Digi DS782 Setup Guide PDF
Digi DS782 Setup Guide PDF
Add a PLU
Press the mode key twice
Select the a PLU number
Press enter
Type in a price
Press enter
Press the mode key three times
Select the preset key that you want to put the PLU on
Confirm by typing in the PLU number then enter
Spec settings
Below is a list of variable settings that you can edit on the scale
To get into this mode hold the ‘Rezero’ key and type 141
Now type in the spec number (of what you want to change)
Press enter
Now type in the number relating to what setting you want
Press enter to save
0 - No 0 - Allow 0 - 2 bytes
1 - Yes 1 - Inhibit 1 - 4 bytes
13 – 19
1111
Side(Pole Type)
①:Power Interface
②:Backup battery
③:Operator displays
④:Keyboard
⑤:Platter
⑥:Nameplate
⑦:Customer displays(Pole Type)
1. General Layout
1.1. Bench Type
1.2. Pole Type
2. Features
* Low power consumption LCD digital price computing scale.(DS781)
Low power consumption LCD with back-light digital price computing scale.(DS782)
* Quick response to weight changes.
* Capacity : 3kg, 6kg, 15kg, 30kg, 6lb, 15lb, 30lb and 60lb.
* Resolution : Display Resolution 1/3000.
Internal Resolution 1/90000.
* Low power consumption :
- DS781: Battery(4 x C size dry battery) backup for more than 200 hours of continuous usage.
- DS781RS: Battery(4 x C size dry battery) backup for more than 120 hours of continuous usage.
- DS782: Rechargeable Battery backup for more than 600 hours of continuous usage. (Back-light function
is off)
- DS782RS: Rechargeable Battery backup for more than 380 hours of continuous usage. (Back-light
function is off).
* Two-Point battery low detect(DS781)
A. When battery is weak, the Battery indicator will light up.
B. When the power from battery becomes low such that the scale can not compute accurately,
all displays will shut off except the Battery indicator. The power is then shut off completely after 1minute.
3. Operating Conditions
DS781:
* Power Source : 4 x C size dry battery or AC/DC Adapter(DC 5V ~ 8V, 100mA).
* Operating Temperature : -10℃ ~ +40℃.
* Operating Humidity : 15 ~ 85% RH.
* Power Consumption : 0.24W when DC 6V..
: 0.12W when using dry battery.
DS782:
* Power Source : AC 240/230/220V, 117/100V.
: DC 6V 5Ah rechargeable battery (optional).
* Operating Temperature : -10℃ ~ +40℃.
* Operating Humidity : 15 ~ 85% RH.
* Power Consumption : 18W when using AC power.
: 1.2W when using rechargeable battery.
Type A
Type B
8. Key Functions
MODE : MODE SET key. Switch into following modes: Program Mode, Grand Total Check Mode.
RE-ZERO : RE-ZERO key. Resets weight display to zero.
T : TARE key. Set or clears tare value.
C : CLEAR key. Clears numerical values.
0 to 9 : Numeric keys. Input numerical value.
CODE : CODE key. Enter PLU code.
FIX : FIX key. To fix tare weight or PLU/unit price.
* : Data Setting key. Set up or clear mode.
Used as data send key for RS232C type.
+ : Accumulation key. Adds sum or accumulate sum.
- : Minus key. Correct operation on products.
x : Multiply key. Register the same non-weighing product multiple times.
AMT/TEND : Enters amount tendered. Two different types of AMT/TEND operation can be selected by
SPEC.
1 to 11 : PRESET keys. Set up or call either unit price.
MODE : MODE SET key. Switch into following modes: Program Mode, Grand Total Check Mode.
RE-ZERO : RE-ZERO key. Resets weight display to zero.
T : TARE key. Set or clears tare value.
C : CLEAR key. Clears numerical values.
0 to 9 : Numeric keys. Input numerical value.
CODE : CODE key. Enter PLU code.
FIX : FIX key. To fix tare weight or PLU/unit price.
* : Data Setting key. Set up or clear mode.
1 to 15 : PRESET keys. Set up or call either unit price.
9. Specification Setting
9.1. Specification Enter (141)
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[RE-ZERO] 88888 88888 888888 Enter 1 4 1 while depressing
[RE-ZERO] + [1] [4] [1] XXXX XXXX S P E C 0 RE-ZERO.
0
[+] XXXX XXXX S P E C 0 + key only increase Specification.
1
[-] XXXX XXXX S P E C 0 - key only decrease Specification.
0
[8] XXXX 0008 SPEC0 (00 ~ 19 is enabled)
0
[X] XXXX XXXX S P E C 0 Goes to a designed Specification count.
8
[0] [1] [0] [1] XXXX 0101 SPEC0 Only 1 & 0 are valid Specification data.
8
[*] XXXX XXXX S P E C 0 * key to update Specification, increase
9
[1] [1] [0] [0] XXXX 1100 SPEC0 Specification count.
9
[C] XXXX 0000 SPEC0 Clears entered data.
9
[-] 0101 0101 SPEC0 SPEC08 has been updated.
8
[T] 0.0 0 0 0.0 0 0.0 0 Store SPECS to EEPROM & escape to
Weighing mode.
00 - 1 second 10 - 5 second
01 - 3 second 11 - 10 second 0 - Weight stable 0 - No
1 - Unconditional 1 - Yes
9 Tare Weight in text Unit Price in text of Total Price Weight in
of RS-232C RS-232C text of RS-232C
*RS type only *RS type only *RS type only
0 - No 0 - No 0 - No
1 - Yes 1 - Yes 1 - Yes
10 Data transfer protocol of RS-232C *RS type only
0 - 2 bytes
0 - No 0 - Allow 1 - 4 bytes
1 - Yes 1 - Inhibit
13 - 19
10. Operations In Weighing Mode
10.1. ON/OFF
1 - ZERO 2 - NET 3 - MEMORY 4 - BATTERY
OPERATION WEIGHT U.PRICE T.PRICE 1 2 3 4 REMARKS
[ON/OFF] 8.8.8.8.8. 8.8.8.8.8. 8.8.8.8.8.8 Display for 1 seconds. *Note1
.
Blank for 1 seconds.
8.8.8.8.8. 8.8.8.8.8. 8.8.8.8.8.8 Display for 1 seconds.
.
Blank for 1 seconds.
88888 88888 888888
Ready to operate 0.0 0 0 0.0 0 0.0 0 Weighing mode.
[ON/OFF] OFF.
* Note1: Power On Segment Check Style can be selected by setting SPEC20.2. In this example assume SPEC20.2 = 0.
Side(Pole Type)
①:Power Interface
②:Backup battery
③:Operator displays
④:Keyboard
⑤:Platter
⑥:Nameplate
⑦:Customer displays(Pole Type)
1. General Layout
1.1. Bench Type
1.2. Pole Type
2. Purpose
To develop a low power consumption digital price computing scale which caters OIML Standard.
3. Features
* Low power consumption LCD digital price computing scale.(DS781)
Low power consumption LCD with back-light digital price computing scale.(DS782)
* Quick response to weight changes.
* Capacity : 3kg, 6kg, 15kg, 30kg, 6lb, 15lb, 30lb and 60lb.
* Resolution : Display Resolution 1/3000.
Internal Resolution 1/90000.
* Low power consumption :
- DS781: Battery(4 x C size dry battery) backup for more than 200 hours of continuous usage.
- DS781RS: Battery(4 x C size dry battery) backup for more than 120 hours of continuous usage.
- DS782: Rechargeable Battery backup for more than 600 hours of continuous usage. (Back-light function is off)
- DS782RS: Rechargeable Battery backup for more than 380 hours of continuous usage. (Back-light function is off).
DS782:
* Power Source : AC 240/230/220V, 117/100V.
: DC 6V 5Ah rechargeable battery (optional).
* Operating Temperature : -10℃ ~ +40℃.
* Operating Humidity : 15 ~ 85% RH.
* Power Consumption : 18W when using AC power.
: 1.2W when using rechargeable battery.
5. Analog Specification
* Input sensitivity : 1mV/V.
* Zero adjust range : 0 ± 3.3mV.
* Zero balance range : 0 ± 0.33mV.
* L/C applied voltage : DC 3.3V.
* Speed of A/D conversion : 10 times/sec.
* Internal Resolution : 90000.
6. Capacity/Minimum Graduation/Tare range
6.1. Single Interval
Capacity Minimum Graduation Tare Rang
3kg 1g (1e = 30IR) 0 - 1.499kg
6kg 2g (1e = 30IR) 0 - 2.998kg
15kg 5g (1e = 30IR) 0 - 7.495kg
30kg 10g (1e = 30IR) 0 - 14.99kg
6lb 0.002lb (1e = 30IR) 0 - 2.998lb
15lb 0.005lb (1e = 30IR) 0 - 7.495lb
30lb 0.01lb (1e = 30IR) 0 - 14.99lb
60lb 0.02lb (1e = 30IR) 0 - 29.98lb
6.2. Multi-Interval
Capacity Minimum Graduation Tare Rang
3kg 1g (1e = 10IR) 0 - 1.499kg
6kg (0-3kg)-1g (1e=15IR) (3-6kg)-2g (1e=30IR) 0 - 2.999kg
15kg (0-6kg)-2g (1e=12IR) (6-15kg)-5g (1e=30IR) 0 - 5.998kg
30kg (0-15kg)-5g (1e=15IR) (15-30kg)-10g (1e=30IR) 0 - 9.995kg
6lb (0-3lb)-0.001lb (1e=15IR) (3-6lb)-0.002lb (1e=30IR) 0 - 2.999lb
15lb (0-6lb)-0.002lb (1e=12IR) (6-15lb)-0.005lb (1e=30IR) 0 - 5.998lb
30lb (0-15lb)-0.005lb (1e=15IR) (15-30lb)-0.01lb (1e=30IR) 0 - 9.995lb
60lb (0-30lb)-0.01lb (1e=15IR) (15-30lb)-0.02lb (1e=30IR) 0 - 29.99lb
*NOTE : IR -> Internal Resolution, e -> Division(Minimum Increment).
Internal count(full capacity) = 90000IR.
7. Display and Indicators
Standard
Type A
Type B
13. Key Functions
DS-781
DS-782
15. Physical layout of Electrical Connection
4 C SIZE
DRY BATTERY
SCW-D192
SCW-D191
RS232 I/F
DC JACK
LOAD CELL
95
D1
190
W-
SCW-D
S C
CN6 (40P)
KEYBOARD
DS-781
CUSTOMER DISPLAY BOARD
40P
STB-2121
CN1
RECHARGEABLE
BATTERY ( 6V)
RECEPTABLE
SCW-D192
SCW-D152
RS232 I/F
LOAD CELL
95
-D1
TRANSFOMER
SCW
CN6 (40P)
KEYBOARD
DS-782
P02/AN5 O - - NC
P03/AN4 O - - NC
P04/AN3 O - - NC
P05/AN2 O - - NC
P06/AN1 O - - NC
P07/AN0 O EEPCS 93C46 EEPROM CS (Reserved)
P10/K10/AN8 O CBUZZ Buzzer Buzzer Sounder
P11/K11/AN9 O EEPSK 93C46 EEPROM Serial Clock (Reserved)
P12/K12/AN10 O EEPDO 93C46 EEPROM Serial Data Out (Reserved)
P13/K13/AN11 I EEPDI 93C46 EEPROM Serial Data In (Reserved)
P14/TXD0 O CTXD0 3232E RS-232C TXD
P15/RXD0 I CRXD0 3232E RS-232C RXD
P16/CLK0 O CRTS0 3232E RS-232C RTS
P17/TRAIO/INT1 I CCTS0 3232E RS-232C CTS
P20/TRDIOA0 O T1 Keyboard Key Scanning Line
P21/TRDIOB0 O T2 Keyboard Key Scanning Line
P22/TRDIOC0 O T3 Keyboard Key Scanning Line
P23/TRDIOD0 O T4 Keyboard Key Scanning Line
P24/TRDIOA1 O T5 Keyboard Key Scanning Line
P25/TRDIOB1 O T6 Keyboard Key Scanning Line
P26/TRDIOC1 O - - NC
P27/TRDIOD1 O - - NC
P30/TRAO O BTPW BATT-PW Controls battery power
P31/TRBO O BTCHG BATT-CHARGER Controls battery charger
*DS-782only *DS-782only *DS-782only
StE29
(*DS-782)
0 - No 0 - No 0 - No
1 - Yes 1 - Yes 1 - Yes
SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
10 Data transfer protocol of RS-232C *RS type only
0 - No 0 - Allow 0 - 2 bytes
1 - Yes 1 - Inhibit 1 - 4 bytes
13 - 19
For Weight & Measure - (1 4 2)
NOTE: It can work only when the SPAN Switch is on (Enable)
00 - 1 10 - 5 00 - 1/3000 10 - 1/7500
01 - 2 11 - 10 01 - 1/6000 11 - Not used
24 Weight single interval Net / Gross Negative weight display mask
or multi-interval Multi-interval
0000 - 1e 1000 - 9e
0001 - 2e 1001 - 10e
0010 - 3e 1010 - 20e
0011 - 4e 1011 - 30e
0100 - 5e 1100 - 40e
0101 - 6e 1101 - 50e
0110 - 7e 1110 - 60e
0111 - 8e 1111 - 70e
SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0
41 - 47
Status Flag:
Not Fixed Not Price Price Total Price Net Additional
Used to 1 used Base Base Overflow Parity
Bit 7 : Not used. Always 0;.
Bit 6 : Fixed to 1.
Bit 5 : Not used.
Bit 4 and Bit 3 : Price Base. 00 - $/kg, 01 - $/100g, 10 - $/1b, 11 - $/1/41b.
Bit 2 : Total Price Overflow. Set to 1 when total price overflow, 0 when not.
Bit 1 : Net. Set to 1 When tare subtraction is performed, 0 when not.
Bit 0 : Additional parity flag. Set to 1 when additional parity code is added in text, 0 when not.
Weight Condition Flag:
0 1 0 0 0 0 1 0
Weight Condition Flag: 0x42
0 1 0 0 0 0 1 0
By ASCII Code:
0x42 0x42 0x0d 0x30 0x30 0x33 0x2e 0x34 0x35 0x36 0x0d
0x54 0x30 0x30 0x35 0x2e 0x31 0x38 0x34 0x0d 0x0a
0x54 0x30 0x30 0x35 0x2e 0x31 0x38 0x34 0x0d 0x0a
0x54 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x0d 0x0a
PC SIDE SCALE
PC SCALE
No
Ready ?
PC SIDE SCALE
Key Press
[ENQ]
Ready ?
No
No
X Second ?
Yes
PC
[NAK]
End Immediately
No Responds
Time Out (3 Sec)
[ACK]
SCALE
[Text String]
PC
[NAK]
Normal End
PC SIDE SCALE
[ENQ]
PC
[NAK] No
Weighing Mode ?
Yes
No
[NAK] Yes No
X Second ?
Normal End