Capacity of Plant 16KLD

This document provides design specifications for a sewage treatment plant with a capacity of 16KLD. It includes input characteristics for sewage, dimensions for bar screens and equalization tanks, pump requirements, aeration tank dimensions based on BOD and F/M ratios, dimensions for secondary clarifiers and clear water tanks, and specifications for pressure sand filters, activated carbon filters, sludge holding tanks, and sludge pumps.

Uploaded by

Sandeep K
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views4 pages

Capacity of Plant 16KLD

This document provides design specifications for a sewage treatment plant with a capacity of 16KLD. It includes input characteristics for sewage, dimensions for bar screens and equalization tanks, pump requirements, aeration tank dimensions based on BOD and F/M ratios, dimensions for secondary clarifiers and clear water tanks, and specifications for pressure sand filters, activated carbon filters, sludge holding tanks, and sludge pumps.

Uploaded by

Sandeep K
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Capacity of Plant=16KLD

FOR any STP, details of input characteristics


of sewage are
Input characteristics
Flow rate Ranges Normal value
PH 6 to 9 6.5 to 8.5
BOD inlet 250 mg/l - 400 mg/l 350
BOD outlet 20 mg/l - 30 mg/l 25
COD 400 mg/l - 800 mg/l 500
2000 mg/l - 4500
3500
MLSS mg/l
F/M 0.1 - 0.2 0,12
Oxygen required to
remove per kg of 1.2 - 2 1,2
BOD5
Specific gravity of
Sewage water is
1.1 - 1.2 1,1
more than normal
water

BAR SCREEN
Assume Detention time varies from 3 to 5 mins
Detention time, T=5 min
Discharge, Q= 16 KLD

Discharge, Q= Volume /detention time

Q= Volume/ 5min

Volume=0.06Cum
Depth of Screen chamber varies from 0.5 m to 1 m

Say, Depth =1 m
L=2B , 2B*B=2B2

Area =0,06 Sqm Say Breadth =0,22 m Length=0,45 m


Dimension of Bar screen= 0.9 x 0.5 x 1 m
Let nos. of bars= n
Clear space between bars = 15 mm
Bar thickness = 5 mm
No. of bars =( n x 5)+(n + 1) x Bar spacing=
No. of bars = 10

EQUALIZATION
TANK
Assume Detention time varies from 3 to 8 Hrs
Detention Time, T= 6 Hr
Q= Volume /detention time
Volume = 4 Cum
Assume Depth of tank varies from 2.5m to 3.5m
Depth of tank= 3m
Area of tank = 2 Sqm
Length = 1m
Breadth = 1m
PUMP REQUIREMENT
2 nos of pump ( 1 Working & 1 Stand by)
Volume or Capacity of water to aeration tank, time assumed = 2 Hr
Pump discharge capacity = Capacity of tank /time in hr
Discharge, Q= 2.000 Lts/Hr 0,56 Lts/Sec
Suction head= 15 m ranges from 6 to 20 m
HP= W*Q*H/75*efficiency
HP= 1
Go for higher HP 2
AERATION TANK
Assume inlet BOD= 350 mg/l
Treated water BOD should be range 10 mg/l to 30 mg/l
FM ratio range from 0,1 to 0,2
MLSS ranges from 2000 mg/l to 4000 mg/l
F/M=(Q X BOD inlet)/(volume X MLSS)
Volume = 13,33 Cum
Volume = 14,00 Cum
Depth of aeration tank varies from 2,50 m to 4,00 m

Area of Tank = 4 Sqm


Length = 2,00 m
Breadth = 2,00 m
Dimension of Aeration tank can be altered based on site condition with depth not more than 4
m
Dimension of aeration tank =

2mX2mX3.5m

AIR BLOWERS IN AERATION TANKS


Pump Capacity , HP 3,00 HP
SECONDARY CLARIFIER (SETTLING TANK)
SOR to be considered as = 15 Cum/Sqm/day
Area of Tank = 1,07 Sqm

Dimension of aeration tank= 1.4mX1.4mX2.5m

CLARIFIED (CLEAR) WATER TANK


Detention time ranges as per site condition. 2 hrs
Volume of tank = 2,67 Cum

Dimension of Clarifier tank =1.0mX1.0mX3.0m

PRESSURE SAND FILTER (PSF)

Flow rate to sand filter =0,6667 Cum/Hr

Dimension of PSF tank = 0.4dia in m X 1,8m

ACTIVATED CARBON FILTER (ACF)


Flow rate to sand filter =0.67m3/hr

Assume Detention time =15 min

Dimension of ACF tank = 0.4 dia in m X 1.8 m\

Pump capacity required to feed the clarifier water to PSF & ACF
Required HP= 0.246 HP say 1 HP

SLUDGE HOLDING TANK & PUMPS


2 sludge Holding tank of Dimension (one for Alternative) =1.9 m X 1.9 m X 2m
Sludge Pump capacity=3cum/day

Let us consider Specific gravity of Sludge in bottom of tank =


Head considered is = 20 m
PUMP capacity in HP = 0,018518519
PUMP capacity in HP = 1
2 nos of Pump capacity in HP = 2