GeomagicControlX ReleaseNotes
GeomagicControlX ReleaseNotes
Release Notes
Software: Geomagic Control X
Version 2018.0.1
Release Date: November 2017
TABLE OF CONTENTS
1 INTRODUCTION 1
COPYRIGHT 1
2 INSTALLATION 2
SYSTEM REQUIREMENTS 2
DOWNLOAD AND INSTALL SOFTWARE 2
ACTIVATE LICENSE 2
4 FIXED BUGS 11
BUG FIXES IN 2018.0.1 11
BUG FIXES IN 2018.0.0 11
1 INTRODUCTION
We are pleased to announce the availability of the new version of Geomagic® Control X™. Geomagic Control X is a comprehensive
metrology software platform that delivers the industry’s most powerful tools within straightforward workflows. With Geomagic Control
X quality managers are enabled with revolutionary ease-of-use, intuitive, comprehensive controls and traceable, repeatable workflows
for the quality measurement process. Its fast, precise, information-rich reporting and analysis enable significant productivity and quality
gains in any manufacturing workflow.
New features in this release were made to deliver intuitive and efficient user experiences. Work more productively with the Ribbon UI.
This release also includes many more enhancements and some bug fixes.
For more information, please visit www.geomagic.com.
COPYRIGHT
©1993-2017. 3D Systems, Inc. All rights reserved. The content of this manual is furnished for informational use only, is subject to
change without notice, and should not be construed as a commitment by 3D Systems, Inc. Any names, places, and/or events in this
publication are not intended to correspond or relate in any way to individuals, groups or associations. Any similarity or likeness of
the names, places, and/or events in this publication to those of any individual, living or dead, place, event, or that of any group or
association is purely coincidental and unintentional.
3D Systems, Inc. 1
2 INSTALLATION
SYSTEM REQUIREMENTS
For the latest system requirements information and to learn about specific qualified system configurations, go to the System
Requirements page in the Geomagic Support Center. Some users have had success running system configurations that deviate from
the supported listed on our website. In such cases, these configurations are not officially supported by 3D Systems, Inc.
Additionally, we test a variety of hardware platforms in combination with the graphics subsystems. While we make every attempt to
be as thorough as possible, hardware manufacturers change their products frequently and may be shipping newer products or have
discontinued active support for others. Check the support section of the website for the latest system requirement information and
specific qualified systems.
ACTIVATE LICENSE
Geomagic Control X requires license activation to run the application on your PC. You can choose to use an evaluation license for a 15-
day period or activate a permanent license by using an Online Activation license or a physical dongle.
After you start your application, the License Utility window opens. The License Utility allows you to activate and use the Geomagic
Control X software.
NOTE: When you launch the License Utility, you can click the Help button to read the Licensing Guide.
You should have received an email from 3D Systems with your activation code. If you have not received an email from 3D systems,
contact them at [email protected].
If you are an existing user and have already activated the license on your PC with the previous version of the application, you can run
the newer version of the application without re-activating the license.
For more information, go to gettingstarted.geomagic.com, select the Geomagic Control X product, then click Licensing.
3D Systems, Inc. 2
3 NEW FEATURES AND ENHANCEMENTS
Deviation Location
Added a new Deviation Location tool to the Compare group in the Compare tab, supporting a particular deviation analysis between
the Reference and Measured Data, or a fitting surface and Measured Data. This tool helps find and analyze surface wear, dents, and
correction on Measured Data.
3D Systems, Inc. 3
New 2D Twist Analysis
Added a new 2D Twist Analysis tool to the Compare group in the Compare tab, allowing you to analyze the deviation of twist angle
between section profiles of the Reference and Measured Data.
3D Systems, Inc. 4
New Probe Location
Added a new Probe Location tool that reports the location of the probe center of a probing device during LiveInspect. This tool helps
you validate alignments, and complete inspection workflows that require on-the-fly probe locations. These locations can also be
recorded as Comparison Points for later use.
3D Systems, Inc. 5
New ASCII Geometry Import
You can now import ASCII-encoded geometry files into the application. Without using CAD files as the Reference Data, you can set up
a systematic inspection process using only imported geometries.
Enhancements
Pairing Manager
The enhanced Pairing Manager tool now enables you to explicitly set alignment conditions when searching for geometry pairs of
Measured Data. Entities can now be grouped for easier management of different searching conditions. Furthermore, the User Interface
has been enhanced for clearer understanding of pairing results.
3D Systems, Inc. 6
Replacing Measured Data
A new Re-Align To Existing Measured Data option has been added to the Replace Measured Data tool, providing quick access to
alignment tools for Measured Data.
Enhanced LiveInspect
The enhanced LiveInspect now fully supports guided probing inspection for positions where simulated CMM points and comparison
points have been defined. In addition, probing requirements for Circles, Slots, and Rectangles have been improved for quicker
acquisition.
3D Systems, Inc. 7
Misc Enhancements
• Display Settings - The visibility of the Global Coordinate System displayed at the system origin can be toggled on or off from the
Display pane.
• File Import
• New support for .WRP and .GEODOC file formats - Users with legacy Geomagic Control files as well as the current Geomagic Wrap
files can now import them directly into Geomagic Control X
• Geomagic Control X now supports up to version 10.0 of the JT file format
• The following tables shows some of the updated CAD file formats that can be imported. For the list of full supported file formats, see
the Geomagic Control X’s User Guide.
CAD Application File Extension Version Supported Comments
R8-R27 • Geometry Only
CATIA V5 .catpart, .catproduct
(V5-V6R2017) • PMI Import Supported
• Geometry Only
CATIA V6 .catpart, .catproduct V62017x
• PMI Import Supported
• Geometry Only
Creo (Pro/E) .prt, .prt.*, .asm, .asm.* Pro/E 16 – Creo 4.0
• PMI Import Supported
Inventor .ipt, .iam V6 - 2017 • Geometry Only
• Geometry Only
SIEMENS NX .prt 11 – NX11
• PMI Import Supported
• Geometry Only
SOLIDWORKS .sldpt, sldasm 98-2017 • PMI Import Supported
(2016-2017)
STEP .stp, .step AP203, AP214, AP242 • Geometry Only
• Grouping Measured Data - Measured Data added in the Result Data tab can now be managed by groups as needed in the
Model Manager.
3D Systems, Inc. 8
• Construction Geometries in the Model Manager - Construction Geometries are now organized in their own entity group within
the Model Manager. Furthermore, changes to icons and entity grouping help clearly differentiate between the different types of
geometries.
• Pairing / Unpairing Geometries - You can now locally pair and unpair constructed geometries directly from the Model Manager.
• Editing Geometries - You can now edit parameters of Reference construction geometries directly from the Tabular View.
3D Systems, Inc. 9
• Enhancements to 3D Compare - The Use Specific Tolerance option is now used by default.
• Performance Improvements - Due to enhancements and upgrades to core algorithms and program architectures, you can ex-
pect overall performance improvements. Noticeably, you will see improvements in the following areas.
• Scan Pair Searching
• Best-Fit Alignment
• 3D Compare
• Point Cloud Handling
• Program Crash - When you encounter a program crash, you can create a bug report with a. DMP file and send it to 3D System to
help resolve the issue.
3D Systems, Inc. 10
4 FIXED BUGS
3D Systems, Inc. 11
Resolved an issue where users could not progress inspection when using RPS alignment and a slot
• GV-4790:
boundary as a circle
Comparison Points using different methods would not be compatible with a probe device. This has been
• GV-4929:
resolved.
• GV-5274: When exiting LiveInspect, the side windows would reset to the default settings
• GV-4951: Fixed an issue where the Pairing Manager and the Properties values would interfere with each other.
• GV-6095: Improved Pair Fitting search results
• GV-4223: Sometimes the Shrinkage value would not be applied in the Pairing Manager
• GV-6398: Resolved a crash when attempting to use the Pairing Manager on Sections.
• GV-3359: Fixed a Reporting issue where a PDF could not be exported with Windows 10
• GV-3581: During Reporting, the active Result will now be focused instead of all Results.
• GV-3712: Fixed a Reporting issue where the Result name would be duplicated
• GV-3903: Fixed a Reporting issue where the incorrect Measured Data name would be applied
• GV-4499: When exporting a report as a PowerPoint in Landscape orientation, images would be incorrectly sized
• GV-4526: Trend Reports were missing SPC values
• GV-4576: 3D Compare groups did not have a template in Layout mode
• GV-4610: Trend Report templates were behaving incorrectly
• GV-4697: The Colorbar would not appear on custom viewpoints
• GV-4717: Delta radius values can now be reported for cylinders
• GV-4739: Report objects will now include versioning information
• GV-4785: Sometimes a crash would occur when editing 2D Compare templates in Layout Mode
• GV-4820: Alignment groups did not have a template in Layout mode
• GV-4851: Field chooser for Report tables had empty values
• GV-5012: Resolved an issue where the font size of tables would change
• GV-5215: Resolved issues when editing SPC values for Trend Reports
• GV-6325: Resolved an issue where Trend Report source files window would be empty
• GV-4282: A crash would occur when selecting a comparison point in Layout Mode
• GV-4952: A crash would occur when editing in Layout Mode after generating a Report
• GV-5923: Adaptive and Homing alignment were missing Result names in the Report
• GV-5926: Adaptive and Homing alignment were missing Result names in the Tabular View.
• GV-6366: When using the Faro Cobalt, the right and left views would continuously switch
• GV-6367: When using the Faro Cobalt, the exposure value was limited to 200
• GV-4586: Changed the hardware interface name of the LDI device to Laser Design Surveyor Scanner
• GV-3606: Improved stability of Colorbar Template management
• GV-4126: When using the software in the French Language, the icon was missing.
• GV-4365: Undo / Redo for Annotation changes did not work
• GV-4525: When exiting LiveInspect, the Model Manager would not revert to previous state
• GV-4616: Viewpoints did not remember Annotation Display Settings
• GV-5172: Improved the annotation view during 2D Dimensioning where annotation arrows would be misplaced
• GV-5836: Could not move the Scanner Setup function when trying to Customize Ribbon Bar
• GV-5876: Angular Deviation and Projected Angle in the tabular view showed the wrong values
• GV-5889: The "Remove Original Data" option was missing in HD Mesh Construction of Mesh Buildup Wizard
• GV-6249: During 2D Compare, the Color Bar options would reset when going to the next stage of the command
3D Systems, Inc. 12
3D Systems, Inc.
333 Three D Systems Circle | Rock Hill, SC | 29730
www.3dsystems.com