GDS3710 Connection & Wiring Diagrams ---- “Fail Safe” Electric Strike, 3rd Party Power Supply

Outdoors Indoors
Power Supply for GDS
12V V+ Power Supply for GDS
GND V‐ DC 12V 1A minimum
GND
IN1+ Door Lock Switch
IN1‐

IN2‐ V‐
Power Supply for 
IN2+ V+
Electric Strike
DC 6‐24V 
COM2
NC2
NO2 NOTE:

COM
NO
NC

V+
Some Electric Strike with

V‐
Open/Close status detector,
connected to GDS3710's
Alarm Input will allow
GDS3710 to display the door
COM1 “Fail Safe” Model status and set Alarm Output
NO1 Electric  Strike

GDS3710
GDS3710 Connection & Wiring Diagrams ---- “Fail Secure” Electric Strike, 3rd Party Power Supply

Outdoors Indoors
12V 1A  at least for GDS3710  Power Supply for Both 
12V V+
GDS3710 and Electric Strike: 
GND V‐
DC 12V 2ANote minimum.
GND
IN1+ Door Lock Switch
IN1‐

IN2‐ NOTE:
IN2+ • The input voltage of Electric 
Strike must be DC 12V in this 
COM2
case.
NC2 • The total  current of power 
NO2 must  refer to the max. 
current of electric strike to 

V+
V‐
sum up. 
• e.g.: striker need 500mA, the 
total should be 1 + 0.5 =1.5A  
COM1 minimum for the 3rd party DC 
NO1 “Fail Secure” Model Power Supply. 
Electric  Strike
GDS3710
GDS3710 Connection & Wiring Diagrams ---- “Fail Safe” Electric Strike, POE Power Supply

Outdoors Indoors
POE
POE Switch
POE
Eth Cat 5e/6 Ethernet  Cable
Eth
Eth
Eth

IN1+ Door lock Switch
IN1‐

IN2‐ V‐ Power Supply for 
IN2+ V+ Electric Strike
DC 6‐24V 
COM2
NC2
NO2

COM
NO
NC

V+
V‐
COM1
NO1
“Fail Safe” Model
GDS3710 Electric  Strike
GDS3710 Connection & Wiring Diagrams ---- Inappropriate Electric Strike Connection

Outdoors Indoors
12V Power Supply for Both 
V+
GDS3710 and Electric Strike: 
GND V‐
DC 12V 2ANote minimum.

COM2
V‐ V+
The reverse emf protection 
NC2
NO2 diode must always be 
installed in reverse polarity 
across the door strike

COM1
NO1 Relay limit:125VAC/0.5A, 30VDC/2A
Lamp
110VAC or 
220VAC

GDS3710
GDS3710 Connection & Wiring Diagrams ---- Good Electric Strike &High Power Device Connection

Outdoors Indoors
12V Power Supply for Both 
V+
GDS3710 and Electric Strike: 
GND V‐
DC 12V 2ANote minimum.

COM2
NC2

V+
V‐
NO2

COM1 V+
Low voltage DC power
NO1 V+ V‐ V‐

Add rely for Isolation protention
High power 
COM NO
Device L
110VAC or 220V AC
N
GDS3710
GDS3710 Connection & Wiring Diagrams ---- Wiegand RFID Reader

Outdoors Indoors
12V Power Supply for Both 
V+
GDS3710 and Electric Strike: 
GND V‐
DC 12V 2ANote minimum.

V‐ Power Supply for 
V+ Wiegand Device

DC5V Power supply option 
5V DC+
GND DC‐/GND
WG_D0_IN WG‐D0‐OUT
WG_D1_IN WG‐D1‐OUT
LED LED
BEEP BEEP

GDS3710