ABSTRACT
1. INTRODUCTION
1
Lecturer Assistant of Mechanical Power Engineering, Faculty of Engineering, Fayoum University, e-mail:
[email protected]
2
Assistant Professor of Mechanical Power Engineering, Faculty of Engineering, Cairo University.
3
Assistant Professor of Mechanical Power Engineering, Faculty of Engineering, Fayoum University.
4
Associate Professor of Mechanical Power Engineering, Faculty of Engineering, Cairo University.
5
Professor of Mechanical Power Engineering, Faculty of Engineering, Cairo University.
A.KAOOD ET AL
energy saving. This can be achieved by using various heat transfer enhancement
techniques [1]. During the last decades, vast number of studies have been carried out
to enhance the heat transfer characteristics in many engineering applications to provide
more reliable and efficient thermal systems in terms of reducing the size, weight and
cost, consequently increasing energy saving [2]. There are three techniques that can be
used for enhancing heat transfer rate, which are active, passive and combination
techniques. For active technique, an external power is required to achieve the
enhancement process, such as rotating or wiping the heat transfer surface, surface
vibration and fluid vibration, injection or suction of the working fluids and using
electrostatic fields. The cost of additional power, complexity and difficulty in
manufacturing make this technique limited for special applications. While for passive
technique, no external power is needed such as surface roughness, helical coil inserts
and twisted tape inserts [3-5]. Corrugated tube is one of the passive techniques that is
commonly used in various applications such as solar heaters, condensers, evaporators,
gas turbine blade, steam condensers, nuclear reactors, heat exchangers, etc. [5].
During the last decades, several studies on the convective turbulent heat transfer
in rough tubes have been conducted and published. One of the popular and firstly
appeared investigation was presented for a turbulent flow in roughened tubes [6]. The
obtained results are for the heat transfer coefficients and the friction factors of
turbulent flow of water under constant heat flux boundary condition through
electrically heated tube. It was found that an augmentation of heat transfer coefficients
up to 270% can be achieved due to the roughness, but with larger increase in the
friction coefficients. Thermo-hydraulic characteristics of turbulent flow in tubes with
inward rectangular repeated rib roughness were studied [7].
Numerical and experimental investigations of turbulent flow through inclined
transverse rectangular ribs were conducted [8]. The obtained results have revealed that
the highest Nu number took place at the bottom regions of the ribs with angle 60°. The
heat transfer enhancement due to curved transverse roughness in circular tubes was
experimentally investigated for air as working fluid [9]. It was found that the influence
of Re on the friction factor (ƒ) is weak for rib-roughened tubes. On the other hand, it
2
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
has been indicated that for a specific rib pitch, the heat transfer augmentation increased
with the increase of the rib height, but the efficiency index enhanced by decreasing the
rib height.
Turbulent air flow characteristics in internally grooved tubes were
experimentally investigated [10]. The obtained results show that for grooved tubes,
maximum heat transfer augmentations achieved were up to 47% for rectangular
grooves, 58% for trapezoidal and 63% for circular grooves compared with the smooth
tube. Turbulent water flow was investigated numerically and experimentally in pipes
with periodic rectangular corrugations [11]. The results indicate that the friction factor
(ƒ) increases as the groove length increases and is unaffected by the groove height.
Results of experimental study of turbulent water flow through tubes with variant
roughness height were reported [12]. These results reveal that performance evaluation
criterion for rough tube increased first till reached a maximum value then it decreased
with increasing Reynolds number. For a specific roughness height, Nu ratio does not
always increase with increasing Reynolds number.
The use of helically roughness in tubes has been found to be a promising
method to increase the heat transfer rates in forced convection as indicated by several
investigators. Pressure loss and heat transfer characteristics through helically ribbed
tube were experimentally investigated [13]. It is indicated that a remarkable effect on
the pressure loss and heat transfer augmentation was found because of the use of
helically roughened ribs. The Nu enhancement was higher for larger depth and smaller
pitch of the helical rib. A single-phase pressure loss and heat transfer in a helical
micro-fin tube using water and oil as the working fluids with Prandtl number ranged
from 3.2 to 220, and Reynolds number from 2500 to 90,000 was experimentally
studied [14]. It was found that for Reynolds numbers larger than 30,000 the friction
factor (ƒ) is about 40 to 50% higher than that for a plain tube.
The effects of rib-height to diameter ratio and rib-pitch to diameter ratio in
helically roughened tubes on augmentation of heat transfer were illustrated
experimentally [15]. The obtained results reveal that the effect of rib pitch ratio was
dominant only for the friction factor (ƒ) while the rib-height ratio was the main factor
3
A.KAOOD ET AL
that controls the thermal performance characteristics. Numerical study of steady heat
transfer augmentation of laminar and transitional flow regions in coiled-tube heat
exchangers with helically ribs was reported [16]. It was found that a 80–100% increase
of heat transfer rate occurred due to the developed swirling flow while the relative
pressure drop is 10–600% larger compared to the traditional helically coiled heat
exchangers. The passive technique of heat transfer augmentation methods was
investigated numerically to estimate the distribution of temperature and pressure in a
smooth tube, corrugated and helically-finned tubes [17]. The results reveal that the
highest convective heat transfer coefficient and friction factor were obtained with
helically finned tube compared with corrugated and smooth tubes.
The employment of surface roughness in the form of periodic ribs was found to
be an efficient passive technique to improve the heat transfer in convective turbulent
flow, as pointed out by several researchers [2,18]. The enhancement, because of
improving the local turbulence caused by ribs, is significantly higher than obtained by
smooth channel [19]. They numerically investigated the turbulent forced convection in
a 2-dimensional channel with periodic transverse grooves on the channel wall. They
indicate that the Nu increased and ƒ decreased with increasing of Reynolds number.
The friction factor for air flow in the grooved channel with larger width ratio was
found to be higher than that with smaller width ratio. A numerical study was reported
on the thermo-hydraulic performance of turbulent flow through an axisymmetric 2D
tube with non-uniform half-circle corrugation for Reynolds number ranging from 6000
to 57000 [20]. It was found that the friction factor and effectiveness factor decrease
with increasing of Re. They also indicated that, the performance of ribbed tube with a
pitch of 12.5 mm is more effective than that with a 10 mm rib-pitch for the same
geometrical parameters.
Recently, the thermal and hydraulic characteristics through a rib-grooved
channel were investigated numerically for turbulent flow of different types of
nanofluids including Al2O3, CuO, ZnO and SiO2 [21]. The results indicate that SiO2-
water nanofluid gives the highest Nu, and that increasing the nanoparticles volume
fraction enhanced the Nu within the range of Re from 30,000 to 50,000. A numerical
4
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
study of turbulent nanofluid flows Al2O3, CuO, ZnO and SiO2 through channels with
transversely inward ribs of different shapes was reported for Re ranged from 5000 to
20000 and heat flux boundary condition of 10 kW/m2 [2]. The results revealed that the
highest PEC was obtained for the in-lined triangular roughness with width to height
ratio w/e = 4 at Re = 5000.
Obviously, the advantages of using the corrugated tube as a passive technique
for heat transfer enhancement motivate us to investigate the pressure drop and heat
transfer characteristics of turbulent flow in such channels. Most previous studies
tackled flow in channel of different geometries and limited corrugation shapes with
several studies used nanofluids as working fluid. From the above literature review, it
can be stated that the case of fully turbulent water flow in inward/outward transversely
distributed triangular, rectangular, curved and trapezoidal corrugated tubes seems to
the author's knowledge have not been thoroughly investigated. The present study
numerically investigates the 2D axisymmetric turbulent forced convective flow in
transversely corrugated tubes having different corrugation shapes (triangular,
rectangular, curved and trapezoidal) distributed inward/outward. Different corrugation
pitch-to-diameter ratio (p/d); corrugation height-to-diameter ratio (e/d); and
corrugation width-to-diameter ratio (w/d) are considered for flow with Reynolds
numbers in the range from 5000 to 61,000. Factors of interest are the heat transfer in
terms of Nusselt number (Nu), pressure loss in terms of friction factor (ƒ) and thermal
performance evaluation criterion (PEC) for turbulent forced convective in tubes with
inward/outward transversely corrugations of different shapes as mentioned above.
These characteristics are presented and discussed to reveal the effects of the different
geometrical shapes on the thermal and flow fields in the prescribed tubes.
2. MODEL DESCRIPTION
5
A.KAOOD ET AL
The configuration of various ribs and corrugation directions are shown in Fig.1 while
the geometrical parameters of these corrugations and the tubes are shown in Fig. 2
along with the physical model and computational domain considered in the present
study. The geometrical parameters and dimensions of the tube and the studied
corrugations are: d = 10 mm, l = 100 mm, e/d = 0.025, w/d = 0.2 and p/d = 0.5.
For similar studies, the instability of the 3-dimensional vortex can be neglected
[20]. Thus, the 3D problem can be simplified to the 2D axisymmetric to decrease the
cost and time of computation in both the smooth and corrugated tubes [4,20]. The
axisymmetric physical model of the studied tube, test section and the computational
domain are shown in Fig. 2(b). The investigation has been carried out for fully
developed turbulent flow conditions with seven different Reynolds numbers within the
range from 5000 to 61000. Water is used as the working fluid.
6
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
(a) (b)
3. MATHEMATICAL MODELLING
3.1 Governing equations and mathematical methods
(1)
7
A.KAOOD ET AL
Momentum equation:
(2)
Energy equation:
(3)
(4)
The turbulence kinetic energy (k) and rate of energy dissipation (ε) equations as given
in [4,23-25]:
(5)
(6)
(7)
(8)
, , , .
All the governing equations were solved using the FLUENT software, which is
based on the finite volume method [25]. The SIMPLE (Simi-Implicit Pressure Linked
Equation) algorithm was used for the velocity pressure coupling, while a second-order
upwind scheme and a central difference scheme were used for discretizing convective
and diffusive terms, respectively. The minimum convergence criterion was set to be
1×10-7 for the continuity equation, velocity and turbulence quantities and 10-8 for the
energy equation. The following assumptions are adopted for the numerical
computation carried out in the present study: (i) Corrugations are periodically
8
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
distributed along the axial direction of the tube; (ii) The flow is steady, turbulent, fully
developed, 2-dimensional axisymmetric; (iii) Variation of properties of water are
negligible. Moreover, the heat loss to the environment is neglected.
Fig. 3. Grid system for (a) Curved outward ribs (b) Triangular outward ribs
(c) Curved inward ribs (c) Triangular inward ribs.
For the grid independence test, seven different mesh densities into the present tubes
are tested over the average Nusselt number and friction factor values for the studied Re
range. For example, the mesh independence test for inward triangular corrugation at
Re = 30,000 is shown in Fig. 4. The seven meshes have grid layout with
approximately 37,700 cells, 75,400 cells, 113,100 cells, 188,500 cells, 377,000 cells,
565,500 cells and 754,000 cells, respectively.
9
A.KAOOD ET AL
It has been found that after 188,500 cells, a further increase in cells results in a small
variation in the computed average values of both Nu and ƒ as indicated in Fig. 4. This
indication has been taken as a criterion for grid independence. The fifth grid
configuration (377,000 cells) confirms the grid-independence therefore, it has been
adopted throughout the current study for the inward triangular ribs to get an acceptable
compromise between the results accuracy and computational time besides, satisfying
the near wall criteria y+≤1 which compatible with enhanced wall treatment. Results of
the mesh independence studies for the rest of various corrugation shapes are
summarized in Table 1.
Table 1. Grids number for studied corrugation shapes
Corrugation Direction Corrugation Shape Cells Number
Rectangular 573,000
Trapezoidal 434,100
Inward
Curved 353,500
Triangular 377,000
Rectangular 454,000
Trapezoidal 509,100
Outward
Curved 530,400
Triangular 696,000
10
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
(12)
(13)
where (Num, ƒm) and (Nus, ƒs) are the Nusselt number and the friction factor for
modified tube (corrugated) and smooth tube, respectively. More details concerning
PEC were presented in [4,26].
11
A.KAOOD ET AL
(14)
, (15)
12
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
(a) (b)
Fig. 5. Present model validation for smooth tube (a) Nusselt number. (b) Friction
factor.
Another validation was carried out for fully developed turbulent flow through a
corrugated tube with inward rectangle ribs [4]. The results are found to be in a good
agreement for both Nu and ƒ as shown in Fig. 6(a,b).
(a) (b)
Fig. 6. Validation for inward rectangle ribbed tube (a) Nusselt number. (b) Friction
factor.
Therefore, the numerical algorithm adopted in the present study for heat transfer and
pressure drop predictions is considered to be reliable and can be applied for other cases
and different corrugation shapes as presented and discussed below.
13
A.KAOOD ET AL
4.2. Results of computed heat transfer and friction factor for inward corrugations
4.2.1 Heat Transfer
Results of computed heat transfer rate in terms of the Nusselt number inside circular
tubes with inward transverse corrugations of various shapes are presented and discussed in
this section. The obtained results for the variation of average Nu with Reynolds number in
the range from 5000 to 61000 for inward different corrugation shapes compared with that
for a smooth tube are presented in Fig. 7(a). The figure indicates that as Re increases, the
Nu for the various corrugation shapes also increases. The highest Nu values shown in the
figure are for the rectangular and trapezoidal corrugation shapes due to the presence of
high recirculation and thin boundary layer, consequently better mixing and better heat
transfer enhancement. The average Nu (computed over the considered range of Re) for
trapezoidal, rectangular, curved and triangular corrugation shapes are 52.61%, 50.12%,
47.82% and 44.96%, respectively, higher than that estimated for a smooth tube over the
same range of Re. The results also reveal that all inward corrugation shapes gave higher
values of the Nu than that belong to smooth tube as shown in Fig. 7(a), due to high
turbulence and mixing that occur due to such corrugations in the near wall, thus which
destroy the thermal boundary layer and enhance heat transfer. In addition, the modified to
smooth tube Nu ratio (Num/Nus) increases at low values of the studied range of Re until
reaching a maximum value then decreases with the increase of Re over the rest of Re
range as Fig. 7(b) indicates.
(a) (b)
Fig. 7. Nusselt number (Nu) versus Re for various inward ribs (a) Nu. (b) Nu ratio.
14
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
(a) (b)
Fig. 8. Friction factor versus Re for various inward ribs (a) ƒ. (b) ƒ ratio.
15
A.KAOOD ET AL
4.3 Results of computed heat transfer and friction factor for outward corrugations
4.3.1 Heat Transfer
Results of computed heat transfer rate in terms of Nusselt number with Reynolds
number range from 5000 to 61000 for outward rectangle, triangle, curve and trapezoid
corrugation shapes are depicted in Fig. 9. The results show that as Reynolds number
increases, the Nu values for the various outward corrugation shapes also increase. It is
shown also that all outward corrugation shapes gave higher values of the Nu than that
for a smooth tube, which can be attributed to the better flow mixing caused by the
radial swirl flows. Figure 9 indicates that the trapezoidal and curved corrugation
shapes give the highest Nu compared with that for other shapes over the whole range
of Re considered in the study. On the other hand, the computed average Nu over the
whole range of Re for trapezoidal, curved, triangular and rectangular corrugation
shapes are 48.31%, 45.72%, 41.23% and 40.94%, respectively, higher than that for the
smooth tube. In addition, the ratio of Num for corrugated tubes to that for a smooth
tube Nus ratio (Num/Nus) increases at low values of the studied range of Re until
reaching a maximum value at Re ≈10,000 then decreases with the increase of Re over
the rest of the studied range of Re for the various corrugation shapes.
(a) (b)
Fig. 9. Nusselt number (Nu) versus Re for various outward ribs (a) Nu. (b) Nu ratio.
16
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
(a) (b)
Fig. 10. Friction factor versus Re for various outward ribs (a) ƒ. (b) ƒ ratio.
17
A.KAOOD ET AL
study is shown in Fig. 11. It is noted from this figure that for both inward, Fig. 11(a)
and outward, Fig. 11(b), corrugations the PEC increases at low values of the studied
Re until reaching maximum values at Re around 10,000, then start to decrease
gradually. The results show also that both inward/outward curved and triangular
corrugation shapes have in general the superior PEC compared with those for
rectangular and trapezoidal corrugations for the whole studied range of Re. Figure
11(a) also shows that the PEC values are less than one for all inward corrugation
shapes for Re ≥ 40,000. Comparison of Figs. 11(a) and (b) indicates that the outward
corrugation shapes give higher PEC values than corresponding inward corrugation
shapes. It is known that thermal boundary layer becomes thicker as Re decreases.
Consequently, the effect of corrugations in promoting the boundary layer disruption at
lower Re is more significant than that at higher Re. It is noted that at lower Re values,
superior heat transfer enhancement has been achieved (higher Num/Nus and higher
PEC). Accordingly, it can be concluded that the use of corrugated tubes for heat
transfer enhancement is more promising in terms of energy saving at the low Re values
within the studied Re range. It is clear from Fig. 12 that almost all the studied
corrugation shapes have better average/maximum PEC values (PEC ≥ 1) over the
studied range of Re especially, the outward triangular, curved and trapezoidal shapes,
respectively.
(a) (b)
Fig. 11. PEC versus Re for various ribs (a) Inward. (b) Outward
18
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
.
Fig. 12. Average/Maximum PEC for various ribs.
5. CONCLUSION
19
A.KAOOD ET AL
for outward corrugations. For both cases (inward/outward), the friction factor
decreases with the increase of Re.
5. The average friction factors for (inward) rectangular, trapezoidal, curved and
triangular corrugation shapes are 265.72%, 238.72%, 168.97% and 167.01%,
respectively, higher than that for a smooth tube.
6. The mean friction factor for (outward) rectangular, trapezoidal, curved and
triangular corrugation shapes are 162.27%, 146.39%, 116.88% and 87.1%,
respectively, higher than that for a smooth tube.
7. For both inward/outward corrugations direction with various corrugation shapes, the
PEC increases until reaching maximum values at Re around 10,000, then starts to
decrease gradually.
8. Both inward/outward curved and triangular corrugations have superior PEC than
those for rectangular and trapezoidal corrugations.
9. Based on the present results and conclusions it can be stated that the use of
corrugated tubes for heat transfer enhancement in various applications is more
promising in terms of energy saving at the low Re values within the studied range.
20
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
REFERENCES
1. Thianpong, C., Eiamsa-ard, P., Wongcharee, K. and Eiamsa-ard, S., “Compound Heat
Transfer Enhancement of a Dimpled Tube With a Twisted Tape Swirl Generator”,
International Communications in Heat and Mass Transfer, Vol. 36, No. 7, pp. 698–704,
2009.
2. Vanaki, Sh. M., and Mohammed, H. A., “Numerical Study of Nanofluid Forced
Convection Flow in Channels Using Different Shaped Transverse Ribs”, International
Communications in Heat and Mass Transfer, Vol. 67, pp. 176–188, 2015.
3. Zimparov, V., “Enhancement of Heat Transfer by a Combination of a Single-start
Spirally Corrugated Tubes With a Twisted Tape”, Experimental Thermal and Fluid
Science, Vol. 25, No. 7, pp. 535–546, 2002.
4. Mohammed, H. A., Abbas, A. K., and Sheriff, J. M., “Influence of Geometrical
Parameters and Forced Convective Heat Transfer in Transversely Corrugated Circular
Tubes”, International Communications in Heat and Mass Transfer, Vol. 44, pp. 116–126,
2013.
5. Webb, R. L., and Kim, N. Y., “Enhanced Heat Transfer”, 2nd Edition, Taylor and Francis,
NY, 2005.
6. Dipprey, D. F., and Sabersky, R. H., “Heat and Momentum Transfer in Smooth and
21
A.KAOOD ET AL
Rough Tubes at Various Prandtl Numbers”, International Journal of Heat and Mass
Transfer, Vol. 6, No. 5, pp. 329–353, 1963.
7. Webb, R. L., Eckert, E. R. G., and Goldstein, R. J., “Heat Transfer and Friction in Tubes
With Repeated-rib Roughness”, International Journal of Heat and Mass Transfer, Vol. 14,
No. 4, pp. 601–617, 1971.
8. Kiml, R., Magda, A., Mochizuki, S., and Murata, A., “Rib-induced Secondary Flow
Effects on Local Circumferential Heat Transfer Distribution Inside a Circular Rib-
Roughened Tube”, International Journal of Heat and Mass Transfer, Vol. 47, No. 6–7, pp.
1403–1412, 2004.
9. San, J. Y., and Huang, W. C., “Heat Transfer Enhancement of Transverse Ribs in
Circular Tubes With Consideration of Entrance Effect”, International Journal of Heat and
Mass Transfer, Vol. 49, No. 17–18, pp. 2965–2971, 2006.
10. Bilen, K., Cetin, M., Gul, H., and Balta, T., “The Investigation of Groove Geometry
Effect on Heat Transfer For Internally Grooved Tubes”, Applied Thermal Engineering,
Vol. 29, No. 4, pp. 753–761, 2009.
11. Stel, H., Morales, R. E. M., Franco, A. T., Junqueira, S. L. M., Erthal, R. H., and
Gonçalves, M. A. L., “Numerical and Experimental Analysis of Turbulent Flow in
Corrugated Pipes”, Journal of Fluids Engineering, Vol. 132, No. 7, p. 71203, 2010.
12. Li, X. W., Meng, J. A., and Li, Z. X., “Roughness Enhanced Mechanism for Turbulent
Convective Heat Transfer”, International Journal of Heat and Mass Transfer, Vol. 54, No.
9–10, pp. 1775–1781, 2011.
13. Naphon, P., Nuchjapo, M., and Kurujareon, J., “Tube Side Heat Transfer Coefficient and
Friction Factor Characteristics of Horizontal Tubes With Helical Rib”, Energy
Conversion and Management, Vol. 47, No. 18–19, pp. 3031–3044, 2006.
14. Li, X. W., Meng, J. A., and Li, Z. X., “Experimental Study of Single-Phase Pressure
Drop and Heat Transfer in A Micro-fin Tube”, Experimental Thermal and Fluid Science,
Vol. 32, No. 2, pp. 641–648, 2007.
15. Pethkool, S., Eiamsa-ard, S., Kwankaomeng, S., and Promvonge, P., “Turbulent Heat
Transfer Enhancement in A Heat Exchanger Using Helically Corrugated Tube”,
International Communications in Heat and Mass Transfer, Vol. 38, No. 3, pp. 340–347,
Mar. 2011.
16. Zachár, A., “Analysis of Coiled-Tube Heat Exchangers To Improve Heat Transfer Rate
With Spirally Corrugated Wall”, International Journal of Heat and Mass Transfer, Vol.
53, No. 19–20, pp. 3928–3939, 2010.
17. Ağra, Ö., Demir, H., Atayılmaz, Ş. Ö., Kantaş, F., and Dalkılıç, A. S., “Numerical
Investigation of Heat Transfer and Pressure Drop in Enhanced Tubes”, International
Communications in Heat and Mass Transfer, Vol. 38, No. 10, pp. 1384–1391, 2011.
18. Manca, O., Nardini, S., and Ricci, D., “Numerical Analysis of Water Forced Convection
in Channels With Differently Shaped Transverse Ribs”, Journal of Applied Mathematics,
Vol. 2011, 2011.
19. Eiamsa-ard, S., and Promvonge, P., “Numerical Study on Heat Transfer of Turbulent
Channel Flow Over Periodic Grooves”, International Communications in Heat and Mass
Transfer, Vol. 35, No. 7, pp. 844–852, 2008.
20. Zhang, D., Tao, H., Xu, Y., and Sun, Z., “Numerical Investigation on Flow and Heat
Transfer Characteristics of Corrugated Tubes With Non-uniform Corrugation in
Turbulent Flow”, Chinese Journal of Chemical Engineering, 2017.
21. Vatani, A., and Mohammed, H. A., “Turbulent Nanofluid Flow Over Periodic Rib-
Grooved Channels”, Engineering Applications of Computational Fluid Mechanics, Vol.
22
INVESTIGATION OF THERMAL-HYDRAULIC PERFORMANCE….
دراسة عددية النتقال الحرارة واالحتكاك لسريان مضطرب داخل انابيب مموجة األسطح
يتناول البحث دراسة عددية للخصائص الح اررية والهيدروليكية لسريان مائى داخل انابيب ذات أسطح
وتم دراسة.) خارجية/ منحنى) وباتجاهات مختلفة (داخلية، مثلث، شبه منحرف،مموجة بأشكال (مستطيل
بعض العوامل المتوقع ان تؤدى لتحسين انظمة انتقال الح اررة والتى لها استخدامات عديدة فى معظم
التطبيقات مثل محطات توليد الطاقة والطاقة الشمسية والتكييف والتبريد والمكثفات والمبخرات وعديد من
وتمت دراسة تغيير الشكل التقليدى لالنابيب المستخدمة فى.االستخدامات فى مجال الصناعة الغذائية وغيرها
انظمة انتقال الح اررة فتم استخدام االنابيب ذات أسطح مموجة وتم دراسة تأثيرها على انتقال الح اررة المتمثل
فى (رقم ناسلت) وتأثيرها على الفقد فى الضغط المتمثل فى (معامل االحتكاك) على مدى من رقم رينولد
وتم استخدام معامل لقياس كفاءة وجدوى الزيادة فى انتقال الح اررة مقارنة بالفقد فى.61000 الى5000
وقد وجد ان استخدام االنابيب ذات األسطح المموجة تزيد.الضغط ومقارنتها باالنابيب ذات األسطح المستوية
. لالنابيب المموجة فى اإلتجاه الداخلى%52.61 الى%44.96 معدل انتقال الح اررة بنسبة تتراوح من
ووجد ان معامل االداء. لالنابيب المتدرجة فى االتجاه الخارجى%48.31 الى%40.94 وبنسبة تتراوح من
. لمعظم االشكال واالتجاهات خاصة تلك ذات األسطح المموجة فى اإلتجاه الخارجي1 أكبر من
23