XGQ-25F, 50F User Manual
XGQ-25F, 50F User Manual
XGQ-25F, 50F User Manual
WASHER EXTRACTOR
USER MANUAL
1
CONTENT
CHAPTER 1 FOREWORD
CHAPTER 2 INSTALLATION
2
3.5 INSTRUCTION
5.1 OUTLINE
5.2 DAILY NECESSARY REGULATIONS
CHAPTER 6 MAINTENANCE
6.1 OUTLINE
6.2 DAILY MAINTENANCE
6.3 WEEKLY MAINTENANCE
6.4 MONTHLY MAINTENANCE
6.5 YEARLY MAINTENANCE
6.6 STAINLESS STEEL MAINTENANCE
3
7.1 OUTLINE
7.2 ELECTRICAL MEASUREMENT
7.3 INVERTER
7.4 DRAIN VALVE
7.5 WATER AND STEAM INTAKE VALVE
7.6 DOOR
7.7 DOOR INTERLOCK STRUCTURE
7.8 OVERVIBRATION SYSTEM
7.9 BELT ADJUSTMENT AND REPLACEMENT
7.10 BEARING AND MAIN SHAFT SEALING
7.11 MOTOR
7.12 FLUVIOGRAPH
7.13 SHOCK ABSOBER
7.14 WATER AND STEAM STRAINER
7.15 PNEUMATIC CONTROLLOR
8.1 OUTLING
8.2 TROUBLE SHOOTING
4
CHAPTER 1 FOREWORD
1.1 Outline
All machines mentioned in this manual are equipped with inverters including
XGQ-50F and XGQ-25F.
“Sea Lion” XGQ series fully –auto commercial washing machine is a patent
product named “suspension type fully-auto washing and extractor “(patent
No. ZL 96212408.7) developed by our technicians.
It is especially designed for modern laundry. All technical characteristics
have come up to world advanced level.
The equipment has been widely used in hotels, restaurants, hostels, hospitals,
and troops, laundering and dyeing industry, colleges and universities, etc.
It is an ideal equipment for washing cotton, woolen, linen and chemical
fabric. It has the advantages of efficient loading capacity, satisfied washing
result, saving energy, low noise, small and shock, fine appearance and good
design, etc. Thank you for choosing our equipment. Any good suggestion on
improving quality will be warmly welcome.
5
With a couple of automatic washing programs, operator may select,
design or program optionally to get flexible and optimum washing result.
4) The whole drum and single door are easy for operator to load and unload.
5) Operator may change operating forms between automation and manual
optionally. Operator may select different items by pressing button, such
as washing cycle, times of rinsing, extracting time, water level control.
6) Control valves are controlled by pneumatic control system.
7) All control parts adopt 24VDC components for safety and easy
maintenance.
8) With a door safety lock up device, the door will not be opened while
operating.
9) It is equipped with cold / hot water and steam connectors for customers.
10) Both drum and washing case are made of stainless steel with the
advantages of smooth surface, high strength, resistant to corrosion and
durable.
11) The electrical control box is built inside. With a small size and fine
appearance, it is easy to be transported and installed.
12) V belt makes the drive system stable, reliable, low noise and easy to
maintain.
13) Adopting single conversion motor to get a stable speed between washing
and extraction. 30 percent power will be economized compared with
common motor.
14) Equipped with intelligent self-checking system, general operation steps
will display on the panel to show you how to solve trouble while a wrong
operation or an error exists.
15) The automatic agent feeder is separated into few. Operator may feed
washing agent once before starting.
16) Adopting fully sealed frame structure and draining sewage from rear side,
there is no leakage or pollution problem.
6
Item Unit XGQ-50F XGQ-25F Remarks
Rated capacity Kg 50 25
Drum D╳L mm ∮1060╳754 ∮870╳615
7
Table 1.3
CHAPTER 2 INSTALLATION
8
2.2 Dimensions
For detailed dimensions, please see the sketch later on. In order to maintain
and repair the machine easily in the future, a certain space should be
considered while installing. It is suggested that the minimum space should be
as follows:
Front side: 2M
Both sides: 1M
Rear side: 1M
In case that several machines will be installed in a laundry, the minimum
space between two machines should be 0.8 meter at least.
2.3 Unpacking
The machine is packed by crate and waterproof material. While unpacking,
please remove the top and sides first, then you’ll find that the machine is
firmly fixed on the base by bolts. After removing the bolts, the machine may
be moved.
2.4 Inspection
After unpacking, please check the machine and all parts promptly .In case
that any part has been damaged, it must be replaced before installation.
If the machine was damaged before shipment, please give clear indication on
dispatch list. If the machine is damaged after dispatch, please inform the
transport company to check, and raise a relevant claim.
After unpacking, please check all documents, parts and spare parts, If there
is anything damaged or missing, please raise it to the responsible
organization.
9
2.5 Removing and Positioning
Warning: Don’t remove the yellow transport holder before the machine
has arrived at its proper position!
10
(3) Lift the machine on the foundation with proper distance and put in four
bolts higher than ground with certain length in accordance with drawing,
then pour concrete. The bolts must be vertical to the bottom surface of
the machine.
(4) After the foundation gets hard, put the machine down and begin to install.
If the ground is not level, it can adjust by spacers.
After the machine has been finally located. The yellow holder might be
removed. Then check all connectors whether they are loose after long
distance delivery. If it is true, tight them promptly.
Warning:
Wiring and grounding jobs must be done by qualified electrician in
accordance with relevant electric regulations.
For selection of electric source and breaker, refer to Table 2. Each machine
must have an independent branch circuit. Don’t use the same circuit with
lighting or other equipment.
The currency will be over 2 times compared with normal loading operation
while extracting or speeding up. In order to keep safety and run in good
condition, the machine must be grounding firmly in accordance with national
standards or other regulations. Ground wire must be connected with ground
or cold water metal pipe under ground firmly. Never connect the ground
wire or ground wire terminal with the neutral terminal in electric box. For
11
any incorrect connection, our warranty will automatically cease to be in
force.
Therefore all wiring jobs must be connected by a qualified electric
installation.
Customer must use correct and standard shielded wire in flexible conduit.
Wiring and installing should be in accordance with relevant electric
regulations.
After finishing wiring, please start the machine and check rotary direction of
the drum while extracting, it should run in clockwise while operator faces to
the loading door. In case of wrong direction, power cord should be re-
connected.
12
Warning:
Before you have fully understood the functions and operation of the inverter,
please don’t change its internal setting at will. Otherwise our company will
not be responsible for any damage.
XGQ-
1” 25 0.2-0.3 3/4” 20 0.3-0.5 50 100 1100
50F
XGQ-
1” 25 0.2-0.3 3/4” 20 0.3-0.5 50 100 650
25F
It is suggested that:
1) It is better to use flexible pipes to connect with all water inlet pipes of the
machine.
For connecting, refer to relevant requirement.
2) Rinse water pipe to remove dirty. Check water inlet valves and strainers
whether they are connected correctly and no dirty inside.
Warning:
If the drainage capacity dose not to reach the requirement, it will cause
an accident and loss.
After finishing installation, pipe and wire connection, check all connectors
whether there exists loose caused by long distance transport. Then re-cover
all panels.
After finishing installation, clean the machine and then adjust it as follows
while unloading:
1) Check the power to make sure that all wiring are correct and confirm the
parameters meet the requirements.
2) Open the ball valve of air treating unit and provide compressed air in
accordance with requirements.
3) Open water and steam inlet valve.
4) Switch on power.
5) Check over-vibration control system whether the switch is in good
condition. It will show an alarm code and send out a signal.
Warning:
Before starting the machine every day, operator must confirm whether the
over-vibration switch is in good condition. Otherwise it is not allowed to
start the machine.
Warning:
Before starting every day, operator must check the door locking function
with above ways to make sure that the door locking system is in good
condition.
then try to open the door. Right now, the door should be impossible to be
opened.
7) Operate the machine for a whole cycle to check water inlet valve, steam
valve and drainage valve. Meanwhile check washing, distributing and
extracting function.
8) The drum must run clockwise while extracting. Otherwise please change
the wire connecting.
9) Please check all legs of the machine whether they keep the same level
surface while adjusting the machine.
If unloading adjustment is up to standard, then put into material for loading
adjustment.
16
2) Start air compressor, while pressure reaches 0.4-0.5 MPa, please open
the manual ball valve and adjust the pressure up to 0.45-0.5 MPa, then
lock it and don’t always adjust it.
3) Open steam, hot and cold water valve .If customers do not own hot water,
please stop up hot water pipe.
4) Switch on main power and control box.
5) Open the loading door and put washing material into drum, then lock the
door, start the machine and
begin to wash.
1. Press one of the keys according to the washing material or press “Prog.
Up” “Prog. Dn.” to select the wishing program, then press “Start” and
begin to wash automatically and finish the whole program one by one.
2. If you want to modify time or temperature for one step while
automatically washing, you may adjust press and “Time” “Temp. ” and
adjust them while running.
3. You may program according to your special requirements.
4. For details of (2) and (3), see “ GW-32 Microcomputer Operation
Manual”.
17
3.3 Cleaning Operation Section
3.3.1 Manual Operation
a. Preliminary washing (needn’t detergent)
b. Press “Cool Water” until water reaches setting level.
c. Press “Wash” and begin to run in two directions (2-3 minutes).
d. Press “Drain” and let all dirty water run out, then close it.
3.3.2 Washing
a. Press “Cool Water”, ”Heat” and “Supply” valve,(Notes: Operator
must open cold and hot valve for 30 seconds first ,then open the heat
valve.)If customer has hot water, operator may open cold water valve,
hot water valve and steam valve .If it is needed to disinfect, operator
may open the heat valve (steam valve). Temperature can be selected
by operator. The valves must be closed when reaches the set level.
b. Press “Wash”, operator may select washing time about 10-20
minutes depending on dirty condition.
c. While water temperature reaches the needed degree, operator may
press “Heat” again and heat will stop at once. Otherwise, it will close
automatically.
Temperature can be set by pressing “Temp” in advance.
18
b. Press “Wash” for 3-4 minutes, press “Wash” again to stop.
c. When drum has stopped, press “Extract”, middle extraction will run.
After 1-2 minutes, press the key again to stop.
4.1 Outline
19
All of panels in different sides are made of high quality stainless steel with
advantages of corrosion resisting, anti-rust and excellent appearance .The
frame is welded by high quality carbon section steel, so it has good features
of strength, stiffness and durableness.
The case is made of high quality stainless steel. Both front and rear flange
plates are made of good quality and thick steel plate. The inner side is made
of stainless steel plate too. The drum is made of high quality stainless steel
which looks smooth and fine. In order to prevent rust and pollution from iron
in to washing material and prolong the service life of fabric, all parts meeting
with water are made of stainless steel.
There are two heavy bearings in bearing seat. Normally, its service life will
excess over 10 years .For main bearing, adopt a new type sealing structure
with several high strength sealing rings inside to ensure a door sealing result.
There is a buffer and hydraulic damper system between case and frame.
Such full –suspension may reduce the shock greatly. So the machine can be
used at high floor of building.
There is a perfect protection device for door system. With a beam and frame
press structure, it makes the sealing system bear a pressure evenly and get a
long service life.
With a single motor inverter, it makes control system simple, reasonable,
easy to maintain .The operation is easy and reliable because of adopting
microcomputer controller.
4.2 Case
Case here means main washing case including washing liquid, bearing seat,
drum and all of driving parts. After removing all panels, you may find that a
complete case is suspending on the frame.
The tank is also called washing cylinder made of stainless steel to ensure
fabric not to be polluted by iron. Inside the front and rear wall of the case are
covered with stainless steel plate. Parts touching with liquid including
sewage conduit and drainage valve are made of stainless steel.
Points for attention: The water inside cylinder must be drained off
completely while finishing job every day. Before starting the first cycle
20
every day, please press the drainage key to drain rest water because
deteriorating water may influence washing fabric.
4.3 Drum
Drum is the center part of a machine .It is made of high quality stainless
steel .It consists of cage for loading garments and main shaft. There is a
suspending beam between drum and main shaft. It is supported by two roller
bearings for 50F and 25F with different types of 53520,53518 and 53516,
53514 respectively.
Warning:
The main power must be cut off before open rear panel while you
check or adjust belt!
21
suspended on the anti-shock system located on the frame. While operating,
dynamic load makes the case shock, the anti-shock system had the functions
of anti-shock and shock-absorb. At the ends of connecting spring have
spherical plain bearings.
Warning: The brake time is set after many times test,it couldn’t be
changed casually.
The inverter brake process is the process of brake resistance
dischargeing ,so it is forbidden to touch the brake resistance during the
equipment braking
22
Points for attention: Please take care of the loading capacity of the
machine while putting washing material into the drum!
Warning: Operator may open the door while the machine does not run
and there is no water in the machine. It is forbidden to force running
(except flicker while taking out garments.) while the door is opened!
Don’t force to open the door while the pressure of safety system is not
enough. It is because that the door is locked at the moment.
Warning:
Before operation, make sure that all panels have been recovered.
Warning:
Don’t change any set parameter of the inverter, except personnel in this
field.
Warning:
The external power supply must be cut –off before doing
mechanical and electrical maintenance!
5.1 Outline
This is the most important chapter of User Manual .It mainly narrates some
safety regulations which must be obeyed while operating and maintaining .It
is suitable for any operator or maintainer.
26
h. While extracting, if the air pressure is too low or the drainage valve has
any trouble, operator should stop and check the machine immediately to
avoid damaging caused by overloaded extracting.
i. Don’t cut-off power and air artificially while washing to avoid any
unnecessary loss.
j. Don’t start and operate the machine before all panels are recovered.
k. In order to avoid any unexpected accident while washing, operator
shouldn’t leave the machine casually.
l. Don’t change any setting parameter of the inverter casually, except
personnel in this field.
m. While sealing parts become aging and leaking, please adjust or replace it
at once.
n. Make sure that the machine has been grounded firmly.
o. While automatically operating, if you find that water level is too low,
please press Cool Water until reaching the required level.
p. Always check the working condition of each sensor.
1) Check water level sensor whether the tested valve is in accordance with
actual number.
2) Check each thermal sensor whether the showing temperature is correct or
not.
3) Check the pressure gauge whether it is in good condition or not.
q. Always check the belt, if it is loose, please tight it immediately.
r. While maintaining, don’t spray the machine with water to avoid short
circuit and other damage.
s. Don’t use any volatile or inflammable or explosive materials inside or
near the machine.
Chapter 6 Maintenance
6.1 Outline
Though the machine is well designed and manufactured daily maintenance
has been reduced as less as possible, some necessary daily maintenance must
be done. Then the machine will have a long service life and create good
profit.
27
b. Before operation, please check the door interlock function whether it is in
good condition or not.
c. Check the drainage valve.
d. Clean and flush the agent box, clean the box cover.
e. Clean the front, rear and side panels.
f. Drain off the water from the air dehydrator and inject lubricate (sewing
machine oil) into oil atomizer.
g. Check all stop valves to make sure no leakage.
h. Check the door sealing condition carefully .If there is any leakage, please
maintain or replace it at once.
Warning:
Before maintenance, make sure that the main power of the machine
has been cut off!
Important Explanation:
After finishing weekly or monthly maintenance, any panel must be
returned its original place.
28
6.5 Yearly Maintenance
a. Check working condition of each motor and make sure that all of them are
in good condition.
b. Replace seriously damaged or worn parts, such as belt.
c. Check bumper springs whether they are in good condition or damaged.
d. Conduct a rust prevention treatment for the machine.
29
7) Some parts made of iron or steel such as nail or screw will rust and
influence stainless steel. You may paint thick protective coating on carbon
steel parts to solve this problem.
Points for Attention: Any cleanser or other chemicals used for the
machine inside or outside must follow manufacture’s advice. Some
cleansers may be poisonous or flammable. In case of improperly using,
it might cause hurt. Never use volatile solvent, such as acetone, banana
oil, enamel reducer, tetrachloroethylene, gasoline, benzol, or other
volatile oil as cleaning agent!
7.1 Outline
This chapter will introduce operation and functions of the main parts of this
machine .If there is any unclear point, please consult our headquarter or local
branch.
Warning:
Operator must cut off power, water and steam supply before maintaining,
repairing or opening panel!
7.3 Inverter
30
All washing machines of this series have adopted inverter to change and
adjust speed, such structure has following advantages:
1. Compared with non-inverter type structure, it may save energy 30-50%.
2. Improve efficiency and operation quality, reduce the cost of maintenance.
3. The structure is more reasonable.
4. It is easy to implement fuzzy control.
Advice:
1. Don’t open the front cover while switching on or operating, it will get an
electric shock!
2. Don’t touch the inverter terminals while the front cover is removed, in
case of touching high voltage terminal and charging part, people will get
an electric shock!
3. Even if power is cut off, don’t remove the front cover except wiring or
regular checking. Otherwise, connecting inverter charging loop will cause
an electric shock.
4. Please cut off power and wait for 10 minutes, you may measure residual
voltage. Then you may wire or check.
5. The inverter should be grounding independently and firmly.
6. Wiring or checking job must be done by personnel in this specific field.
7. Don’t touch operation switch with moist hand to prevent an electric shock.
8. Motor over-current protection does not make full sure to protect motor
while superheating .It only sends out an output signal.
9. Don’t start or stop inverter frequently.
10. It is easy for inverter to set a high speed. Before changing set parameters,
please check the motor capacity and mechanical property. (Don’t change it
before approved by manufacturer.)
11. Please add holding function of the inverter and fix safety device.
12. Don’t input over-rated voltage to power input terminals (R.S.T). Never
connect power to other terminals, except R.S.T.
13. The operating temperature will seriously influence the service life of
inverter .Try reduce the working temperature as low as possible.
14. Don’t use magnetic contactor between inverter and motor to start
motor .You may control the start /stop through operation switch on the
inverter control board or input terminal (I1, I2)
15. Disconnect wires from inverter while measuring motor insulating
resistance.
16. Don’t force inverter overloading (e.g. over-rated current operating),
it may cause frequency- overload or deadlock.
31
7.4 Drain Valve
Cylinder
Cover board
Platen
Seal Packing
Valve body
Drain pipe
Water drain valve consists of valve body, cylinder, seal packing and platen.
While compressed air passes through the cylinder, it means that the valve
7.1 Water Drain Valve
has an action.
In case that seal packing is aging and leaking, you may dismount valve body
and cylinder from sewage conduit and replace damaged seal packing .In this
Warning:
Don’t force to pull the air pipes.
process, you must number the air inlet and outlet hoses , connectors of
cylinder to avoid confusion while remounting .In case of confusion, the
drainage will be difficult .
In case of confusion, you may press the plastic button on connector and
exchange the air pipe only.
Rotor part
Valve cover Press spring
Piston part
Valve body
33
7.6 Door and Sealing
Lock
Cylinder Handle Frame Seal packing Switch
The door consists of a stainless steel ring mounted with press-frame handle,
hinge door glass and sealing rubber. The door glass is fixed on the stainless
steel ring by platen and bolts .The sealing rubber is coated with strong
adhesives to bond with stainless steel ring. While closing the door, the
34
pressure will press sealed between sealing rubber and flange. After a certain
days, the sealing rubber will be permanent set. You may adjust filler pieces
under the hinge fixed block and lock catch by the means of removing 1-2
pieces.
It is important to keep the concentricity between door and drum to prevent
from damaging garments.
Points for Attention: please keep the removed pieces carefully which
will be used in the future while replacing new sealing rubber.
Advice:
1. You must pay attention to the concentricity between door and drum while
adjusting door- sealing condition.
2. Never use gasoline or other petroleum base products to mop mantle ring
or other rubber products.
3. After finishing daily job, it is suggested to clean sealing rubber with soft
cloth and open the door to make sealing rubber relaxant.
35
Advice:
1. Before starting every day, operator must check whether the interlock
system is in good condition according to the above mentioned methods.
2. Before maintenance, don’t wet the switch to avoid short –circuit.
Advice:
1.Make sure that the over-vibration system is in good condition before
operating every day.
2.It is not allowed to remove over-vibration system.
3.It is suggested that operator should weekly check the trigger whether the
distance is in accordance with the requirement.
Microswitch
Impact head
Spring
Case frange
36
37
Advice:
1.While using a new belt, the fit tolerance of belts should be as small as
possible to keep belts standing force equivalently. (Try to keep the belts in
the same group with the same length.)
2.In the process of tensing, the shaft line of belt wheel should be in
parallel .The symmetrical plane of V belt of each belt wheel should match
together, the tolerance shouldn’t excess 0.2 degree.
3.The central distance should be adjusted as less as possible while replacing
belt. Don’t force to enter in case of any bad effect of V-belt life.
Seal
Conical Round Rear Front Press packing
bushing nut bearing bearing plank seat Seal packing
38
2. Suggestions on replacing main shaft and sealing body:
1) Cut off power, water and steam supply
2) Remove all panels
3) Dismount the door from front flange. Support the drum and case to
prevent from overturning while dismounting the front flange.
4) Loosen screws on conical bushing, then dismount belt wheel.
5) Find and mark relative datum lines in the front of drum and case and at
the rear of main shaft and case respectively for correcting in the future
while re-installation.
6) For XGQ-50F, dismount rear bearing cover and front bearing cover. For
XGQ-25F, dismount rear bearing cover.
7) Loosen round nut of bearing seat group.
8) For XGQ-50F, pull out 4 pieces of tapered cotter from the bearing seat,
loosen the fastener, then pull out bearing seat. For XGQ-25F, use 6 pieces
of ∮8 round steel (with threads on both ends). Screw one end into screw
of rear bearing seat. Set another end with 12mm armor plate and place a
jack between the head of main shaft and armor plate. Press jack to make
main shaft move ahead and separate main shaft from bearing seat.
9) Remove four pressing nut on sealing ring.
10) Replace or repair bearing and sealing element.
39
11) Assemble it with a converse process.
Points for Attention:
1.Inject enough ZL3 lubricating grease.
2.Make sure that all parts keep clean while assembling.
3.Follow the datum line to find the position of drum and case.
4.Before assembling, disassemble and clean conical bushing, then inject
ZL3 lubricating grease. Fasten the nut in diagonal direction gradually
while assembling .The moment value is 81.3 N/M. After running 5
minutes, fasten it again to keep the moment value of 81.3 N/M.
7.11 Motor
All motors are conversion type .So the speed can be adjusted by inverter.
Advice:
1) In case of loudly electromagnetic noise coming from the motor, please
check its voltage.
2) If the motor moment comes down, please check the current values of
different phases are the same or not. If the tolerance excesses 15 %, check
the resistance and input voltage of different windings.
3) In case of suspecting that winding has burned or broken circuit, check
all 3-phase winding with an ammeter. Resistance value should be similar.
7.12 Fluviograph
Fluviograph is an electronic pressure switch to measure water level inside
machine .A connector fixed on sewage conduit is connected with the
machine through nylon hose and pressure switch.
If you find that the measuring result is wrong, please check connecting nylon
hose whether there is leaking, wrong connection or dropsy. The connection
place between air pipe and drainage valve should not hang down. Don’t let
water enter hose.
Advice: Don’t pull the hose connected with fluviograph to avoid leaking.
40
Advice:
It is suggested that monthly check all springs whether there is any crack or
damage, or fatigue deformation, which will cause machine inclining.
Outlet Inlet
Filter mesh cover Direction
Advice:
Clean mesh monthly. (If water quality is bad, clean cycle should be
shortened.) Neglect of installing and cleaning will influence the machine
operation. Following points for attention while cleaning filter:
1) Dismount the cap of mesh.
2) Dismount mesh and other filter elements.
3) Flush the mesh with water to remove all impurities.
4) Put the mesh into filter.
5) Screw the cap of mesh again.
Pressure gauge
Pressure Oil atomizer
Ball valve Filter adjusting
8.1 Outline
This chapter will introduce you how to use the machine efficiently, find and
solve troubles.
Before trouble shooting, please check following respects:
1) To be sure that all operation steps are proper and all connected pipes, and
wiring are in good condition.
42
2) Cut off power before maintaining.
3) Check all joints of wires and pipes. Any loose will influence operation.
4) Check dielectric character of components, make sure that electrical
insulating character is good.
43
and high 3.Sewage has not fully drained damaged spring.
extracting off. 3.Fasten joints which may
be loose or check
drainage valve.
D. Drainage 1.Drainage pipe has blocked. 1. Clean the pipe line
speed is too 2.Something wrong with the 2. Check the pressure of
low. drainage valve compressed air.
3. Replace aging cylinder.
You may find the model number of ex-factory and electrical data of the
machine on name- plate.
All information, diagrams, explanation and technical specifications of this
user manual come from our latest products while printing. All information is
subject to change without prior notice.
45
Our company will not held be responsible for any returning spare parts or
loss caused by a wrong ordering.
Appendix 1
View of Machine
XGQ 25F and 50F
46