0% found this document useful (0 votes)
278 views4 pages

Design of One Way Slab

1. The document provides calculations to determine the minimum thickness, reinforcement requirements, and spacing for a 1-way suspended reinforced concrete slab with given parameters such as live load, concrete strength, rebar sizes, and span length. 2. It is determined that the minimum slab thickness is 109.29 mm and the effective depth is 83.29 mm. 3. The calculations check that the shear stress is below the code limit and that the required area of main reinforcement and spacing are adequate without needing temperature reinforcement bars.

Uploaded by

Sherwin Pons
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
278 views4 pages

Design of One Way Slab

1. The document provides calculations to determine the minimum thickness, reinforcement requirements, and spacing for a 1-way suspended reinforced concrete slab with given parameters such as live load, concrete strength, rebar sizes, and span length. 2. It is determined that the minimum slab thickness is 109.29 mm and the effective depth is 83.29 mm. 3. The calculations check that the shear stress is below the code limit and that the required area of main reinforcement and spacing are adequate without needing temperature reinforcement bars.

Uploaded by

Sherwin Pons
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

1-WAY SUSPENDED REINFORCED CONCRETE SLAB Issue

(NSCP 2010) Date 5/2/2019


Prepared by: smp
Mark
Checked by:

GIVEN
Uniform LL 0.0020 N/mm2
Length, L 3,000.00 mm
Main bar, db 12.00 mm
Temperature bar, dt 10.00 mm
fc' 20.68 N/mm2
fy 230.00 N/mm2
Unit weight of concrete, w 0.000024 N/mm3
Bending 0.90 mm
Shear 0.85 mm

SOLVING FOR MIN THICKNESS


Considering 1m strip of slab, b 1,000.00 mm
Uniform live load, 𝐿𝐿=𝜔𝐿 2.00 N/mm
Minimum slab thickness, h

ℎ_𝑚𝑖𝑛=𝐿/20(0.4+𝑓𝑦/700) 109.29 mm

Effective depth, d

𝑑=ℎ_𝑚𝑖𝑛−(𝑐𝑜𝑛𝑐 𝑐𝑜𝑣𝑒𝑟+𝑑_𝑏/2)
83.29 mm

Weight of slab, 𝐷𝐿=𝜔𝑏ℎ 2.62 N/mm

LOAD (N/mm) DL LL EL
wu 2.62 2.00
𝑤�=1.4𝐷𝐿+1.7𝐿𝐿 7.07 N/mm

�_�=(𝜔_� 𝐿^2)/8 7,956,000.00 N-mm

�_𝑛=�_�/(∅𝑏𝑑^2 ) 1.27 N/mm2

�=(0.85𝑓^′ 𝑐)/𝑓𝑦 (1−√(1−(2�_𝑛)/(0.85𝑓^′ 𝑐)))


�_𝑚𝑎𝑥=0.75<(0.85𝑓^′ 𝑐𝛽1 (600))/(𝑓𝑦(600+𝑓𝑦))
�_𝑚𝑖𝑛=1.4/𝑓𝑦 ≤

0.00609 0.00576 0.03522


FAIL! OK!

𝐴�=�𝑏𝑑 479.55 mm2

SOLVING FOR SPACING, s


Maximum spacing required by code:
3h 327.86 mm
450mm 450.00 mm
�_𝑏=(𝜋𝑏 〖𝑑 _𝑏 〗 ^2)/4𝐴�
235.84 mm OK!

SOLVING FOR TEMPERATURE BAR REQUIREMENT


𝐴_𝑡=0.002𝑏ℎ 218.57 mm2
�_𝑡=(𝜋𝑏 〖𝑑 _𝑡 〗 ^2)/(4𝐴_𝑡 )
359.33 mm NO NEED TEMP
Page
5/2/2019
smp
NO NEED TEMP BARS!