Rneasy Plus Micro Kit: Quick-Start Protocol March 2016
Rneasy Plus Micro Kit: Quick-Start Protocol March 2016
Rneasy Plus Micro Kit: Quick-Start Protocol March 2016
Further information
RNeasy Plus Micro Handbook: www.qiagen.com/HB-1950
Safety Data Sheets: www.qiagen.com/safety
Technical assistance: support.qiagen.com
1. Cells: Harvest a maximum of 5 x 105 cells, as a cell pellet, or by direct lysis in the cell-
culture dish (up to 10 cm diameter). Add 350 µl Buffer RLT Plus. Homogenize the lysate.
Tissues: Do not use more than 5 mg tissue. Add 350 µl of Buffer RLT Plus. Disrupt and
homogenize the tissue using the TissueRuptor® or TissueLyser instruments. Centrifuge the
lysate for 3 min at maximum speed. Remove the supernatant by pipetting and use it in
step 2.
Sample to Insight__
Microdissected cryosections: Collect the sample directly into an appropriate volume of
Buffer RLT Plus. (The volume depends on the collection vessel used for microdissection,
but should not exceed 65 µl [Leica® instruments] or 300 µl [other instruments].) Adjust the
volume to 350 µl with Buffer RLT Plus. Vortex for 30 s.
2. Transfer the lysate to a gDNA Eliminator spin column placed in a 2 ml collection tube
(supplied). Centrifuge for 30 s at ≥8000 x g (≥10,000 rpm). Discard the column, and
save the flow-through.
3. Add 1 volume (usually 350 µl) of 70% ethanol to the flow-through, and mix well by
pipetting. Do not centrifuge. Proceed immediately to step 4.
4. Transfer the sample, including any precipitate that may have formed, to an RNeasy
MinElute spin column placed in a 2 ml collection tube (supplied). Close the lid, and
centrifuge for 15 s at ≥8000 x g. Discard the flow-through.
5. Add 700 µl Buffer RW1 to the RNeasy MinElute spin column. Close the lid, and
centrifuge for 15 s at ≥8000 x g. Discard the flow-through.
6. Add 500 µl Buffer RPE to the RNeasy MinElute spin column. Close the lid, and centrifuge
for 15 s at ≥8000 x g. Discard the flow-through.
7. Add 500 µl of 80% ethanol to the RNeasy MinElute spin column. Close the lid, and
centrifuge for 2 min at ≥8000 x g to wash the spin column membrane. Discard the
collection tube with the flow-through.
8. Place the RNeasy MinElute spin column in a new 2 ml collection tube (supplied). Open
the lid of the spin column, and centrifuge at full speed for 5 min to dry the membrane.
Discard the collection tube with the flow-through.
9. Place the RNeasy MinElute spin column in a new 1.5 ml collection tube (supplied). Add
14 µl RNase-free water directly to the center of the spin column membrane. Close the lid
gently, and centrifuge for 1 min at full speed to elute the RNA.
For up-to-date licensing information and product-specific disclaimers, see the respective QIAGEN kit handbook or user manual. Trademarks: QIAGEN®, Sample to Insight®,
MinElute®, RNeasy®, TissueRuptor® (QIAGEN Group); Leica® (Leica Microsystems GmBH). 1101195 03/2016 HB-0573-003 © 2016 QIAGEN, all rights reserved.