0% found this document useful (0 votes)
264 views4 pages

Kruss Techdata SDT en PDF

The SDT spinning drop tensiometer provides high-speed, high-resolution measurements of interfacial tension between 10-6 and 2000 mN/m. It features a USB 3.0 camera, LED illumination, temperature control from -10 to 120°C, and automated sample loading and drop creation. The device measures interfacial tension using the Vonnegut and Young-Laplace models and is controlled via an integrated touchscreen panel.

Uploaded by

Travis H
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
264 views4 pages

Kruss Techdata SDT en PDF

The SDT spinning drop tensiometer provides high-speed, high-resolution measurements of interfacial tension between 10-6 and 2000 mN/m. It features a USB 3.0 camera, LED illumination, temperature control from -10 to 120°C, and automated sample loading and drop creation. The device measures interfacial tension using the Vonnegut and Young-Laplace models and is controlled via an integrated touchscreen panel.

Uploaded by

Travis H
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SPINNING DROP TENSIOMETER – SDT

SPECIFICATIONS
Product group specifications SDT
Camera system
Connection USB 3.0
Performance 15 fps at 2560 × 1920 px
Optics
Focus fixed
Zoom 1.4× zoom, fixed
Field of view 6 mm × 4.5 mm
Resolution 2.3 µm
Illumination
Type high power monochromatic LED and stroboscope
Wave length, dominant 469 nm
Field of light 57 mm × 7 mm (D × H)
Sample stage
Tilting ±20°
Resolution 0.1°
Capillary drive
Resolution 0.1 rpm
Long term stability ±1 rpm
Software
ADVANCE spinning drop

Measurement specifications SDT


Spinning drop
Result interfacial tension (IFT)
Range 10-6 to 2000 mN/m
Resolution 10-6 mN/m
Models Vonnegut, Young-Laplace
General specifiations SDT
Sample dimensions
Minimum required sample volume surrounding liquid: 1 mL
drop liquid: 1 to 4 μL
Temperature control
Types electric liquid
Range ambient to 120 °C -10 to 120 °C
Resolution 0.1 °C depending on external circulator
Flow-through thermostat - optional
Temperature controlled measurement
Types internal sensor infrared sensor
Range -10 to 180 °C -10 to 180 °C
Resolution 0.1 °C 0.1 °C
Precision 0.1 °C 0.1 °C
Locations heating element capillary
Housing and peripherals
Camera parking system protecting the camera when not in use
Control panel glass surface with capacitive sensing
Capillary
Septum free filling system for easy sample preparation
Quick lock loading for fast sample exchange
Drop launch mechanism drop creation at the press of a button
Environment
Operating temperature 15 to 30 °C
Humidity without condensation
Instrument dimensions
Footprint 360 mm × 240 mm (W × D)
Height 325 mm
Weight (without accessories) 15 kg
Power supply
Voltage 100 to 240 VAC
Power consumption maximum 250 W
Frequency 50/60 Hz
Interfaces
PC USB3.0
Auxiliary RS232
Circulator quick lock fittings
kruss-scientific.com

Technical changes are reserved. SDT-20180627