12 Chapter 4
12 Chapter 4
12 Chapter 4
CHAPTER 4
4.1 GENERAL
Type PowerMag
Cooling Air
Load measurement method Strain gauge
Maximum speed 3000 rpm
BHP 5HP
Coupling type Direct
60
Percentage
Sl.No Parameter/Instrument Range Accuracy
Uncertainties
1 Engine speed 1400-1600 rpm ± 2 rpm ±1.0
2 Temperature 0-800oC ±1 oC ±0.1
3 Pressure 0-100bar ±0.5bar ±0.1
4 Load 0-100kg ±0.1kg ±0.2
5 Fuel measurement - ±0.2cm3 ±1.5
6 Manometer - ±1mm ±1.0
7 Crank angle encoder - ±1o ±0.2
8 NOX 0-12000 ppm ±15 ppm ±0.2
9 HC 0-15000ppm ±1 ppm ±0.2
10 CO 0-10% ±0.01 ±0.1
Eddy current
Dynamometer
An acrylic body rota meter is used to measure water flow with a range
40-400 LPH for engine cooling and 10-100 LPH for calorimeter cooling.
Signal
Range
Type o conditioning / Location
( C)
transmitter
K 0-300 Inlet water temperature in calorimeter
K 0-300 Outlet water temperature in calorimeter
K 0-1500 Inlet exhaust gas temperature in calorimeter
K 0-1500 Standalone Outlet exhaust gas temperature in calorimeter
K 0-300 Inlet water temperature to the engine cylinder
Outlet water temperature from the engine
K 0-300
cylinder
K 0-300 Ambient temperature
63
Calorimeter
General specifications
Pulse count (ppr) 360
Electrical specifications
Operating voltage 5V DC ±5%
No load current supply Max 70mA
Output
Output type Pulse
Operating current Max.per channel20mA
Output frequency Max.200MHz
Rise time 100ns
Connection
Connector Type 9416, 12-pin,
pin, type 9416L, 12-pin
12
Ambient conditions
Operating temperature 253 to 333K
Storage temperature 233 to 343K
Mechanical Specifications
Rotational speed Max 12000min-1
Moment of Inertia ≤ 25gcm2
Starting torque ≤ 1.5Ncm
65
CO 0 – 10 % Volume 0.01%
O2 0 – 25 % Volume 0.01%
The following Table 4.8 contains the emission standards for the
Euro emission standards for heavy duty diesel engines. In this smoke emission
is given in m-1.
Table 4.8 Euro union emission standards for heavy duty diesel engines,
g/kWh
The following experiments are carried out to meet out the objective
4.12 SUMMARY