Distribution Line Fault Detection and Intimation Using GSM PDF
Distribution Line Fault Detection and Intimation Using GSM PDF
USING GSM
Shunmugam.R1,
Ashok kumar.K 2, Deebika Devi .A.R3, Manoj Kumar .K4, Mathivanan .A.M5
1
Atssociate professor,Electrical And Electronics Engineering,
Kathir College of Engineering,
2,3,4,5
Electrical And Electronics Engineering ,Kathir College of Engineering
Abstract- This project is locating fault in a power distribution line is a complicated and severe
problem in power system. This is designed with micro controller, GSM mobile, Driver circuit,
control circuit interfaced with GSM modem. It is useful for remote monitoring and control of
multiple stand-alone distribution transformers plants. In normal conditions, the system records and
periodically reports the overall performances, whereas, in case of incorrect behaviours , it
immediately informs the operators. Moreover, through appropriate instructions, users are able to
modify some elements of the plant and the settings of the measurement system.In order to adapt the
system to the specific operative conditions, several means of communications and plant
configurations. The work described is a development of Microcontroller-based Protection of Electric
Distribution system for the purpose of effective monitoring and sending information of distribution
system. However, for a more general, flexible and cost-effective implementation, the remote
communications are based on a powerful GSM networking is designed when the voltage through the
line falls below a programmed voltage, an immediate indication is provided by the microcontroller
through the GSM modem. The interfaced GSM modem will receive the signal and to send data from
Distribution side to the substation and to the line patrol staffs as a message.
Keywords:Microcontroller,GSM,Remote Monitoring
I. INTRODUCTION
The consumption of electricity is increasing at much faster rate. Losses in distribution system are
much higher than losses in transmission side and also fault are more frequent in distribution side.
The survey indicates that 80% of the consumer’s service interruptions are due to failures in
distribution networks. Detecting and locating fault in power line is very necessary for healthy
operation of power system. In distribution line multiple faults detection and indication to Electricity
Board (EB) deals with the problem of detecting the fault in the transmission lines and the automatic.
Intimation to EB. This project deals with the design and fabrication of power supply, microcontroller
and Global System for Mobile Communication(GSM) modem. This proposes greatly reduces the
manpower, saves time and operates efficiently without human interference.
UNO transmits data to control panel or substation so that immediate action can be done with the help
of GSM technology.
2.1TYPES OF FAULTS
The design of systems to detect and interrupt power system faults is the main objective of power-
system protection. The faults can be divided into Seven types. They are shown below.,
a. Transient fault
b. Symmetric fault
c. Asymmetric fault
(a).Transient fault
A transient fault is a fault that is no longer present if power is disconnected for a short time and then
restored; or an insulation fault which only temporarily affects a device’s dielectric properties which
are restored after a short time. Many faults in overhead power lines are transient in nature. When a
fault occurs, equipment used for power system protection operate to isolate the area of the fault.
(b).Symmetric Fault
A symmetric or balanced fault affects each of the three phases equally. In transmission line
faults,roughly 5% are symmetric. This is in contrast to an asymmetrical fault, where the three phases
are not affected equally.
microcontroller interact with the power lines and sends message what kind of fault held in the line
through the GSM modem. In this the man power is reduces from the finding the fault where it is.The
ultimate objective is to monitor the distribution line status continuously and hence to guard the fault
of distribution line due to the constraints such as overvoltage, under voltage, SLG, DLG faults. If
any of these does occurs then a message will be sent to the designed controlling unit or substation.
4.1 BLOCK DIAGRAM
V. WORKING
The working of distribution line fault detector and intimate using GSM is based on the
microcontroller. In this the distribution line consist of 220v, 50 Hz supply, as that we can’t use the
220 v supply directly to the working kit. So instead of that we are using the step down transformer
for step down the input voltage into 12 v ac supply which makes as the supply voltage to the kit.
The 12 v step down voltage from the transformer is given to rectifier which converts the ac supply
into dc supply for the purpose of only the dc source or supply is used as the source for the
microcontroller. After converting as dc supply, the boost circuit which we are using is used to boost
up the voltage if necessary (or) regulates the same voltage level. To run a microcontroller it is in
need of driver circuit and control unit.
Driver circuit
Driver circuit provides pulse to the microcontroller by using TLP250 IC. In this we are using seven
switch and they get supply from center tapped transformer. The tlp250 IC which get input current
gets 5mA, but the output supply current is increased into 11mA and the output voltage is 10-35V.
So, we are using in this micro controller.
Microcontroller has been programmed to sense the fault and send the fault location to the particular
person by uses of GSM. This GSM sends the message about a particular location of a fault that
occurs in a distribution line.
The result from the hardware is sending messages to the mobile phone is shown in the figure.
VI. CONCLUSION
Detecting the area where the fault is occurred is difficult. Using microcontroller and GSM
bases method is reliable to detect and intimate the fault. In the short time we can able know the
fault and rectify immediately. The man work is reduced and don’t need to walk along through the
power line to know the location of the fault. The GSM can sends messages instantly to the power
station and the required person want to send. The message costs are done by the mutual agreement
with the telecommunication companies in India (i.e., Bsnl, airtel, Vodafone, etc.). The
microcontroller is cheaper in cost and working efficiency is high and also it stands upto 1000 Celsius.
The proposed method is efficient method to detecting and intimating the faults through the
distribution line.
REFERRENCES
1. Anamika Yadav, Aleena Sweta Padma, „A novel transmission line relaying scheme for fault detection and
classification using wavelet transform and linear discriminant analysis‟ Ain Sham Engineering journel(2015)6,
pp.199-209.
2. D. A. Tziouvaras, ‘Protection of high-voltage AC cables’, in Proc. Power Systems Conference: Advanced Metering,
Protection, Control, Communication and Distributed Resources, pp 316-328, Mar. 14-17, 2006.
3. Denio T.Silva,Jose l.Silvino,Jose O.Paulino and Julio C.D. DE MELO, ‘Fault location on overhead power
transmission line by measuring current from shield wires’.
4. E. C. Senger, G. Jr. Manassero, C. Goldemberg, and E. L. Pellini, ‘Automated fault location system for primary
distribution networks’, IEEE Trans. Power Delivery, vol. 20, no. 2, pp. 1332-1340, April 2005.
5. He YiLi Chang-bin Wu Ai –guomeng Quing-yu „Research Of Phase To Phase Ground Fault Location In The
Distribution Line Phase On Wireless Sensor Networks‟.
6. 6. J. Zipp, „Protective relaying considerations for transmission lines with high voltage AC cables,‟ IEEE Trans.
on Power Delivery, vol. 12, no. 1, pp. 83 -96, Jan. 1997