ABSTRACT
TSP (dust) constitute one of major class of air polution. Particulates have a variety of
shapes and size, and can be emitted from many different sources such as natural
emissions or human activity like using of motor vehicle. This day many building like
offices or department stores had been founded using basement parking for efficiency of
space and time. Mall X Semarang is one of the biggest department store in Semarang and
has a basement parking, numbers of motor vehicle enter this parking site in a day emitted
dust (TSP) which is can irritate the health both employee and customer of Mall X. Thus
research was aiming at finding out and analysing amount of dust concentration (TSP) on
either basement or upper ground of Mall X, and analysing the risk from related pollutant
for the employee of Mall X Semarang. This research consist of identification dust
concentration, compares concentration between basement parking and upper ground
parking, and analyze questionnaire statistic test to find out the affect of employee. The
highest concentration was founded on basement parking is 323.351 µg/Nm3 and it means
this concentration exceeds to air standart that maximal concentration for 230 µg/Nm3.
pengelihatan
SARAN
1. Bagi pihak Mall X Semarang,
KESIMPULAN perlu diadakan sistem rolling
1. Berdasarkan hasil terutama untuk karyawan parkir di
pengukuran debu (TSP) tertinggi di areal basement guna meminimalisir
Mall X Semarang ialah sebesar waktu karyawan untuk berada di
323.351 µg/m3 di area basement areal basement.
pada tanggal 20 September dan 2. Perlu diberlakukan
3
sebesar 208.430 µg/m di areal upper penggunaan safety tools seperti
ground pada tanggal 9 September. masker, untuk mengurangi dampak
Kedua hasil penelitian ini melewati cemaran debu yang masuk ke areal
nilai batas ambang baku mutu yang pernafasan, serta perlu diadakan
ditetapkan oleh SK Gubernur Jateng medical check up bagi karyawan.
No. 8 Tahun 2001 mengenai baku 3. Hendaknya pihak Mall X
mutu standar TSP sebesar 230 µg/m3 Semarang melakukan pematauan
2. Dengan melakukan analisis kualitas udara di areal basement
statistik baik untuk konsentrasi debu secara rutin,
maupun kuisioner, didapatkan nilai
korelasi antara lama tinggal dengan Daftar Pustaka
frekuensi sakit sebesar 0.153, dengan Adiwibowo, Retnasih Supraba. 2008.
gejala sesak 0.450, dan dengan Faktor Keselamatan dan Keamanan
gangguan penglihatan sebesar 0.280. Dalam Desain Bangunan Parkir di
Ketiga hubungan antar variabel ini Jakarta. Fakultas Teknik. Depok :
memiliki nilai yang positif yang Jakarta
berarti semakin lama seorang
karyawan berada di areal basement
Anonim, 2001. Baku Mutu Udara Hidayat, Syaiful dkk. 2012.
Ambien di Propinsi Jawa Tengah. Pengaruh Polusi Udara dalam
Ruangan Terhadap Paru. Continuing
Arief, Latar Muhammad. 2013.
Medical Education. Universitas
Perencanaan Sistem Ventilasi
Indonesia : Jakarta
Pengenceran Udara Dengan
Menggunakan ASHARE Standar. Leili. M, K. Naddafi et al. 2008. The
Jakarta Study of TSP and PM10
Concentration and Their Heavy
Badan Pengelolaan Lingkungan
Metal Content in Central Area of
Hidup. 2009.
Tehran. Springerlink : Iran
http://www.bplhdjabar.go.id/,
diunduh tanggal 1 Juli 2013. Oktora, Bunga. 2008. Hubungan
Pencemaran Udara Oleh Partikulat. Antara Kualitas Fisik Udara Dalam
Provinsi Jawa Barat. Ruang (Suhu dan Kelembaban
Relatif) Dengan Kejadian Sick
Badan Standarisasi Nasional. 2001.
Building Syndrome (SBS) Pada
Tata Cara Perancangan Sistem
Pegawai Kantor Pusat Perusahaan
Ventilasi dan Pengkondisian Udara
Jasa Konstruksi X di Jakarta Timur
pada Bangunan Gedung. SNI 03-
Tahun 2008. Fakultas Kesehatan
6572-2001
Masyarakat. Depok : Universitas
Badan Standarisasi Nasional. 2005. Indonesia
Cara Uji Parikel Tersuspensi Total
Prasasti, Corie Indria, J. Mukono,
Menggunakan Peralatan High
dkk. 2005. Pengaruh Kualitas Udara
Volume Air Sampler (HVAS) dengan
Dalam Ruangan Ber-AC Terhadap
Metoda Gravimetri. SNI 19-7119.3-
gangguan Kesehatan. Fakultas
2005
Kesehatan Masyarakat. Surabaya :
Cooper, C. David and F.C. Alley. Universitas Airlangga
1986. Air PollutionControl : A
Satriyo, Saputro. 2008. Studi Kondisi
Design Approach. PWS Engineering
Kimiawi Penyebaran Pb, Debu, dan
: Boston.
Kebisingan Kota Jakarta. Jakarta :
Lembaga Penelitian Ubhara Jaya