Vibration Record
Vibration Record
Vibration Record
INSPECTION CHECKSHEET
Vibration Data Record
(As Left)
8 hours
trending
20-04-19 14:08 3002 FSNL 0.518 1.042 1.686 1.926 2.450 1.004
20-04-19 18:59 3004 40MW 1.026 1.293 1.457 4.087 3.656 0.748
21-04-19 2:59 3011 45MW 0.993 1.370 1.479 3.481 3.547 0.900
21-04-19 11:09 3006 75MW 1.108 1.424 2.161 4.578 4.153 1.075
21-04-19 19:00 3015 80~85MW 1.102 1.304 2.690 4.775 3.334 1.632
22-04-19 3:01 3014 80~85MW 1.151 1.337 2.614 5.080 2.952 1.659
22-04-19 11:13 3008 80~85MW 1.097 1.381 2.652 4.873 3.263 1.544
22-04-19 20:00 3009 80~85MW 1.228 1.375 2.734 5.026 3.078 1.582
23-04-19 4:00 3010 80~85MW 1.200 1.473 2.761 5.091 2.952 1.626
23-04-19 12:10 3006 80~85MW 1.173 1.451 2.646 4.720 3.514 1.632
Info:
ISO 10816-2 (mm/s RMS) LMZ 110MW Steam Turbine (µm pk-pk) Bearing 1,2 Bearing 3,4 Critical speed
A: Vibration < 3.8 Very Good < 15µm < 20µm Critical speed 1 : 1,670rpm
B: 3.8 < Vibration < 7.5 Good 15 ~ 20µm 20 ~ 32µm Critical speed 2 : 1,899rpm
C: 7.5 < Vibration < 11.8 Satisfying during the latest overhaul, will fix the vibration correction. 20 ~ 25µm 32 ~ 40µm Critical speed 3 : 2,405rpm
D: Vibration > 11.8 Allow to operate for 5 days and nights, to be repaired for better vibration. 25 ~ 32µm 40 ~ 60µm Critical speed 4 : 4,991rpm
Alarm: 4.0mm/s + (25%x7.5mm/s) You need to stop the turbine to correct the vibration. > 32µm > 60µm
= 5.9mm/s Alarm: 25µm 40µm