DNFT
ARIEL Corporation 07.05.01
35 Blackjack Rd.
R Mount Vernon, Ohio 43050
DIGITAL NO-FLOW TIMER (740) 397-0311 Fax (740) 397-3856
U.S. PAT. NO. 5,835,372
ARIEL # A-10773
SPECIFICATIONS
Material..................................................Stainless Steel, Aluminum
U.S. PAT. NO. 5,835,372 o o
DIGITAL NO-FLOW TIMER
R
LED-PS
Switch Rating..........................................................2.5VA/240 VDC
MODEL
R
Factory Sealed
II 2G EEx m IIB T5
CE
RATED
SERIAL #
2.5VA / 240VDC
Epoxy Encapsulated..............................UL LISTED EL-CAST VFR 64
A-10773
Alarm/Shutdown.................... Factory default for 45 Second Alarm
C US
Cl I; Zone 1; Ex md IIC T4 ARIEL PN
186200 Cl I; Div 1; Grps. A,B,C,D;T4 0344
ALARM 45- SEC
KEMA 00ATEX1090 X Amb. -40° C...+85°C
RED-Open Loop ORANGE-Closed Loop GRN-GND YEL-PROX. SWI.
Power.......................................Field Replaceable - Lithium Battery
DNFT-LED-PS Battery................................................................Ariel P/N A-10807
Divider Block Application.........................................Lincoln O-Ring
Warranty............................................................................2.5 Years
MONITORS MOVEMENT OF DIVIDER
RATINGS
VALVE PISTON FOR DEPENDABLE
"TIMED" SHUTDOWN PROTECTION
C
R
US
II 2G EEx m IIB T5
Cl I; Zone 1; Ex md IIC T4
CE
186200 Cl I; Div 1; Grps. A,B,C,D;T4 0344
CLOSED LOOP OR OPEN LOOP OPERATION
KEMA 00ATEX1090 X Amb. -40° C...+85°C
TROUBLESHOOTING DNFT-LED
NOTICE: WHEN MORE THAN ONE DNFT IS INSTALLED ON THE COMPRESSOR OR ENGINE, EACH DNFT MUST BE WIRED TO A SEPARATE ALARM
CIRCUIT ON THE CONTROL PANEL, ANNUNCIATOR OR PLC TO SIMPLIFY TROUBLESHOOTING THE LUBRICATION SYSTEM AND DNFT.
SPRING
Loosen set screws, remove DNFT from magnet housing. Remove magnet
MAGNET SPACER
B. Spring or Magnet is assembly from divider valve. Remove magnet, spacer and spring. Check
Broken in Magnet components for damage. Replace damaged spring and/or magnet and install on
Assembly divider valve. If necessary, adjust DNFT, check for LED blink. Purge air from
MAGNET HOUSING (HEX) system with lubrication system purge gun.
Remove the battery from the DNFT per the attached instructions. Replace the
C. Low Battery voltage battery if the voltage is below 2.5 volts using a factory recommended replacement
battery.
Loosen set screws, remove DNFT from magnet housing. Check for damaged or
D. Bent Magnet Housing bent magnet housing. Remove magnet assembly from divider valve. Replace
STRAIGHT OK !
magnet housing, magnet, spring and spacer. Re-install DNFT on magnet
BENT REPLACE !
housing. If necessary, adjust DNFT, check for LED blink. Purge air from
system with lubrication system purge gun.
7/16"-20
DNFT-LED-PS
24S PISTON ENCLOSURE PLUG
Lincoln O-Ring Seal
DIVIDER VALVE Magnet Assy # A-6508
Extended Nose
CAUTION: DISCONNECT ALL WIRING PRIOR TO WELDING ON COMPRESSOR OR SKID. 7/16"-20
527LIT A-10773-3
35 Blackjack Rd.
R
Mount Vernon, Ohio 43050
DIGITAL NO-FLOW TIMER
U.S. PAT. NO. 5,835,372 (740) 397-0311 Fax (740) 397-3856
ARIEL #A-10773 DNFT-LED-PS DIGITAL NO-FLOW TIMER WITH DEDICATED PROXIMITY SWITCH.
INSTALL ON LINCOLN* DIVIDER VALVE WITH O-RING SEALS. SWITCH RATING 2.5VA 240VDC
1. Loosen all Allen head set screws (A) on DNFT (B) and remove magnet housing (C). Do not remove magnet, spring or
spacer from magnet housing.
2. Remove piston enclosure plug (D) from end of divider valve where DNFT will be installed. The DNFT does not have to be
installed on the top divider valve. It may be installed on any convenient divider valve, top to bottom. (Notice:Do not install
DNFT on Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.)
3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C). Screw magnet housing (C) into end of divider valve
(E). Torque to 15 foot pounds max.
4. Slide DNFT (B) all the way onto hex of magnet housing (C). Tighten set screws on hex of magnet housing. Torque 25 inch
pounds max.
5. The LED on the DNFT indicates each divider valve cycle. This enables operator to adjust the lubricator pump for correct
cycle time and oil consumption recommended by compressor manufacturer. If LED does not blink with compressor running or
by manually pumping oil into divider valve, the DNFT must be adjusted. Normal cycle indication is a bright strobe type blink.
6. Before adjusting DNFT, divider valve must be cycling. This can be achieved with the compressor running or by manually
pumping oil through the divider valve assembly with a hand priming pump.
7. Adjustment is made by sliding the DNFT (B) all the way on the hex of the magnet housing (C). Tighten set screws on hex of
the magnet housing to 25 inch pounds max. Check for LED blink to confirm correct adjustment. If LED does not blink with
divider valve cycling, adjust the DNFT back in 1/16" increments. Correct adjustment of the DNFT is confirmed by blinking LED.
8. All conduit and connections should be appropriate for area classification. Notice: Conduit and fittings must be supported to
avoid bending magnet housing.
9. After installing magnet assembly and pre-compressor start-up, it is absolutely necessary to purge all air from
divider block lubrication system. This can easily be accomplished with a lubrication system purge gun.
10.DNFT must be installed with correct magnet assembly for each divider valve manufacturer.
Lincoln-7/16"-20 extended nose with O- ring
Trabon-1994 or earlier 7/16"-20 with metal crush gasket Trabon-1995 and later 7/16"-20 with O-ring
Notice: When installing more than one DNFT, each DNFT must be wired to a separate alarm circuit
of the control panel, annunciator or PLC to simplify troubleshooting the lubrication system and DNFT.
O-RING OR ALLEN HEAD
METAL GASKET DNFT SET SCREWS(2) #22 AWG 18" LEADS (7)
(F) MAGNET
(B) (A) SPACER SPRING (I)
INTERNAL VIEW OF HOUSING
DIVIDER VALVE (C)
RED
R
U.S. PAT. NO. 5,835,372 RED RED
DIGITAL NO-FLOW TIMER RED ORANGE
MT. VERNON,OHIO ORANGE ORANGE
CYCLE INDICATION MODEL LED-PS ORANGE GREEN
Factory Sealed RATED 2.5VA / 240VDC
GREEN YELLOW
24S C
R
US
II 2G EEx m IIB T5
Cl I; Zone 1; Ex md IIC T4
CE
186200 Cl I; Div 1; Grps. A,B,C,D;T4 0344
SERIAL #
ARIEL PN A-10773 YELLOW LED YELLOW
ALARM 45-SEC YELLOW
KEMA 00ATEX1090 X Amb. -40° C...+85°C
RED-Open Loop ORANGE-Closed Loop GRN-GND YEL-PROX. SWI. MAGNET FIELD REPLACEABLE
BATTERY
(H) ARIEL P/N: 10807
DNFT-LED-PS O-RING
24S PISTON ENCLOSURE PLUG (F)
(D)
1/2“ PIPE PLUG
DIVIDER VALVE
CONTROL HOUSING POLARIZED CONNECTOR
(E)
CAUTION: DISCONNECT ALL WIRING PRIOR TO WELDING ON COMPRESSOR OR SKID.
WIRING LEGEND
RED..................NORMALLY OPEN OPERATION
ORANGE..........NORMALLY CLOSED OPERATION
ARIEL # A-10773
GREEN.............CASE GROUND
YELLOW...........DEDICATED PROX. SWITCH
UNIT MUST BE SECURELY GROUNDED. DISCONNECT ALL
WIRING PRIOR TO WELDING ON SKID.
ORANGE
ORANGE
INSULATE
FROM CONTACT ORANGE
35 Blackjack Rd.
R
Mount Vernon, Ohio 43050
DIGITAL NO-FLOW TIMER (740) 397-0311 Fax (740) 397-3856
U.S. PAT. NO. 5,835,372
3. Remove the battery from the DNFT and disconnect from the polarized connector.
6. Verify the DNFT is working by pre-lubing the system and check for LED blink.