0% found this document useful (0 votes)
48 views3 pages

Fatigue

The document provides calculations to check the flexural and shear resistance of a composite bridge section. For flexure, it calculates the yield moment of the top and bottom flanges, additional yield moment, and nominal flexural resistance based on these values. It then checks that the factored flexural demand is less than the nominal resistance. For shear, it calculates the web classification, shear buckling coefficient, nominal shear resistance, and checks that the factored shear demand is less than the nominal resistance. In both cases, the demands are found to be less than the resistances.

Uploaded by

fakhri ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views3 pages

Fatigue

The document provides calculations to check the flexural and shear resistance of a composite bridge section. For flexure, it calculates the yield moment of the top and bottom flanges, additional yield moment, and nominal flexural resistance based on these values. It then checks that the factored flexural demand is less than the nominal resistance. For shear, it calculates the web classification, shear buckling coefficient, nominal shear resistance, and checks that the factored shear demand is less than the nominal resistance. In both cases, the demands are found to be less than the resistances.

Uploaded by

fakhri ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Pt = B x t3 x Fy

Pw =h1 x t4 x Fy x 2

Pc = B1 X t1 x 2

Ps = 0.85 x Fc’ x bs x ts

Pt 16800000 N
Pw 38833080 N
Pc 6300000 N
Prb 0 N
Prt 0 N
Ps 26190625 N

i. jika di web
55633080.22 > 32490625 di web

Dcp = 792.6094264 mm

= + − + [ + + + ]
2

Mp 94886538269 N.mm
▪ Yield Moment(My) (AASHTO LRFD Bridge, 2012, D6.2.2)
① Yield Moment of Top Flange
MD1 MD2 + MAD 2.440E+10 2.284E+10 MAD
Fy = + = + + = 350
S Top S Top(3n) S Top(n) 1.113E+08 3.549E+08 3.926E+08
MAD = 2.487E+11 N·mm
MyTop = MD1 + MD2 + MAD = 2.960E+11 N·mm

② Yield Moment of Bottom Flange


MD1 MD2 MAD 2.440E+10 2.284E+10 MAD
Fy = + + = + + = 350
S Bot S Bot(3n) S Bot(n) 1.585E+08 2.088E+08 2.172E+08
MAD = 18839253210.470 N·mm
MyBot = MD1 + MD2 + MAD = 6.608E+10 N·mm

∴ My = min ( MyTop, MyBot ) = 6.608E+10 N·mm


in which :
3
S : noncomposite section modulus (mm )
3
S 3n : long-term composite section modulus (mm )
3
Sn : short-term composite section modulus (mm )
MD1 : moment of noncomposite section (kN·m)
MD2 : moment of long-term composite section (kN·m)
MAD : additional yield moment of short-term composite section (kN·m)

▪ Flexural Resistance of Composite compact section (AASHTO LRFD Bridge, 2012, 6.10.7.1.2)
ⅰ. Nominal Flexural Resistance in a continuous span
Mn1 = 1.3 Rh · My = 85897647173.611 N·m
ⅱ. Nominal Flexural Resistance by D p
D p > 0.1D t therefore,
Dp
Mn2 = Mp ( 1.07 - 0.7 ) = 77378839138.130 N.mm
Dt

∴ Mn = min ( Mn1, Mn2 ) = 77378839138.130 N.mm

▪ Check Flexural Resistance of Composite compact section (AASHTO LRFD Bridge, 2012, 6.11.7.1)

Muy = 76237686000.000 ≤ Ф f · Mn = 77378839138.130 N.mm ...... OK

in which :
Muy = 76237686000.000 N·mm
Фf = 1.000
Ratio = 0.985252
2) Shear Resistance (AASHTO LRFD Bridge, 2012, 6.10.9)
▪ Ratio of the shear-buckling resistance to the shear yield strength, C (AASHTO LRFD Bridge, 2012, 6.10.9.3.2)
▪ Web Classification
Longitudinal Stiffener :
Transverse Stiffener :
Transverse Spacing = 2000.0 mm < 3D = 8411.4 mm
So, this web is considered stiffened web

shear-buckling coefficient of stiffened Webs


5
k = = 14.827
5+ d0 2
( )
D

D E·k
= 155.766 > 1.40 √ = 128.863
tw Fyw
therefore,
1.57 ·( E·k )=
C = 2
0.677
( D ) Fyw
tw

▪ Nominal Resistance of Stiffened interior Webs (AASHTO LRFD Bridge, 2012, 6.10.9.3.2)
Vp = 0.58Fyw · D · =
tw 11383.393 kN
2D · tw
= 0.825 ≤ 2.500
( bfc · tfc + bft · tft )
therefore,
0.87(1-C)
Vn = V p[ C+ d0 2
]= 10905.132 kN
√ 1+( )
D
V ui = 3824.552 ≤ Фv · V n = 10905.132 kN ...... OK
in which :
Фv = 1.000
Ratio = 0.3507112