +41 44 750 63 66
[email protected] www.prescoag.com
Presco AG
Technical Specifications
Automatic Current and Potential Transformer Testing Instrument Type WD-SM00

Current Transformer test part


Nominal currents of the CT to be tested (X) 5, 2, and 1 A
Nominal Current of the standard CT (N) 5A
Matching 0.5 ... 1.6
Working range 1 ... 210% of nominal current
Frequency 50 and 60 Hz
Measuring range ratio error ± 20 %
Resolution ratio error 0.0001 % (1 ppm)
Measuring range phase angle ± 200 crad
Resolution phase angle 0.0001 Min or 1 µrad
Uncertainty of ratio measurement ± 10 ppm ± 0.5% of reading
Uncertainty of phase measurement ± 10 µrad ± 0.5% of reading
Inherent burden N-Side < 20mΩ
Inherent burden X-Side 30mΩ/5A , 80 mΩ/2A, 200mΩ/1A
Resolution current measurement 0.001 % / 0.0001A
Uncertainty current measurement ± 0.5% reading ± 1% of range

Potential Transformer test part


1 1
Nominal voltage of the PT to be tested (X) 30 ... 350 V with factors 1, /2, /3, 1/√3
1 1
Nominal voltage of the standard PT (N) 30 ... 350 V with factors 1, /2, /3, 1/√3
Matching 0.5 ... 1.6
Input voltage range N and X 1 V … 350 V
Frequency 50 and 60 Hz
Measuring range ratio error ± 20 %
Resolution ratio error 0.0001 % (1 ppm)
Measuring range phase angle ± 200 crad
Resolution phase angle 0.01 Min or 1 µrad
Uncertainty of ratio measurement ± 50 ppm ± 1% of reading
Uncertainty of phase measurement ± 50 µrad ± 1 % of reading
Inherent burden of X- and N-Side 30 kΩ … 110 kΩ
Resolution voltage measurement 0.1 % / 1 V
Uncertainty voltage measurement ± 1% reading ± 1% of range

Reference conditions
Temperature 23° C ± 2° C
Humidity 45 ... 75 %
Air pressure 101.3 kPa

Rated range of use


according to IEC 359
Temperature 5° C ... 40° C
Humidity, not condensing 10 ... 90 %
Air pressure 70 ... 106 kPa
Dimensions (W, D, H) 449 x 446 x 177 mm
19” x 4U
Weight 15 kg, 33 lbs
Power mains 115/230V 50/60Hz 50VA

specifications subject to changes without notice