Anugrah Raya: Shear Connector

Shear connectors are used in composite steel construction to tie concrete to steel members and resist shear forces between them. They are typically welded studs that ensure the bending resistance of beam and plate members when loaded vertically. Anugrah Raya shear connectors meet various international standards and have mechanical properties including tensile and yield strengths. They are available in different diameters and lengths with ferrule options for various applications like composite building construction, embedding in concrete, and modern bridge building where they enable a stronger and more economical structure.

Uploaded by

dede
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
164 views6 pages

Anugrah Raya: Shear Connector

Shear connectors are used in composite steel construction to tie concrete to steel members and resist shear forces between them. They are typically welded studs that ensure the bending resistance of beam and plate members when loaded vertically. Anugrah Raya shear connectors meet various international standards and have mechanical properties including tensile and yield strengths. They are available in different diameters and lengths with ferrule options for various applications like composite building construction, embedding in concrete, and modern bridge building where they enable a stronger and more economical structure.

Uploaded by

dede
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 6

Anugrah Raya Shear Connector

Shear connectors also named shear studs,


concrete anchors, are typically used in
composite steel construction to tie the concrete
to steel members and resist shear forces
between the concrete slab and steel members.
They are widely used in steel building, bridges,
etc. Welding Through Metal Deck are available
for this stud, for this option, special ceramic
ferrule type UF are recommended.

The Working principle when the beam and the


plate are bent under the vertical load, the
shearing force (horizontal direction) of the axial
surface is the largest, and the overlapping
surface of the laminated beam and the plate
member is located there (or close to the vicinity),
and many are arranged. The shearing nail is
used to resist the shearing force to ensure the
normal bending resistance of the beam and the
plate.

Download Cataloq
Anugrah Raya shear connectors meet the following standards:
1. AWS D1.1 Section 7 – Structural Welding Code
2. AASHTO/AWS D1.5 Section 7 – Bridge Welding Code
3. ISO 13918
4. JIS B1198

Mechanical Property :

Yield Reduction
Tensile Elongation
Standard Strenght Of Area
Strenght Min.
Min. Min.
AWS D1.1 Min. 65.000 psi / 51.000 psi /
20% 50%
Sect.7 Min. 450 MPA 350 MPA
AASHTO/AWS Min. 60.000 psi / 50.000 psi /
20% 50%
D1.5 Sect.7 Min. 415 MPA 345 MPA
ISO 13918 450 - 600N/mm² 350 N/mm² 15% (A5) 50%
400 - 550
JIS B1198 235 N/mm² 20% 50%
N/mm²
Stud Material : ASTM A29 (A108) Grades 1010 – 1020
Stud Dia. ( D ) Length ( L ) Part No. A H Ferrule
50 mm 200-013-050
75 mm 200-013-075
13 mm
100 mm 200-013-100 8 mm 25 mm 100-013-007
( 1/2 Inch )
125 mm 200-013-125
150 mm 200-013-150
75 mm 200-016-075
100 mm 200-016-100
16 mm 100-016-007
125 mm 200-016-125 8 mm 32 mm
( 5/8 Inch ) 100-016-009**
150 mm 200-016-150
175 mm 200-016-175
75 mm 200-019-075
90 mm 200-019-090
100 mm 200-019-100
100-019-007
19mm 115 mm 200-019-115
10 mm 32 mm 100-016-008*
( 3/4 Inch ) 125 mm 200-019-125
100-016-009**
150 mm 200-019-150
175 mm 200-019-175
200 mm 200-019-200
75 mm 200-022-075
100 mm 200-022-100
125 mm 200-022-125
22 mm
150 mm 200-022-150 10 mm 35 mm 100-022-007
( 7/8 Inch )
175 mm 200-022-175
200 mm 200-022-200
250 mm 200-022-250
75 mm 200-025-075
100 mm 200-025-100
125 mm 200-025-125
25,4 mm
150 mm 200-025-150 12.7 mm 41 mm 100-025-007
( 1 Inch )
175 mm 200-025-175
200 mm 200-025-200
250 mm 200-025-250
* Ferrule for Weld-thru Deck Application
** Ferrule for Vertical Surface Application
APPLICATION OF SHEAR CONNECTOR INSTALLATION

Composite Construction
Building
Steel beam and reinforced concrete slab joined by AR shear connector give action as a beam
structures produce load bearing efficiently that combined strength of steel and concrete slab. It
allow longer span with thinner and lighter floor, which provide great cost saving in entire
construction expenses. AR shear connectors can be welded throughmetal decks, which secure
the decks to the beam and also the beam to reinforced concrete slab with the studs producing
all three structural members act as a strong unit.
Embedment
Concrete Shear connector studs and other various studs can be welded to steel plate, steel
angle, channel steel and other large steel weld ments to serve as for joining steel liners to
concrete surroundings

Bridge
Modern bridge to be built requires strong structural strength bearing load from heavy traffic
passings. Shear connector serves for such bridge enable to make it more strong and
economically.
The structure of compositebeam widely used for building bridge consists of steel beam nd
reinforced concrete slab joined by AR shear connector, so that the steel and concrete act as a
unit to bear the bending stress.
If the same load is to be born, the composite beam allows smaller sectional area, the composite
bem bears heavier load than non-composite beam .