Substation Inspection Checklist

[The document is a checklist for inspecting a substation. It contains sections to check the cleanliness and security of the substation, the condition of transformers and feeder pillars, and the status of cables and lines. Key items inspected include fence and gate security, transformer appearance and earthing, fuse condition in feeder pillars, and the condition of cables for signs of damage like burns or cuts.]

Uploaded by

Sum Tin Rung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (4 votes)
5K views2 pages

Substation Inspection Checklist

[The document is a checklist for inspecting a substation. It contains sections to check the cleanliness and security of the substation, the condition of transformers and feeder pillars, and the status of cables and lines. Key items inspected include fence and gate security, transformer appearance and earthing, fuse condition in feeder pillars, and the condition of cables for signs of damage like burns or cuts.]

Uploaded by

Sum Tin Rung
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

SUBSTATION INSPECTION CHECKLIST

BUSINESS UNIT: _______________________________ UNDERTAKING: ___________________________

NAME OF SUBSTATION: __________________________________ DATE: _______________________

SECTION A: SUBSTATION
CLEANLINESS SECURITY SUBSTATIO INCOMER CABLE LIGHTNING LOAD READING/TF
Bushy Fence N FLOOR Burnt socket ARRESTERS PARTICULARS
☐ Yes ☐ No ☐ Granite/Grav R ☐ Y ☐ B ☐ N☐ Present
Slightly Bushy Gate Properly buried R- Make:
Yes ☐ No
☐ el
Yes ☐ No ☐ Yes ☐ No ☐ ☐
Refuse dump Y- S/N:
Lockable ☐ Yes ☐ No Substandard Disconnecte

OK Locked ☐ Cable d/Absent B- Year:

☐ R☐Y☐ B☐N R☐Y☐ B
N-

SECTION B: TRANSFORMER
APPEARANCE CONSERVATOR SILICAL GEL COLOUR TRANSFORMER EARTHING
Oil leakage Blue ☐ PLINTH Yes NO
TANK
Yes ☐ No ☐ Blue-Black ☐ Ok ☐
Yes ☐ No ☐ Disc.
Cracked bushings Too low ☐
White ☐
SILICAL GEL BOTTLE
Yes ☐ No ☐ Sinking ☐ Neutral ☐ ☐ ☐
Yes ☐ No ☐ Pink ☐
No plinth ☐
Transformer tank F/P body
Broken ☐ Others ☐ ☐ ☐ ☐
Ok ☐ Damaged ☐
ABNORMAL TEMP. TF body ☐ ☐ ☐
Yes ☐ No ☐
L/A ☐ ☐ ☐

SECTION C: FEEDER PILLAR


APPEARANCE TYPE OF F/P LV FUSE UNIT I UNIT II UNIT III UNIT IV
Door present UNIT Fuse cut Badly Burnt Badly Burnt ☐ Badly Burnt Badly Burnt ☐
Yes ☐ No ☐ Yes ☐ No ☐ ☐ Slightly Burnt ☐ Slightly Burnt ☐
Door closed Straight ☐ Standard fuse Slightly Burnt ☐ Slightly Burnt Ok ☐
☐ Ok ☐ ☐
Yes ☐ No ☐ Single ☐ Yes ☐ No
Ok Ok
Falling F/P ☐ HRC fuses ☐
☐ ☐
Yes ☐ No ☐ HRC fuses

HRC fuses HRC fuses ☐

SECTION D: LINE & OTHERS


HT D-FUSE UPRISER CABLE I UPRISER CABLE II UPRISER CABLE III UPRISER CABLE IV

LINE/CABLE ASSEMBLY Burnt Socket Burnt Socket Burnt Socket Burnt Socket
HT line taps D-fuse R☐Y☐ B☐N R☐Y☐ B☐N R☐Y☐ B☐N R☐Y☐ B☐N☐
Yes ☐ Assembly ☐ Weak/Cut ☐ Weak/Cut ☐ Weak/Cut Weak/Cut Jumper
No ☐ Yes ☐ Jumper Jumper Jumper Yes ☐ No ☐
XLPE Cable No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Line taps
Punctured ☐ Bypassed Line taps Line taps Line taps Yes ☐ No ☐
Burnt lug ☐ R☐ Y☐ B Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐
Ok ☐ ☐

Findings/Action_taken:_________________________________________________________________________________________________

____________________________________________________________________________________________________

Recommendation(s):___________________________________________________________________________________________________

___________________________________________________________________________________________________

Inspected by: __________________________________________ Sign: _____________________