0% found this document useful (0 votes)
76 views3 pages

Pro Ar G.en GB

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 3

PRO-AR...

19" Rack-Mountable Receiver Multicoupler series for the


VHF through low UHF bands 30 MHz - 960 MHz
DESCRIPTION
Multicouplers with 1 input and 4, 8, 12 or 16 outputs.
For use where a number of receivers have to share the same antenna.
Active wideband receiver multicoupler for the VHF and low UHF bands with 1 input and
4, 8, 12 or 16 outputs.
Allows a number of receivers to share the same antenna without interaction and loss of
signal.
Wide frequency range: Covers 30 MHz – 960 MHz.
If only a smaller frequency range is desired, a preselector filter can be built in to prevent
SPECIFICATIONS
possible interference from strong transmitters outside the frequency band of interest.
Amphenol Procom offer a wide range of both band selective and narrow-band low-loss
Electrical
filters suitable for preselector use.
Please refer to the preselector overview and specify frequency range when ordering. PRO-AR8G-N
Model PRO-AR4G-N PRO-AR12G-N
Other rack-mounted multicoupler series available: PRO-AR16G-N
PRO-ARS: 10 kHz – 108 MHz Gain (Input To All Outputs) 2 dB
PRO-ARU: 690 MHz – 2700 MHz
Frequency 30 - 960 MHz

Ultra-high dynamic range amplifier built in to compensate for loss in multicoupler Noise Figure, Amplifier < 4.0 dB < 6.0 dB

network. Effective Noise Figure All Outputs < 5.5 dB < 8.0 dB
Push-pull high-current amplifier design ensures outstanding multicoupler linearity and Gain Variance < ±2.0 dB
high reject of especially even-order distortion products. Maximum Ouput Power @P1dB > +20 dBm > +17 dBm
Handles even very strong RF signals with negligible levels of IM and harmonic OIP2 > +60 dBm > +50 dBm
distortion. OIP3 > +33 dBm > +25 dBm
Low amplifier noise figure ensures lowest possible S/N deterioration of the received and Impedance 50 Ω
distributed RF signals. Max. 2.5:1
Input SWR
High isolation between receiver outputs. With Preselector: Max. 2.0:1, typ. <1.5:1
Operates on 230 VAC or 115 VAC mains supply or 12 V or 24 V DC supply (depending Output SWR < 1.5:1
on type, see ordering designations). Maximum Input Power (dBm) 18 dBm
Galvanically isolated power supply with power backup function. 30 - 50 MHz: > 18 dB
Automatic switching to DC supply if the mains supply fails. Isolation Between Outputs 50 - 800 MHz: > 20 dB
800 - 960 MHz: > 18 dB
”POWER ON” lamp on front.
Input-Output Isolation > 23 dB > 46 dB
Mains supply connector: IEC type fitted with noise filter.
DC supply connector: Terminal block fitted with noise filter. 230 V models:
198 to 264 VAC 47 - 63 Hz/ Max. 0.16 A
RF connectors: N-female on all ports (other types on request). Power Supply
115 V models:
19” rack module housing. 100 to 127 VAC 47 - 63 Hz/ Max. 0.32 A
Only 1 HU (PRO-AR4G-... and PRO-AR8G-...) PRO-AR8G-... : 1.0 to 1.3 A
Current Consumption 0.6 to 0.7 A PRO-AR12G-… : 1.4 to 1.7 A
or 2 HU (PRO-AR12G-... and PRO-AR16G-...) (1 height unit = 44.45 mm).
PRO-AR16G-… : 1.8 to 2.1 A
Available with black powder lacquered front plate.
DC Supply, 12 V Types 10.8 to 14.4 VDC
Front plate black structure powder painted.
DC Supply, 24 V Types 20 to 28 VDC

Mechanical

Power Connector 3-terminal IEC60320-1 C14 (male)


Connection(s) N female (standard), BNC, TNC or SMA on request
DC Connector 3-pole screw terminal block
PRO-AR4G-..., PRO-AR8G-...: 19" x 1HU x 261 mm
(483 x 44.45 x 261 mm) / (19.02 x 1.75 x 10.28 in.)
Dimensions
PRO-AR12G-..., PRO-AR16G-...: 19" x 2HU x 261 mm
(483 x 89.9 x 261 mm) / (19.02 x 3.54 x 10.28 in.)
Altitude 0 to 2000 m
PRO-AR4G-..., PRO-AR8G-...: Approx. 2.8 kg. / 6.17 lb.
Weight
PRO-AR12G-..., PRO-AR16G-...: Approx. 4.4 kg. / 9.70 lb.

Environmental

Operating Temperature Range -10°C to +50°C


Humidity < 90% non-condensing

Page: 1
Last edited: 2019/02/01
PRO-AR...G

ORDERING MODEL HOUSING

Type Product No. Description PRO-AR4G-N AND PRO-AR8G-N

PRO-AR16G-N 210000111 OUTPUTS: 16 | 230 VAC Supply


PRO-AR4G-N 210000127 OUTPUTS: 4 | 230 VAC Supply
PRO-AR8G-N 210000129 OUTPUTS: 8 | 230 VAC Supply
PRO-AR8G-N-24V 210000152 OUTPUTS: 8 | 230 VAC Supply
PRO-AR4G-N-24V 210000165 OUTPUTS: 4 | 230 VAC Supply
PRO-AR12G-N 210000482 OUTPUTS: 12 | 230 VAC Supply
PRO-AR16G-N-24V 210001183 OUTPUTS: 16 | 230 VAC Supply
PRO-AR12G-N-24V 210001638 OUTPUTS: 12 | 230 VAC Supply
PRO-AR4G-N-115V/12V 210001711 OUTPUTS: 4 | 115 VAC Supply
PRO-AR4G-N-115V/24V 210002596 OUTPUTS: 4 | 115 VAC Supply
PRO-AR8G-N-115V/12V 210000250 OUTPUTS: 8 | 115 VAC Supply
PRO-AR8G-N-115V/24V 210001089 OUTPUTS: 8 | 115 VAC Supply PRO-AR12G-N AND PRO-AR16G-N
PRO-AR12G-N-115V/12V 210002597 OUTPUTS: 12 | 115 VAC Supply
PRO-AR12G-N-115V/24V 210002598 OUTPUTS: 12 | 115 VAC Supply
PRO-AR16G-N-115V/12V 210002599 OUTPUTS: 16 | 115 VAC Supply
PRO-AR16G-N-115V/24V 210002600 OUTPUTS: 16 | 115 VAC Supply

MODEL HOUSING - BACK SIDE


PRO-AR8G-N

PROCOM A/S reserves the right to PROCOM A/S • Smedetoften 12 Page: 2


amend specifications without prior notice DK03600 Frederikssund • Denmark Last edited: 2019/02/01
PRO-AR...G

LOW-LOSS PRESELECTOR FILTERS FOR PRO-AR...G, OVERVIEW


Band selective standard blackbox filters (other filters on request)

TYPE DESIGNATION FILTER TYPE PASS BAND FREQUENCY RANGE

BPF 66-88 Band pass 66 - 88 MHz


BPF 88-108 Band pass 88 - 108 MHz
BPF 112-136 Band pass 112 - 136 MHz
BPF 118-137 Band pass 118 - 137 MHz
BPF 118-174 Band pass 118 - 174 MHz
BPF 136-225 Band pass 136 - 225 MHz
BPF 146-174 Band pass 146 - 174 MHz
BPF 174-240 Band pass 174 - 240 MHz
BPF 210-225 Band pass 210 -225 MHz
BPF 225-400 Band pass 225 - 400 MHz
BPF 300-500 Band pass 300 - 500 MHz
BPF 800-1000 Band pass 800 - 1000 MHz
LP 174-FME Low pass 0 - 174 MHz
HP 380-FME High pass 380 - 1000 MHz
High slope band selective standard PRO filters (other filters on request):

TYPE DESIGNATION FILTER TYPE PASS BAND FREQUENCY RANGES STOP BAND ATTENUATION / FREQUENCY RANGES

PRO-BPF 118-144-N Band pass 118 - 144 MHz ≥ 45 dB 0-108 MHz and 170 - 520 MHz
PRO-LPF 225-N Low pass 0 - 225 MHz ≥ 50 dB 267-500 MHz
PRO-HP144-N High pass 144 - 1000 MHz ≥ 60 dB 0-108 MHz
PRO-HP225.N High pass 225 - 1000 MHz ≥ 70 dB 0-175 MHz
Narrow band standard BP filters:

TYPE DESIGNATION FILTER TYPE CENTER FREQUENCY -1 dB BANDWIDTH

BPF 4/4-[BW] Band pass To be ordered within 66 - 88 MHz To be specified as 2, 4 or 6 MHz


BPF 3/4 Band pass To be ordered within 112-136MHz 1.5 MHz
BPF 2/4-[BW] Band pass To be ordered within 144-175MHz To be specified as 2, 4 or 6 MHz
BPF 70/4-HX Band pass To be ordered within 380-470MHz To be ordered within 3-15 MHz
BPF 900/4 Band pass To be ordered within 820-960MHz Typ. 7 MHz

HOW TO ORDER CUSTOMIZED TYPES

PRO-AR 8G -N(f) -BPF -115V/24 V

↓ ↓ ↓ ↓ ↓
Series No. of outputs Connector type Preselector filter** Supply voltage
4 outputs = 4G No filter = blank* 230VAC/12 VDC = blank*
N-female = -N(f)
8 outputs = 8G Band pass = -BPF 230VAC/24 VDC = -24 V
PRO-AR TNC-female = -TNC(f)
12 outputs = 12G High pass = -HPF 115VAC/12VDC = -115 V/12 V
BNC-female = -BNC(f)
16 outputs = 16G Low pass = -LPF 115VAC/24VDC = -115 V/24 V
* "blank" means sign omitted.
** Preselector pass band [MHz] to be stated after the ordering designation.

EU DECLARATION OF CONFORMITY
Hereby Amphenol Procom declare that the product type PRO-AR...G is in compliance with EU Directive 2014/53/EU.
The full text of the EU Declaration of Conformity is available at:

/images/shop/catalog/pdf-for-catalouges/Declaration-of-Conformity-PRO-ARxG.pdf