TRAU commissioning Siemens

TRAU commissioning

Contents
1 Commissioning procedure 3
2 Visual check 6
3 Download TRAU software 9
4 Activate TRAU software 13
5 Integration of TRAU 17
5.1 Set TRAU attributes 18
5.2 Configure PCMS 20
5.3 Set LAPD TS / TEI 22
5.4 Create TRAC 24
6 Verify module state / alarms 25
7 Change to phase three 26
8 Restart verification 28
9 Exercise 31

MN1784EU10MN_0002
1
© 2002 Siemens AG
Siemens TRAU commissioning

2 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

1 Commissioning procedure

MN1784EU10MN_0002
3
© 2002 Siemens AG
Siemens TRAU commissioning

The Installation and Test Manual ITMN:TRAU contains a detailed description of the
steps required for commissioning TRAU.
The following figure shows the main steps:

4 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Visual Checks Set LAPD time slot / TEI

Download TRAU Software Create TRAC

Activate TRAU Software Verify Module State/Alarms

Set TRAU Attributes Change to Phase Three

Configure PCMS Restart Verification

Fig. 1 TRAU commissioning procedure

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MN1784EU10MN_0002
5
© 2002 Siemens AG
Siemens TRAU commissioning

2 Visual check
Check the
 modules and auxiliary equipment,
 modules and relevant codes, power supplies (if used),
 firmware EPROM position and
 jumper settings.

Fig. 2 High capacity TRAU

6 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Fuse and Alarm Panel 0


T T T M B B M T T T
R R R S S S S R R R
TRAU-0 A A A C C C C A A A
C C C I I I I C C C

0 1 2 0 0 1 1 3 4 5

Fuse and Alarm Panel 1

TRAU-1

Fuse and Alarm Panel 2

TRAU-2

Fuse and Alarm Panel 3

TRAU-3

Fig. 3 TRAU classic

MN1784EU10MN_0002
7
© 2002 Siemens AG
Siemens TRAU commissioning

8 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

3 Download TRAU software

MN1784EU10MN_0002
9
© 2002 Siemens AG
Siemens TRAU commissioning

With an empty BSCI Flash EPROM (i.e. the TRAU software has not yet been
downloaded) the TRAU is in the "TRAU_FW" phase.
After the (first) download of TRAU SW (BSCI SW only, other SW files are skipped),
the TRAU changes automatically into phase 1 and a new logon is required. In phase
1, the TRAU SW has to be downloaded again (for the second time now, no files
skipped).
While the first download (ca. 2 min) puts only the BSCI software into BSCI RAM, the
second download (ca. 5 min) moves the whole TRAU SW into BSCI Flash EPROM.

first download:
LMT Bxxxxx.ABS RAM of BSCI

Fig. 4 First download of TRAU software

second download: BSCI Flash EPROM


TRAU software
LMT

Bxxxxx.ABS
Ixxxxx.ABS
Rxxxxx.ABS
Sxxxxx.BIN

Fig. 5 Second download of TRAU software

10 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Fig. 6 TRAU SW download (1st download in TRAU_FW phase)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MN1784EU10MN_0002
11
© 2002 Siemens AG
Siemens TRAU commissioning

Fig. 7 TRAU SW (on LMT hard disk)

12 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

4 Activate TRAU software

MN1784EU10MN_0002
13
© 2002 Siemens AG
Siemens TRAU commissioning

Activating TRAU software means loading the software stored in the BSCI's FEPROM
into the TRAU processors' RAM.
The activation takes about 5 minutes.
The TRAU automatically switches from phase 1 to phase 2 and a new logon is
necessary.
To check if the software download has been successful, the following commands are
available (not in phase 1):
 GET BSMS
Beside the BSCI / MSCI running software, GET BSMS also gives a "directory list"
with all the software stored on BSCI (max 2 loads).
 GET TRAC
GET TRAC shows only the TRAC specific software files (including the binary file).
 GET TRAU
GET TRAU shows the software load header only (but no individual files).

Activate software

RAM of Processors
BSCI Flash EPROM

Fig. 8 Activate TRAU software

14 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Fig. 9 Activate TRAU software

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MN1784EU10MN_0002
15
© 2002 Siemens AG
Siemens TRAU commissioning

Fig. 10 Get BSMS

16 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

5 Integration of TRAU

MN1784EU10MN_0002
17
© 2002 Siemens AG
Siemens TRAU commissioning

5.1 Set TRAU attributes


The command SET TRAUE is used to define the
 type of PCM used (PCM24 / PCM30),
 Sales Unique Name SALUNAME,
 TRAU synchronization law
(selection "MSC" defines the special cases like cross-connect equipment between
MSC and TRAU)
 type of TRAUE
("with_TPWR": separate power supply modules, "classic" hardware;
"without_TPWR": power supply integrated on the modules, latest "classic"
hardware and HC TRAU Rack).

Notes
Together with the TEI, the SALUNAME uniquely identifies the TRAU. Their settings
have to be in accordance with the BSC database.
SALUNAME is set per rack (i.e. it is identical for all TRAU shelves in the same rack).

18 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Fig. 11 Set TRAU attributes

Fig. 12 Set TRAU attributes

MN1784EU10MN_0002
19
© 2002 Siemens AG
Siemens TRAU commissioning

5.2 Configure PCMS


The PCMS attributes are configured with the command SET PCMS:

Parameter Description
LOWBER Threshold for the bit error rate. Range: 10E-3, 10E-4, ..., 10E-9 and
NULL.
PCMPAR PCM Line Parameters, defining whether or not CRC is used, whether
HDB3 or AMI code is used, whether not urgent alarms are signaled
and which values for the bite error rate and the bit alignment frame
are used.
REMAL Remote alarm indication type for PCM24 lines (CCITT or Bellcore).
For PCM30: Null.

20 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Fig. 13 Set PCMS attributes

Fig. 14 Set PCMS attributes

MN1784EU10MN_0002
21
© 2002 Siemens AG
Siemens TRAU commissioning

5.3 Set LAPD TS / TEI


To configure the
 LAPD (LPDLS) time slot and
 Terminal Endpoint Identifier TEI,
the command SET LPDLS is used.

Parameter Description
TEI Terminal Endpoint Identifier, range: 0 - 63
(for ID used together with SALUNAME)
ASUBLAPDCH Time slot used for LPDLS link, range: 1 - 31

Wait until BSMS and TRAC boards are loaded before continuing with the next steps.

22 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Fig. 15 Set LPDLS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MN1784EU10MN_0002
23
© 2002 Siemens AG
Siemens TRAU commissioning

5.4 Create TRAC


Only TRAC-0, TRAC-1, BSMS-0, BSMS-1 (and TPWR-0 and TPWR-1, if used) are
created automatically.
The remaining TRAC boards (TRAC-2 … TRAC-5) have to be created manually.

Note: The attempt to create TRAC-0 / 1 is rejected because "Resource already


exists."

Fig. 16 Creation of TRAC modules

24 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

6 Verify module state / alarms


Check the state and status of all modules (BSMS, TRAC and TPWR, if used). The
desired state is:
 administrative state: unlocked and
 operational state: enabled.
Check the TRAU alarm panel.
Use the command GETAEC TRAUE to find active alarms on LMT.

MN1784EU10MN_0002
25
© 2002 Siemens AG
Siemens TRAU commissioning

7 Change to phase three


To switch TRAU from phase 2 to phase 3, use the Switch button in the LMT Control
Center (new logon required). Afterwards unlock the TRAU.
Wait until the BSMS is in hot standby.

Fig. 17 LMT control center

26 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Fig. 18 Message browser

Fig. 19 UNLOCKREQUEST TRAU

MN1784EU10MN_0002
27
© 2002 Siemens AG
Siemens TRAU commissioning

8 Restart verification
Power off and on the TRAU to check that the TRAU recovers without after a total loss
of power.

Note: For the TRAU without separate power supply modules, "Power Off" means
"extract BSCI" and "Power On" means "insert BSCI".
After the autonomous bring-up check if the TRAU is running with the desired software
load (using GET TRAU command).

28 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Lamp Panel
Fuse and Alarm
Panel 1

P T T
T M B B M T T T P
W R R
R S S S S R R R W
R A A
A C C C C R
S C C
C I I I A A A S
I C C
0 0 1 2 0 1 1 C 1
0 3 4
5
Fuse and Alarm
Panel 2

Fuse and Alarm


Panel 3

Fuse and Alarm


Panel 4

Fig. 20 TRAU restart verification

MN1784EU10MN_0002
29
© 2002 Siemens AG
Siemens TRAU commissioning

30 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

9 Exercise

MN1784EU10MN_0002
31
© 2002 Siemens AG
Siemens TRAU commissioning

32 MN1784EU10MN_0002
© 2002 Siemens AG
TRAU commissioning Siemens

Exercise
Title: Commission the TRAU in the Training Center.

Objectives: Understanding the Commissioning Procedure for TRAU

Task
In the Training Center you find an already running system: It is not possible to
format the Flash EPROM of BSCI-0 and BSCI-1 simultaneously, only the
standby side can be formatted. Therefore, the commissioning procedure described
above must be modified.
Information to be collected
 Software load header: Check the subdirectory containing the TRAU software on
your LMT hard disk.
Compare the TRAU software load header with the TRAU software load defined in
the BSC database (with the command CREATE TRAU).
 TEI and SALUNAME.
 Time slot used for LAPD signaling.
 CRC4 used or not.
 PCM line code used (AMI or HDB3).
 Setting for Not Urgent Alarm (enabled or disabled).
 Threshold for Bit Error Rate BER.
 Setting for Bit Alignment Frame BAF.
Since the TRAU in the Training Center is already running, the desired information
may also be obtained directly via LMT (e.g. using GET... commands).
Additional steps for bringing the system down:
I) Find out BSMS "standby side": GET BSMS (attribute STNDBYST)
II) Lock TRAU and Switch to phase 2 (button in LMT Control Center, new
logon is required)
III) Lock BSMS "standby side"
IV) Format "standby" BSMS Flash EPROM
This procedure requires about 40 seconds.
Power off
a) TRAU with power supply modules: Switch off both power supplies
immediately after the "Format successful" message (Note: This message
is only displayed in the LMT Message Browser).
b) TRAU without power supply modules: Pull out all BSCI/MSCI boards
immediately after the "Format successful" message (Note: This message
is only displayed in the LMT Message Browser).

MN1784EU10MN_0002
33
© 2002 Siemens AG
Siemens TRAU commissioning

Perform the software download with only the former "standby" part of the TRAU
(BSCI, strictly speaking) powered on.
Only after the TRAU software activation (phase 2), power on the former "active" half
of TRAU. Wait until the (former active, now standby) copy of BSMS is fully loaded
(message "MSCI loaded“ appears after ca. 5 minutes).
Now proceed with the TRAU configuration.