This document discusses different methods of electric braking for DC motors, including rheostatic, plugging, and regenerative braking. Rheostatic braking works by disconnecting the armature from power and connecting a rheostat across it for shunt motors or reversing field connections and adding a rheostat in series for series motors. Plugging braking reverses the armature connections, causing back EMF and applied voltage to add and increase current, requiring a rheostat to limit it. Regenerative braking reduces applied voltage below back EMF, reversing current flow and sending power back to the line as the motor acts as a generator during braking.

Uploaded by

Asit Mondal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views2 pages

Breaking of DC Motor

This document discusses different methods of electric braking for DC motors, including rheostatic, plugging, and regenerative braking. Rheostatic braking works by disconnecting the armature from power and connecting a rheostat across it for shunt motors or reversing field connections and adding a rheostat in series for series motors. Plugging braking reverses the armature connections, causing back EMF and applied voltage to add and increase current, requiring a rheostat to limit it. Regenerative braking reduces applied voltage below back EMF, reversing current flow and sending power back to the line as the motor acts as a generator during braking.

Uploaded by

Asit Mondal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Electric Braking Of DC Motor

A running motor may be brought to rest quickly by either mechanical braking or electrical
braking. The mechanical braking is applied by means of mechanical break shoes. Hence the
smoothness of mechanical braking is dependent on the surface and physical condition of
brakes. Smooth braking of a motor can be achieved by electric braking.

Electric Braking
The electric braking of dc motor is of three types, (i) Rheostatic or dynamic braking, (ii)
Plugging or reverse current braking and (iii) Regenerative beaking.

(i) Rheostatic or dynamic braking:


In case of DC shunt motors, armature is disconnected from the supply and a rheostat (variable
resistor) is connected across it. The field winding is left connected across the supply.
Obviously, now armature is driven by the inertia and hence machine starts acting as a
generator. Thus the machine will now feed the current to the connected rheostat and heat will
dissipate at the rate of I2R. Braking effect is controlled by varying the resistance connected
across the armature.
In case of DC series motor, motor is disconnected from the supply and field connections are
reversed and a rheostat is connected in series. The field connections are reversed to make sure
that the current through field winding will flow in the same direction as before.

(ii) Plugging or Reverse current braking:


In this method, armature connections are reversed and hence motor tends to run in opposite
direction. Due to reversal of the armature terminals, applied voltage V and back emf Eb starts
acting in the same direction and hence the total armature current exceeds. To limit this
armature current a variable resistor is connected across the armature. This is similar for both
seriesandshuntwoundmethods.
Plugging gives greater braking torque as compared to rheostatic braking. This method is
generally used in controlling elevators, machine tools, printing presses etc.

(iii)Regenerativebraking:
Regenerative braking is used where, load on the motor has very high inertia (e.g in electric
trains). When applied voltage to the motor is reduced to less than back emf Eb, obviously
armature current Ia will get reversed, and hence armature torque is reversed. Thus speed falls.
As generated emf is greater than applied voltage (machine is acting as a DC generator), power
will be returned to the line, this action is called as regeneration. Speed keeps falling, back
emf Eb also falls until it becomes lower than applied voltage and direction of armature
current again becomes opposite to Eb.