The document provides wind loading parameters for a building model in STAAD/Pro, including: - Dimensions and properties of the building being 90.5m long, 101m wide, and 12.25m tall - Basic wind speed of 47m/sec, open terrain category 2, and risk coefficient of 1 - Calculated design wind speed of 44.556m/sec and pressure of 1.191KN/m^2 - Wind pressure and suction coefficients for walls, roof, internal pressure, and rigid frames - Sample wind loads applied to columns, rafters, and frames in three load combinations

Uploaded by

Saurabh Gupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
215 views7 pages

Iito Wall: File:///Conversion/Tmp/Scratch/418555233

The document provides wind loading parameters for a building model in STAAD/Pro, including: - Dimensions and properties of the building being 90.5m long, 101m wide, and 12.25m tall - Basic wind speed of 47m/sec, open terrain category 2, and risk coefficient of 1 - Calculated design wind speed of 44.556m/sec and pressure of 1.191KN/m^2 - Wind pressure and suction coefficients for walls, roof, internal pressure, and rigid frames - Sample wind loads applied to columns, rafters, and frames in three load combinations

Uploaded by

Saurabh Gupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 7

Page 1 Bldg Loads

Wind Loading for MBS/STAAD


Project GOLD STAR
Building 1

L-Length of building (Greater hoz dim. Of bldg.)meters 90.5


w-Width of building Lesser hoz dim. Of bldg.) m 101
h1-Height of plinth m 0
h2-Eaves height from FFL m 12.25
h-Eaves height from FGL m 12.25

Roof Slope 1: 50.0000


Vb-Basic wind speed m/sec 47
N-Design life of structure; mean probable Years 50
Terrain Category 2
Category1- Exposed open terrain with few or no obstructions having heights less than 1.5m.
Category2- Open terrain with well scattered obstructions having heights between 1.5m.& 10m.
Category3- Terrain with numerous closely spaced obstructions having heights around 10m.
Category4- Terrain with numerous closely spaced high obstructions

Class of Building C
Class-A - Structure & or compo like cladding, roofing etc having greatest Hoz Or Vert dim < 20m.
Class-B - Structure & or compo like cladding, roofing etc having greatest Hoz Or Vert dim bet 20-50
Class-C - Structure & or compo like cladding, roofing etc having greatest Hoz Or Vert dim > 50m.

K1-Risk Coeff. 1
HT Max Height of building from FGL m 12.25

K2-Terrain,Str-height &size factor 0.948


K3-Topography Factor 1

Vz-Design wind speed m/sec 44.556


Pz-Design wind pressure KN/m^2 1.191

Cpe-External Pressure coeff for walls w C


Table No.4 IS 875 (Part3) -1987
A B
h
D
Elevation Plan

h/w 0.121
L/w 0.896

Wind Angle A B C D Local


0o ^ to wall 0.7 -0.2 -0.5 -0.5 -0.8
90oIIto wall -0.5 -0.5 0.7 -0.2 -0.8

Cpe-External Pressure coeff for Pitched Roof of Single Span Bldg.


Table No.5 IS 875 (Part3) -1987
Roof Angle in degrees 1.15
Wind Angle 0o ^ to ridge

EF GH

file:///conversion/tmp/scratch/418555233.xlsx 1/7
Page 2 Bldg Loads

Elevation

E G
q
L
Wind
F H

w
Plan

file:///conversion/tmp/scratch/418555233.xlsx 2/7
Page 3 Bldg Loads

Roof Angle-1 0
Roof Angle-2 5

Roof Wind Angleq = 0o Wind Angleq = 90o


Angle EF GH EG FH
0 -0.80 -0.40 -0.80 -0.40
5 -0.90 -0.40 -0.80 -0.40
1.15 -0.82 -0.40 -0.80 -0.40

Local coeff = -2.0

Wind Drag

Cpi-Internal Pressure Coeff 0.5


Opennings not more than 5% of wall area 0.2
Opennings between 5% to 20% of wall area 0.5
Opennings larger than than 20% of wall area 0.7

RIGID FRAME COEFFICIENT

*(23) WIND COEFFICIENTS


*Surf Wind_ 1 Wind_ 2 Long _Wind Surface
*Id Left Right Left Right 1 2 Friction
1 0.2 -0.7 1.2 0.3 -1 0 0
2 -1.32 -0.90 -0.32 0.10 -1.30 -0.30 0
3 -0.90 -1.32 0.10 -0.32 -1.30 -0.30 0
4 -0.7 0.2 0.3 1.2 -1 0 0

FRONT / BACK SIDE WALL

*(19)WIND PRESSURE/SUCTION:
*Wind *Wind
*Pressure *Suction
1.429 -1.191 ..Girt/Header
1.429 -1.191 ..Panel
1.429 -1.191 ..Jamb
1.429 -1.191 ..Parapet Girt

EDGE/ CORNER ZONE (MM) 12250


LOCAL COEFF -1.3
RATIO LOCAL TO AVERAGE 1.3

LEFT/RIGHT ENDWALL

*(38)WIND PRESSURE/SUCTION:
*
*Wind *Wind
*Pressure *Suction
1.429 -1.191 ..Column
1.429 -1.191 ..Girt/Header
1.429 -1.191 ..Jamb
1.429 -1.191 ..Panel
1.429 -1.191 ..Parapet Girt

*(39) WIND COEFFICIENTS


*Surf Rafter_Wind_ 1 Rafter_Wind_ 2 Bracing _Wind Long Surface

file:///conversion/tmp/scratch/418555233.xlsx 3/7
Page 4 Bldg Loads

*Id Left Right Left Right Left Right Wind Friction


1 0.2 -0.7 1.2 0.3 0.2 -0.7 -1 0
2 -1.32 -0.90 -0.32 0.10 -1.32 -0.90 -1.30 0
3 -0.90 -1.32 0.10 -0.32 -0.90 -1.32 -1.30 0
4 -0.7 0.2 0.3 1.2 -0.7 0.2 -1 0

file:///conversion/tmp/scratch/418555233.xlsx 4/7
Page 5 Bldg Loads

ROOF DESIGN

*(38)WIND PRESSURE/SUCTION:
*
*Wind *Wind *Wind
*Pressure *Suction *Suct_Roof
0.119 -1.576 ..Purlins
0.119 -1.576 ..Purlins, Gable Extension
0.119 -1.576 ..Interior Roof Panels
0.834 -0.238 -1.548 ..Long Bracing,Building
1.429 -0.834 ..Long Bracing,Wall Edge Zone
1.429 -0.834 -1.548 ..Long Bracing,Facia/Parapet

EDGE/ CORNER ZONE (MM) 12250


LOCAL COEFF.(INCL INT SUCT.) -2.05
RATIO LOCAL TO AVERAGE 1.549608

file:///conversion/tmp/scratch/418555233.xlsx 5/7
Staad output

Enter the Tributary area on frames in mts 10

Enter the 1st load combination number for wind load 5


Enter the member ids for Left column 1
Enter the member ids for Left rafter 14 15 16
Enter the member ids for Right rafter 13 17 18
Enter the member ids for Right column 10

*********WIND LOAD*******
************WIND PRESSURE LEFT TO RIGHT*********
LOAD 5 WLP
MEMBER LOAD
1 UNI GX 2.382
14 15 16 UNI Y 15.758
13 17 18 UNI Y 10.720
10 UNI GX 8.338

************WIND SUCTION LEFT TO RIGHT*********


LOAD 6 WLS
MEMBER LOAD
1 UNI GX 14.294
14 15 16 UNI Y 3.846
13 17 18 UNI Y -1.191
10 UNI GX -3.573

************WIND PRESSURE RIGHT TO LEFT*********


LOAD 7 WRP
MEMBER LOAD
1 UNI GX -8.338
14 15 16 UNI Y 10.720
13 17 18 UNI Y 15.758
10 UNI GX -2.382

************WINDSUCTION RIGHT TO LEFT*********


LOAD 8 WRS
MEMBER LOAD
1 UNI GX 3.573
14 15 16 UNI Y -1.191
13 17 18 UNI Y 3.846
10 UNI GX -14.294

************WIND PARALLEL PRESSURE*********


LOAD 9 WPP
MEMBER LOAD
1 UNI GX -11.911
14 15 16 UNI Y 15.485
13 17 18 UNI Y 15.485
10 UNI GX 11.911

************WIND PARALLEL SUCTION********


LOAD 10 WPS
MEMBER LOAD
1 UNI GX 0.000
14 15 16 UNI Y 3.573
13 17 18 UNI Y 3.573
10 UNI GX 0.000