Bracket Connection

This document summarizes the design of a bracket connection using bolts. It calculates: 1) The number of bolts required based on the factored load, eccentricity, moment, bolt properties, and shear capacity. Four bolts are required in a single row. 2) Additional details of the bolt configuration including pitch, edge distance, plate thickness. 3) The bearing and tension capacities of the bolts are then calculated and checked against design values. 4) The final summary confirms the design is satisfactory based on checking the combined shear and tension is less than 1.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
281 views4 pages

Bracket Connection

This document summarizes the design of a bracket connection using bolts. It calculates: 1) The number of bolts required based on the factored load, eccentricity, moment, bolt properties, and shear capacity. Four bolts are required in a single row. 2) Additional details of the bolt configuration including pitch, edge distance, plate thickness. 3) The bearing and tension capacities of the bolts are then calculated and checked against design values. 4) The final summary confirms the design is satisfactory based on checking the combined shear and tension is less than 1.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

DESIGN STRENGTH AND BRACKET CONNECTION

bolt details

FACTORED LOAD = 225000 N


ECCENTRICITY (E) = 300 mm
MOMENT (M) = 67500000 N

Grade of bolt = 4.6

Diameter of bolt = 24 mm
Gross area of the bolt Asb = 452.448 mm2

Net area of bolts = 352.9094 mm2

Diameter of bolt hole = 26 mm

Ultimate strenght (fub) = 400 N/mm2

no of shear planes 1
intersecpting threads(nn) =

Partial safety factor(ɤmb) = 1.25


Partial safety factor(ɤmo) = 1.1
Ultimate strenght (fu) = 410 N/mm2
no of shear planes non 0
intersecpting threads(nn) =
Yeild strenght = 250 N/mm2

shear capacity of bolts = 65200.8 N

pitch of the bolt (P) = 60 mm


edge distance of the bolt (e) = 39 mm
Thickness of thinner plate = 8 mm
0.8 0.5 1.025 1

kb = 0.5

bearing capacity of bolts = 81747.7 N

no of bolts required = 4.0

no. Of bolts required in single row = 8.0

no. Of bolts required in two 16.0


rows (total ) =
no of spaces = 7.0

Total depth of the bracket 498.0


plate = mm
length of connection = 459.0 mm

Neutral axis at h/7 = 65.6 mm

tension capacity of bolts = 127047.3984 N ≤

Designed tension capacity = 101637.9 N/mm2

1259.1 258942.5 SUMMATION

MOMENT M' = 55667044.4 N-M

32338.9
Tensile Force in extreme bolt = N

shear force in extreme bolt = 14062.5 N

check

Combined sear and tension = 0.5 ≤ 1

hence safe
IS 800:2007 clause 10.3.3

Least of the values is kb

IS 800:2007 clause 10.3.4

bolts required considering effect of shear and bearing

bolts required considering effect of shear and bearing and tension


128536.4

HENCE OK

SUMMATION

You might also like