DSO150 UserManual Shell New
DSO150 UserManual Shell New
User Manual
Applicable models: 15001K, 15002K
Rev. 07
tools needed
M
1 Check kit contents and part quantities/values by the photo at right and part list in page2
and page 3. Report missing or wrong parts to your vendor.
O
2 Resistor values are easy to mis-read. It is strongly suggested to check their values
by ohm-meter before soldering them to board.
3 Make sure you understand the polarities and orientations of all parts.
.C
Important !!!
TE h
If your have purchased 15002K kit (SMD not pre-soldered) you must install all
H
E ec
SMD parts before mounting the through-hole parts. Please refer to the instructions
below for SMD part installation. Otherwise, proceed to page2 to start through-hole
part assembly.
C
Y T
SMD parts are only installed to the analog board (PCB PN# 109-15001-xxx).
.J YE
1. Before soldering check components against the
part list to make sure you have correct parts.
Solder ICs
2. Identify IC orientation and diode polarity (see photos). Pin1
3. Do not put iron on one pad for too long time. Otherwise,
W J
traces may peel off and get damaged.
U5 1 ICL7660, SO8
U6 1 79L05, SOT89 PIN 1
R19, R20 2 1K,1%, 0805 Note:
Place IC in front of Photos here are for
R17, R18 2 10K,1%, 0805
W
M
Step 1 Assembly the Main Board (follow the order as numbered) Step 2 Assembly the Analog Board (follow the order as numbered)
1. Check the main board 4. Slide Switch 1. Resistors 4. Electrolytic capacitors
O
1 Before mounting any parts to the main board Note:
connect a 9V power supply (center positive) to J7
Always meter resistor
on the board to check the display.
.C
values before soldering.
2 You should see the scope boots up to a screen SW5 : DPDT
Resistors are all 1/8W.
similar to the photo below. D1 (LED) blinks twice.
TE h
Do not solder any parts to the board if you find R7 : 300Ω
problem. Otherwise warranty will be voided. R8, R16 : 150Ω
H
Report the problem to vender or JYE Tech.
Solder positive pole
E ec
R1 : 510KΩ C8, C10, : 100μF / 1 6 V
5. Pin-header (male) R2 : 5.1MΩ
R9 : 91Ω
(the longer lead) to C11
2 R10 : 30Ω the square pad
Check R3 : 1. 2M Ω
C
R11, R12 : 15Ω
display J2 : 1X4 pin, 0.1" pitch
R4 : 11KΩ
Y T
R13 : 3KΩ
R5, R6, R14 : 1KΩ R15 : 130Ω
5. BNC connector
1 J1 : BNC
.J YE
Apply power
2. Ceramic Capacitors Note:
The thicker pins need
(DC jack is 5.5mm dia.
with 2.1mm core)
6. Tact Switches to heat up longer to get
C1 : 0.1μ F good soldering result.
SW1, SW2, : 12x12x7mm C2 : 330pF
SW3, SW4
W J C4 : 1pF
SW1 : 2P3T
J8 : 4.8 x 0.8mm terminal
Note: Before soldering bend the terminal to the
shape as shown in the left photo above. Finished
W
3. Power Connector (optional) Let iron stay on one pad of the resistor until solder on
the other pad melt and then remove the part.
Note:
R30 is used to bypass SW5 so as the mainboard can be
W
Page 2
JYE Tech Ltd. - www.jyetech.com -
Important !
Tips:
Step 3 Assembly Front Module Step 4 Check Voltages Alw ays remove power before
connecting or disconnecting Step 5 Calibration Pe rform VPos alignment
before calibrating C3 and C5.
the analog board.
1. Solder Rotary Encoder Verify voltages on the analog board Adjust trimmers C3 and C5
Mount to the small PCB 1 Attach the analog board to the main board Mea surem ents applicable
1 Connect the red clip to the test signal terminal and leave the
(PN: 109-15002-00A) for “E” version PCB black clip un-connected (see photo at bottom).
by mating J2 on the analog board to J4 on (PN:109-15001-00E)
Note: the main board (see photo). 2 Apply power and boot. Hold down ADJ dial for 3 seconds to
Please pay attention to the
bring up Test Signal amplitude display at lower-left corner.
orientation of PCB. Use the
2 Apply 9V DC power supply to J7 (or J6) on Push ADJ to set the amplitude to 0.1V.
side with outline marking. the main board. V2 3 Set sensitivity to 50mV and adjust trigger level so that
M
3 Set couple switch to GND position. V1 Couple
waveform stable (see “How to Use” at page 4). A. Not enough
V3 switch
4 Check voltages at the points 4 Tuning C3 so that sharp rectangle (photo B at left) is obtained.
2. Assemble Front Module as shown in the photo. AV- AV+ The adjustment for C3 is done.
5 Similarly, for C5 calibration push ADJ to set test signal to
O
1 Fit LCD to front panel as shown below. References 3.3V. Change sensitivity to 1V. Tuning C5 so that sharp
(*) Input dependent rectangle waveform is obtained. The adjustment is done.
Input +9.30V
Place negative
pen at DGND
.C
V+ (*) +8.35V
C3 C5 B. Good
AV+ 5.0V+/-2% V+
V- (*) -7.86V V4
TE h
AV- -5.0V+/-2% V-
V1 0V
H
V2 0V
E ec
V3 0V Analog board
V4 ~1.65V Apply power part number
here (DC jack is 5.5mm dia.
with 2.1mm core) C. Too much
C
Y T
2 Fold the main board over while keeping
LCD in place. Step 6 Put all parts together It is strongly recommended to read the article “FAQ, Tips, and Troubleshooting”
at www.jyetech.com/forum under the sub-forum “DSO Shell”.
.J YE
Final assembly
1 Screw the analog board to 2 Combine the front module and 3 Make sure receptacle (J4) 4 Attach bottom bracket before
back cover with the top the back cover mate with pin-header (J2) holding the two modules
bracket attached together
W J
Screws Top bracket Bottom bracket
KA2x4
(4 positions)
Important !
B. Make sure PCB evenly Screws PA2.3x8
touch the front plate (4 positions)
while doing C.
M
Switch Level
Timebase
Indicator
(s/div) Default Restore Hold down [SEC/DIV] and [TRIGGER] buttons simultaneously for about 3 seconds.
Test Signal
Couple Trigger
output BNC Mode Center HPos Hold down [SEC/DIV] button for about 3 seconds. This will make the data at the center
Connector of capture buffer displayed.
O
(Signal Input) Trigger
Sensitivity Slope Center Trigger Hold down [TRIGGER] button for about 3 seconds. This will set the trigger level t0 the
(V/div) Level medium value of signal amplitude.
HOLD / RUN Fast Adjustment Short press of [ADJ] toggles Fast Adjustment mode on and off for VPos, HPos, and
.C
Sensitivity Button Trigger Level. A “>>” sign appearing at top of screen indicates Fast Adjustment is ON.
Button
TE h
Trigger
About Trigger State
Sen
Bu tton
sitivity
Button
The trigger can have three states including Holdoff, Waiting, and Trigged. They are explained below.
H
Timebase
Holdoff: Trigger is disabled until a portion of sample buffer prior to a trigger point is filled with raw data.
E ec
Button
Waiting: Trigger is waiting for a valid signal slope.
Connectors Trigged: A valid signal slope has been detected and registered.
for Power Supply
Rolling Mode
C
(5.5 x 2.1mm) Power
Switch When timebase is set to 50ms or slower and trigger mode is set to AUTO the scope will automatically switch to
Y T
Adjustment Rolling Mode where waveform shifts from right to left constantly. The trigger is disabled under this mode.
Dial
Troubleshooting
Connections
.J YE
Atte ntion
Power Supply: Connect 9V DC power supply to the 5.5x2.1mm 1. Power supply voltage must not exceed Problems Possible Causes
jack at bottom (center positive). Power supply 10V. Otherwise it may damage the ICs Bad V+ 1 Connector J7 defective. 2 Diode D2 open or damaged.
voltage must be in the range of 8 - 10V. inside.
Probe: Connect probe to the BNC connector at top. 2. Allowed maximum signal input voltage Bad V- 1 Bad C12 and/or C13. 2 U5 (7660) bad soldering or defective.
is 50Vpk (100Vpp) with the clip probe. Hint: Check with R27 disconnected would let you know the issue is caused by load or source.
W J
Operations Bad AV- 1 R27 bad soldering or wrong value. 2 Shorts between AV- and ground.
Basic Button Functions Bad AV+ 1 R26 bad soldering or wrong value. 2 Shorts between AV+ and ground.
[V/DIV]: Select sensitivity or vertical position. The selected parameter indicator will be highlighted. V1 does not close 1 SW1 not set to GND position. 2 Bad soldering on R1 and/or R2.
[SEC/DIV]: Select timebase or horizontal position. The selected parameter indicator will be highlighted. to 0V
3 Bad soldering on U1.
[TRIGGER]: Select trigger mode, trigger level, and trigger edge. The selected parameter indicator will be highlighted.
V2 does not close 1 SW1 not set to GND position. 2 Bad soldering on R3 and/or R4.
[OK]: Enter HOLD state (freeze waveform). Press it again will de-freeze.
to 0V
[ADJ]: Adjust the parameter seleted (highlighted). Short press toggles Fast Adjustment mode. 3 Bad soldering on U1.
Couple switch: Set couple to DC, AC, or GND. When GND is selected the scope input is isolated from input V3 does not close 1 Bad soldering on U1 and/or U2. 2 Bad soldering on R5 and/or R6.
signal and connected to ground (0V input). to 0V
Bad V4 1
W
Specifications No Trace 1 Incorrect V4. If V4 is correct perform factory default restore as described in 2
Max realtime sample rate 1MSa/s Timebase range 500s/Div -- 10us/Div 2 Make sure trigger mode is AUTO and timebase is 1ms. Hold down [SEC/DIV] and [TRIGGER]
Analog bandwidth 0 -- 200KHz Trigger modes Auto, Normal, and Single buttons simultaneously for 3 seconds.
W