0% found this document useful (0 votes)
1K views62 pages

Digi DS782 Setup Guide PDF

To add a PLU (Price Look Up code) on the DIGI DS782 scale: 1. Press the mode key twice, select a PLU number, and enter a price. 2. Press the mode key three times, select the preset key, enter the PLU number to confirm. 3. See the video at the provided URL for a demonstration. The document also provides details on various device settings that can be configured by entering specific spec numbers and values. Settings include auto power off, beeper volume, unit of measure, and serial communication protocols.

Uploaded by

elgego
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views62 pages

Digi DS782 Setup Guide PDF

To add a PLU (Price Look Up code) on the DIGI DS782 scale: 1. Press the mode key twice, select a PLU number, and enter a price. 2. Press the mode key three times, select the preset key, enter the PLU number to confirm. 3. See the video at the provided URL for a demonstration. The document also provides details on various device settings that can be configured by entering specific spec numbers and values. Settings include auto power off, beeper volume, unit of measure, and serial communication protocols.

Uploaded by

elgego
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 62

DIGI DS782 SETUP:

Add a PLU
Press the mode key twice
Select the a PLU number
Press enter
Type in a price
Press enter
Press the mode key three times
Select the preset key that you want to put the PLU on
Confirm by typing in the PLU number then enter

Please see here for a video demonstration of this:


www.youtube.com/watch?v=GMrRK46rZoo

Spec settings
Below is a list of variable settings that you can edit on the scale
To get into this mode hold the ‘Rezero’ key and type 141
Now type in the spec number (of what you want to change)
Press enter
Now type in the number relating to what setting you want
Press enter to save

SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0


0 Auto Power-off function

0100 0000 - Disable 0100 - 1 hour


0001 - 3 minute 0101 - 3 hours
0010 - 10 minutes 0110 ~ 1111 - Not used
0011 - 30 minutes
1 Buzzer Error alarm Weight sensitivity
0001
0 - On 0 - On 00 - Low 10 - High Middle
1 - Off 1 - Off 01 - Middle 11 - High
2 Tare override Unit price override Zero unit price
override
0000
0 - Allow 0 - Allow 0 - Allow
1 - Inhibit 1 - Inhibit 1 - Inhibit
3 Reserved Reserved
0000

4 Currency conversion operation method

0000 00 - Inhibit currency conversion operation


01 - Method 1
10 - Method 2
11 - Not used
5 Decimal point position on currency conversion rate

0000 000 - 7th digit (0.XXXXXX) 100 - 3rd digit (XXXX.XX)


001 - 6th digit (X.XXXXX) 101 - 2nd digit (XXXXX.X)
010 - 5th digit (XX.XXXX) 110 - No decimal point (XXXXXX)
011 - 4th digit (XXX.XXX) 111 - Not used

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 1 of 36


6 RTS/CTS handshaking Baud rate of RS-232C *RS type only
of RS-232C *RS type only
1011 000 - 1200 bps 100 - 19200 bps
0 - On 001 - 2400 bps 101 - 38400 bps
1 - Off 010 - 4800 bps 110 - Not used
011 - 9600 bps 111 - Not used
7 Stop bit of RS-232C Data length of RS- Parity of RS-232C *RS type only
*RS type only 232C *RS type only
0100
0 - 1 bit 0 - 7 bit 00 - None 10 - Even
1 - 2 bit 1 - 8 bit 01 - Odd 11 - Not used
8 Interval of time out error of RS-232C Transmission Additional parity code
*RS type only condition of RS-232C in text of RS-232C
*RS type only *RS type only
0110
00 - 1 second 10 - 5 second 0 - Weight stable 0 - No
01 - 3 second 11 - 10 second 1 - Unconditional 1 - Yes
9 Tare Weight in text of Unit Price in text of Total Price Weight in
RS-232C RS-232C text of RS-232C
1111 *RS type only *RS type only *RS type only
0 - No 0 - No 0 - No
1 - Yes 1 - Yes 1 - Yes

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 2 of 36


SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
10 Data transfer protocol of RS-232C *RS type only

0001 00000 - Inhibit data transfer


00001 - Type A (Standard stream)
00010 - Type W (Standard manual)
00011 - Type B (Standard command)
00100 - Type C (QUQA TRADING)
00101 - Type D (IBM, HUGIN)
00110 - Type E (ICL OLD)
00111 - Type F (ICL PORTUAGAL)
01000 - Type G (ICL ACTUAL)
01001 - Type H (CAS)
01010 - Type I (CAS PORTUAGAL)
01011 - Type J (NIXDORF)
01100 - Type K (NCR)
01101 - Type L (MONS)
01110 - Type M (Checkout-Dialog 02/04)
01111 - Type N (DATECS MP50/500)
10000 - Type O (NCI4000)
10001 - Type P (Checkout-Dialog 06)
10010 - Type Q (UNIWELL, ICL OLD OMRON)
10011 - Type R (ICL ACTUAL OMRON)
10100 - Type S (ICL CS500)
10101 - Type T (DTS)
10110 - Type U (SHARP UP-600/700, American Version)
10111 - Type V (NCI-ECR, Metrologic)
11000 - Type X (WTN) (sending key)
10111 ~ 11111 - Not used
11 Data transfer protocol
of RS-232C
0000
BIT4 of Data transfer
protocol of RS-232C
12 Calculate and check Key operation for tare Number of status bytes
validity of CS, KW in Pos-Weigh-Mode (for (for NCI-ECR only)
0000 (for Checkout-Dialog 06 only) Checkout-Dialog 02/04 and 06
only)

0 - No 0 - Allow 0 - 2 bytes
1 - Yes 1 - Inhibit 1 - 4 bytes
13 – 19
1111

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 3 of 36


For Weight & Measure - (1 4 2)
NOTE: It can work only when the SPAN Switch is on (Enable)

SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0


20 Version display when Selection of segment- Start range
power on check style
0000
0 - Allow 0 - Fast 00 - ±10% F.S. 10 - ±3% F.S.
1 - Inhibit 1 - Standard 01 - ±5% F.S. 11 - ±2% F.S.
21 Price Base Re-zero range

0000 00 - $ / kg 10 - $ / lb 00 - ±2% F.S. 10 - Not used


01 - $ / 100g 11 - $ / 1/4lb 01 - ±3% F.S. 11 - Not used
22 Decimal point position on weight display Decimal point position on unit and total price
display
1110
00 - No decimal point 00 - No decimal point for Unit & Total Price
01 - 2nd digit (0000.0) 01 - 2nd digit (0000.0) for Unit,
10 - 3rd digit (000.00) 2nd digit (00000.0) for Total Price
11 - 4th digit (00.000) 10 - 3rd digit (000.00) for Unit,
3rd digit (0000.00) for Total Price
11 - Not used
23 Minimum display Selection of resolution

15KG 0110 00 - 1 10 - 5 00 - 1/3000 10 - 1/7500


01 - 2 11 - 10 01 - 1/6000 11 - Not used
24 Weight single interval Net / Gross Negative weight display mask
or multi-interval Multi-interval
1100
0 - Single interval 0 - Gross 00 - Minus gross > 9e
1 - Multi-interval 1 - Net 01 - Minus gross weight
10 ~ 11 - Not used
25 Rounding for total price Re-zero function Fix function

0000 00 - Rounding 10 - Cut up 0 - Allow 0 - Allow


01 - Truncation 11 - Not used 1 - Inhibit 1 - Inhibit
26 Additional rounding for total price Additional rounding
for kati display
0001 000 - No additional rounding
001 - 1/4 rounding (25 step) 0 - Allow
010 - Special rounding (5 step) 1 - Inhibit
011 - 5 floor rounding (0-4 -> 0, 5-9 -> 5)
100 - Rounding for 1st digit
101 - Truncate 1st digit
110 - Cut up 1st digit
111 - Not used
27 Manual tare Tare subtraction Tare accumulation Auto tare clear when
cancellation rezero
0101
0 - Allow 0 - Allow 0 - Allow 0 - Allow
1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
28 Digital tare PLU tare / Preset tare Accumulation when Zero tracking when
tare tare
1111
0 - Allow 0 - Allow 0 - Allow 0 - Allow
1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 4 of 36


SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
29 Weight reset when tare Tare auto clear Unit price auto clear Price Base auto clear

1000 0 - Allow 0 - Allow 0 - Allow 0 - Allow (For UK)


1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
30 Auto clear condition Tax Change operation WT data
Method synchronization (+ key
0111 only)

0- >= Gross 21e 0 - Allow 0 - Indirect (method B) 0 - Allow


& >= Net 5e 1 - Inhibit 1 - Direct (method A) 1 - Inhibit
1 - >=Net 1e & price
not 0
31 Accumulation number Accumulation Price accumulation Price accumulation
display display style without removing without change weight
1011 weight (for >= ±10e)

0 - Allow 0 - Standard (“total”) 0 - Allow 0 - Allow


1 - Inhibit 1 - Japan (“Add”) 1 - Inhibit 1 - Inhibit
32 Exit from Exit from IR mode protected by Password setting
accumulation mode accumulation mode SPAN SW
1111 after 15 sec time out when weight change

0 - Allow 0 - Allow 0 - No 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Yes 1 - Inhibit
33 Non-weigh item Weight range of Non- Weight stability condition
accumulation weigh item
1001
0 - Allow 0 - Always 00 - Loose 10 - Tight
1 - Inhibit 1 - Net 0d 01 - Normal 11 - Stringent
34 Decimal point position on price display in Rounding for currency conversion
secondary currency
1000
00 - No decimal point for Unit & Total Price 00 - Rounding
01 - 2nd digit (0000.0) for Unit, 01 - Truncation
2nd digit (00000.0) for Total Price 10 - Cut up
10 - 3rd digit (000.00) for Unit, 11 - Not used
3rd digit (0000.00) for Total Price
11 - Not used
35 Exit from secondary Currency symbol for Indicator for Inverse currency
currency mode when secondary currency secondary currency conversion function
1111 weight change (for >
±2e)

0 - Allow 0 - No symbol 0 - Allow 0 - Allow


1 - Inhibit 1 - ‘EURO’ 1 - Inhibit 1 - Inhibit
36 Accumulation Subtraction Multiplication PLU function

1110 0 - Allow 0 - Allow 0 - Allow 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
37 Price Base change Currency conversion UNIT function
key(100g/kg, 1/4lb/lb) function
0100
0 - Allow (For UK) 0 - Allow 00 - Inhibit
1 - Inhibit 1 - Inhibit 01 - kg and lb conversion
10 - kg, decimal lb and kati conversion (for HK)
11 - Not used

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 5 of 36


SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
38 Change function Display hold Auto Zero function

1111 0 - Allow 0 - Allow 0 - Allow (for Japan)


1 - Inhibit 1 - Inhibit 1 - Inhibit
39 Weight range of data Permission of Weight Weight change or
output change or remove remove check of data
0001 *RS type only check for data output output
(for NCI-ECR only) *RS type only

0 - Always 0 - Allow 0 - Change


1 - Over 20e 1 - Inhibit 1 - Remove
40 Division for weight change check *RS type only

1000 0000 - 1e 1000 - 9e


0001 - 2e 1001 - 10e
0010 - 3e 1010 - 20e
0011 - 4e 1011 - 30e
0100 - 5e 1100 - 40e
0101 - 6e 1101 - 50e
0110 - 7e 1110 - 60e
0111 - 8e 1111 - 70e
41 – 47
1111

R&D Dept, SHANGHAI TERAOKA ELECTRONIC CO., LTD. 6 of 36


Features of DS781/782:

Bottom Front(Pole Type)

Side(Pole Type)

①:Power Interface
②:Backup battery
③:Operator displays
④:Keyboard
⑤:Platter
⑥:Nameplate
⑦:Customer displays(Pole Type)
1. General Layout
1.1. Bench Type
1.2. Pole Type

2. Features
* Low power consumption LCD digital price computing scale.(DS781)
Low power consumption LCD with back-light digital price computing scale.(DS782)
* Quick response to weight changes.
* Capacity : 3kg, 6kg, 15kg, 30kg, 6lb, 15lb, 30lb and 60lb.
* Resolution : Display Resolution 1/3000.
Internal Resolution 1/90000.
* Low power consumption :
- DS781: Battery(4 x C size dry battery) backup for more than 200 hours of continuous usage.
- DS781RS: Battery(4 x C size dry battery) backup for more than 120 hours of continuous usage.

- DS782: Rechargeable Battery backup for more than 600 hours of continuous usage. (Back-light function
is off)
- DS782RS: Rechargeable Battery backup for more than 380 hours of continuous usage. (Back-light
function is off).
* Two-Point battery low detect(DS781)
A. When battery is weak, the Battery indicator will light up.
B. When the power from battery becomes low such that the scale can not compute accurately,
all displays will shut off except the Battery indicator. The power is then shut off completely after 1minute.

* Intelligent power control(DS782)


A. When AC power is available, scale will use AC power only whatever rechargeable battery is installed or
not.
When AC power is shut off, scale will use battery automatically.
B. When scale works on rechargeable battery, if the battery is weak, the battery indictor will light up.
When the power from battery becomes low such that the scale can not compute accurately, all Displays
will shut off except the Battery indicator. The power is then shut off completely after 1 minute.
C. Scale detects rechargeable battery voltage and control battery charge process automatically.
The battery indicator blinks when rechargeable battery is being charged.
* Calibration by software.
* Water proof keyboard and splash proof housing.
* Customer and operator displays.
* 33 keys:
- ON/OFF key.
- 10 Numeric keys.
- 11/7 Operational keys.
- 11/15 Preset keys.
* High contrast LCD display.(DS781)
* High contrast LCD display with back-light function.(DS782)
* Flat platter.
* 99 codes(PLU) can be programmed with unit price and/or tare.
* RS-232C interface (DS781RS ,DS782RS only).

3. Operating Conditions
DS781:
* Power Source : 4 x C size dry battery or AC/DC Adapter(DC 5V ~ 8V, 100mA).
* Operating Temperature : -10℃ ~ +40℃.
* Operating Humidity : 15 ~ 85% RH.
* Power Consumption : 0.24W when DC 6V..
: 0.12W when using dry battery.

DS782:
* Power Source : AC 240/230/220V, 117/100V.
: DC 6V 5Ah rechargeable battery (optional).
* Operating Temperature : -10℃ ~ +40℃.
* Operating Humidity : 15 ~ 85% RH.
* Power Consumption : 18W when using AC power.
: 1.2W when using rechargeable battery.

4. Display and Indicators


Standard

4.1. Display Specifications


* Weight Display : 5 digits.
* Unit Price Display : 5 digits.
* Total Price Display : 6 digits.
4.2. Indicators
* : On when zero point is adjusted and weight is stable.
* NET : On when tare subtraction is performed.
* FIX : On when tare or PLU/unit price is fixed.
* MEM : On when price is accumulating.
* : On when battery is weak and needs to change.
5. Dimensions
* Platter size : 300 x 225 mm.
* Overall size : 335.7(W) x 349.7(D) x 123.5(H) (Excluding Pole type customer side display).
6. External Connectors
* DC receptacle.
* RS-232C interface (DS781RS only).
* RS-232C interface (DS782RS only).
7. Keysheet Layout

Type A

Type B
8. Key Functions

(The “mode”key is and the “RE-ZERO”key is in the keyboard)


8.1. Type A (11 Preset keys)
ON/OFF : ON/OFF key. Turns the power ON or OFF.

MODE : MODE SET key. Switch into following modes: Program Mode, Grand Total Check Mode.
RE-ZERO : RE-ZERO key. Resets weight display to zero.
T : TARE key. Set or clears tare value.
C : CLEAR key. Clears numerical values.
0 to 9 : Numeric keys. Input numerical value.
CODE : CODE key. Enter PLU code.
FIX : FIX key. To fix tare weight or PLU/unit price.
* : Data Setting key. Set up or clear mode.
Used as data send key for RS232C type.
+ : Accumulation key. Adds sum or accumulate sum.
- : Minus key. Correct operation on products.
x : Multiply key. Register the same non-weighing product multiple times.
AMT/TEND : Enters amount tendered. Two different types of AMT/TEND operation can be selected by
SPEC.
1 to 11 : PRESET keys. Set up or call either unit price.

8.2. Type B (15 Preset keys)


ON/OFF : ON/OFF key. Turns the power ON or OFF.

MODE : MODE SET key. Switch into following modes: Program Mode, Grand Total Check Mode.
RE-ZERO : RE-ZERO key. Resets weight display to zero.
T : TARE key. Set or clears tare value.
C : CLEAR key. Clears numerical values.
0 to 9 : Numeric keys. Input numerical value.
CODE : CODE key. Enter PLU code.
FIX : FIX key. To fix tare weight or PLU/unit price.
* : Data Setting key. Set up or clear mode.
1 to 15 : PRESET keys. Set up or call either unit price.

9. Specification Setting
9.1. Specification Enter (141)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[RE-ZERO] 88888 88888 888888 Enter 1 4 1 while depressing
[RE-ZERO] + [1] [4] [1] XXXX XXXX S P E C 0 RE-ZERO.
0
[+] XXXX XXXX S P E C 0 + key only increase Specification.
1
[-] XXXX XXXX S P E C 0 - key only decrease Specification.
0
[8] XXXX 0008 SPEC0 (00 ~ 19 is enabled)
0
[X] XXXX XXXX S P E C 0 Goes to a designed Specification count.
8
[0] [1] [0] [1] XXXX 0101 SPEC0 Only 1 & 0 are valid Specification data.
8
[*] XXXX XXXX S P E C 0 * key to update Specification, increase
9
[1] [1] [0] [0] XXXX 1100 SPEC0 Specification count.
9
[C] XXXX 0000 SPEC0 Clears entered data.
9
[-] 0101 0101 SPEC0 SPEC08 has been updated.
8
[T] 0.0 0 0 0.0 0 0.0 0 Store SPECS to EEPROM & escape to
Weighing mode.

9.2. Tax Setting


(Available when SPEC21.BIT2 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0.0 0 0.0 0 Weighing mode.
[RE-ZERO] 88888 88888 888888 Enter 9 9 9 while pressing
[RE-ZERO] + [9] [9] [9] tA 0.0 0 0.0 0 RE-ZERO.
[3] [0] [0] tA 0.0 0 3.0 0 Enter Tax Rate, e.g. 3.00%.
[RE-ZERO] rd45 3.0 0 0.0 0 RE-ZERO to store specification.
[C] CUtOF 3.0 0 0.0 0 Depress ‘C’ to select Cut Off
[C] rd45 3.0 0 0.0 0 Or Rounding.
[T] 0.0 0 0 0.0 0 0.0 0 Store Tax Rate to EEPROM & return to
Weighing mode.

9.3. Operational Specification List


For The Customer - (1 4 1)

SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0


0 Auto Power-off function
0000 - Disable 0100 - 1 hour
0001 - 3 minute 0101 - 3 hours
0010 - 10 minutes 0110 ~ 1111 - Not used
0011 - 30 minutes
1 Buzzer Error alarm Weight sensitivity

0 - On 0 - On 00 - Low 10 - High Middle


1 - Off 1 - Off 01 - Middle 11 - High
2 Tare override Unit price override Zero unit price
override

0 - Allow 0 - Allow 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Inhibit
3 Back-light function *DS-782 only Auto back-light interval *DS-782 only
(Effective only if SPEC01.32 set to 00)
00 - Auto 10 - Always off 00 - 6s 10 - Not used
01 - Always on 11 - Not used 01 - 15s 11 - Not used
4 Currency conversion operation method

00 - Inhibit currency conversion operation


01 - Method 1
10 - Method 2
11 - Not used
5 Decimal point position on currency conversion rate

000 - 7th digit (0.XXXXXX) 100 - 3rd digit (XXXX.XX)


001 - 6th digit (X.XXXXX) 101 - 2nd digit (XXXXX.X)
010 - 5th digit (XX.XXXX) 110 - No decimal point (XXXXXX)
011 - 4th digit (XXX.XXX) 111 - Not used
6 RTS/CTS Baud rate of RS-232C *RS type only
handshaking of
RS-232C *RS type only 000 - 1200 bps 100 - 19200 bps
001 - 2400 bps 101 - 38400 bps
0 - On 010 - 4800 bps 110 - Not used
1 - Off 011 - 9600 bps 111 - Not used
7 Stop bit of RS-232C Data length of Parity of RS-232C *RS type only
*RS type only RS-232C *RS type
only

0 - 1 bit 00 - None 10 - Even


1 - 2 bit 0 - 7 bit 01 - Odd 11 - Not used
1 - 8 bit
8 Interval of time out error of RS-232C Transmission Additional parity
*RS type only condition of code in text of
RS-232C RS-232C
*RS type only *RS type only

00 - 1 second 10 - 5 second
01 - 3 second 11 - 10 second 0 - Weight stable 0 - No
1 - Unconditional 1 - Yes
9 Tare Weight in text Unit Price in text of Total Price Weight in
of RS-232C RS-232C text of RS-232C
*RS type only *RS type only *RS type only

0 - No 0 - No 0 - No
1 - Yes 1 - Yes 1 - Yes
10 Data transfer protocol of RS-232C *RS type only

00000 - Inhibit data transfer


00001 - Type A (Standard stream)
00010 - Type W (Standard manual)
00011 - Type B (Standard command)
00100 - Type C (QUQA TRADING)
00101 - Type D (IBM, HUGIN)
00110 - Type E (ICL OLD)
00111 - Type F (ICL PORTUAGAL)
01000 - Type G (ICL ACTUAL)
01001 - Type H (CAS)
01010 - Type I (CAS PORTUAGAL)
01011 - Type J (NIXDORF)
01100 - Type K (NCR)
01101 - Type L (MONS)
01110 - Type M (Checkout-Dialog 02/04)
01111 - Type N (DATECS MP50/500)
10000 - Type O (NCI4000)
10001 - Type P (Checkout-Dialog 06)
10010 - Type Q (UNIWELL, ICL OLD OMRON)
10011 - Type R (ICL ACTUAL OMRON)
10100 - Type S (ICL CS500)
10101 - Type T (DTS)
10110 - Type U (SHARP UP-600/700, American Version)
10111 - Type V (NCI-ECR, Metrologic)
11000 - Type X (WTN) (sending key)
10111 ~ 11111 - Not used
11 Data transfer
protocol of RS-232C

BIT4 of Data transfer


protocol of RS-232C
12 Calculate and check Key operation for Number of status
validity of CS, KW tare in bytes (for NCI-ECR only)
(for Checkout-Dialog 06 Pos-Weigh-Mode (for
only) Checkout-Dialog 02/04 and
06 only)

0 - 2 bytes
0 - No 0 - Allow 1 - 4 bytes
1 - Yes 1 - Inhibit
13 - 19
10. Operations In Weighing Mode
10.1. ON/OFF
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[ON/OFF] 8.8.8.8.8. 8.8.8.8.8. 8.8.8.8.8.8 Display for 1 seconds. *Note1
.
Blank for 1 seconds.
8.8.8.8.8. 8.8.8.8.8. 8.8.8.8.8.8 Display for 1 seconds.
.
Blank for 1 seconds.
88888 88888 888888
Ready to operate 0.0 0 0 0.0 0 0.0 0 Weighing mode.
[ON/OFF] OFF.
* Note1: Power On Segment Check Style can be selected by setting SPEC20.2. In this example assume SPEC20.2 = 0.

10.2. Tare Subtraction


10.2.1. One Touch Tare Subtraction
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 3 0 0.0 0 0.0 0 Put tare (e.g 30 g) on platter.
[T] 0.0 0 0 0.0 0 0.0 0 Subtract the tare weight.
Remove the tare weight - 0.0 3 0 0.0 0 0.0 0
[T] 0.0 0 0 0.0 0 0.0 0 Clear the tare weight.

10.2.2. Digital Tare Subtraction


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[5] 0.0 0 0 0.0 5 0.0 0 Key in the tare weight (e.g 5g).
[T] - 0.0 0 5 0.0 0 0.0 0 Subtract the tare weight (Assume 15kg).
[T] 0.0 0 0 0.0 0 0.0 0 Clear the tare weight.

10.3. Plural Operation


10.3.1. Standard Version
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [0] [0] [0] 0.0 0 0 1 0.0 0 0.0 0 Enter unit price.
Put product on platter. 0.5 0 0 1 0.0 0 5.0 0
[+] tOtAL 1 5.0 0 Accumulation the data.
Remove product from platter. tOtAL 1 5.0 0
[1] [5] [0] [0] 0.0 0 0 1 5.0 0 0.0 0 Enter unit price.
[+] tOtAL 2 2 0.0 0 Fixed price accumulation.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[+] tOtAL 2 2 0.0 0 Enter accumulation mode.
[+] tOtAL 2 2 0.0 0 Nothing happen.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing
mode.
10.3.2. Japan Type A Version
(When SPEC31.2 = 1 and SPEC31.3 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [0] [0] [0] 0.0 0 0 1 0.0 0 0.0 0 Enter unit price.
Put product on platter. 0.5 0 0 1 0.0 0 5.0 0
[+] Add 1] 5.1 5 Accumulation the data(assume tax rate =
3%).
Remove product from platter. Add 1] 5.1 5
[1] [5] [0] [0] 0.0 0 0 1 5.0 0 0.0 0 Enter unit price.
[+] Add 2] 2 0.6 0 Fixed price accumulation.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing
mode.

10.3.3. Japan Type B Version


(When SPEC31.2 = 1 and SPEC31.3 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [0] [0] [0] 0.0 0 0 1 0.0 0 0.0 0 Enter unit price.
Put product on platter. 0.5 0 0 1 0.0 0 5.0 0
[+] Add 5.0 0 5.1 5 Accumulation the data (tax rate = 3%).
Remove product from platter. Add 5.0 0 5.1 5
[1] [5] [0] [0] 0.0 0 0 1 5.0 0 0.0 0 Enter unit price.
[+] Add 2 0.0 0 2 0.6 0 Fixed price accumulation.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing
mode.

10.4. Multiplication Operation


10.4.1. Standard Version
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
0.4 1 2 1 2.3 4 5.0 8 Put product on platter.
[+] tOtAL 1 5.0 8 Accumulation the data.
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[x] PCS 5.0 0 0.0 0 Depress multiply key.
0
[2] [0] PCS 2 5.0 0 1 0 0.0 0 multiply the data by 20.
0
[+] tOtAL 21 1 0 5.0 8 Accumulation the data.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing
mode.

10.4.2. Japan Type A Version


(When SPEC31.2 = 1 and SPEC31.3 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
0.4 1 2 1 2.3 4 5.0 8 Put product on platter.
[+] Add 1] 5.2 3 Accumulation the data (assume tax rate =
3%)
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[x] 0] 5.0 0 0.0 0 Depress multiply key.
[2] [0] 20] 5.0 0 1 0 0.0 0 multiply the data by 20.
[+] Add 2 1] 1 0 8.2 3 Accumulation the data.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing
mode.

10.4.3. Japan Type B Version


(When SPEC31.2 = 1 and SPEC31.3 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
0.4 1 2 1 2.3 4 5.0 8 Put product on platter
[+] Add 5.0 8 5.2 3 Accumulation the data (assume tax rate =
3%)
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[x] 0] 5.0 0 0.0 0 Depress multiply key
[2] [0] 20] 5.0 0 1 0 0.0 0 multiply the data by 20
[+] Add 1 0 5.0 8 1 0 8.2 3 Accumulation the data
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing
mode.

10.5. AMT/TEND Key Operation


10.5.1. Method A (Direct entry method: SPEC30.1 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [5] [0] 0.0 0 0 1 2.5 0 0.0 0 Enter unit price.
Put product on platter. 0.4 2 0 1 2.5 0 5.2 5
[+] tOtAL 1 5.2 5 Accumulation the data.
Remove product from platter. tOtAL 1 5.2 5
[6] [0] [0] 0.0 0 0 6.0 0 0.0 0 Enter the amount tendered.
[AMT/TEND] CHG 0.7 5 Compute change & clear current total.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[+] tOtAL 0 0.0 0 Check total data.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

10.5.2. Method B (Indirect entry method: SPEC30.1 = 0)


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [5] [0] 0.0 0 0 1 2.5 0 0.0 0 Enter unit price.
Put product on platter. 0.4 2 0 1 2.5 0 5.2 5
[+] tOtAL 1 5.2 5 Accumulation the data.
Remove product from platter. tOtAL 1 5.2 5
[AMT/TEND] tnd 5.2 5 Prepare to compute change.
[6] [0] [0] tnd 6.0 0 Enter the amount tendered.
[*] CHG 0.7 5 Compute change & clear current total.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[+] tOtAL 0 0.0 0 Check total data.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

10.6. Correction Of Past Sales Data


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
Put product on platter. 2.0 0 0 1 2.3 4 2 4.6 8
[+] tOtAL 1 2 4.6 8 Accumulation the data.
Remove product from platter. tOtAL 1 2 4.6 8
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[+] tOtAL 2 2 9.6 8 Accumulation the data .
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
Put product on platter. 2.0 0 0 1 2.3 4 2 4.68
[-] Corr 1 5.0 0 Perform past sale data correction.
[C] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

10.7. Price Base Change By 100g/kg Key


(Available when SPEC37.3 = 0)
1 - ZERO 2 - NET 3 - kg 4 - 100g 5 - MEMORY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
[1] [0] [0] 0.0 0 0 1.0 0 0.0 0 Key in unit price.
[100g/kg] 0.0 0 0 1.0 0 0.0 0 Change price base to $/100g.
Put product on platter. 1.0 0 0 1.0 0 1 0.0 0
[C] 1.0 0 0 0.0 0 0.0 0 C key clear unit price and price base.
[100g/kg] 1.0 0 0 0.0 0 0.0 0 Change price base to $/100g.
[2] [0] [0] 1.0 0 0 2.0 0 2 0.0 0 Key in unit price.
[100g/kg] 1.0 0 0 2.0 0 2.0 0 Change price base to $/kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0

10.8. Auto Zero Operation


(Available when SPEC38.1 = 0)
1 - ZERO 2 - NET 3 – AUTOZERO 4 - MEMORY 5 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
0.0 0 0 0.0 0 0.0 0 Weighing mode.
Put 5g on platter. 0.0 0 5 0.0 0 0.0 0 Auto Zero function is ineffective.
[AUTO ZERO] 0.0 0 0 0.0 0 0.0 0 Auto Zero function is effective.
Add 20g on platter. 0.0 2 5 0.0 0 0.0 0 Exceed Auto Zero range (<5e).
Remove 20g from platter. 0.0 0 0 0.0 0 0.0 0
[AUTO ZERO] 0.0 0 5 0.0 0 0.0 0 Auto Zero function is cancelled.

10.9. kg and lb conversion by UNIT Key


(Available when SPEC37.10 = 01)
1 - ZERO 2 - NET 3 - $/kg 4 - $/lb 5 - MEMORY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0 Weight in kg.
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price in $/kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0
[UNIT] 0.0 0 0 0.0 0 0.0 0 Change to lb.
Put product on platter. 1.1 0 0 0.0 0 0.0 0 Weight in lb.
[2] [0] [0] 1.1 0 0 2.0 0 2.2 0 Key in unit price in $/lb.
[UNIT] 0.5 0 0 2.0 0 1.0 0 Change to kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0

10.10. kg, decimal lb and kati conversion by UNIT Key


(Available when SPEC37.10 = 10)
1 - ZERO 2 - NET 3 - $/lb 4 - $/kati 5 - MEMORY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0 Weight in kg.
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price in $/kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0
[UNIT] 0. 0.0 0.0 0 0.0 0 Change to decimal lb.
Put product on platter. 1. 1.6 0.0 0 0.0 0 Weight in decimal lb.
[2] [0] [0] 1. 1.6 2.0 0 2.2 0 Key in unit price in $/lb.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0
[UNIT] 0. 0.0 0.0 0 0.0 0 Change to kati.
Put product on platter. 0.1 3.2 0.0 0 0.0 0 Weight in kati.
[2] [0] [0] 0.1 3.2 2.0 0 1.6 5 Key in unit price in $/kati.
[UNIT] 0.5 0 0 2.0 0 1.0 0 Change to kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0

10.11. Currency Conversion by EURO Key


(Available when SPEC37.2 = 0)
10.11.1. Currency Conversion Operation Method 1 (SPEC4.32 = 01)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price.
[EURO] EURO 2.2 0 Display re-calculated total price in
secondary currency. Assume SPEC26.3 =
1, conversion rate is 2.20.
[EURO] 0.5 0 0 2.0 0 1.0 0 Return to Weighing Mode.

18.11.2. Currency Conversion Operation Method 2 (SPEC4.32 = 10)


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price.
[EURO] EURO 4.4 0 2.2 0 Display re-calculated unit price & total
price in secondary currency. Assume
SPEC26.3 = 1, conversion rate is 2.20.
[EURO] 0.5 0 0 2.0 0 1.0 0 Return to Weighing Mode.

11. Operations of Mode Set Key


11.1. Mode Change Using Mode Set Key
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2kg on the platter 2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE Depress [M] key twice within 3 seconds,
enter PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

11.2. PLU Setting


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[1] [0] PLU 10 CodE Enter plu code. *Note1
[*] PLU 0.0 0 UP Display current unit price in PLU.
[1] [5] [0] PLU 1.5 0 UP Enter unit price.
[*] PLU 0.0 0 0 tArE Display current tare in PLU. *Note2
[1] [0] [0] PLU 0.1 0 0 tArE Enter tare. *Note2
[*] PLU 0 CodE Store PLU.
[M] [M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[1] [0] [CODE] 1.9 0 0 1.5 0 2.8 5 Call up PLU.
[C] 2.0 0 0 0.0 0 0.0 0 Clear PLU.
*Note1: Valid code number is 1 - 99.
*Note2: When PLU tare is allowed by SPEC28.2 = 0.

11.3. Preset Key Setting


11.3.1. Preset Key Setting when PLU function is allowed.
(When SPEC36.0 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[PRESET 1] P.S E t P L U 2 0 Display current PLU code in PRESET.
[C] P.S E t 0 Clear PRESET.
[1] [0] P.S E t 10 Enter PLU code.
[*] P.S E t Store PRESET.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[PRESET 1] 1.9 0 0 1.5 0 2.8 5 Call up PLU set in PRESET 1.
[C] 2.0 0 0 0.0 0 0.0 0 Clear PLU.
11.3.2. Preset Key Setting when PLU function is inhibited.
(When SPEC36.0 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] P.S E t 0.0 0 Preset key setting mode.
[1] [5] [0] P.S E t 1.5 0 Enter unit price.
[PRESET 1] P.S E t 0.0 0 Store unit price to PRESET1.
[T] P.S E t 0.0 0 0 tArE Change to set tare mode. *Note1
[1] [0] [0] P.S E t 0.1 0 0 tArE Enter tare. *Note1
[PRESET 2] P.S E t 0.0 0 Store tare to PRESET2. *Note1
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[PRESET 2] 1.9 0 0 0.0 0 0.0 0 Call up tare set in PRESET 2.
[PRESET 1] 1.9 0 0 1.5 0 2.8 5 Call up unit price set in PRESET 1.
[C] 1.9 0 0 0.0 0 0.0 0 Clear unit price.
Remove product from platter - 0.1 0 0 0.0 0 0.0 0
[T] 0.0 0 0 0.0 0 0.0 0 Clear tare.
*Note1: When Preset tare is allowed by SPEC28.2 = 0.

11.4. Conversion Rate Setting


(Available when SPEC37.2 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] EURO rAtE 0 Enter into conversion rate setting mode.
[2] [2] [0] EURO rAtE 2. 2 0 Set conversion rate to 2.20.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

11.5. Invert Currency Conversion Function


(Available when SPEC37.2 = 0 and SPEC35.0 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] EURO RAtE 0 Enter into conversion rate setting mode.
[RE-ZERO] 88888 88888 888888 Enter 2 0 0 1 while pressing RE-ZERO.
[RE-ZERO] + [2] [0] [0] [1] EURO InvErt EURO conversion function is inverted.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
*Note: When Invert Currency Conversion Function operation is performed, following change will be made internally:
1) The data set in SPEC22.10 and SPEC34.32 is exchanged.
2) Set SPEC35.2 = 0; SPEC35.1 = 0; SPEC35.0 = 1.
11.6. Cancel Currency Conversion Function
(Available when SPEC37.2 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] EURO RA t E 0 Enter into conversion rate setting mode.
[RE-ZERO] 88888 88888 888888 Enter 2 0 0 2 while pressing RE-ZERO.
[RE-ZERO] + [2] [0] [0] [2] EURO CAnCEL EURO conversion function is cancelled.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
*Note: When Cancel Currency Conversion Function operation is performed, SPEC37.2 is set to 1 internally:

12. Error Massage List


The following error message will appear when an incorrect operation is performed.
Message Remarks Appropriate Operation
888888 When scale is not steady when power on. Place scale on firm, flat base.
OF When weight exceeds capacity+9d, or something is on Remove the item on the platter.
the platter when power on.
UF When negative weight exceeds display limit. REZERO or ON/OFF again.
TotAl When current Total overflow. Clear current Total.
FULL
Error When error occurs in maintenance mode. Repeat operation.
E R R 01 When A/D error. Contact dealer.
E R R 02 When data flash erase error. Contact dealer.
E R R 03 When data flash program error. Contact dealer.
Service Manual for DS-781/782(RS)

Edition Month Year


1st Sep. 2008
2nd
3rd
4th
5th

SHANGHAI TERAOKA ELECTRONIC CO., LTD.


Ting Lin Industrial Development Zone, Jin Shan District, Shanghai P. R. China 201505
Tel: +86-21-5723-4888 Fax: +86-21-5723-4090 Web: www.digi-scale.com
Contents
1. General Layout ................................................................................................................................................................................................ 5
1.1. Bench Type ......................................................................................................................................................................................... 5
1.2. Pole Type ............................................................................................................................................................................................ 6
2. Purpose ............................................................................................................................................................................................................ 7
3. Features ........................................................................................................................................................................................................... 7
4. Operating Conditions....................................................................................................................................................................................... 8
5. Analog Specification ....................................................................................................................................................................................... 8
6. Capacity/Minimum Graduation/Tare range ..................................................................................................................................................... 8
6.1. Single Interval ..................................................................................................................................................................................... 8
6.2. Multi-Interval ...................................................................................................................................................................................... 8
7. Display and Indicators ..................................................................................................................................................................................... 9
7.1. Display Specifications ......................................................................................................................................................................... 9
7.2. Indicators ............................................................................................................................................................................................ 9
8. Dimensions ...................................................................................................................................................................................................... 9
9. External Connectors ........................................................................................................................................................................................ 9
10. Main Components ......................................................................................................................................................................................... 9
11. Existing parts to be used ................................................................................................................................................................................ 9
12. Keysheet Layout ............................................................................................................................................................................................ 9
13. Key Functions.............................................................................................................................................................................................. 10
13.1. Type A (11 Preset keys) .................................................................................................................................................................. 10
13.2. Type B (15 Preset keys) .................................................................................................................................................................. 10
14. Block Diagram of Electrical Connection ..................................................................................................................................................... 11
15. Physical layout of Electrical Connection ..................................................................................................................................................... 13
16. Hardware Description .................................................................................................................................................................................. 14
16.1. Microcomputer ................................................................................................................................................................................ 14
16.2. Pin Assignment ............................................................................................................................................................................... 15
17. Maintenance Mode ..................................................................................................................................................................................... 16
17.1. SPAN Switch and Software Version Check ................................................................................................................................... 16
17.2. SPAN Adjustment ........................................................................................................................................................................... 16
17.2.1. Full capacity weight for SPAN Adjustment ....................................................................................................................... 16
17.2.2. Proportion of capacity weight for SPAN Adjustment ........................................................................................................ 17
17.3. Escape from Maintenance mode .................................................................................................................................................... 17
17.4. Specification Setting ....................................................................................................................................................................... 18
17.4.1. Specification Enter (141) ................................................................................................................................................... 18
17.4.2. Specification Enter (142) ................................................................................................................................................... 18
17.5. Internal Count & A/D Count Display ............................................................................................................................................ 19
17.6. Tax Setting ...................................................................................................................................................................................... 19
17.7. Operational Specification List ......................................................................................................................................................... 19
18. Operations In Weighing Mode ................................................................................................................................................................... 25
18.1. ON/OFF.......................................................................................................................................................................................... 25
18.2. Tare Subtraction ............................................................................................................................................................................. 25
18.2.1. One Touch Tare Subtraction ............................................................................................................................................. 25
18.2.2. Digital Tare Subtraction .................................................................................................................................................... 25
18.3. Plural Operation ............................................................................................................................................................................. 26
18.3.1. Standard Version ................................................................................................................................................................ 26
18.3.2. Japan Type A Version ........................................................................................................................................................ 26
18.3.3. Japan Type B Version ........................................................................................................................................................ 26
18.4. Multiplication Operation ................................................................................................................................................................ 27
18.4.1. Standard Version ................................................................................................................................................................ 27
18.4.2. Japan Type A Version ........................................................................................................................................................ 27
18.4.3. Japan Type B Version ........................................................................................................................................................ 27
18.5. AMT/TEND Key Operation............................................................................................................................................................ 28
18.5.1. Method A (Direct entry method: SPEC30.1 = 1) ............................................................................................................... 28
18.5.2. Method B (Indirect entry method: SPEC30.1 = 0) ............................................................................................................ 28
18.6. Correction Of Past Sales Data ....................................................................................................................................................... 28
18.7. Price Base Change By 100g/kg Key ............................................................................................................................................... 29
18.8. Auto Zero Operation....................................................................................................................................................................... 29
18.9. kg and lb conversion by UNIT Key ................................................................................................................................................ 29
18.10. kg, decimal lb and kati conversion by UNIT Key ........................................................................................................................ 30
18.11. Currency Conversion by EURO Key ............................................................................................................................................ 30
18.11.1. Currency Conversion Operation Method 1 (SPEC4.32 = 01) ......................................................................................... 30
18.11.2. Currency Conversion Operation Method 2 (SPEC4.32 = 10) ......................................................................................... 30
19. Operations of Mode Set Key ....................................................................................................................................................................... 31
19.1. Mode Change Using Mode Set Key................................................................................................................................................ 31
19.2. PLU Setting .................................................................................................................................................................................... 31
19.3. Preset Key Setting ........................................................................................................................................................................... 31
19.3.1. Preset Key Setting when PLU function is allowed. ........................................................................................................... 31
19.3.2. Preset Key Setting when PLU function is inhibited. ......................................................................................................... 32
19.4. Conversion Rate Setting ................................................................................................................................................................. 32
19.5. Invert Currency Conversion Function........................................................................................................................................... 32
19.6. Cancel Currency Conversion Function ......................................................................................................................................... 33
20. RS-232C Interface ....................................................................................................................................................................................... 33
20.1. Specification .................................................................................................................................................................................... 33
20.2. Pin Assignment ............................................................................................................................................................................... 33
20.3. Control Code and Characters ........................................................................................................................................................... 33
20.4. Data Format ..................................................................................................................................................................................... 35
20.5 Communication Method ................................................................................................................................................................... 36
20.5.1 Type A (Standard Stream).................................................................................................................................................... 37
20.5.2 Type W (Standard Manual) .................................................................................................................................................. 38
20.5.3 Type B (Standard Command)............................................................................................................................................... 39
21. Error Massage List ...................................................................................................................................................................................... 39
Features of DS781/782:

Bottom Front(Pole Type)

Side(Pole Type)

①:Power Interface
②:Backup battery
③:Operator displays
④:Keyboard
⑤:Platter
⑥:Nameplate
⑦:Customer displays(Pole Type)
1. General Layout
1.1. Bench Type
1.2. Pole Type
2. Purpose
To develop a low power consumption digital price computing scale which caters OIML Standard.

3. Features
* Low power consumption LCD digital price computing scale.(DS781)
Low power consumption LCD with back-light digital price computing scale.(DS782)
* Quick response to weight changes.
* Capacity : 3kg, 6kg, 15kg, 30kg, 6lb, 15lb, 30lb and 60lb.
* Resolution : Display Resolution 1/3000.
Internal Resolution 1/90000.
* Low power consumption :
- DS781: Battery(4 x C size dry battery) backup for more than 200 hours of continuous usage.
- DS781RS: Battery(4 x C size dry battery) backup for more than 120 hours of continuous usage.

- DS782: Rechargeable Battery backup for more than 600 hours of continuous usage. (Back-light function is off)
- DS782RS: Rechargeable Battery backup for more than 380 hours of continuous usage. (Back-light function is off).

* Two-Point battery low detect(DS781)


A. When battery is weak, the Battery indicator will light up.
B. When the power from battery becomes low such that the scale can not compute accurately,
all displays will shut off except the Battery indicator. The power is then shut off completely after 1minute.

* Intelligent power control(DS782)


A. When AC power is available, scale will use AC power only whatever rechargeable battery is installed or not.
When AC power is shut off, scale will use battery automatically.
B. When scale works on rechargeable battery, if the battery is weak, the battery indictor will light up.
When the power from battery becomes low such that the scale can not compute accurately, all Displays
will shut off except the Battery indicator. The power is then shut off completely after 1 minute.
C. Scale detects rechargeable battery voltage and control battery charge process automatically.
The battery indicator blinks when rechargeable battery is being charged.
* Calibration by software.
* Water proof keyboard and splash proof housing.
* Customer and operator displays.
* 33 keys:
- ON/OFF key.
- 10 Numeric keys.
- 11/7 Operational keys.
- 11/15 Preset keys.
* High contrast LCD display.(DS781)
* High contrast LCD display with back-light function.(DS782)
* Flat platter.
* 99 codes(PLU) can be programmed with unit price and/or tare.
* RS-232C interface (DS781RS ,DS782RS only).
4. Operating Conditions
DS781:
* Power Source : 4 x C size dry battery or AC/DC Adapter(DC 5V ~ 8V, 100mA).
* Operating Temperature : -10℃ ~ +40℃.
* Operating Humidity : 15 ~ 85% RH.
* Power Consumption : 0.24W when DC 6V..
: 0.12W when using dry battery.

DS782:
* Power Source : AC 240/230/220V, 117/100V.
: DC 6V 5Ah rechargeable battery (optional).
* Operating Temperature : -10℃ ~ +40℃.
* Operating Humidity : 15 ~ 85% RH.
* Power Consumption : 18W when using AC power.
: 1.2W when using rechargeable battery.
5. Analog Specification
* Input sensitivity : 1mV/V.
* Zero adjust range : 0 ± 3.3mV.
* Zero balance range : 0 ± 0.33mV.
* L/C applied voltage : DC 3.3V.
* Speed of A/D conversion : 10 times/sec.
* Internal Resolution : 90000.
6. Capacity/Minimum Graduation/Tare range
6.1. Single Interval
Capacity Minimum Graduation Tare Rang
3kg 1g (1e = 30IR) 0 - 1.499kg
6kg 2g (1e = 30IR) 0 - 2.998kg
15kg 5g (1e = 30IR) 0 - 7.495kg
30kg 10g (1e = 30IR) 0 - 14.99kg
6lb 0.002lb (1e = 30IR) 0 - 2.998lb
15lb 0.005lb (1e = 30IR) 0 - 7.495lb
30lb 0.01lb (1e = 30IR) 0 - 14.99lb
60lb 0.02lb (1e = 30IR) 0 - 29.98lb

6.2. Multi-Interval
Capacity Minimum Graduation Tare Rang
3kg 1g (1e = 10IR) 0 - 1.499kg
6kg (0-3kg)-1g (1e=15IR) (3-6kg)-2g (1e=30IR) 0 - 2.999kg
15kg (0-6kg)-2g (1e=12IR) (6-15kg)-5g (1e=30IR) 0 - 5.998kg
30kg (0-15kg)-5g (1e=15IR) (15-30kg)-10g (1e=30IR) 0 - 9.995kg
6lb (0-3lb)-0.001lb (1e=15IR) (3-6lb)-0.002lb (1e=30IR) 0 - 2.999lb
15lb (0-6lb)-0.002lb (1e=12IR) (6-15lb)-0.005lb (1e=30IR) 0 - 5.998lb
30lb (0-15lb)-0.005lb (1e=15IR) (15-30lb)-0.01lb (1e=30IR) 0 - 9.995lb
60lb (0-30lb)-0.01lb (1e=15IR) (15-30lb)-0.02lb (1e=30IR) 0 - 29.99lb
*NOTE : IR -> Internal Resolution, e -> Division(Minimum Increment).
Internal count(full capacity) = 90000IR.
7. Display and Indicators

Standard

7.1. Display Specifications


* Weight Display : 5 digits.
* Unit Price Display : 5 digits.
* Total Price Display : 6 digits.
7.2. Indicators
* : On when zero point is adjusted and weight is stable.
* NET : On when tare subtraction is performed.
* FIX : On when tare or PLU/unit price is fixed.
* MEM : On when price is accumulating.
* : On when battery is weak and needs to change.
8. Dimensions
* Platter size : 300 x 225 mm.
* Overall size : 335.7(W) x 349.7(D) x 123.5(H) (Excluding Pole type customer side display).
9. External Connectors
* DC receptacle.
* RS-232C interface (DS781RS only).
* RS-232C interface (DS782RS only).
10. Main Components
* Microcomputer : R5F21255(16 bit, 24K ROM) / R5F21256(16 bit, 32K ROM) / R5F21257(16 bit, 48K ROM)
/ R5F21258(16 bit, 64K ROM).
* Display device : LCD.
* Loadcell : 1k resistance loadcell.
11. Existing parts to be used
* Platter (DS-685).
* J type Loadcell (DS-671).
12. Keysheet Layout

Type A
Type B
13. Key Functions

(The “mode”key is and the “RE-ZERO”key is in the keyboard)


13.1. Type A (11 Preset keys)
ON/OFF : ON/OFF key. Turns the power ON or OFF.
MODE : MODE SET key. Switch into following modes: Program Mode, Grand Total Check Mode.
RE-ZERO : RE-ZERO key. Resets weight display to zero.
T : TARE key. Set or clears tare value.
C : CLEAR key. Clears numerical values.
0 to 9 : Numeric keys. Input numerical value.
CODE : CODE key. Enter PLU code.
FIX : FIX key. To fix tare weight or PLU/unit price.
* : Data Setting key. Set up or clear mode.
Used as data send key for RS232C type.
+ : Accumulation key. Adds sum or accumulate sum.
- : Minus key. Correct operation on products.
x : Multiply key. Register the same non-weighing product multiple times.
AMT/TEND : Enters amount tendered. Two different types of AMT/TEND operation can be selected by SPEC.
1 to 11 : PRESET keys. Set up or call either unit price.

13.2. Type B (15 Preset keys)


ON/OFF : ON/OFF key. Turns the power ON or OFF.
MODE : MODE SET key. Switch into following modes: Program Mode, Grand Total Check Mode.
RE-ZERO : RE-ZERO key. Resets weight display to zero.
T : TARE key. Set or clears tare value.
C : CLEAR key. Clears numerical values.
0 to 9 : Numeric keys. Input numerical value.
CODE : CODE key. Enter PLU code.
FIX : FIX key. To fix tare weight or PLU/unit price.
* : Data Setting key. Set up or clear mode.
1 to 15 : PRESET keys. Set up or call either unit price.
14. Block Diagram of Electrical Connection

DS-781
DS-782
15. Physical layout of Electrical Connection

CUSTOMER DISPLAY BOARD


40P
STB-2121
CN1

4 C SIZE
DRY BATTERY
SCW-D192

SCW-D191
RS232 I/F

DC JACK
LOAD CELL
95
D1

190
W-

SCW-D
S C

SCW-D144 A/D (RFI)


(STB-2120)

CN4 CN2 CN1


5P 2P 2P

CN6 (40P)

5P CN7 DS781 MAIN BOARD


CN1 (STB-2119)

KEYBOARD

DS-781
CUSTOMER DISPLAY BOARD
40P
STB-2121
CN1

RECHARGEABLE
BATTERY ( 6V)

RECEPTABLE
SCW-D192

SCW-D152
RS232 I/F

LOAD CELL
95
-D1

TRANSFOMER
SCW

SCW-D144 A/D ( RFI)


(STB-2120)

CN4 CN2 CN1


5P 2P 2P

CN6 (40P)

5P CN7 DS782 MAIN BOARD


CN1 (STB-2125)

KEYBOARD

DS-782

16. Hardware Description


16.1. Microcomputer
The R5F21255 / R5F21256 / R5F21257 / R5F21258 Microcomputer was chosen for the following reasons:
* Cheaper.
* Low voltage low power consumption.
* On-chip oscillator.
* On-chip power-on reset circuit and voltage detection circuit.
* Flash programming and erasure endurance: 1000 times for program ROM and 10000 times data flash.
* 20 interrupt sources and efficient interrupt processing.
* 4 versatile timers.
* 12 channels 10-bit A/D converter.
* Pin compatibility of similar package with difference ROM sizes.
* Good support.
16.2. Pin Assignment
Pin I/O Assignment Device Remark
P00/AN7 I DCVOLT(DS-781) DC Power(DS-781) Detects DC Power(DS-781)
ACVOLT(DS-782) AC Power(DS-782) Detects AC Power(DS-782)
P01/AN6 O BTVOLT Battery Detects Battery Voltage
*DS-782only *DS-782only *DS-782only

P02/AN5 O - - NC
P03/AN4 O - - NC
P04/AN3 O - - NC
P05/AN2 O - - NC
P06/AN1 O - - NC
P07/AN0 O EEPCS 93C46 EEPROM CS (Reserved)
P10/K10/AN8 O CBUZZ Buzzer Buzzer Sounder
P11/K11/AN9 O EEPSK 93C46 EEPROM Serial Clock (Reserved)
P12/K12/AN10 O EEPDO 93C46 EEPROM Serial Data Out (Reserved)
P13/K13/AN11 I EEPDI 93C46 EEPROM Serial Data In (Reserved)
P14/TXD0 O CTXD0 3232E RS-232C TXD
P15/RXD0 I CRXD0 3232E RS-232C RXD
P16/CLK0 O CRTS0 3232E RS-232C RTS
P17/TRAIO/INT1 I CCTS0 3232E RS-232C CTS
P20/TRDIOA0 O T1 Keyboard Key Scanning Line
P21/TRDIOB0 O T2 Keyboard Key Scanning Line
P22/TRDIOC0 O T3 Keyboard Key Scanning Line
P23/TRDIOD0 O T4 Keyboard Key Scanning Line
P24/TRDIOA1 O T5 Keyboard Key Scanning Line
P25/TRDIOB1 O T6 Keyboard Key Scanning Line
P26/TRDIOC1 O - - NC
P27/TRDIOD1 O - - NC
P30/TRAO O BTPW BATT-PW Controls battery power
P31/TRBO O BTCHG BATT-CHARGER Controls battery charger
*DS-782only *DS-782only *DS-782only

P33/SSI O CBKL Back-light Controller Controls Back-light


*DS-782only *DS-782only *DS-782only

P34/SDA/SCS O SDA BU9792FUV LCD Controller/Driver Serial Clock


P35/SCL/SSCK O SCL BU9792FUV LCD Controller/Driver Serial Data
P37/SSO O - - NC
P42/VREF I - - A/D Reference Voltage
P43/XCIN O ADPOWN TI1232 Power Down and Reset
P44/XCOUT O ADCLK TI1232 Serial Clock
P45/INT0 I ADDO TI1232 Serial Data
P46/XIN I - - Connect to VCC via resistor
P47/XOUT I - - Connect to VCC via resistor
P60/TREO I K1 Keyboard Key Return Line
P61 I K2 Keyboard Key Return Line
P62 I K3 Keyboard Key Return Line
Pin I/O Assignment Device Remark
P63 I K4 Keyboard Key Return Line
P64 I K5 Keyboard Key Return Line
P65/CLK1 I K6 Keyboard Key Return Line
P66/INT2/TXD1 O - - NC
P67/INT3/RXD1 I K_ON/OFF Keyboard Key Return Line
VCC/AVCC I - - Power Supply / Analog Power Supply
VSS/AVSS I - - Power Supply / Analog Power Supply
MODE I - - Mode Input
RESET I - - Reset Input
17. Maintenance Mode
17.1. SPAN Switch and Software Version Check
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0. 0 0 0.0 0 Weighing mode.
[RE-ZERO] 88888 88888 888888 Enter 2 8 4 while pressing
[RE-ZERO] + [2] [8] [4] StE28 V r x. x x S-ON [RE-ZERO].
(*DS-781)

StE29
(*DS-782)

Display software ID code in weight column,


version in unit price column. Display S-ON in
total price column when SPAN switch is set to
enable, Can access to 142 and calibration
mode.

StE28 V r x. x x S-OFF Display S-OFF when SPAN switch is set to


(*DS-781) disable. Can not access to 142 and calibration
StE29 mode.
(*DS-782)

0.0 0 0 0.0 0 0.0 0 Goes back to Weighing mode after 3 seconds


display.

17.2. SPAN Adjustment


NOTE: It can work only when SPAN SWITCH is on (Enable).
17.2.1. Full capacity weight for SPAN Adjustment
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0. 0 0 0.0 0 Weighing mode.
[RE-ZERO] 88888 88888 888888 Enter 8 7 1 5 while pressing
[RE-ZERO] + [8] [7] [1] [5] CAL00 RE-ZERO.
Ensure no weight on platter, [*] - - - - - Calibrating zero point.
CALSP Displays “CALSP”
Put full capacity weight on platter 1 5.0 0 0 and full capacity(e.g. 15kg) alternately.
(e.g. 15kg), [*] - - - - - Calibrating Span.
After calibration 1 5.0 0 0 0.0 0 0.0 0 Goes back to Weighing mode.
17.2.2. Proportion of capacity weight for SPAN Adjustment
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0. 0 0 0.0 0 Weighing mode.
[RE-ZERO] 88888 88888 888888 Enter 8 7 1 5 while pressing
[RE-ZERO] + [8] [7] [1] [5] CAL00 RE-ZERO.
Ensure no weight on platter, [*] - - - - - Calibrating zero point.
Place weight to be calibrated on the CALSP Displays “CALSP”
Platter (e.g. 6kg) 1 5.0 0 0 and full capacity(e.g. 15kg) alternately.
[C] 1 3.5 0 0 [C] key to set weight used for calibration.
[C] 1 2.0 0 0 Decreased at 10% of capacity rate.
:
:
[C] 6.0 0 0 Set to 6kg.
[*] - - - - - Calibrating Span.
After calibration 6.0 0 0 0.0 0 0.0 0 Goes back to Weighing mode.
Put 15kg weight on platter 1 5.0 0 0 0.0 0 0.0 0
17.3. Escape from Maintenance mode
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0. 0 0 0.0 0 Weighing mode.
[RE-ZERO] 88888 88888 888888 Enter 8 7 1 5 while pressing
[RE-ZERO] + [8] [7] [1] [5] CAL00 RE-ZERO.
[T] 0.0 0 0 0. 0 0 0.0 0 Escape to Weighing mode.

[RE-ZERO] 88888 88888 888888 Enter 8 7 1 5 while pressing


[RE-ZERO] + [8] [7] [1] [5] CAL00 RE-ZERO.
Ensure no weight on platter, [*] - - - - - Calibrating zero point.
:
:
CALSP
[T] 0.0 0 0 0. 0 0 0.0 0 Escape to Weighing mode.
17.4. Specification Setting
17.4.1. Specification Enter (141)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[RE-ZERO] 88888 88888 888888 Enter 1 4 1 while depressing
[RE-ZERO] + [1] [4] [1] XXXX XXXX S P E C 0 0 RE-ZERO.
[+] XXXX XXXX S P E C 0 1 + key only increase Specification.
[-] XXXX XXXX S P E C 0 0 - key only decrease Specification.
[8] XXXX 0008 SPEC00 (00 ~ 19 is enabled)
[X] XXXX XXXX S P E C 0 8 Goes to a designed Specification count.
[0] [1] [0] [1] XXXX 0101 SPEC08 Only 1 & 0 are valid Specification data.
[*] XXXX XXXX S P E C 0 9 * key to update Specification, increase
[1] [1] [0] [0] XXXX 1100 SPEC09 Specification count.
[C] XXXX 0000 SPEC09 Clears entered data.
[-] 0101 0101 SPEC08 SPEC08 has been updated.
[T] 0.0 0 0 0.0 0 0.0 0 Store SPECS to EEPROM & escape to
Weighing mode.

17.4.2. Specification Enter (142)


NOTE: It can work only when SPAN SWITCH is on (Enable).
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0. 0 0 0.0 0 Weighing mode.
[RE-ZERO] 88888 88888 888888 Enter 1 4 2 while depressing
[RE-ZERO] + [1] [4] [2] XXXX XXXX S P E C 2 0 RE-ZERO.
[+] XXXX XXXX S P E C 2 1 + key only increase Specification.
[-] XXXX XXXX S P E C 2 0 - key only decrease Specification.
[2] [9] XXXX 0029 SPEC20 (20 ~ 47 is enabled)
[X] XXXX XXXX S P E C 2 9 Goes to a designed Specification count.
[0] [1] [0] [1] XXXX 0101 SPEC29 Only 1 & 0 are valid Specification data.
[*] XXXX XXXX S P E C 3 0 * key to update Specification, increase
[1] [1] [0] [0] XXXX 1100 SPEC30 Specification count.
[C] XXXX 0000 SPEC30 Clears entered data.
[-] 0101 0101 SPEC29 SPEC29 has been updated.
[T] 0.0 0 0 0.0 0 0.0 0 Store SPECS to EEPROM & escape to
Weighing mode.
17.5. Internal Count & A/D Count Display
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[RE-ZERO] 88888 88888 888888 Enter 0 0 9 while depressing
[RE-ZERO] + [0] [0] [9] 5 18992 0 RE-ZERO.
Weight and Unit Price column display A/D
Count, Total Price column Display Internal
Count.
[T] 0.0 0 0 0.0 0 0.0 0 T key to go back Weighing mode.

17.6. Tax Setting


(Available when SPEC21.BIT2 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 0 0 0.0 0 0.0 0 Weighing mode.
[RE-ZERO] 88888 88888 888888 Enter 9 9 9 while pressing
[RE-ZERO] + [9] [9] [9] tA 0.0 0 0.0 0 RE-ZERO.
[3] [0] [0] tA 0.0 0 3.0 0 Enter Tax Rate, e.g. 3.00%.
[RE-ZERO] rd45 3.0 0 0.0 0 RE-ZERO to store specification.
[C] CUtOF 3.0 0 0.0 0 Depress ‘C’ to select Cut Off
[C] rd45 3.0 0 0.0 0 Or Rounding.
[T] 0.0 0 0 0.0 0 0.0 0 Store Tax Rate to EEPROM & return to
Weighing mode.

17.7. Operational Specification List


For The Customer - (1 4 1)

SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0


0 Auto Power-off function
0000 - Disable 0100 - 1 hour
0001 - 3 minute 0101 - 3 hours
0010 - 10 minutes 0110 ~ 1111 - Not used
0011 - 30 minutes
1 Buzzer Error alarm Weight sensitivity

0 - On 0 - On 00 - Low 10 - High Middle


1 - Off 1 - Off 01 - Middle 11 - High
2 Tare override Unit price override Zero unit price
override

0 - Allow 0 - Allow 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Inhibit
3 Back-light function *DS-782 only Auto back-light interval *DS-782 only
(Effective only if SPEC01.32 set to 00)
00 - Auto 10 - Always off 00 - 6s 10 - Not used
01 - Always on 11 - Not used 01 - 15s 11 - Not used
4 Currency conversion operation method

00 - Inhibit currency conversion operation


01 - Method 1
10 - Method 2
11 - Not used
5 Decimal point position on currency conversion rate

000 - 7th digit (0.XXXXXX) 100 - 3rd digit (XXXX.XX)


001 - 6th digit (X.XXXXX) 101 - 2nd digit (XXXXX.X)
010 - 5th digit (XX.XXXX) 110 - No decimal point (XXXXXX)
011 - 4th digit (XXX.XXX) 111 - Not used
6 RTS/CTS handshaking Baud rate of RS-232C *RS type only
of RS-232C *RS type only
000 - 1200 bps 100 - 19200 bps
0 - On 001 - 2400 bps 101 - 38400 bps
1 - Off 010 - 4800 bps 110 - Not used
011 - 9600 bps 111 - Not used
7 Stop bit of RS-232C Data length of Parity of RS-232C *RS type only
*RS type only RS-232C *RS type
only

0 - 1 bit 00 - None 10 - Even


1 - 2 bit 0 - 7 bit 01 - Odd 11 - Not used
1 - 8 bit
8 Interval of time out error of RS-232C Transmission Additional parity code
*RS type only condition of RS-232C in text of RS-232C
*RS type only *RS type only

00 - 1 second 10 - 5 second 0 - Weight stable 0 - No


01 - 3 second 11 - 10 second 1 - Unconditional 1 - Yes
9 Tare Weight in text of Unit Price in text of Total Price Weight in
RS-232C RS-232C text of RS-232C
*RS type only *RS type only *RS type only

0 - No 0 - No 0 - No
1 - Yes 1 - Yes 1 - Yes
SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
10 Data transfer protocol of RS-232C *RS type only

00000 - Inhibit data transfer


00001 - Type A (Standard stream)
00010 - Type W (Standard manual)
00011 - Type B (Standard command)
00100 - Type C (QUQA TRADING)
00101 - Type D (IBM, HUGIN)
00110 - Type E (ICL OLD)
00111 - Type F (ICL PORTUAGAL)
01000 - Type G (ICL ACTUAL)
01001 - Type H (CAS)
01010 - Type I (CAS PORTUAGAL)
01011 - Type J (NIXDORF)
01100 - Type K (NCR)
01101 - Type L (MONS)
01110 - Type M (Checkout-Dialog 02/04)
01111 - Type N (DATECS MP50/500)
10000 - Type O (NCI4000)
10001 - Type P (Checkout-Dialog 06)
10010 - Type Q (UNIWELL, ICL OLD OMRON)
10011 - Type R (ICL ACTUAL OMRON)
10100 - Type S (ICL CS500)
10101 - Type T (DTS)
10110 - Type U (SHARP UP-600/700, American Version)
10111 - Type V (NCI-ECR, Metrologic)
11000 - Type X (WTN) (sending key)
10111 ~ 11111 - Not used
11 Data transfer protocol
of RS-232C

BIT4 of Data transfer


protocol of RS-232C
12 Calculate and check Key operation for tare Number of status bytes
validity of CS, KW in Pos-Weigh-Mode (for (for NCI-ECR only)
(for Checkout-Dialog 06 only) Checkout-Dialog 02/04 and 06
only)

0 - No 0 - Allow 0 - 2 bytes
1 - Yes 1 - Inhibit 1 - 4 bytes
13 - 19
For Weight & Measure - (1 4 2)
NOTE: It can work only when the SPAN Switch is on (Enable)

SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0


20 Version display when Selection of Start range
power on segment-check style

0 - Allow 0 - Fast 00 - ±10% F.S. 10 - ±3% F.S.


1 - Inhibit 1 - Standard 01 - ±5% F.S. 11 - ±2% F.S.
21 Price Base Re-zero range

00 - $ / kg 10 - $ / lb 00 - ±2% F.S. 10 - Not used


01 - $ / 100g 11 - $ / 1/4lb 01 - ±3% F.S. 11 - Not used
22 Decimal point position on weight display Decimal point position on unit and total price
display

00 - No decimal point 00 - No decimal point for Unit & Total Price


01 - 2nd digit (0000.0) 01 - 2nd digit (0000.0) for Unit,
10 - 3rd digit (000.00) 2nd digit (00000.0) for Total Price
11 - 4th digit (00.000) 10 - 3rd digit (000.00) for Unit,
3rd digit (0000.00) for Total Price
11 - Not used
23 Minimum display Selection of resolution

00 - 1 10 - 5 00 - 1/3000 10 - 1/7500
01 - 2 11 - 10 01 - 1/6000 11 - Not used
24 Weight single interval Net / Gross Negative weight display mask
or multi-interval Multi-interval

0 - Single interval 0 - Gross 00 - Minus gross > 9e


1 - Multi-interval 1 - Net 01 - Minus gross weight
10 ~ 11 - Not used
25 Rounding for total price Re-zero function Fix function

00 - Rounding 10 - Cut up 0 - Allow 0 - Allow


01 - Truncation 11 - Not used 1 - Inhibit 1 - Inhibit
26 Additional rounding for total price Additional rounding
for kati display
000 - No additional rounding
001 - 1/4 rounding (25 step) 0 - Allow
010 - Special rounding (5 step) 1 - Inhibit
011 - 5 floor rounding (0-4 -> 0, 5-9 -> 5)
100 - Rounding for 1st digit
101 - Truncate 1st digit
110 - Cut up 1st digit
111 - Not used
SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
27 Manual tare Tare subtraction Tare accumulation Auto tare clear when
cancellation rezero

0 - Allow 0 - Allow 0 - Allow 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
28 Digital tare PLU tare / Preset tare Accumulation when Zero tracking when
tare tare

0 - Allow 0 - Allow 0 - Allow 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
29 Weight reset when tare Tare auto clear Unit price auto clear Price Base auto clear

0 - Allow 0 - Allow 0 - Allow 0 - Allow (For UK)


1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
30 Auto clear condition Tax Change operation WT data
Method synchronization (+ key
only)

0- >= Gross 21e 0 - Allow 0 - Indirect (method B) 0 - Allow


& >= Net 5e 1 - Inhibit 1 - Direct (method A) 1 - Inhibit
1- >=Net 1e & price
not 0
31 Accumulation number Accumulation Price accumulation Price accumulation
display display style without removing without change weight
weight (for >= ±10e)

0 - Allow 0 - Standard (“total”) 0 - Allow 0 - Allow


1 - Inhibit 1 - Japan (“Add”) 1 - Inhibit 1 - Inhibit
32 Exit from Exit from IR mode protected by Password setting
accumulation mode accumulation mode SPAN SW
after 15 sec time out when weight change

0 - Allow 0 - Allow 0 - No 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Yes 1 - Inhibit
33 Non-weigh item Weight range of Weight stability condition
accumulation Non-weigh item

0 - Allow 0 - Always 00 - Loose 10 - Tight


1 - Inhibit 1 - Net 0d 01 - Normal 11 - Stringent
34 Decimal point position on price display in Rounding for currency conversion
secondary currency

00 - No decimal point for Unit & Total Price 00 - Rounding


01 - 2nd digit (0000.0) for Unit, 01 - Truncation
2nd digit (00000.0) for Total Price 10 - Cut up
10 - 3rd digit (000.00) for Unit, 11 - Not used
3rd digit (0000.00) for Total Price
11 - Not used
35 Exit from secondary Currency symbol for Indicator for Inverse currency
currency mode when secondary currency secondary currency conversion function
weight change (for >
±2e)

0 - Allow 0 - No symbol 0 - Allow 0 - Allow


1 - Inhibit 1 - ‘EURO’ 1 - Inhibit 1 - Inhibit
36 Accumulation Subtraction Multiplication PLU function

0 - Allow 0 - Allow 0 - Allow 0 - Allow


1 - Inhibit 1 - Inhibit 1 - Inhibit 1 - Inhibit
37 Price Base change Currency conversion UNIT function
key(100g/kg, 1/4lb/lb) function

0 - Allow (For UK) 0 - Allow 00 - Inhibit


1 - Inhibit 1 - Inhibit 01 - kg and lb conversion
10 - kg, decimal lb and kati conversion (for HK)
11 - Not used
38 Change function Display hold Auto Zero function

0 - Allow 0 - Allow 0 - Allow (for Japan)


1 - Inhibit 1 - Inhibit 1 - Inhibit
39 Weight range of data Permission of Weight Weight change or
output change or remove remove check of data
*RS type only check for data output output
(for NCI-ECR only) *RS type only

0 - Always 0 - Allow 0 - Change


1 - Over 20e 1 - Inhibit 1 - Remove
40 Division for weight change check *RS type only

0000 - 1e 1000 - 9e
0001 - 2e 1001 - 10e
0010 - 3e 1010 - 20e
0011 - 4e 1011 - 30e
0100 - 5e 1100 - 40e
0101 - 6e 1101 - 50e
0110 - 7e 1110 - 60e
0111 - 8e 1111 - 70e
SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
41 - 47

18. Operations In Weighing Mode


18.1. ON/OFF
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[ON/OFF] 8.8.8.8.8. 8.8.8.8.8. 8.8.8.8.8.8. Display for 1 seconds. *Note1
Blank for 1 seconds.
8.8.8.8.8. 8.8.8.8.8. 8.8.8.8.8.8. Display for 1 seconds.
Blank for 1 seconds.
88888 88888 888888
Ready to operate 0.0 0 0 0.0 0 0.0 0 Weighing mode.
[ON/OFF] OFF.
* Note1: Power On Segment Check Style can be selected by setting SPEC20.2. In this example assume SPEC20.2 = 0.

18.2. Tare Subtraction


18.2.1. One Touch Tare Subtraction
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
0.0 3 0 0.0 0 0.0 0 Put tare (e.g 30 g) on platter.
[T] 0.0 0 0 0.0 0 0.0 0 Subtract the tare weight.
Remove the tare weight - 0.0 3 0 0.0 0 0.0 0
[T] 0.0 0 0 0.0 0 0.0 0 Clear the tare weight.

18.2.2. Digital Tare Subtraction


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[5] 0.0 0 0 0.0 5 0.0 0 Key in the tare weight (e.g 5g).
[T] - 0.0 0 5 0.0 0 0.0 0 Subtract the tare weight (Assume 15kg).
[T] 0.0 0 0 0.0 0 0.0 0 Clear the tare weight.
18.3. Plural Operation
18.3.1. Standard Version
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [0] [0] [0] 0.0 0 0 1 0.0 0 0.0 0 Enter unit price.
Put product on platter. 0.5 0 0 1 0.0 0 5.0 0
[+] tOtAL 1 5.0 0 Accumulation the data.
Remove product from platter. tOtAL 1 5.0 0
[1] [5] [0] [0] 0.0 0 0 1 5.0 0 0.0 0 Enter unit price.
[+] tOtAL 2 2 0.0 0 Fixed price accumulation.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[+] tOtAL 2 2 0.0 0 Enter accumulation mode.
[+] tOtAL 2 2 0.0 0 Nothing happen.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing mode.

18.3.2. Japan Type A Version


(When SPEC31.2 = 1 and SPEC31.3 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [0] [0] [0] 0.0 0 0 1 0.0 0 0.0 0 Enter unit price.
Put product on platter. 0.5 0 0 1 0.0 0 5.0 0
[+] Add 1] 5.1 5 Accumulation the data(assume tax rate = 3%).
Remove product from platter. Add 1] 5.1 5
[1] [5] [0] [0] 0.0 0 0 1 5.0 0 0.0 0 Enter unit price.
[+] Add 2] 2 0.6 0 Fixed price accumulation.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing mode.

18.3.3. Japan Type B Version


(When SPEC31.2 = 1 and SPEC31.3 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [0] [0] [0] 0.0 0 0 1 0.0 0 0.0 0 Enter unit price.
Put product on platter. 0.5 0 0 1 0.0 0 5.0 0
[+] Add 5.0 0 5.1 5 Accumulation the data (tax rate = 3%).
Remove product from platter. Add 5.0 0 5.1 5
[1] [5] [0] [0] 0.0 0 0 1 5.0 0 0.0 0 Enter unit price.
[+] Add 2 0.0 0 2 0.6 0 Fixed price accumulation.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing mode.
18.4. Multiplication Operation
18.4.1. Standard Version
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
0.4 1 2 1 2.3 4 5.0 8 Put product on platter.
[+] tOtAL 1 5.0 8 Accumulation the data.
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[x] PCS 0 5.0 0 0.0 0 Depress multiply key.
[2] [0] PCS 20 5.0 0 1 0 0.0 0 multiply the data by 20.
[+] tOtAL 21 1 0 5.0 8 Accumulation the data.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing mode.

18.4.2. Japan Type A Version


(When SPEC31.2 = 1 and SPEC31.3 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
0.4 1 2 1 2.3 4 5.0 8 Put product on platter.
[+] Add 1] 5.2 3 Accumulation the data (assume tax rate = 3%)
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[x] 0] 5.0 0 0.0 0 Depress multiply key.
[2] [0] 20] 5.0 0 1 0 0.0 0 multiply the data by 20.
[+] Add 2 1] 1 0 8.2 3 Accumulation the data.
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing mode.

18.4.3. Japan Type B Version


(When SPEC31.2 = 1 and SPEC31.3 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
0.4 1 2 1 2.3 4 5.0 8 Put product on platter
[+] Add 5.0 8 5.2 3 Accumulation the data (assume tax rate = 3%)
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[x] 0] 5.0 0 0.0 0 Depress multiply key
[2] [0] 20] 5.0 0 1 0 0.0 0 multiply the data by 20
[+] Add 1 0 5.0 8 1 0 8.2 3 Accumulation the data
[*] 0.0 0 0 0.0 0 0.0 0 Clear current total & return to weighing mode.
18.5. AMT/TEND Key Operation
18.5.1. Method A (Direct entry method: SPEC30.1 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [5] [0] 0.0 0 0 1 2.5 0 0.0 0 Enter unit price.
Put product on platter. 0.4 2 0 1 2.5 0 5.2 5
[+] tOtAL 1 5.2 5 Accumulation the data.
Remove product from platter. tOtAL 1 5.2 5
[6] [0] [0] 0.0 0 0 6.0 0 0.0 0 Enter the amount tendered.
[AMT/TEND] CHG 0.7 5 Compute change & clear current total.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[+] tOtAL 0 0.0 0 Check total data.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

18.5.2. Method B (Indirect entry method: SPEC30.1 = 0)


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [5] [0] 0.0 0 0 1 2.5 0 0.0 0 Enter unit price.
Put product on platter. 0.4 2 0 1 2.5 0 5.2 5
[+] tOtAL 1 5.2 5 Accumulation the data.
Remove product from platter. tOtAL 1 5.2 5
[AMT/TEND] tnd 5.2 5 Prepare to compute change.
[6] [0] [0] tnd 6.0 0 Enter the amount tendered.
[*] CHG 0.7 5 Compute change & clear current total.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[+] tOtAL 0 0.0 0 Check total data.
[C] 0.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

18.6. Correction Of Past Sales Data


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
Put product on platter. 2.0 0 0 1 2.3 4 2 4.6 8
[+] tOtAL 1 2 4.6 8 Accumulation the data.
Remove product from platter. tOtAL 1 2 4.6 8
[5] [0] [0] 0.0 0 0 5.0 0 0.0 0 Enter unit price.
[+] tOtAL 2 2 9.6 8 Accumulation the data .
[1] [2] [3] [4] 0.0 0 0 1 2.3 4 0.0 0 Enter unit price.
Put product on platter. 2.0 0 0 1 2.3 4 2 4.68
[-] Corr 1 5.0 0 Perform past sale data correction.
[C] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
18.7. Price Base Change By 100g/kg Key
(Available when SPEC37.3 = 0)
1 - ZERO 2 - NET 3 - kg 4 - 100g 5 - MEMORY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
[1] [0] [0] 0.0 0 0 1.0 0 0.0 0 Key in unit price.
[100g/kg] 0.0 0 0 1.0 0 0.0 0 Change price base to $/100g.
Put product on platter. 1.0 0 0 1.0 0 1 0.0 0
[C] 1.0 0 0 0.0 0 0.0 0 C key clear unit price and price base.
[100g/kg] 1.0 0 0 0.0 0 0.0 0 Change price base to $/100g.
[2] [0] [0] 1.0 0 0 2.0 0 2 0.0 0 Key in unit price.
[100g/kg] 1.0 0 0 2.0 0 2.0 0 Change price base to $/kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0

18.8. Auto Zero Operation


(Available when SPEC38.1 = 0)
1 - ZERO 2 - NET 3 – AUTOZERO 4 - MEMORY 5 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
0.0 0 0 0.0 0 0.0 0 Weighing mode.
Put 5g on platter. 0.0 0 5 0.0 0 0.0 0 Auto Zero function is ineffective.
[AUTO ZERO] 0.0 0 0 0.0 0 0.0 0 Auto Zero function is effective.
Add 20g on platter. 0.0 2 5 0.0 0 0.0 0 Exceed Auto Zero range (<5e).
Remove 20g from platter. 0.0 0 0 0.0 0 0.0 0
[AUTO ZERO] 0.0 0 5 0.0 0 0.0 0 Auto Zero function is cancelled.

18.9. kg and lb conversion by UNIT Key


(Available when SPEC37.10 = 01)
1 - ZERO 2 - NET 3 - $/kg 4 - $/lb 5 - MEMORY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0 Weight in kg.
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price in $/kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0
[UNIT] 0.0 0 0 0.0 0 0.0 0 Change to lb.
Put product on platter. 1.1 0 0 0.0 0 0.0 0 Weight in lb.
[2] [0] [0] 1.1 0 0 2.0 0 2.2 0 Key in unit price in $/lb.
[UNIT] 0.5 0 0 2.0 0 1.0 0 Change to kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0
18.10. kg, decimal lb and kati conversion by UNIT Key
(Available when SPEC37.10 = 10)
1 - ZERO 2 - NET 3 - $/lb 4 - $/kati 5 - MEMORY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 5 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0 Weight in kg.
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price in $/kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0
[UNIT] 0. 0.0 0.0 0 0.0 0 Change to decimal lb.
Put product on platter. 1. 1.6 0.0 0 0.0 0 Weight in decimal lb.
[2] [0] [0] 1. 1.6 2.0 0 2.2 0 Key in unit price in $/lb.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0
[UNIT] 0. 0.0 0.0 0 0.0 0 Change to kati.
Put product on platter. 0.1 3.2 0.0 0 0.0 0 Weight in kati.
[2] [0] [0] 0.1 3.2 2.0 0 1.6 5 Key in unit price in $/kati.
[UNIT] 0.5 0 0 2.0 0 1.0 0 Change to kg.
Remove product, [C] 0.0 0 0 0.0 0 0.0 0

18.11. Currency Conversion by EURO Key


(Available when SPEC37.2 = 0)
18.11.1. Currency Conversion Operation Method 1 (SPEC4.32 = 01)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price.
[EURO] EURO 2.2 0 Display re-calculated total price in secondary
currency. Assume SPEC26.3 = 1, conversion
rate is 2.20.
[EURO] 0.5 0 0 2.0 0 1.0 0 Return to Weighing Mode.

18.11.2. Currency Conversion Operation Method 2 (SPEC4.32 = 10)


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
Put product on platter. 0.5 0 0 0.0 0 0.0 0
[2] [0] [0] 0.5 0 0 2.0 0 1.0 0 Key in unit price.
[EURO] EURO 4.4 0 2.2 0 Display re-calculated unit price & total price
in secondary currency. Assume SPEC26.3 =
1, conversion rate is 2.20.
[EURO] 0.5 0 0 2.0 0 1.0 0 Return to Weighing Mode.
19. Operations of Mode Set Key
19.1. Mode Change Using Mode Set Key
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2kg on the platter 2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE Depress [M] key twice within 3 seconds, enter
PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

19.2. PLU Setting


1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[1] [0] PLU 10 CodE Enter plu code. *Note1
[*] PLU 0.0 0 UP Display current unit price in PLU.
[1] [5] [0] PLU 1.5 0 UP Enter unit price.
[*] PLU 0.0 0 0 tArE Display current tare in PLU. *Note2
[1] [0] [0] PLU 0.1 0 0 tArE Enter tare. *Note2
[*] PLU 0 CodE Store PLU.
[M] [M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[1] [0] [CODE] 1.9 0 0 1.5 0 2.8 5 Call up PLU.
[C] 2.0 0 0 0.0 0 0.0 0 Clear PLU.
*Note1: Valid code number is 1 - 99.
*Note2: When PLU tare is allowed by SPEC28.2 = 0.

19.3. Preset Key Setting


19.3.1. Preset Key Setting when PLU function is allowed.
(When SPEC36.0 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[PRESET 1] P.S E t P L U 2 0 Display current PLU code in PRESET.
[C] P.S E t 0 Clear PRESET.
[1] [0] P.S E t 10 Enter PLU code.
[*] P.S E t Store PRESET.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[PRESET 1] 1.9 0 0 1.5 0 2.8 5 Call up PLU set in PRESET 1.
[C] 2.0 0 0 0.0 0 0.0 0 Clear PLU.
19.3.2. Preset Key Setting when PLU function is inhibited.
(When SPEC36.0 = 1)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] P.S E t 0.0 0 Preset key setting mode.
[1] [5] [0] P.S E t 1.5 0 Enter unit price.
[PRESET 1] P.S E t 0.0 0 Store unit price to PRESET1.
[T] P.S E t 0.0 0 0 tArE Change to set tare mode. *Note1
[1] [0] [0] P.S E t 0.1 0 0 tArE Enter tare. *Note1
[PRESET 2] P.S E t 0.0 0 Store tare to PRESET2. *Note1
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
[PRESET 2] 1.9 0 0 0.0 0 0.0 0 Call up tare set in PRESET 2.
[PRESET 1] 1.9 0 0 1.5 0 2.8 5 Call up unit price set in PRESET 1.
[C] 1.9 0 0 0.0 0 0.0 0 Clear unit price.
Remove product from platter - 0.1 0 0 0.0 0 0.0 0
[T] 0.0 0 0 0.0 0 0.0 0 Clear tare.
*Note1: When Preset tare is allowed by SPEC28.2 = 0.

19.4. Conversion Rate Setting


(Available when SPEC37.2 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] EURO rAtE 0 Enter into conversion rate setting mode.
[2] [2] [0] EURO rAtE 2. 2 0 Set conversion rate to 2.20.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.

19.5. Invert Currency Conversion Function


(Available when SPEC37.2 = 0 and SPEC35.0 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] EURO RAtE 0 Enter into conversion rate setting mode.
[RE-ZERO] 88888 88888 888888 Enter 2 0 0 1 while pressing RE-ZERO.
[RE-ZERO] + [2] [0] [0] [1] EURO InvErt EURO conversion function is inverted.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
*Note: When Invert Currency Conversion Function operation is performed, following change will be made internally:
1) The data set in SPEC22.10 and SPEC34.32 is exchanged.
2) Set SPEC35.2 = 0; SPEC35.1 = 0; SPEC35.0 = 1.
19.6. Cancel Currency Conversion Function
(Available when SPEC37.2 = 0)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
2.0 0 0 0.0 0 0.0 0 Weighing mode.
[M] [M] PLU 0 CodE PLU setting mode.
[M] P.S E t Preset key setting mode.
[M] EURO RA t E 0 Enter into conversion rate setting mode.
[RE-ZERO] 88888 88888 888888 Enter 2 0 0 2 while pressing RE-ZERO.
[RE-ZERO] + [2] [0] [0] [2] EURO CAnCEL EURO conversion function is cancelled.
[M] 2.0 0 0 0.0 0 0.0 0 Return to Weighing mode.
*Note: When Cancel Currency Conversion Function operation is performed, SPEC37.2 is set to 1 internally:

20. RS-232C Interface


20.1. Specification
Baud Rate : 1200 / 2400 / 4800 / 9600 / 19200 / 38400 BPS.
Start Bit : 1 Bit.
Stop Bit : 1 / 2 Bit.
Date Bit : 7 / 8 Bits.
Parity Bit : Even / Odd / None.

20.2. Pin Assignment


DS-781 PC SIDE
CN6(5pins) DIN 9 pins
1 RXD 2 RXD TXD
2 RTS 7 RTS
3 TXD 3 TXD RXD
4 CTS 8 CTS
5 GND 5 GND GND
*Note: RTS/CTS handshaking function is effective only when SPEC3.3 = 0.

20.3. Control Code and Characters


Termination Code CR The end of data 0x0d
LF The end of Text 0x0a
‘0’ ~ ‘9’ Numeric date 0x30 ~ 0x39
‘-‘ (Minus) Minus sign 0x2d
Date ‘.’ (Decimal) Decimal 0x2e
‘ ’(Space) Data error or empty 0x20
OF Overflow 0x4f 0x46
UF Underflow 0x55 0x46
‘0’ Net Weight 0x30
Header Code ‘4’ Tare Weight 0x34
‘U’ Unit Price 0x55
‘T’ Total Price 0x54
ENQ Enquiry 0x05
Command ACK Acknowledge 0x06
NAK Not Acknowledge 0x15
20.4. Data Format
A) Without additional parity (Total 37 Bytes )
Status Weight Condition CR Header Net CR Header Tare
Flag Flag Code Weight Code Weight
1 Byte 1 Byte 1 Byte 1 Byte 6 Bytes 1 Byte 1 Byte 6 Bytes

CR Header Unit CR Header Total CR LF


Code Price Code Price
1 Byte 1 Byte 6 Bytes 1 Byte 1 Byte 7 Bytes 1 Byte 1 Byte

B) With additional parity (Total 38 Bytes )


Status Weight Condition CR Header Net CR Header Tare
Flag Flag Code Weight Code Weight
1 Byte 1 Byte 1 Byte 1 Byte 6 Bytes 1 Byte Byte 6 Bytes

CR Header Unit CR Header Total CR Additional LF


Code Price Code Price Parity
1 Byte 1 Byte 6 Bytes 1 Byte 1 Byte 7 Bytes 1 Byte 1 Byte 1 Byte
*Note: If the additional parity is 0x0d, 0x0a or 0x00, it will be changed to 0x1d, 0x1a or 0x10 respectively.

Status Flag:
Not Fixed Not Price Price Total Price Net Additional
Used to 1 used Base Base Overflow Parity
Bit 7 : Not used. Always 0;.
Bit 6 : Fixed to 1.
Bit 5 : Not used.
Bit 4 and Bit 3 : Price Base. 00 - $/kg, 01 - $/100g, 10 - $/1b, 11 - $/1/41b.
Bit 2 : Total Price Overflow. Set to 1 when total price overflow, 0 when not.
Bit 1 : Net. Set to 1 When tare subtraction is performed, 0 when not.
Bit 0 : Additional parity flag. Set to 1 when additional parity code is added in text, 0 when not.
Weight Condition Flag:

Not Fixed Not Weight Weight Negative Weight Zero


Used to 1 used UF OF Net Weight Stable Sign
Bit 7 : Not used. Always set 0.
Bit 6 : Fixed to 1.
Bit 5 : Not used.
Bit 4 : Weight UF. Set to 1 when weight underflow, 0 when not.
Bit 3 : Weight OF. Set to 1 when weight overflow, 0 when not.
Bit 2 : Negative Net Weight. Set to 1 when net weight is negative, 0 when not.
Bit 1 : Weight Stable. Set to 1 when weight is stable. 0 when not.
Bit 0 : Zero Sign. Set to 1 when weight zero sign is set. 0 when not.

Example1: Transmit all data.


Net weight = 3.456 Tare weight = 1.200 Unit Price = 1.500 ( $/kg)
Total Price = 5.184 Weight status : stable
Status Flag: 0x42

0 1 0 0 0 0 1 0
Weight Condition Flag: 0x42

0 1 0 0 0 0 1 0
By ASCII Code:

0x42 0x42 0x0d 0x30 0x30 0x33 0x2e 0x34 0x35 0x36 0x0d

0x34 0x30 0x31 0x2e 0x32 0x30 0x30 0x0d

0x55 0x30 0x31 0x2e 0x35 0x30 0x30 0x0d

0x54 0x30 0x30 0x35 0x2e 0x31 0x38 0x34 0x0d 0x0a

Example2: Only transmit Net weight and Total Price.


0x42 0x42 0x0d 0x30 0x30 0x33 0x2e 0x34 0x35 0x36 0x0d

0x54 0x30 0x30 0x35 0x2e 0x31 0x38 0x34 0x0d 0x0a

Example3: When weight is overflow, the following data is output.


0x42 0x48 0x0d 0x30 0x20 0x20 0x20 0x20 0x4f 0x46 0x0d

0x34 0x30 0x31 0x2e 0x32 0x30 0x30 0x0d

0x55 0x30 0x31 0x2e 0x35 0x30 0x30 0x0d

0x54 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x0d 0x0a

20.5 Communication Method


The data communication method can be selected from Stream(continuous), Manual,
and Command by specification settings.
20.5.1 Type A (Standard Stream)
Data is transmitted to PC side continuously.

PC SIDE SCALE

PC SCALE

No
Ready ?

[Text String] Yes

Note: Weight stable check depends on SPEC setting.


20.5.2 Type W (Standard Manual)
Data is output by pressing Manual key(+ key). User may select to transmit the data right away or
hold the command until weight become stable by specification setting.

PC SIDE SCALE

Key Press

[ENQ]
Ready ?

No

No
X Second ?

Yes

PC

[NAK]
End Immediately

No Responds
Time Out (3 Sec)

[ACK]

SCALE

[Text String]

PC

[NAK]

Normal End

Note: Weight stable check depends on SPEC setting.


20.5.3 Type B (Standard Command)
The data transmission starts by receiving the command from external (Ex. PC side).

PC SIDE SCALE

[ENQ]
PC

[NAK] No
Weighing Mode ?

Yes

[Text String} Yes


Ready ?

No

[NAK] Yes No
X Second ?

Normal End

*Note: Weight stable check depends on SPEC setting.

21. Error Massage List


The following error message will appear when an incorrect operation is performed.
Message Remarks Appropriate Operation
888888 When scale is not steady when power on. Place scale on firm, flat base.
OF When weight exceeds capacity+9d, or something is on the Remove the item on the platter.
platter when power on.
UF When negative weight exceeds display limit. REZERO or ON/OFF again.
TotAl When current Total overflow. Clear current Total.
FULL
Error When error occurs in maintenance mode. Repeat operation.
ERR 01 When A/D error. Contact dealer.
ERR 02 When data flash erase error. Contact dealer.
ERR 03 When data flash program error. Contact dealer.