100% found this document useful (1 vote)
2K views8 pages

Error Code Sh-240

The document provides fault codes for troubleshooting Sumitomo excavators. It lists electrical fault codes from 7000-7199 related to pressure sensors, temperature sensors, angle sensors and solenoid valves. It also lists electrical fault codes from 7200-7399 related to solenoid valves and proportional valves. Finally, it lists mechanical fault codes from 7400-7599 related to high temperatures in the coolant, oil, and air systems. Each fault code is accompanied by conditions for display and troubleshooting guidance.

Uploaded by

Huấn Đặng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views8 pages

Error Code Sh-240

The document provides fault codes for troubleshooting Sumitomo excavators. It lists electrical fault codes from 7000-7199 related to pressure sensors, temperature sensors, angle sensors and solenoid valves. It also lists electrical fault codes from 7200-7399 related to solenoid valves and proportional valves. Finally, it lists mechanical fault codes from 7400-7599 related to high temperatures in the coolant, oil, and air systems. Each fault code is accompanied by conditions for display and troubleshooting guidance.

Uploaded by

Huấn Đặng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 8

Excavator Sumitomo Failure code(kode error).

Keyword: SH 200,SH 210-5,SH 210-6


troubleshoting,kode error,low power. Troubleshooting Sumitomo excavator fault
code/error kode sebagai berikut:

7000 – P1 pressure sensor

7001 – P2 pressure sensor

7002 – N1 pressure sensor

7003 - N2– pressure sensor

7004– wear overload pressure sensor

7005– bottom pressure sensor wear

7006– rod pressure sensor

7020 — wear upper pressure sensor

7021 — rotary pressure sensor wear

Walking through the pressure sensor 7022–

7023– wear arm pressure sensor

7040– fuel level sensor

7041 — oil temperature sensor

7045– monitor thermistor

7060 — boom angle sensor

7061– arm angle sensor

7062– deviation angle sensor

7063 — back to the oil filter blockage pressure switch

7200– swing brake solenoid valve

7201– walking speed solenoid valve

7202 — boost solenoid valve


7203 — BZ walking alarm

7204– saving solenoid valve

7205 – REL charge pump stops

7206 — spare circuit return valve

7207– slewing brake release valve

7208 fan reverse solenoid valve

7209– air conditioning temperature signal output

7210 — Crane

7211– turning signals and bucket stop

7212– safety lock solenoid valve

7240 — pump output proportional valve

7241– pump flow proportional valve

7242 —- Fan proportional valve

7243 — big arm proportional valve

7244 — arm proportional valve

7245– deviation proportional valve

7400.7402.7403– temperature

7404– oil

7405.7406– Dorian backward pressure temperature

7420 — generator voltage

7421– level

7422– oil pressure

7423 — air filter

7424– back to the oil filter


7600 — CAN

7601– monitor communications

7602 — ECM communication

7603– Controller B Communications

7604– Controller S Communications

7605 — ECM

7606 — EEPROM

0087 — no pumping pressure

0088– rail pressure anomaly

0089– pumping high pressure

0090 — SCV drive system

0107 atmospheric pressure sensor (voltage at the end)

0108 atmospheric pressure sensor (high voltage)

0112 supercharged forward air temperature anomalies (voltage at the end)

0113 — booster forward air temperature anomalies (high voltage)

0117.0118 water temperature is too low or high

0182.0183 — fuel temperature

0192– rail pressure (low voltage)

0193– rail pressure (high voltage)

0201 — 0206 glib driver circuit breaker (corresponding to each cylinder)

0219– limit operation

After 0237.0238– boost pressure sensor voltage low or high

0335.0336– crankshaft position sensor system

0340.0341 — cam position sensor


0380– preheat sensor

0487 — EGR sensor

Host fault code list

(A) an electrical fault (input) [7000-7199]

Fault location fault codes determine the timing of the failure mode occurred prerequisite
judgment recovery judgment

The conditions DTC display

P1 pressure sensor GND short / open 7000 ○ ignition switch is turned from no voltage ≦
0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V

Pressure sensor P2 GND short / open 7001 ○ ignition switch is turned from no voltage
≦ 0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V

N1 pressure sensor GND short / open 7002 ○ ignition switch is turned from no voltage ≦
0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V

N2 pressure sensor GND short / open 7003 ○ from the ignition switch is turned on
without voltage ≦ 0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V

Overload pressure sensor GND short / open 7004 ○ Select the applicable regional EU
voltage from the ignition switch is turned ≦ 0.25 V 0.25 V Supply short-circuit voltage ≧
4.75 V

Bottom pressure sensor GND short / open 7005 ○ choose a crane voltage ≦ 0.25 V
0.25 V Supply short-circuit voltage ≧ 4.75 V

Pressure sensor GND link short / open 7006 ○ choose a crane voltage ≦ 0.25 V 0.25 V
Supply short-circuit voltage ≧ 4.75 V

The upper part of the body’s pressure sensor GND short / open 7020 ○ ignition switch is
turned from no voltage ≦ 0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V

Rotary Pressure Sensor GND short / open 7021 ○ ignition switch is turned from no
voltage ≦ 0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V

Walking pressure sensor GND short / open 7022 ○ ignition switch is turned from no
voltage ≦ 0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V

Arm off pressure sensor GND short / open 7023 ○ from the ignition switch no voltage ≦
0.25 V 0.25 V Supply short-circuit voltage ≧ 4.75 V
Fuel oil level sensor open from 7040 ○ no resistance after the ignition is turned ≧ 100Ω

Short-circuit resistance ≦ 2 Ω

Oil temperature sensor open 7041 ○ 3 minutes after the engine is started without
resistance ≧ 67200Ω (voltage ≧ 4.93 V) 111Ω Short circuit from the ignition switch is
turned resistance ≦ 111Ω (voltage ≦ 0.5 V)

Monitor thermistor (* 1) Open 7045 × no receipt from the ignition switch is turned fault
bit is not received from the monitor from the monitor’s fault bit

Short circuit

Boom angle sensor GND short / open 7060 ○ choose a crane or anti-interference
voltage ≦ 0.2 V 0.2 V Short-circuit voltage ≧ 4.8 V power supply

Arm angle sensor GND short / open 7061 ○ choose a crane or anti-interference voltage
≦ 0.2 V 0.2 V Short-circuit voltage ≧ 4.8 V power supply

Deviation angle sensor GND short / open 7062 ○ choose a crane or anti-interference
voltage ≦ 0.2 V 0.2 V Short-circuit voltage ≧ 4.8 V power supply

Back to the oil filter clogging pressure switch open after 7063 ○ from the ignition switch
is turned to the front of the engine start without pressure switch off pressure switch open

Show “×” the project is not “abnormal electrical system” message. In addition, users no
longer DTC screen display. However, DTC recorded in the maintenance screen (DIAG)
in.

(2) electrical fault (output) [7200-7399]

Fault location fault codes determine the timing of the failure mode occurred prerequisite
judgment recovery judgment

The conditions DTC display

Rotary brake solenoid valve open from 7200 ○ no output after the ignition is turned ≠
Output Monitor Output = Output Monitor

Short circuit

Walking speed solenoid valve open from 7201 ○ no output after the ignition is turned ≠
Output Monitor Output = Output Monitor

Short circuit
7202 ○ boost solenoid valve open after the ignition is turned from no output ≠ Output
Monitor Output = Output Monitor

Short circuit

BZ walking alarm (* 1) Open 7203 × after turning the ignition switch from no output ≠
Output Monitor Output = Output Monitor

Short circuit

7204 ○ saving solenoid valve open after the ignition is turned from no output ≠ Output
Monitor Output = Output Monitor

Short circuit

REL Open 7205 ○ charge pump stops after the ignition is turned from no output ≠
Output Monitor Output = Output Monitor

Short circuit

Spare oil return circuit from the solenoid valve open 7206 ○ no output after the ignition
is turned ≠ Output Monitor Output = Output Monitor

Short circuit

Swing open from the solenoid valve open 7207 ○ no output after the ignition is turned ≠
Output Monitor Output = Output Monitor

Short circuit

Fans reverse solenoid valve open from 7208 ○ no output after the ignition is turned ≠
Output Monitor Output = Output Monitor

Short circuit

Air conditioning temperature signal output (* 1) Open 7209 × from the ignition switch is
turned on no output ≠ Output Monitor Output = Output Monitor

Short circuit

BZ cranes open after 7210 ○ no output from the ignition switch is turned ≠ Output
Monitor Output = Output Monitor

Short circuit
REL rotating lights and lock open 7211 ○ bucket from the ignition switch is turned on no
output ≠ Output Monitor Output = Output Monitor

Short circuit

Lock rod from the solenoid valve open 7212 ○ no output after the ignition is turned ≠
Output Monitor Output = Output Monitor

Short circuit

Pump output proportional valve open without current ≦ 30 mA 30 mA after 7240 ○


engine start Short-circuit current from the ignition switch is turned ≧ 3 A

Pump flow proportional valve open without current ≦ 30 mA 30 mA after 7241 ○ engine
start Short-circuit current from the ignition switch is turned ≧ 3 A

After the fan proportional valve open 7242 ○ engine start no current ≦ 30 mA 30 mA
Short-circuit current from the ignition switch is turned ≧ 3 A

After the big boom proportional valve open 7243 ○ engine start no current ≦ 30 mA 30
mA Short-circuit current from the ignition switch is turned ≧ 3 A

After the arm proportional valve open 7244 ○ engine start no current ≦ 30 mA 30 mA
Short-circuit current from the ignition switch is turned ≧ 3 A

Deviation proportional valve open after the engine starts 7245 ○ no current ≦ 30 mA 30
mA Short-circuit current from the ignition switch is turned ≧ 3 A

Show “×” the project is not “abnormal electrical system” message. In addition, users no
longer DTC screen display. However, DTC recorded in the maintenance screen (DIAG)
in.

(3) mechanical failure [7400-7599]

Fault location fault codes determine the timing of the failure mode occurred prerequisite
judgment recovery judgment

The conditions DTC display

Abnormally high temperature 1 7400 ○ one minute after starting the engine coolant
temperature sensor = normal CAN communication = normal ECM5 V supply voltage =
normal temperature ≧ 105 ℃ temperature <105 ℃

Unusually high temperatures 2 7402 ○ temperature ≧ 110 ℃ temperature <105 ℃

Abnormal high temperature 3 7403 ○ temperature ≧ 120 ℃ temperature <120 ℃


7404 ○ abnormal high temperature oil 1 minute after starting the engine oil temperature
sensor = normal oil temperature ≧ 95 ℃ temperature <95 ℃

Abnormally high temperature pressurized backward 1 7405 ○ supercharged engine start


one minute after the last-air temperature sensor = normal CAN communication = normal
ECM5 V supply voltage = normal pressurized air temperature ≧ 80 ℃ backward
backward pressurized air temperature ≦ 70 ℃

Unusually high temperatures 2 7406 ○ booster backward temperature ≧ 90 ℃


temperature pressurized backward <90 ℃

No abnormal voltage, low voltage AC motor 7420 ○ 10 seconds after starting the engine
pressure ≦ 10 V power generating pressure> 10 V

Coolant level is too low 7421 ○ no level switch is open level switch off the ignition switch
is turned from

Low engine oil pressure after 7422 ○ abnormal engine start 30 seconds oil pressure
sensor = normal CAN communication = normal ECM5 V supply voltage = normal
pressure ≦ 40 kPa pressure> 10 40 kPa

Air filter clogged 7423 ○ 10 seconds after starting the engine without vacuum switch on
the vacuum switch off

Back to the oil filter clogged 7424 ○ 10 seconds after starting the engine oil filter
pressure switch back to normal pressure switch off pressure switch open circuit.