Analog Addressable
Control Panels
Technical Manual
Note
i Do not install, operate, and maintain this product before fully reading this
manual.
1 Introduction
The RM-4005 Remote Panel and Annunciator enables control and supervision of the
ADR-3000 fire alarm control panel from remote locations and key positions such as
security officer, premises manager, or maintenance office.
The RM-4005 remote panel consists of an LCD display, keyboard, internal buzzer, and
features such as alarm output, trouble output, and an interface relay that reduces the
need for additional input/output interface modules.
The remote panels are connected to the main control panel via a twisted wire pair
(RS-485). As many as 16 remote panels can be connected to the control panel using
the same cable. Each remote panel should be configured with a unique address in the
range of 1 to 16. The communication and input/output circuits are fully supervised.
In large systems incorporating several control panels connected via a peer-to-peer
network as many as 16 remote panels can be connected to each of the control panels.
The RM-4005 operates with a 24Vdc power source that can be supplied from one of the
following options:
• 24Vdc supplied from the main control panel ADR-3000(connector TB11)
• 24Vdc supplied from a remote power supply such as Telefire's TPS-34A Analog
Addressable External Power Supply.
• (SILENCE) – Press this key silence the alarm bells or the trouble buzzer. In
order to activate this feature, an access code is required. This code will enable only
authorized personnel to silence the alarm.
– Page 1 of 5 –
RM-4005
© 1999 – 2013 Telefire Fire & Gas Detectors Ltd Revision 1.22 March 2013
• RECALL MEMORY – Press this key to scan all the system’s events, when more
than one event occurring simultaneously.
• ARROWS – The 4 arrows enable navigating between the menus displayed on the
screen.
• NUMERICAL KEYBOARD – Enables to enter codes, numbers and the selection of
menus.
– Page 2 of 5 –
RM-4005
© 1999 – 2013 Telefire Fire & Gas Detectors Ltd Revision 1.22 March 2013
The alarm and trouble outputs are supervised and operate on level-activating mode
delivering 24Vdc during alarm or trouble condition.
5 Operating Instructions
5.1 Recall Memory
Whenever more than one event occurs simultaneously in the ADR-3000 system and the
first event is displayed on the screen, it is possible to scroll in order to display the
previous events by using the recall memory push button.
5.5 Reset
Whenever alarm event occur its possible make a Reset from RM-4005.
1. Press asterisk key ( * ) and select key 5 "Reset"
2. Enter a password
3. Press key 6 for quit from menu
6 Fuses
The following fuses are being used in the RM-4005 Remote Panel:
Fuse Rating Function
F1 0.5A Protects the 24 Vdc outputs
F2 0.1A Protects the LCD display’s illuminating circuit
Note
i In addition to fuse protection both the alarm output (AL) and trouble output
(TR) are protected electronically against short circuit and over-current.
– Page 3 of 5 –
RM-4005
© 1999 – 2013 Telefire Fire & Gas Detectors Ltd Revision 1.22 March 2013
8 Operating Modes
8.1 Alarm Mode
During an alarm the alarm red LED will latch On and the following information will be
displayed:
The event’s number, time of occurrence, description (up to 40 characters, IDC type, and
total event count (if there is more than one event).
– Page 4 of 5 –
RM-4005
© 1999 – 2013 Telefire Fire & Gas Detectors Ltd Revision 1.22 March 2013
9 Specification
Dimensions (W / H / D) ................................................. 280 / 195 / 50 mm
Weight .......................................................................... 1,535 gr.
Operating Temperature Range ..................................... -10°C – +60°C (14°F – 140°F)
Relative Humidity Range .............................................. 10% – 93% non-condensing
Operating Voltage ......................................................... 24Vdc
Current Consumption
Quiescence mode, LCD not illuminated ................. 40 mA
Alarm, excluding external sounder current ............. 70 mA
Maximum Alarm output current ..................................... 500 mA
Maximum Trouble output current .................................. 500 mA
All values are nominal. Specifications are subject to change without prior notice
10 Certification
Telefire’s RM-4005 Analog Addressable Conventional Remote Panel and Annunciator
has the following approvals:
• SI 1220 Approved
• EN-54 Approved
• UL 864 Compliant