Debitmetru Electromagnetic Mag3100 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 15

© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

■ Overview ■ Design
• Compact or remote mounting possible
• Easy “plug & play“ field changeability of transmitter
• Ex ATEX and CSA/FM versions
• High temperature sensor for applications with temperatures
up to 180 °C (356 °F)
• Approvals for PTB, OIML R75 and OIML R117
• Meets EEC directives: PED, 97/23/EC pressure directive for
EN1092-1 flanges
• Build-in length according to ISO 13359
• Onsite or factory upgrade to IP68/NEMA 6P of a standard sen-
sor.

■ Mode of operation
4 The flow measuring principle is based on Faraday’s law of elec-
tromagnetic induction were the sensor converts the flow into an
electrical voltage proportional to the velocity of the flow.

■ Integration
The complete flowmeter consists of a flow sensor and an asso-
ciated transmitter MAG 5000, 6000 and 6000 I.
The flexible communication concept USM II simplifies integra-
The SITRANS F M MAG 3100 is an electromagnetic flow sensor tion and update to a variety of fieldbus systems such as HART,
in a large variety that meets the demands of almost every flow FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS DP and PA,
application. MODBUS RTU/RS485.

■ Benefits
• Wide range of sizes: DN 15 to DN 2000 (½” to 78”)
• Wide pressure range: PN 6 to PN 100
ANSI Class 150 / 300, AS 2129 / AS 4087. On request up to
690 bar (10000 psi)
• Wide range of electrode and liner material to fit even the most
extreme process media
• Fully welded construction provides a ruggedness that suits
the toughest applications and environments
• Easy commissioning, the SENSORPROM unit automatically
updates settings.
• Designed to allow patented SITRANS F M in-situ verification
using the SENSORPROM fingerprints.

■ Application
The main applications of the SITRANS F M electromagnetic flow
sensors can be found in the following fields:
• Process industry
• Chemical industry
• Steel industry
• Mining
• Utility
• Power generation & distribution
• Oil & gas / HPI
• Water & waste water

4/64 Siemens FI 01 · 2009


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

■ Technical specifications
Version MAG 3100 MAG 3100 HT (High Temperature) MAG 3100 P
Nominal size DN 15 ... DN 2000 (½” ... 78“) DN 15 … DN 300 (½“ ... 12“) DN 15 … DN 300 (½“ ... 12“)
Measuring principle electromagnetic induction
Excitation frequency • DN 15 ... 65 (½“ … 2½”): 12.5 Hz • DN 15 ... 65 (½“ … 2½”): 12.5 Hz • DN 15 ... 65 (½“ … 2½”): 12.5 Hz
• DN 80 ... 150 (3” ... 6”): 6.25 Hz • DN 80 ... 150 (3” ... 6”): 6.25 Hz • DN 80 ... 150 (3” ... 6”): 6.25 Hz
• DN 200 ... 1200 (8” ... 48”): 3.125 Hz • DN 200 ... 300 (8” ... 12”): 3.125 Hz • DN 200 ... 300 (8” ... 12”): 3.125 Hz
• DN 1400 ... 2000 (54” ... 78”):
1.5625 Hz
Process connection
Flanges EN 1092-1, raised face EN 1092-1, raised face EN 1092-1, raised face
(EN 1092-1, DIN 2501 & BS 4504 have (EN 1092-1, DIN 2501 & BS 4504 have (EN 1092-1, DIN 2501 & BS 4504 have
the same mating dimensions) the same mating dimensions) the same mating dimensions)
• DN 65 ... 2000 (2½“ … 48”): PN 6 • DN 15 ... 300 (½“ … 12”): PN 40 • DN 15 ... 50 (½“ … 2”): PN 40
(87 psi) (580 psi) (580 psi)
• DN 200 ... 2000 (8“ … 48“): PN 10
(145 psi)
• DN 65 ... 300 (2½“ … 12”): PN 16
(232 psi)
• DN 65 ... 300 (2½“ … 12”): PN 16
(232 psi) 4
• DN 65 ... 2000 (2½“ … 78“): PN 16 • DN 200 ... 300 (8“ … 12“): PN 10 • DN 200 ... 300 (8“ … 12“): PN 10
(232 psi) (145 psi) (145 psi)
• DN 200 ... 600 (8“ … 24”): PN 25 • DN 200 ... 300 (8“ … 12”): PN 25
(362 psi) (362 psi) ANSI B16.5 (~BS 1560), raised face
• DN 15 ... 600 (½“ … 24”): PN 40 • ½” ... 12”: Class 150 (20 bar
(580 psi) ANSI B16.5 (~BS 1560), raised face: (290 psi))
• DN 50 ... 300 (2“ … 12“): PN 63 • ½” ... 12”: Class 150 (20 bar
(913 psi) (290 psi))
• DN 25 ... 300 (1“ … 12“): PN 100 • ½” ... 12”: Class 300 (50 bar
(1450 psi) (725 psi))
ANSI B16.5 (~BS 1560), raised face
• ½” ... 24”: Class 150 (20 bar AS 2129, raised face ½” ... 12”:
(290 psi)) Table E
• ½” ... 24”: Class 300 (50 bar
(725 psi))
Other flanges and pressure ratings on
AWWA C-207, flat face 28” ... 78”: request
Class D (10 bar)
AS 2129, raised face ½” ... 48”:
Table E
AS 4087, raised face:
• PN 16 (DN 50 ... 1200, 16 bar
(232 psi))
• PN 21 (DN 50 ... 600, 21 bar
(304 psi))
• PN 35 (DN 50 ... 600, 35 bar
(508 psi))
Other flanges and pressure ratings on
request
Rated operation conditions
Ambient temperature (con-
ditions also dependent on
liner characteristiques)
• Sensor -40 … +100 ºC (-40 … +212 °F) -40 … +100 ºC (-40 … +212 °F) -40 … +100 ºC (-40 … +212 °F)
• Sensor ATEX -20 … +60 ºC (-4 … +140 °F) for up to 150 °C (302 °F) temperature -20 … +60 ºC (-4 … +140 °F)
of medium:
-20 … +60 ºC (-4 … +140 °F)
for 150 ... 180 °C (302 ... 356 °F)
temperature of medium:
-20 … +50 ºC (-4 … +122 °F)
• With compact transmitter -20 … +50 ºC (-4 … +122 °F) -20 … +50 ºC (-4 … +122 °F) -20 … +50 ºC (-4 … +122 °F)
MAG 5000/6000
• With compact transmitter -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F)
MAG 6000 I
• With compact transmitter -10 … +60 ºC (14 … 140 °F) -10 … +60 ºC (14 … 140 °F) -10 … +60 ºC (14 … 140 °F)
MAG 6000 I Ex d

Siemens FI 01 · 2009 4/65


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100
Version MAG 3100 MAG 3100 HT (High Temperature) MAG 3100 P
Operating pressure
Operating pressure [abs. • Neoprene 0.01 ... 100 bar • PTFE Teflon • PTFE Teflon
bar] (maximum operating (0.15 ... 1450 psi) - DN 15 ... 300 (½“ … 12”) - DN 15 ... 300 (½“ … 12”) :
pressure decreases with • EPDM 0.01 ... 40 bar (0.15 ... 580 psi) (130/180 °C (266 °F/356ºF)): 0.3 ... 40 bar (4 ... 580 psi)
increasing operating temper- ® 0.3/0.6 ... 50 bar (4/8 ... 725 psi) • PFA
ature and with stainless steel • Linatex 0.01 ... 40 bar (180 ºC (356 ºF) PTFE has factory - DN 15 ... 100 (1“ … 4”):
flanges) (0.15 ... 580 psi) mounted grounding SS rings type E 0.01 ... 50 bar (0.15 ... 725 psi)
• Ebonite 0.01 ... 100 bar & SS terminal box)
(0.15 ... 1450 psi) • PFA
• PTFE (DN ≤ 300, 0.3 ... 50 bar/ - DN 25 ... 100 (1“ … 4”):
≤ 12“, 4 ... 725 psi) 0.01 ... 50 bar (0.15 ... 725 psi)
(350 ≤ DN ≤ 600/14“ ≤ DN ≤ 24“)
0.3 ... 40 bar (4 ... 580 psi)
• PFA
- DN 25 ... 100 (1“ … 4”):
0.01 ... 50 bar (0.15 ... 725 psi)
Enclosure rating IP67/NEMA 4X/6 to EN 60529, 1 mH2O IP67/NEMA 4X/6 to EN 60529, 1 mH2O IP67/NEMA 4X/6 to EN 60529, 1 mH2O

4 for 30 min
Option: IP68/NEMA 6P to
for 30 min
Option: IP68/NEMA 6P to
for 30 min
Option: IP68/NEMA 6P to EN 60529,
EN 60529,10 mH2O cont. (no ATEX) EN 60529,10 mH2O cont. (no ATEX) 10 mH2O cont. (no ATEX)
Pressure drop at 3 m/s As straigth pipe
Test pressure 1.5 x PN (where applicable)
Mechanical load • 18 ... 1000 Hz random in x, y z, direc- • 18 ... 1000 Hz random in x, y z, direc- • 18 ... 1000 Hz random in x, y z, direc-
tions for 2 hours according to tions for 2 hours according to tions for 2 hours according to
EN 60068-2-36 EN 60068-2-36 EN 60068-2-36
• Sensor: 3.17 grms • Sensor: 3.17 grms • Sensor: 3.17 grms
• Sensor with compact MAG 5000/ • Sensor with compact MAG 5000/ • Sensor with compact MAG 5000/
6000 mounted transmitter: 3.17 grms 6000 mounted transmitter: 3.17 grms 6000 mounted transmitter: 3.17 grms
• Sensor with compact MAG 6000 I/ • Sensor with compact MAG 6000 I/ • Sensor with compact MAG 6000 I/
6000 I Ex mounted transmitter: 6000 I Ex mounted transmitter: 6000 I Ex mounted transmitter:
1.14 grms 1.14 grms 1.14 grms
Temperature of medium • Neoprene 0 … +70 °C (32 … 158 °F) • PTFE -20 … +130 °C (-4 … +266 °F) • PTFE -20 … +130 °C (-4 … +266 °F)
• EPDM -10 … +70 °C (14 … 158 °F) • PTFE -20 … +180 °C (-4 ... +356 °F) • PFA -20 … +150 °C (-4 … +300 ºF)
• Linatex® (rubber) -40 … +70 °C Factory mounted grounding rings
(-40 … +158 °F) (for temperatures type E and SS terminal box. Can only
below -20 °C (-4 °F) AISI 304 or 316 be used with remote transmitter.
flanges must be used) • PFA -20 … +150 °C (-4 … +300 °F)
• Ebonite 0 … 95 °C (32 … 203 °F)
• PTFE -20 … +100 °C (-4 … +212 °F)
• PFA -20 … +100 °C (-4 … +212°F)
EMC 89/336 ECC 89/336 ECC 89/336 ECC
Design
Weight See dimensional drawings
Flange and housing material Carbon steel ASTM A 105, with corro- Carbon steel ASTM A 105, with corro- Carbon steel ASTM A 105, with corro-
sion resistant two component epoxy sion resistant two component epoxy sion resistant two component epoxy
coating (min. 150 μm) coating (min. 150 μm) coating (min. 150 μm)
or or
AISI 304 (1.4301) flanges and carbon AISI 304 (1.4301) flanges and carbon
steel housing, with corrosion resistant steel housing, with corrosion resistant
two component epoxy coating (min. two component epoxy coating (min.
150 μm) 150 μm)
or or
AISI 316 L (1.4404) flanges and hous- AISI 316 L (1.4404) flanges and hous-
ing, polished ing, polished
Measuring pipe material AISI 304 (1.4301) AISI 304 (1.4301) AISI 304 (1.4301)
(AISI 316L (1.4404) flanges and hous- (AISI 316L (1.4404) flanges and hous-
ing, polished has measuring pipe of ing, polished has measuring pipe of
AISI 316L (1.4435)) AISI 316L (1.4435))
Electrode material • AISI 316 Ti (1.4571) • AISI 316 Ti (1.4571) Hastelloy C276 (PFA: Hastelloy C22)
• Hastelloy C276 (PFA: Hastelloy C22) • Hastelloy C276 (PFA: Hastelloy C22)
• Platinum/Iridium, • Platinum/Iridium,
• Titanium • Titanium
• Tantalum • Tantalum
Grounding Electrode material Material as measuring electrodes: No grounding electrodes No grounding electrodes
Exceptions - see ordering data

4/66 Siemens FI 01 · 2009


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100
Version MAG 3100 MAG 3100 HT (High Temperature) MAG 3100 P
Design (continued)
Terminal box (remote version • Standard Fibre glass-reinforced • Stainless steel AISI 316 (1.4436) • Standard Fibre glass-reinforced
only) polyamide • Ex ATEX (remote version only) Stain- polyamide
• Option Stainless steel AISI 316 less steel AISI 316 (1.4436) • Option Stainless steel AISI 316
(1.4436) (1.4436)
• Ex ATEX (remote version only) Stain- • Ex ATEX (remote version only) Stain-
less steel AISI 316 (1.4436) less steel AISI 316 (1.4436)
Cable entries • Remote installation 2 x M20 or • Remote installation 2 x M20 or • Remote installation 2 x M20 or
2 x ½ NPT 2 x ½ NPT 2 x ½ NPT
• Compact installation • Compact installation
- MAG 5000/MAG 6000: 4 x M20 or - MAG 5000/MAG 6000: 4 x M20 or
4 x ½”NPT 4 x ½”NPT
- MAG 6000 I: 2 x M25 - MAG 6000 I: 2 x M25
(for supply/output) (for supply/output)
- MAG 6000 I Ex. d: 2 x M20 (for sup- - MAG 6000 I Ex. d: 2 x M20 (for sup-
ply/output) ply/output)
Certificates and approvals 4
Conforms to PED – 97/23 EC, CRN PED – 97/23 EC, CRN PED – 97/23 EC, CRN
Material certificate On request On request Pipe and flange certificate available as
EN 10204 3.1 option
Ex approvals ATEX 2G D sensor ATEX 2G D sensor ATEX 2G D sensor
• DN 15 ... 300: EEx d e ia IIC T4 - T6 • DN 15 ... 300: EEx d e ia IIC T3 - T6 • DN 15 ... 300: EEx d e ia IIC T3 - T6
• DN 350 ... 2000 EEx e ia IIC T4 - T6 Non ATEX sensors Non ATEX sensors
Non ATEX sensors • FM Class 1 Div 2 • FM Class 1 Div 2
• FM Class 1 Div 2 • CSA Class 1, Div 2 • CSA Class 1, Div 2
• CSA Class 1, Div 2
Drinking water approvals EPDM lining:
• WRAS (WRc, BS6920 cold water, GB)
• ACS listed (F)
• DVGW W270 (D)
• Belaqua (B)
Custody transfer (CT) Cold water pattern approval - DANAK Cold water pattern approval - DANAK Cold water pattern approval - DANAK
(≤ DN2000) TS 22.36.001, PTB (Denmark and Ger- TS 22.36.001, PTB (Denmark and Ger- TS 22.36.001, PTB (Denmark and Ger-
(only together with many) many) many)
MAG 5000/6000 CT), order Heat meter pattern approval - Heat meter pattern approval - Heat meter pattern approval -
as special OIML R 75 (Denmark) OIML R 75 (Denmark) OIML R 75 (Denmark)
Hot water pattern approval - PTB Hot water pattern approval - PTB Hot water pattern approval - PTB
(Germany) (Germany) (Germany)
Other media than water - OIML R 117 Other media than water - OIML R 117 Other media than water - OIML R 117
(Denmark) (Denmark) (Denmark)

Technical specification for transmitter - please see transmitter pages.

Siemens FI 01 · 2009 4/67


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100
Selection and Ordering data Order No. Selection and Ordering data Order No.
Sensor SITRANS F M MAG 3100 7 ME 6 3 1 0 - Sensor SITRANS F M MAG 3100 7 ME 6 3 1 0 -
77777 - 7777 77777 - 7777
Diameter Liner material
DN 15 (½“) (PTFE liner only) 1V Neoprene 1
DN 25 (1“) 2D EPDM 2
DN 40 (1½“) 2R PTFE (DN ≤ 300, PN ≤ 50 bar / ≤ 12“, PN ≤ 725 psi), 3
PTFE (350 ≤ DN ≤ 600, PN ≤ 40 bar /
DN 50 (2“) 2Y
14“ ≤ DN ≤ 24“, PN ≤ 580 psi)
DN 65 (2½“) 3F
Ebonite 4
DN 80 (3“) 3M
Linatex (PN ≤ 40 bar (580 psi) DN ≤ 600 (24“)) 5
DN 100 (4“) 3T PFA (DN 25, 50, 80, 100 (1", 2", 3", 4")) 7
DN 125 (5“) 4B (PN ≤ 40 bar (580 psi))
DN 150 (6“) 4H Electrode material
DN 200 (8“) 4P (Grounding electrodes not for PTFE/PFA liner or
DN 250 (10“) 4V Pressure PN 100)

4 DN 300 (12“)
DN 350 (14“)
5D
5K
AISI 316 TI
Hastelloy C276 (PFA liner: Hastelloy C22)
1
2
Platinum (DN ≤ 300/12") (no grounding electrodes) 3
DN 400 (16“) 5R
DN 450 (18“) 5Y Titanium (not PFA liner) 4
Tantalum (DN ≤ 600 (24")) (no grounding electrodes) 5
DN 500 (20“) 6F
DN 600 (24“) 6P Transmitter with display
DN 700 (28“) 6Y Sensor for remote transmitter (Order transmitter sep.) A
DN 750 (30“) 7D Sensor ATEX 2G D for remote transmitter (Order B
DN 800 (32“) 7H transmitter separately)
DN 900 (36“) 7M MAG 6000 I, Alu.18 ... 90 V DC, 115 ... 230 V AC C
MAG 6000 I Alu. 18 ... 30 V DC, ATEX 2G D D
DN 1000 (40“) 7R
MAG 6000 I Alu. 115 ... 230 V, ATEX 2G D E
DN 1050 (42“) 7U
MAG 6000 Polyamid, 11… 30 V DC / 11…24 V AC H
DN 1100 (44“) 7V
MAG 6000, Polyamid, 115/230 V AC J
DN 1200 (48“) 8B
DN 1400 (54“) 8F MAG 5000, Polyamid, 11… 30 V DC / 11…24 V AC K
DN 1500 (60“) 8K MAG 5000, Polyamid, 115/230 V AC L
DN 1600 (66“) 8P Communication
DN 1800 (72“) 8T No communication, add-on possible A
DN 2000 (78“) 8Y HART B
Flange norm and pressure rating PROFIBUS PA Profile 3 F
(only MAG 6000/MAG 6000 I)
to EN 1092-1
PN 6 (DN 65 ... 2000 (2½“ ... 78“)) A PROFIBUS DP Profile 3 (no ATEX) G
(only MAG 6000/MAG 6000 I)
PN 10 (DN 200 ... 2000 (8“ ... 78“)) B
MODBUS RTU/RS 485 (no ATEX) E
PN 16 (DN 65 ... 1200 (2½“ ... 48“)) C
(only MAG 6000/MAG 6000 I)
PN 16, non PED (DN 700 ... 2000 (28“ ... 78“)) D FOUNDATION Fieldbus H1 J
PN 25 (DN 200 ... 600 (8“ ... 24“)) E (only MAG 6000/MAG 6000 I)
PN 40 (DN 15 ... 600 (½“ ... 24“)) F Cable glands/terminal box
PN 63 (DN 50 ... 300 (2“ ... 12“)), not PTFE or PFA G Metric: Polyamid terminal box or 6000I compact 1
PN 100 (DN 25 ... 300 (1“ ... 12“)), not PTFE or PFA H ½" NPT: Polyamid terminal box or 6000I compact 2
to ANSI B16.5 Metric: SS terminal box (mandatory for Stainless 3
Class 150 (½“ ... 24“) J steel MAG 6000 Transmitter)
Class 300 (½“ ... 24“) K ½" NPT: SS terminal box (mandatory for Stainless 4
steel MAG 6000 Transmitter)
to AWWA C207
Class D (28“ ... 78“) L
to AS
2129, table E M
4087, PN 16 (DN 50 ... 1200 (2“ ... 48“)) N
4087, PN 21 (DN 50 ... 600 (2“ ... 24“)) P
4087, PN 35 (DN 50 ... 600 (2“ ... 24“)) Q
Flange material
Carbon steel flanges ASTM A 105 1
Stainless steel flanges, AISI 304 2
Stainless steel flanges and sensor body, AISI 316L, 3
polished
Please also see www.siemens.com/SITRANSFordering
for practical examples of ordering

4/68 Siemens FI 01 · 2009


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

Selection and Ordering data Order code


Additional information
Please add “-Z“ to Order No. and specify Order
code(s) and plain text.
Customer specific converter setup Y20
Tag name plate, stainless steel fixed with SS wire Y17
(add plain text)
Tag name plate, plastic (self adhesive) Y18
Factory certificate according to EN 10204-2.1 C15
Factory certificate according to EN 10204-2.2 C14
Sensor cables wired (specify cable order no.) Y40
Sensor for remote transmitter's junction box potted to Y41
IP68 with wired cable (specify cable order no.)
(no ATEX)
Other postproduction requirements (add desired text) Y99

Description Order No. 4


Potting kit for terminal box FDK-085U0220
of SITRANS F M sensors for
IP68/NEMA 6P (Not ATEX)

Please use online Product selector to get latest updates.


Product selector link:
www.pia-selector.automation.siemens.com
MAG 5000/6000 transmitters and sensors are packed in sepa-
rate boxes, the final assembly takes place during installation at
the customer's place. MAG 6000 I/MAG 6000 I ATEX 2G D trans-
mitters and sensors are delivered compact mounted from fac-
tory.
Communication module will be pre-mounted in the transmitter.

Siemens FI 01 · 2009 4/69


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100
Selection and Ordering data Order No. Selection and Ordering data Order No.
Sensor SITRANS F M Sensor SITRANS F M
MAG 3100 HT (High Temperature) 7 ME 6 3 2 0 - MAG 3100 HT (High Temperature) 7 ME 6 3 2 0 -
77777 - 7777 77777 - 7777
Diameter Communication
DN 15 (½“) 1V No communication, add-on possible A
DN 25 (1“) 2D HART B
DN 40 (1½“) 2R
PROFIBUS PA Profile 3 F
DN 50 (2“) 2Y (only MAG 6000/MAG 6000 I)
DN 65 (2½“) 3F
PROFIBUS DP Profile 3 G
DN 80 (3“) 3M (only MAG 6000/MAG 6000 I)
DN 100 (4“) 3T MODBUS RTU/RS 485 E
DN 125 (5“) 4B (only MAG 6000/MAG 6000 I)
DN 150 (6“) 4H FOUNDATION Fieldbus H1 J
DN 200 (8“) 4P (only MAG 6000/MAG 6000 I)

4 DN 250 (10“)
DN 300 (12“)
4V
5D
Cable glands/terminal box
Metric: Polyamid terminal box or 6000I compact 1
Flange norm and pressure rating ½" NPT: Polyamid terminal box or 6000I compact 2

to EN 1092-1 Metric: SS terminal box (mandatory for Stainless 3


steel MAG 6000 Transmitter)
PN 10 (DN 200 ... 300 (8“ ... 12“)) B
½" NPT: SS terminal box (mandatory for Stainless 4
PN 16 (DN 65 ... 300 (2½“ ... 12“)) C
steel MAG 6000 Transmitter)
PN 25 (DN 200 ... 300 (8“ ... 12“)) E
PN 40 (DN 15 ... 300 (½“ ... 12“)) F
to ANSI B16.5
Selection and Ordering data Order code
Class 150 (½“ ... 12“) J
Class 300 (½“ ... 12“) K Additional information

to AS Please add “-Z“ to Order No. and specify Order


code(s) and plain text.
2129, table E M
Customer specific converter setup Y20
Flange material
Tag name made, stainless steel fixed with SS wire Y17
Carbon steel flanges ASTM A 105 1
(add plain text)
Stainless steel flanges, AISI 304 2
Stainless steel flanges and sensor body, 3 Tag name plate, plastic (self adhesive) Y18
AISI 316L, polished Factory certificate according to EN 10204-2.1 C15
Liner material Factory certificate according to EN 10204-2.2 C14
PTFE (130 °C (266 °F)) 2
Sensor cables wired (specify cable order no.) Y40
PTFE including type E protection rings AISI 316 3
(180 °C (356 °F)) Other postproduction requirements (add desired text) Y99
PFA (150 ºC (302 ºF)) (DN 25, 50, 80, 100 7
(1", 2", 3", 4 "))
Electrode material (no grounding electrodes) Please use online Product selector to get latest updates.
AISI 316 TI 1 Product selector link:
Hastelloy C276 (PFA liner: Hastelloy C22) 2 www.pia-selector.automation.siemens.com
Platinum 3
MAG 5000/6000 transmitters and sensors are packed in sepa-
Titanium (not for PFA) 4 rate boxes, the final assembly takes place during installation at
Tantalum 5 the customer's place. MAG 6000 I/MAG 6000 I ATEX 2G D trans-
Transmitter with display
mitters and sensors are delivered compact mounted from fac-
tory.
Sensor for remote transmitter (Order transmitter A Communication module will be pre-mounted in the transmitter.
separately)
Sensor ATEX 2G D for remote transmitter (Order B
transmitter separately)
MAG 6000 I, Alu.18 ... 90 V DC, 115 ... 230 V AC C
MAG 6000 I, Alu. 18 ... 30 V DC, ATEX 2G D D
MAG 6000 I, Alu. 115 ... 230 V, ATEX 2G D E
MAG 6000, Polyamid, 11 ... 30 V DC/11 ... 24 V AC H
MAG 6000, Polyamid, 115/230 V AC J
MAG 5000, Polyamid, 11 ... 30 V DC/11 ... 24 V AC K
MAG 5000, Polyamid, 115/230 V AC L

4/70 Siemens FI 01 · 2009


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100
Selection and Ordering data Order No. Selection and Ordering data Order code
Sensor SITRANS F M MAG 3100 P 7 ME 6 3 4 0 - Additional information
77777 - 7777 Please add “-Z“ to Order No. and specify Order
code(s) and plain text.
Diameter
Tag name plate, stainless steel fixed with SS wire Y17
DN 15 (½“) 1V (add plain text)
DN 25 (1“) 2D
DN 40 (1½“) 2R Tag name plate, plastic (self adhesive) Y18

DN 50 (2“) 2Y Material certificate according to EN 10204 3.1 C12


(Pending)
DN 65 (2½“) 3F
DN 80 (3“) 3M Factory certificate according to EN 10204-2.1 C15
DN 100 (4“) 3T Factory certificate according to EN 10204-2.2 C14
DN 125 (5“) 4B Power cable wired (specify cable order no.) Y40
DN 150 (6“) 4H
Sensor for remote transmitter's junction box IP68 with Y41
DN 200 (8“) 4P wired cable (specify cable order no.) (no ATEX)
DN 250 (10“) 4V Customer specific test Y90
DN 300 (12“)
Flange norm and pressure rating
5D
Other postproduction requirements (add desired text) Y99 4
to EN 1092-1
PN 10 (DN 200 ... 300 (8“ … 12“)) B Please also see www.siemens.com/SITRANSFordering
PN 16 (DN 65 ... 300 (2½“ … 12”)) C for practical examples of ordering
PN 40 (DN 15 ... 50 (½“ … 2”) F MAG 5000/6000 transmitters and sensors are packed in sepa-
to ANSI B16.5 rate boxes, the final assembly takes place during installation at
Class 150 (½“ ... 12“) J the customer's place. MAG 6000 I/MAG 6000 I ATEX 2G D trans-
mitters and sensors are delivered compact mounted from fac-
Flange material
tory.
Carbon steel flanges ASTM A 105 1 Communication module will be pre-mounted in the transmitter.
Liner material
PTFE (130 °C (266 °F)) 3
PFA (150 ºC (302 ºF)) (DN 25, 50, 80, 100 7
(1", 2", 3", 4"))
Electrode material
Hastelloy C276 (PFA: Hastelloy C22) 2
Transmitter
Sensor for remote transmitter (Order transmitter A
separately)
Sensor ATEX 2G D for remote transmitter (Order B
transmitter separately)
MAG 6000 I, Aluminium, C
18 ... 90 V DC, 115 ... 230 V AC
MAG 6000 I, Aluminium, 18 ... 30 V DC, D
ATEX 2G D
MAG 6000 I, Aluminium, 115 ... 230 V AC, E
ATEX 2G D
MAG 6000, Polyamid, 11 … 30 V DC/11 ... 24V AC H
MAG 6000, Polyamid, 115/230 V AC J
MAG 5000, Polyamid, 11 ... 30 V DC/11 ... 24 V AC K
MAG 5000, Polyamid, 115/230 V AC L
Communication
No communication, add-on possible A
HART B
PROFIBUS PA Profile 3 F
(only MAG 6000/MAG 6000 I)
PROFIBUS DP Profile 3 (no ATEX) G
(only MAG 6000/MAG 6000 I)
MODBUS RTU/RS 485 (no ATEX) E
(only MAG 6000/MAG 6000 I)
FOUNDATION Fieldbus H1 J
(only MAG 6000/MAG 6000 I)
Cable glands/terminal box
Metric: Polyamid terminal box or 6000I compact 1
½" NPT: Polyamid terminal box or 6000I compact 2
Metric SS terminal box (mandatory for stainless 3
steel MAG 6000 transmitter)
½" NPT SS terminal box (mandatory for stainless 4
steel MAG 6000 transmitter)

Siemens FI 01 · 2009 4/71


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

Selection and Ordering data


MAG 3100 Type C Grounding and protection rings
7\SH&
AISI 304 grounding and protection rings type C for all liners except PTFE and PFA

W
W

DN PN 6 PN 10 PN 16 PN 25 PN 40 AS2129,
Table E
Order No. Order No. Order No. Order No. Order No. Order No.
DN 25 FDK-083N8361 FDK-083N8361
DN 40 FDK-083N8362 FDK-083N8362
DN 50 FDK-083N8344 FDK-083N8344
DN 65 FDK-083N8345 FDK-083N8345 FDK-083N8345 FDK-083N8346

4
DN 80 FDK-083N8347 FDK-083N8347 FDK-083N8347 FDK-083N8347
DN 100 FDK-083N8070 FDK-083N8025 FDK-083N8025 FDK-083N8025
DN 125 FDK-083N8071 FDK-083N8071 FDK-083N8071 FDK-083N8071
DN 150 FDK-083N8072 FDK-083N8008 FDK-083N8008 FDK-083N8008
DN 200 FDK-083N8074 FDK-083N8011 FDK-083N8011 FDK-083N8011 FDK-083N8075 FDK-083N8011
DN 250 FDK-083N8078 FDK-083N8013 FDK-083N8013 FDK-083N8013 FDK-083N8079 FDK-083N8013
DN 300 FDK-083N8080 FDK-083N8012 FDK-083N8012 FDK-083N8081 FDK-083N8082 FDK-083N8012
DN 350 FDK-083N8083 FDK-083N8039 FDK-083N8039 FDK-083N8084 FDK-083N8085 FDK-083N8039
DN 400 FDK-083N8099 FDK-083N8100 FDK-083N8100 FDK-083N8101 FDK-083N8102 FDK-083N8100
DN 450 FDK-083N8103 FDK-083N8103 FDK-083N8104 FDK-083N8104 FDK-083N8105 FDK-083N8104
DN 500 FDK-083N8107 FDK-083N8107 FDK-083N8108 FDK-083N8108 FDK-083N8109 FDK-083N8108
DN 600 FDK-083N8111 FDK-083N8111 FDK-083N8112 FDK-083N8112 FDK-083N8113
DN 700 FDK-083N8300 FDK-083N8294 FDK-083N8294 FDK-083N8372
DN 750 FDK-083N8366
DN 800 FDK-083N8303 FDK-083N8304 FDK-083N8304 FDK-083N8373
DN 900 FDK-083N8306 FDK-083N8307 FDK-083N8307 FDK-083N8396
DN 1000 FDK-083N8309 FDK-083N8310 FDK-083N8310 FDK-083N8397
DN 1100 FDK-083N8367 FDK-083N8367 FDK-083N8367
DN 1200 FDK-083N8312 FDK-083N8313 FDK-083N8313 FDK-083N8398
DN 1400 FDK-083N8467 FDK-083N8468 FDK-083N8469
DN 1500 FDK-083N8471 FDK-083N8472 FDK-083N8473
DN 1600 FDK-083N8475 FDK-083N8476 FDK-083N8477
DN 1800 FDK-083N8479 FDK-083N8480 FDK-083N8481
DN 2000 FDK-083N8483 FDK-083N8484 FDK-083N8485

Size ANSI Size AWWA C207


Class 150 Class 300
Order No. Order No. Order No.
1“ FDK-083N8361 FDK-083N8361 28“ FDK-083N8302
1½“ FDK-083N8362 FDK-083N8362 30“ FDK-083N8366
2“ FDK-083N8344 FDK-083N8344 32“ FDK-083N8305
2½“ FDK-083N8345 FDK-083N8345 36“ FDK-083N8308
3“ FDK-083N8347 FDK-083N8347 40“ FDK-083N8311
4“ FDK-083N8025 FDK-083N8025 42“ FDK-083N8394
5“ FDK-083N8071 FDK-083N8071 44“ FDK-083N8395
6“ FDK-083N8008 FDK-083N8073 48“ FDK-083N8314
8“ FDK-083N8011 FDK-083N8076 54“ FDK-083N8470
10“ FDK-083N8013 FDK-083N8079 60“ FDK-083N8474
12“ FDK-083N8012 FDK-083N8082 66“ FDK-083N8478
14“ FDK-083N8039 FDK-083N8085 72“ FDK-083N8482
16“ FDK-083N8100 FDK-083N8102 78“ FDK-083N8486
18“ FDK-083N8104 FDK-083N8106
20“ FDK-083N8107 FDK-083N8110
24“ FDK-083N8113 FDK-083N8114

4/72 Siemens FI 01 · 2009


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

Selection and Ordering data


MAG 3100, 3100 HT, MAG 3100 P Type E grounding and protection
ring 7\SH(
1 pc. AISI 316 grounding and protection rings type E for PTFE liners
Note:
For MAG 3100 HT High temperature version 7ME6320... for PTFE 180 °C
versions. - grounding ring type E is included and factory mounted.

W

DN PN 6 PN 10 PN 16 PN 25 PN 40
Order No. Order No. Order No. Order No. Order No.
DN 15 FDK-083N8365
DN 25 FDK-083N8271
DN 40 FDK-083N8278

4
DN 50 FDK-083N8282
DN 65 FDK-083N8284 FDK-083N8285 FDK-083N8286
DN 80 FDK-083N8288 FDK-083N8289 FDK-083N8290
DN 100 FDK-083N8116 FDK-083N8117 FDK-083N8118
DN 125 FDK-083N8120 FDK-083N8121 FDK-083N8122
DN 150 FDK-083N8124 FDK-083N8125 FDK-083N8126
DN 200 FDK-083N8129 FDK-083N8130 FDK-083N8130 FDK-083N8131 FDK-083N8132
DN 250 FDK-083N8135 FDK-083N8136 FDK-083N8137 FDK-083N8138 FDK-083N8139
DN 300 FDK-083N8144 FDK-083N8144 FDK-083N8145 FDK-083N8146 FDK-083N8147
DN 350 FDK-083N8152 FDK-083N8153 FDK-083N8154 FDK-083N8155 FDK-083N8156
DN 400 FDK-083N8160 FDK-083N8161 FDK-083N8162 FDK-083N8163 FDK-083N8164
DN 450 FDK-083N8168 FDK-083N8169 FDK-083N8170 FDK-083N8171 FDK-083N8172
DN 500 FDK-083N8177 FDK-083N8178 FDK-083N8179 FDK-083N8180 FDK-083N8181
DN 600 FDK-083N8186 FDK-083N8187 FDK-083N8188 FDK-083N8189
Protection of PTFE liner use 2 pcs.
Earthing of PTFE lined flowmeter use 1 pc.

Size ANSI AS2129, Table E


Class 150 Class 300 DN Order No.
Order No. Order No. DN 15 FDK-083N8365
½“ FDK-083N8365 FDK-083N8365 DN 25 FDK-083N8272
1“ FDK-083N8272 FDK-083N8272 DN 40 FDK-083N8280
1½“ FDK-083N8279 FDK-083N8279 DN 50 FDK-083N8281
2“ FDK-083N8283 FDK-083N8283 DN 65 FDK-083N8284
2½“ FDK-083N8287 FDK-083N8287 DN 80 FDK-083N8293
3“ FDK-083N8291 FDK-083N8292 DN 100 FDK-083N8117
4“ FDK-083N8118 FDK-083N8119 DN 125 FDK-083N8121
5“ FDK-083N8122 FDK-083N8123 DN 150 FDK-083N8128
6“ FDK-083N8126 FDK-083N8127 DN 200 FDK-083N8134
8“ FDK-083N8370 FDK-083N8133 DN 250 FDK-083N8143
10“ FDK-083N8140 FDK-083N8141 DN 300 FDK-083N8151
12“ FDK-083N8148 FDK-083N8149 DN 350 FDK-083N8153
14“ FDK-083N8157 FDK-083N8158 DN 400 FDK-083N8161
16“ FDK-083N8165 FDK-083N8166 DN 450 FDK-083N8176
18“ FDK-083N8173 FDK-083N8174 DN 500 FDK-083N8185
20“ FDK-083N8182 FDK-083N8183 DN 600 FDK-083N8193
24“ FDK-083N8190 FDK-083N8191 Protection of PTFE liner use 2 pcs.
Grounding of PTFE lined flowmeter use 1 pcs.
Protection of PTFE liner use 2 pcs.
Grounding of PTFE lined flowmeter use 1 pc.

Siemens FI 01 · 2009 4/73


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

Selection and Ordering data


MAG 3100, MAG 3100 HT, MAG 3100 P type E grounding and protecting ring
1 pc. Hastelloy C-276 grounding and protection ring type E for PTFE liners 7\SH(

W

DN PN 6 PN 16 PN 40 Size ANSI
Class 150 Class 300
Order No. Order No. Order No. Order No. Order No.
DN 15 FDK-083N8487 ½“ FDK-083N8487 FDK-083N8487
DN 25 FDK-083N8488 1“ FDK-083N8489 FDK-083N8489
DN 40 FDK-083N8490 1½“ FDK-083N8491 FDK-083N8491
4 DN 50 FDK-083N8492 2“ FDK-083N8493 FDK-083N8493
DN 65 FDK-083N8494 FDK-083N8495 FDK-083N8496 2½“ FDK-083N8497 FDK-083N8497
DN 80 FDK-083N8498 FDK-083N8499 FDK-083N8500 3“ FDK-083N8501 FDK-083N8502
DN 100 FDK-083N8503 FDK-083N8504 FDK-083N8505 4“ FDK-083N8506 FDK-083N8507

Selection and Ordering data


MAG 3100, MAG 3100 HT, MAG 3100 P Grounding rings: Flat rings
1 pc. AISI 316 grounding flat ring for all liners (not PTFE 180 ºC)

W PP LQFK
W

DN PN 10 PN 16 PN 40 Size ANSI
Class 150 Class 300
Order No. Order No. Order No. Order No. Order No.
DN 15 A5E01191969F) ½“ A5E01191968F)
DN 25 A5E01150880F) 1“ A5E01150022F) A5E01150378F)
DN 40 A5E01191952F) 1½“ A5E01191961F)
DN 50 A5E01150918F) 2“ A5E01151121F) A5E01151194F)
DN 65 A5E01191940F) A5E01191954F) 2½“ A5E01191962F)
DN 80 A5E01152876F) A5E01152876F) 3“ A5E01152910F) A5E01153422F)
DN 100 A5E01158875F) A5E01159072F) 4“ A5E01159146F) A5E01159628F)
DN 125 A5E01191941F) A5E01191956F) 5“ A5E01191963F)
DN 150 A5E01191943F) A5E01191957F) 6“ A5E01191964F)
DN 200 A5E01191951F) A5E01191944F) A5E01191958F) 8“ A5E01191965F)
DN 250 A5E01191950F) A5E01191946F) A5E01191959F) 10“ A5E01191966F)
DN 300 A5E01191949F) A5E01191947F) A5E01191960F) 12“ A5E01191967F)

F) Subject to export regulations AL: 9I999, ECCN: N.

4/74 Siemens FI 01 · 2009


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

Selection and Ordering data


MAG 3100, MAG 3100 HT, MAG 3100 P Grounding rings : Flat rings
1 pc. Hastelloy C-276 grounding flat ring for all liners (not PTFE 180 ºC)

W PP LQFK
W

DN PN 10 PN 16 PN 40 Size ANSI
Class 150 Class 300
Order No.F) Order No.F) Order No.F) Order No.F) Order No.F)
DN 15 A5E01191981 ½“ A5E01191989
DN 25 A5E01150882 1“ A5E01150028 A5E01150379
DN 40 A5E01191982 1½“ A5E01191990
DN 50 A5E01150922 2“ A5E01151124 A5E01151197 4
DN 65 A5E01191971 A5E01191983 2½“ A5E01191991
DN 80 A5E01152889 A5E01152889 3“ A5E01152913 A5E01153424
DN 100 A5E01158886 A5E01159074 4“ A5E01159150 A5E01159629
DN 125 A5E01191973 A5E01191984 5“ A5E01191992
DN 150 A5E01191974 A5E01191985 6“ A5E01191993
DN 200 A5E01191978 A5E01191975 A5E01191986 8“ A5E01191994
DN 250 A5E01191979 A5E01191976 A5E01191987 10“ A5E01191995
DN 300 A5E01191980 A5E01191977 A5E01191988 12“ A5E01191996

Selection and Ordering data


MAG 3100, MAG 3100 HT, MAG 3100 P Grounding rings : Flat rings
1 pc. Tantalum grounding flat ring for all liners (not PTFE 180 ºC)

W PP LQFK
W

DN PN 16 PN 40 Size ANSI
Class 150 Class 300
Order No.F) Order No.F) Order No.F) Order No.F)
DN 15 A5E01192007 ½“ A5E01192010
DN 25 A5E01150883 1“ A5E01150030 A5E01150381
DN 40 A5E01192008 1½“ A5E01192011
DN 50 A5E01150926 2“ A5E01151129 A5E01151199
DN 65 A5E01192005 A5E01192009 2½“ A5E01192012
DN 80 A5E01152890 A5E01152890 3“ A5E01152916 A5E01153427
DN 100 A5E01158891 A5E01159076 4“ A5E01159156 A5E01159631

F) Subject to export regulations AL: 9I999, ECCN: N.

Siemens FI 01 · 2009 4/75


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100

■ Dimensional drawings
MAG 3100, MAG 3100 HT, MAG 3100 P sensor with compact or remote transmitter

       

6,75$16)00$*)/20$*,1'8675<
&RGHQR)'.)
6HULDOQR
)LUPZDUHYHUVLRQ
6XSSO\
(QFORVXUH 
7HPS$PE 
 
6,5$$7(;;
,,  *

(([GH>LD@LD,,%7
,6,17(5)$&(
6HHPDQXDO
[0
6LHPHQV)ORZ,QVWUXPHQWV$6
0DGHLQ'HQPDUN

 
0
1373* $  $

$
'

'
4

% %
/ 7( 7& ' / 7( 7
&

Metric
DN A1) A1/A28) B D1 L2) TC3) TE3) Weight4)
EN 1092-1-201 ANSI 16.5 AS 2129 E AWWA
PN 6, 10 PN 16/ PN PN PN PN Class Class AS 4087 C-207
PN 16 non 25 40 63 100 150 300 PN 16, 21, Class D
PED 35
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [kg]
15 187 338 59 104 - - - 200 - - 200 200 200 - - 6 4
25 187 338 59 104 - - - 200 - 260 200 200 200 - 1.2 6 5
40 197 348 82 124 - - - 200 - 280 200 200 200 - 1.2 6 8
50 205 356 72 139 - - - 200 276 300 200 200 200 - 1.2 6 9
65 212 363 72 154 200 200/- - 200 320 350 200 272 200 - 1.2 6 11
80 222 373 72 174 200 200/- - 272 323 340 272 272 2005) - 1.2 6 12
100 242 393 85 214 250 250/- - 250 380 400 250 310 250 - 1.2 6 16
125 255 406 85 239 250 250/- - 250 420 450 250 335 250 - 1.2 6 19
150 276 427 85 282 300 300/- - 300 415 450 300 300 300 - 1.2 6 27
200 304 455 137 338 350 350/- 350 350 480 530 350 350 350 - 1.2 8 40
250 332 483 157 393 450 450/- 450 450 550 620 450 450 450 - 1.2 8 60
300 357 508 157 444 500 500/- 500 500 600 680 500 500 500 - 1.6 8 80
350 362 513 270 451 550 550/- 550 550 - - 550 550 550 - 1.6 8 110
400 387 538 270 502 600 600/- 600 600 - - 600 600 600 - 1.6 10 125
450 418 569 310 563 600 600/- 600 600 - - 600 600 600 - 1.6 10 175
500 443 594 350 614 600 600/- 625 680 - - 600 730 6006) - 1.6 10 200
600 494 645 430 715 600 600/- 750 800 - - 600 860 6007) - 1.6 10 287
700 544 695 500 816 700 875/700 - - - - - - 700 700 2.0 - 330
750 571 722 556 869 - -/- - - - - - - 750 750 2.0 - 360
800 606 757 560 927 800 1000/800 - - - - - - 800 800 2.0 - 450
900 653 804 630 1032 900 1125/900 - - - - - - 900 900 2.0 - 530
1000 704 906 670 1136 1000 1250/1000 - - - - - - 1000 1000 2.0 - 660
1100 755 906 770 1238 - -/- - - - - - - 1100 1100 2.0 - 1140
1200 810 961 792 1348 1200 1500/1200 - - - - - - 1200 1200 2.0 - 1180
1400 925 1076 1000 1675 1400 -/1400 - - - - - - - 1400 2.0 - 1600
1500 972 1123 1020 1672 1500 -/1500 - - - - - - - 1500 3.0 - 2460
1600 1025 1176 1130 1915 1600 -/1600 - - - - - - - 1600 3.0 - 2140
1800 1123 1274 1250 1974 1800 -/1800 - - - - - - - 1800 3.0 - 2930
2000 1223 1374 1375 2174 2000 -/2000 - - - - - - - 2000 3.0 - 3665
1) 5)
14.5 mm shorter with AISI terminal box (Ex and high temperature version) PN 35 DN 80 = 272 mm
2) 6)
When earthing flanges are used, the thickness of the earthing flange must PN 35 DN 500 = 680 mm
be added to the build-in length 7)
PN 35 DN 600 = 750 mm
3) 8)
TC = Type C grounding ring, TE = Type E grounding ring (Included and fac- A2 is 3 mm/0.12“ shorter than A1
tory mounted on high temperature 180 °C (356 °F) PTFE sensor) - not available
4)
Weights are approx. (for PN 16) without transmitter D = Outside diameter of flange, see flange tables

4/76 Siemens FI 01 · 2009


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
MAG 3100
MAG 3100, MAG 3100 HT, MAG 3100 P sensor with compact or remote transmitter
Imperial
Size A1) A1/A28) B D1 L2) AS 2129 E TC3) TE3) Weight4)
AS 4087
EN 1092-1-201 ANSI 16.5 AWWA PN 16, 21,
C-207 35
PN 6, PN 16/ PN PN PN PN Class Class Class D
10 PN 16 non 25 40 63 100 150 300
PED
[inc [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [in.] [in.] [lb]
h]
½ 7.36 13.31 2.32 4.09 - - - 7.87 - - 7.87 7.87 - 7.87 - 0.24 11
1 7.36 13.31 2.32 4.09 - - - 7.87 - 10.24 7.87 7.87 - 7.87 0.05 0.24 13
1½ 7.76 13.70 3.23 4.88 - - - 7.87 - 11.02 7.87 7.87 - 7.87 0.05 0.24 17
2 8.07 14.01 2.83 5.47 - - - 7.87 10.87 11.81 7.87 7.87 - 7.87 0.05 0.24 28
2½ 8.35 14.29 2.83 6.06 7.87 7.87/- - 7.87 12.60 13.78 7.87 10.71 - 7.87 0.05 0.24 30
3
4
8.74
9.53
14.69
15.47
2.83
3.35
6.85
8.43
7.87
9.84
7.87/-
9.84/-
-
-
10.71 12.72 13.39 10.71 10.71 -
9.84 14.96 - 9.84 12.20 -
7.875)
9.84
0.05 0.24 33
0.05 0.24 44
4
5 10.04 15.98 3.35 9.41 9.84 9.84/- - 9.84 16.54 - 9.84 13.10 - 9.84 0.05 0.24 55
6 10.87 16.81 5.39 11.10 11.81 11.81/- - 11.81 16.34 - 11.81 11.81 - 11.81 0.05 0.24 66
8 11.97 17.91 5.39 13.31 13.78 13.78/- 13.78 13.78 18.90 - 13.78 13.78 - 13.78 0.05 0.31 110
10 13.07 19.02 6.18 15.47 17.72 17.72/- 17.72 17.72 - - 17.72 17.72 - 17.72 0.05 0.31 155
12 14.05 20.00 6.18 17.48 19.69 19.69/- 19.69 19.69 - - 19.69 19.69 - 19.69 0.06 0.31 176
14 14.25 20.20 10.63 17.76 21.65 21.65/- 21.65 21.65 - - 21.65 21.65 - 21.65 0.06 0.31 242
16 15.24 21.18 10.63 19.76 23.62 23.62/- 23.62 23.62 - - 23.62 23.62 - 23.62 0.06 0.39 275
18 16.45 22.40 12.20 22.16 23.62 23.62/- 23.62 23.62 - - 23.62 23.62 - 23.62 0.06 0.39 385
6)
20 17.44 23.39 13.78 24.17 23.62 23.62/- 24.61 26.77 - - 23.62 28.70 - 23.62 0.06 0.39 335
24 19.45 25.39 16.93 28.15 23.62 23.62/- 29.53 31.50 - - 23.62 33.80 - 23.627) 0.06 0.39 630
28 21.42 27.36 19.69 32.13 27.56 34.45/27.56 - - - - - - 27.56 27.56 0.08 - 725
30 22.48 28.43 21.89 34.21 - -/- - - - - - - 29.52 - 0.08 - 830
32 23.86 29.80 22.05 36.50 31.50 39.37/31.50 - - - - - - 31.50 31.50 0.08 - 990
36 25.71 31.65 24.80 40.63 35.43 44.29/35.43 - - - - - - 35.43 35.43 0.08 - 1160
40 27.72 35.67 26.38 44.72 39.37 49.21/39.37 - - - - - - 39.37 39.37 0.08 - 1453
42 27.72 35.67 26.38 44.72 - -/- - - - - - - 39.37 - 0.08 - 1453
44 29.72 35.67 30.31 48.74 - -/- - - - - - - 43.31 43.31 0.08 - -
48 31.89 37.83 31.18 53.07 47.24 59.06/47.24 - - - - - - 47.24 47.24 0.08 - 2592
54 36.42 42.36 39.37 65.94 55.12 -/55.12 - - - - - - 55.12 - 0.12 - 2940
60 38.27 44.21 40.15 65.83 59.06 59.06/59.06 - - - - - - 59.06 - 0.12 - 3422
66 40.35 46.30 44.49 75.39 62.99 -/62.99 - - - - - - 63.00 - 0.12 - 3904
72 44.21 50.16 49.21 77.72 70.87 -/70.87 - - - - - - 70.87 - 0.12 - 4846
78 48.15 54.09 54.13 85.59 78.74 -/78.74 - - - - - - 78.74 - 0.12 - 6806
1)
0.512 inch shorter with AISI terminal box (Ex and high temperature version)
2) When earthing flanges are used, the thickness of the earthing flange must be added to the build-in length
3)
TC = Type C grounding ring, TE = Type E grounding ring (Included and factory mounted on high temperature 180 °C (356 °F) PTFE sensor)
4)
Weights are for ANSI 150 without transmitter
5)
PN 35 DN 80 = 10.70 inch
6)
PN 35 DN 500 = 26.77 inch
7)
PN 35 DN 600 = 29.53 inch
8)
A2 is 0.06“ shorter than A1
- not available
D = Outside diameter of flange, see flange tables

Siemens FI 01 · 2009 4/77


© Siemens AG 2008

SITRANS F flowmeters
SITRANS F M
Sensor calibration

Selection and Ordering data


Product designation Order No.
SITRANS F M - Electromagnetic flowmeters
Calibrations/recalibration for
MAG 1100, 1100 F, 5100 W and 3100
Accessories for SITRANS F M FDK -
Calibration O.R.2)
Standard Production calibration
• Zero-point 2 x 25 %, 2 x 90 % -
MAG 8000 calibration
• Zero-point 1 x 25 %, 1 x 100 % -
Standard production calibration -
Matched pair
Size < DN 350 (14") O.R.
Size DN 300 ... 1200 (12“ ... 48") O.R.
4 Larger sizes O.R.
Customer specified calibration up to
10 point1)
Size ≤ DN 150 (6“) O.R.
Size DN 200 ... 300 (8“ ... 12“) O.R.
Size DN 350 ... 600 (14“ ... 24“) O.R.
Size DN 700 ... 1100 (28“ ... 48“) O.R.
Add-on: Matched pair of any above O.R.
Larger sizes O.R.
Accredited calibration ISO/IEC 17025 -
Matched pair1)
Accredited calibration report with up
to 21 points1)
Size ≤ DN 150 (6“) O.R.
Size DN 200 ... 300 (8“ ... 12“) O.R.
Size DN 350 ... 600 (14“ ... 24“) O.R.
Size DN 700 ... 1100 (28“ ... 48“) O.R.
Larger sizes O.R.
CT-calibration and authority seal
Up to DN 300 (12“) for PTB and DANAK
Size ≤ DN 150 (6“) O.R.
Size DN 200 ... 300 (8“ ... 12“) O.R.
Larger sizes O.R.
Customer witnessed calibration
Any of above calibration
Add-on price per sensor O.R.
Size DN 200 ... 300 (8“ ... 12“)
Daily rates available on request for larger
project.
1) Size dependent restriction on maximum 42,682 flow rates may apply.
2)
Ordering O.R. As we need dedicated information from the customer on the
individual sensor, we must have the calibration forms filed and sent
together with the order.

4/78 Siemens FI 01 · 2009