Hicms Eng PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

2016.

01

HiCMS
Certificate of conformity to
international standards for
industrial software

Hyosung intelligent
Condition Monitoring System

www.hyosungpni.com Global Top Energy, Machinery & Plant Solution Provider

HEAD OFFICE 119, Mapo-daero, Mapo-gu, Seoul, Korea (04144) TEL : 82-2-707-7000
CHANGWON PLANT 171, Yeondeok-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, Korea (51529) TEL : 82-55-268-8000

· Products (models) listed in this catalogue are subject to production cessation and specification changes without notice. Please be sure to check their availability before you purchase.
· Do not disassemble or repair the product on your own for maintenance/inspection purposes. To ensure your safety, please contact our technicians.
About HYOSUNG 02 Sustainability
Our sustainability principles are the backbone of the way
we design and manufacture products
Quality Assurance
Hyosung strives for excellence. We believe excellence can only be achieved through absolute quality and value for customers. In order
to create quality products, we believe that all of the actions of every single employee must be focused in the highest level of quality. In
order to achieve such levels, we have implemented a quality assurance policy and programs that make our philosophy into a reality.
Our Quality Assurance Policy was founded based on the management policy of the president and meets the demands of ISO 9001.
As a globally active company, we are committed to comprehensive and quality management through three quality strategies: quality
management system, customer‐focused management system, and concentration on core competencies.
Hyosung Power & Industrial Systems PG is a division under Hyosung which consists of The comprehensive quality management system ensures that we completely comply with all compliances and applicable legislation,
codes, and standards in addition to implementing efficient operation of our management resources to eliminate unnecessary waste.
seven performance groups(PGs). In addition to establishing itself as a world-class Our customer‐focused management system clarifies and simplifies our first priority which is customer satisfaction. All of our work is
manufacturer of electrical equipments, green technology and industrial machineries, aimed to exceed customer needs and provide exceptional value through quality standards, flexibility, and innovation.
Hyosung is also the largest producer of tire cords and spandex in the global market and Finally, we concentrate on our core competencies for strict quality control and continual improvement which provides quality products
the second largest supplier of ATMs in the USA. and cost‐saving to our clients via advancement in technical capacity and technological innovation.
We implement our policy via a Quality Management Team manages research laboratories, including the Measurement Standard
Laboratory, the Chemical Analysis Laboratory and the Material Analysis Laboratory to maintain a strict control over quality.

Environment Protection Policy


01 Our Business Hyosung understands the impact of Hyosung’s activities in the environment and works to protect the environment from pollution,
manages the environmental impacts of Hyosung’s products and technologies, and prevents future pollution and harmful effects in the
environment by investing in environmentally‐friendly products and solutions.
Based on this eco‐philosophy of shared responsibility, Hyosung has implemented a comprehensive environmental protection program
Brief introduction of Hyosung Power & Industrial Systems that aims to minimize our impact on the environment and conserve resources. Our environmental policy fulfils all requirements of the
ISO 14001.

Hyosung Power & Industrial Systems


Performance Group
Hyosung Power & Industrial Systems Performance Group(PG), a comprehensive energy solution provider, boasts world-leading
technology in the global power industry and has secured a competitive capability on par with that of top competitors in transformers,
switchgears, motors, generators, gear units, industrial machineries, industrial pumps, and wind energy business.
With globalization as one of our top priorities, we have achieved outstanding increase in sales over the past few years thanks to the
03 R&D
enhancement in Hyosung’s quality, technology, and brand recognition among overseas clients, which include North America, Europe,
the Middle East, and Asia. We expect such robust performance, marked by an increasing number of orders from the overseas market, Inspiring innovation, creation and expertise
to continue in the future.
Hyosung R&D Center identifies innovation, creation, and expertise as core value, and concentrates on world class R&D activities in the
At the heart of our capability to grow as a comprehensive energy solution provider is our global organization structure. Hyosung Power
21st century with a philosophy aspiring after customer satisfaction, quality priority, and performance orientation. Hyosung pursues to
& Industrial Systems PG is divided into four business areas or performance units(PU), depending on the types of flagship products :
be the world’s best company in the field of heavy electrical machinery, industrial & electrical electronics engineering, and energy
Power Systems PU, Industrial Machinery PU, HYOSUNG GOODSPRINGS PU, and the Wind Energy Business Division.
system. Ever since establishment in 1978, R&D Center had led the development of domestic technology. Along with the Anyang and
Changwon labs, the group has endeavored to produce core technology and world‐class products in the areas of heavy electrical
machinery, energy system, electrical electronics engineering, and industrial automation system.
Power Systems Performance Unit
Hyosung’s Power Systems PU provides a full spectrum of power generation, transmission, and distribution services, from design and
engineering to the maintenance of equipment. Power System PU has been building up on cutting-edge information technology
Research Areas
resources and developing substation automation systems, such as power monitor and control systems, and early detection and Hyosung R&D Center engages in the activities in the field of energy system, solution & service, applied electrical and electronic
prevention systems. technology, basic core technology, technology of improved reliability, core components, and new materials.
Such vast product assortment and technical know-how is based on our product development history. In 1992, Hyosung was the first
in Korea, and the sixth in the world, to develop a 765kV ultra-high voltage (UHV) transformer, and, in 1999, was the first in the world to Energy System Basic Core Technology
manufacture the 2-breaker 800kV gas insulated switchgear (GIS). Those technological achievements gave Hyosung world-wide • Renewable energy • F ortified technology in structural dynamics,
recognition as one of the global major manufacturers. (wind system, wind turbine, wind PCS, solar system, PV PCS, electromagnetics, heat transfer analysis, etc.
The Power systems PU is continuously striving to secure competitiveness in every aspect of quality, technology, sales, services, and fuel cell, co‐generation) • Skills for system simulation, analysis and evaluation
• Electric Vehicle (EV charger, EV motor) • Business support technology
management, in order to satisfy customer needs globally and become a top-tier company in the world by providing customers with the
best quality products and services in the power systems sector.
Solution & Service Technology with Improved Reliability
• Power facility diagnosis algorithm and system • Test data analysis and testing facility
• Power facility lifecycle evaluation system • Analysis of lifecycle and cause of error
• Service solution for remote diagnosis for prevention • Reliability assessment (environment‐friendliness, durability,
long‐term degradation, and more)
Applied Electrical & Electronic Technology
Power conversion system Core Components and New Materials
HiCMS (Hyosung intelligent Condition Monitoring System)

• Flexible AC transmission system and high voltage direct current • Organic and inorganic insulation materials
• Power quality solution • Silicon forming technology
• Intelligent sensor
(facility diagnosis, CT, PT, VT, LA, and more)
CONTENTS
02 Our Business 03 Sustainability / R&D 04 Overview of HiCMS Series 06 GIS Monitoring & Diagnosis Solution
12 Transformer Monitoring & Diagnosis Solution 19 Total Integrated Monitoring Solution 21 On-site Inspection Service 22 Global Network
Overview of HiCMS Series
GIS Condition Monitoring Solution Transformer Condition Monitoring Solution

• Monitor UHF PD, SF6 Gas density, • Monitor DGA, PD, OLTC,
Total CB operation and LA condition Total WTI/OTI, Fan/Pump
Monitoring • Provide accurate diagnosis Monitoring condition, hot spot etc.

System result and alarm


System • Provide accurate
diagnosis result and alarm
GM-3000 TM-2000 • Monitor 8 critical gases
On-line • Diagnosis based
DGA on unique algorithm
• Rapid and easy System
Portable
TM-200
application on-site
PDM • Reliable external
Device noise elimination

GM-100

• Cost effective • High sensitive


Entry on-line PDM On-line on-line PDM solution
Level PDM • Compact and UHF PDM • Location
System easy installation
System estimation of PD

GM-500 TM-1000

• High sensitive • Rapid and easy


On-line on-line PDM solution Portable application on-site
UHF PDM • Advanced analysis PDM • Location estimation of PD
System algorithm
Device
GM-4000 TM-100

I
04 05 HiCMS Hyosung intelligent Condition Monitoring System
GIS Monitoring & Diagnosis Solution
On-line GIS Total Monitoring System Components
HiCMS GM-3000 HMI
UHF PD | Lightning Arrester Degradation Monitoring | SF6 Gas Density | Operating Characteristics of CB • HMI is an interface display where various pieces of information obtained
from the field is transmitted via communication with the station
controller; various data and trends are displayed; obtained information is
Items Specification Note
categorized into databases; equipment condition/status is diagnosed
Operating Temperature -25 ~ 60℃ via diagnostic algorithms; equipment service life is forecast and
monitoring schedules are proposed based on data analysis;
Operating Humidity 10 ~ 90% malfunctioning areas are indicated during an accident; and solutions to
eliminate failure are suggested. HMI is the state-of-the-art diagnostic
Number of PD Input Channel 9ch solution that combines the latest computing and digital technologies.
Detection Frequency Bandwidth 100~2,000MHz

Detection Sensitivity Less than 1pC

Calibration Signal 1GHz, -50dBm Watch dog for RF module

Analog : 9ch, 4 ~ 20mA Gas density and Station Controller (Main Unit)
Analog / Digital Module
Digital : 4ch, dry contact CB monitoring
• The station controller receives equipment condition-monitoring data
SIO Module RS-485, 4ch LA monitoring from the DAU (Data Acquisition Unit) which compiles raw data measured
from the sensors installed in the field, and transmits the information to
Size 19 inch / 4U upper-tier HMI through the internal communications controller.
» Offers system redundancy
» Provides easy-to-use interface with other facilities, through multi-protocols

• The station controller converts and processes the data collected from
the communication controller and transmits them to upper-tier HMI.
It also analyzes the control instructions from upper tiers and delivers
System Configuration them to lower-tier DAU.
»Configures individual communication channels between lower-tier systems
» Enables peer-to-peer communication between upper-tier and lower-tier
systems, respectively, and allows self diagnosis
» Controls communication error (critical data backup and restoration)
UHF PD
Sensor » Connects to Ethernet (10/100 Mbps) and serial devices (RS-232/422/485)
» Supports multi-protocols (e.g., DNP 3.0, Modbus, Modbus Tcp)
Equipment » Allows system database downloading from upper-tier hosts
Fault Diagnosis
HMI
DAU for GIS » Offers system stability through redundancy
CB Operation » IEC 61850 Protocol is applicable
Sensor

Operating 100Mbps
Workstation Fiber Switched Ethernet

• IEC 61850
• DNP
GDT
Sensor
DAU (Local Unit)
• Modbus
• PD : 3/6/9ch • Based on diagnostic algorithms optimized for the transformer/GIS, DAU
Web Server • ADI : AI 9ch, DI 4ch/board
• AI : 8ch/board attains data from various sensors and delivers the information needed
• SIO(RS-485) : 4ch/board for alarm and diagnosis.
* Max 6 board is applicable Lightning
Arrester Sensor » Adopts high-performance DSP chip and conducts high-speed real-time A/D
conversion
» Stores data for 24 hours during a communication failure
» Capable of optic and serial (RS-232/422/485) communication
» Detects problems and issues alarms in accordance with its internal algorithm
» Capable of integration monitoring of various sensors is possible
• PD : 3/6/9ch
• ADI : AI 6ch, DI 6ch/board
I
06 07 HiCMS Hyosung intelligent Condition Monitoring System • AI : 8ch/board
• SIO(RS-485) : 4ch/board
* Max 6 board is applicable
Monitoring and Diagnosis Items High-end Level On-line UHF PD Monitoring System for GIS
Partial Discharge HiCMS GM-4000
• Through the analyzer installed in the field, UHF signal, generated The Hyosung HiCMS GM-4000 is a on-line continuous
when partial discharge occurs in GIS, is captured, and the PD
magnitude (pC), cause, location, tendency, and risk are analyzed to
monitoring system for assessing the insulation condition
provide reasonable data on the operating condition. of GIS. This PDM shall continuously detect and record
• Monitoring time and service life can be forecast, and a warning the PD signals generated by all PDs in the GIS. Using this
(message) is issued and monitoring instructions are provided when new system, operator can prevent unexpected failure of
the set limits are reached.
GIS.
• Features such as PRPD (Φ-q-n), PRPS (Φ-q-t), and noise masking
are offered selectively.
• External noise sensor for noise elimination (Optional)

Lightning Arrester Degradation Monitoring


• The total leakage current and 3rd harmonic leakage current of the
lightning arrester are monitored constantly, and at the same time the
trend can be identified.
• When the threshold value are reached, a warning (message) is
issued, and the information on monitoring time and remaining Features
service life is provided.
• High sensitive PD monitoring solution based on UHF PD detection technique
• Continuous and real time monitoring of PD signals
• Real PD discrimination is possible using noise elimination technique
• Advanced algorithm provide the precise analysis
SF6 Gas Density
• Rugged and reliable for the external surge on site
• Using gas density sensors, the pressure of SF6 gas
(GIS insulation medium) is monitored, and a sensor is mounted
in each gas section to monitor the gas-tightness.
• During internal flash over, though very rare, the instantaneous rise in
pressure is identified to locate where failure has occurred and to Specification
allow prompt maintenance.
Item Specification
Detection frequency bandwidth 100 ~ 2,000MHz

Input range -80 ~ -20 dBm


Operating Characteristics of CB No. of Input channel 3Ch / 6Ch / 9Ch

The measurement of the current and operating time of trip coil, the Sensor type Internal and external type sensor
current and operating time of close coil, the operating time of
mechanical aux. contact and CB traveling curve are measured to find Detection sensitivity Less than 1pC
if there is any problem with the control circuit, control pressure or CB,
Operating temp. -30 ~ +80℃
if there is any delayed operation in the hook/pilot/main valve, any
problems with CB due to abrasion/deformation. Case dimension 400 x 500 x 210mm

IP rating IP 66

I
08 09 HiCMS Hyosung intelligent Condition Monitoring System
Entry-level On-line UHF PD Monitoring System for GIS Portable UHF PD Monitoring System for GIS
HiCMS GM-500 HiCMS GM-100
The HiCMS GM500 (Smart sensor) developed by The HiCMS GM100 is a versatile, portable UHF partial
HYOSUNG continuously monitors the power equipment discharge (PD) analyzer. This device detects and records
and automatically discriminates PD cause using UHF PD the UHF PD signal generated by defects in the GIS. Using
detection techniques. This monitoring device is very the internal and external type sensors, it will provide the
compact and has competitive price because it is an all-in- early warning of unexpected failure before complete
one system composed of PD sensor, noise sensor, RF breakdown occurs.
circuit, signal processing H/W and communication
module. This solution is aimed at providing reliable power
equipment operation and reducing maintenance cost by
unexpected failure.

Smart Sensor Main Unit


Features Optic Features
Cable HMI

• High sensitivity and excellent reliability • Partial Discharge(pC) measurement for each compartment of GIS
• Robustness to external noise using noise gating technology • Location estimation of Partial Discharge position
• Has Ultra wide-band characteristics • Analysis algorithm to classify both PD and background noise.
( Free moving particles, spacer crack, void in insulator,
floating electrode, Protrusion, Cellular phone Noise, etc..)
• Using noise masking technology, reliable diagnosis is possible.
• Risk assessment of Partial Discharge (5step Guidance Alarm)
• Fully protected against surge and transient overvoltage
DB Server

<System configuration>
Specification
Specification
Item Specification Note
Item Specification
Input frequency range 100MHz ~ 2,000MHz
Detection bandwidth 100 ~ 2,000MHz
Input signal level -80 dBm ~ -20 dBm
No. of Input channel 3 or 9 Channel
Minimum sensitivity Less than 1pC
Sensor type Internal and external type sensor
Self test pulse generator 1GHz, -50dBm Watch dog for RF module
Supply voltage 100 ~ 230VAC / 50 ~ 60Hz
1ch : PD detection
Number of CH 2ch/Unit
Synchronization PT signal or internal
2ch : Noise detection
Operating temperature -30℃ ~ 80℃ Operation temp. -10 ~ 50℃

Operating humidity 30% ~ 95% Weight about 20kg

IP rating IP 66 Case dimension 538 x 406 x 211mm

I
10 11 HiCMS Hyosung intelligent Condition Monitoring System
Transformer Monitoring & Diagnosis Solution
On-line Transformer Total Monitoring System Monitoring and Diagnosis Items
HiCMS TM-2000 Transformer Oil Degradation (Dissolved Gas)
• Perform real-time measurement of the amount of H2, CO, C2H2 and
Main Views for the System C2H4 etc., generated in the transformer tank
• Issues an alarm when the amount of dissolved gas exceeds the set
limits or shows an abrupt change
• P erform self-diagnosis and issues alarms in the event of sensor
failure

Hot Spot Monitoring


For transformer oil degradation For transformer oil temperature For cooling fan/pump motor For web-based transformer • Robust fiber optic temperature sensors which were installed on
(dissolved gas) measurement measurement current measurement status measurement insulation spacer or surface of coil provide the exact temperature
» Views gas‐specific history and » Constantly monitors transformer oil » Indicates operating current and time » Monitors oil temperature, dissolved of hot spot directly
tendency temperature for fan motors gas and other parameters remotely by
» Views on‐site installation » Compares differences between » Shows fan motor operation status using internet browsers • Using the real time temperature, efficient transformer operation
» Displays dissolved‐oil alarms/events outside and transformer oil » Displays motor current‐related events » Conducts real‐time comprehensive is possible
temperatures for monitoring purposes analysis of trends and history
» Follows trends in temperature on a

On-line Bushing Monitor


daily/weekly/monthly basis

• Bushing monitoring system provide real time information of bushing


System Configuration condition
• Install coupling units on bushing of power transformer in order to
measure PD activity and capacitance

Dissolved
Gas Analyzer
OLTC Monitoring
• Indicates the present value and trend for contact wear, torque,
Hot Spot OLTC temperature, and operating frequency
Monitoring
Equipment
• Issues alarms and presents inspection messages when the
Fault Diagnosis DAU for MTR threshold value are exceeded
HMI

Bushing
Monitor

Operating 100Mbps
Transformer Oil / Winding Temperature
Workstation Fiber Switched Ethernet
Indicates for each tank the present value and trend for top oil
• IEC 61850 OLTC Sensor temperature, ambient temperature, load current, average oil
• DNP
• Modbus
temperature increase, and winding Hot-spot temperature
• DI : 8ch/board
Web Server • AI : 8ch/board
• SIO(RS-485) : 4ch/board
* Max 6 board is applicable
WTI/OTI

Cooling Fan / Pump Motor Operating Condition

Fan/Pump/
Diagnoses the operating condition of transformer fans and pumps and
※MTR = Main Transformer Motor the operating status of current fans and pumps, issues alarms when
Monitoring
Sensor current exceeds the threshold value, and operates the TM-2000
system to inform the operator about what has caused the problem
(e.g., power failure, motor failure, overload)

I
12 13 HiCMS Hyosung intelligent Condition Monitoring System
On-line UHF PD Monitoring System for Transformer
HiCMS TM-1000
The HiCMS TM1000 is a monitoring system for assessing
the condition of transformers in the field. The system is
an on-line partial discharge (PD) monitoring system for
power transformers. By monitoring the in-service partial
discharge, the insulation performance can be reliability <UHF PD sensor>
assessed over time and proper maintenance can be
taken before a failure occurs.
UHF PD Sensor Specification

Item Specification
Detection bandwidth 300 ~ 1,500MHz

<DAU> Sensor type Monopole type sensor

Sensor install position Drain valve

Sensitivity 49.8 mV at 50pC

Withstand pressure
Features 0.5 Mpa (5.098 kgf/cm2)

Maximum temperature 120℃


• High sensitive PD detection for transformer based on the UHF PD
measurement technique
• Location estimation of Partial Discharge position in transformer
using the time of flight method. System Configuration
• Analysis algorithm to classify both PD and background noise.
• Using noise masking technology, reliable diagnosis is possible. Local Unit Main Unit
• Fully protected against surge and transient overvoltage

PD Analyzer
GPS
GPS Signal

Coaxial Cable Monitor


Digital Process
<HMI> Unit

DAU Specification UPS Signal


PD Analyzer UPS

Server PC
Item Specification Coaxial Cable
Ethernet
Detection frequency bandwidth 300 ~ 1,500MHz

Input signal level -85 ~ 0dBm (Optical) Optical /


Ethernet
Optical Fiber Cable Ethernet HUB
Detection sensitivity Less than 1pC PD Analyzer
Client PC

No. of Input channel 12ch Coaxial Cable


Printer

Operation temp. -25 ~ 60℃

I
14 15 HiCMS Hyosung intelligent Condition Monitoring System
On-line DGA System for Transformer Technical Specification Environmental

HiCMS TM-200 PARAMETER


(Compound)
VALUES
(Measurement range)
PARAMETER
(Compound)
VALUES
(Measurement range)
The HiCMS TM200 is an on-line DGA monitoring system Hydrogen (H2) 5 - 5,000 ppm Temperature
-40 to 55°C (-40 to 131°F)
Range
for assessing the condition of transformers in the site. Carbon
2 - 50,000 ppm
Monoxide (CO) Oil Temperature
DGA (dissolved gas analysis) of transformer oil is the best Range
-40 to 120°C (-40 to 248°F)
Carbon Dioxide
indicator of a transformer’s overall condition. The HiCMS (CO2)
20 - 50,000 ppm
90 - 250 VAC; 47 - 63Hz;
Power Supply
TM200 base on Hyosung’s new analysis algorithm Methane (CH4) 2 - 50,000 ppm
150W (8A max)

provides the most reliable DGA condition assessment Acetylene (C2H2) 0.5 - 50,000 ppm
Operating
10 - 95% RH non-condensing
Humidity
available. Ethane (C2H6) 2 - 50,000 ppm
Enclosure IP55
Ethylene (C2H4) 2 - 50,000 ppm
Water (H2O) 0-100% RS (given in ppm) Weight 78 kg (172 lbs)
Oxygen (O2) 150 - 50,000 ppm, ±10% Single Phase NO and NC provided, 5A 250
Nitrogen (N2) 10 – 130,000 ppm, ±15% Alarm Relays VAC, 5A 30 VDC.
1± 5% or ± LDL Measurement Variable - 1 per hour
Accuracy**
Features (whichever is greater) Frequency to 1 every 4 weeks
** Accuracy quoted is the accuracy of the detectors during calibration.
Prevent Transformer Failures Lower Costs Through CBM*
Continuous trending of key fault gases gives early and immediate Only comprehensive on-line monitoring can provide the information
notification of incipient faults that can lead to transformer failure. that enables continuous transformer condition assessment.
It provides the important and timely information you need to Comprehensive analysis of key fault gases and other key
maintain the reliability of your transformer fleet. parameters enables intelligent management of transformers,
Minimal Maintenance
extending their useful life. System Configuration
CBM* (Condition Based Maintenance)
(If Transfix used) No carrier gases or calibration gases required.
It reduces running costs and site visits. Gas Analysis
Also when installation performed, no outages required which Oil sampling is continuous and gas analysis intervals are Sensor Servers Clients
reduces expense and inconvenience for user. user-selectable from 1 hours to 4 weeks. All data is date and time
stamped and up to two years of data is stored in memory.
Communications
Automatic schedule acceleration when rate of change alarm limit Substation 1
Two separate channels for remote communications, local USB TCP/IP
is exceeded (Default : 1 hr). Networks
connection and Ethernet connection provided. Communication
protocols supported include MODBUS®, MODBUS/TCP, DNP3.0, DGA Software Clients
IEC61850®. Modules available for connection via RS232, RS485, HiCMS TM 2000 software and services offer simple yet powerful
Ethernet, PSTN modem and GSM or CDMA wireless modems. analytical tools for transformer monitor control, data presentation Shared
and analysis as well as management functions. The application Memory Clients
Hyosung DGA Algorithms I/O Driver
software, included with each transformer monitor product, is used
• Advanced Gas Ratio Method : Optimum gas ratios selected for
to locally or remotely control, retrieve, store, and view data.
improvement of diagnosis accuracy and Optimum gas-ratio Clients
combinations for improvement of diagnosis accuracy. DGA Algorithm Accuracy
• Advanced % Gas Methods : Fault diagnosis by four % gases Regarding IEC TC 10 / IEEE Data 122 Case,
App Server
and Fault diagnosis by two of four % gases. Test results of Hyosung and International DGA algorithms are below

Diagnostic Unresolved Wrong Accuracy TCP/IP


Algorithm Diagnosis (%) Diagnosis (%) Rates (%)
Hyosung Hyosung 0.0 3.2 96.8
Key Gas 3.2 38.7 58.1
Gas ratio Dornenburg 15.1 1.1 83.9 DB Server
TCP/IP
methods Rogers 37.6 17.2 45.2
IEC 17.2 16.1 66.7
Duval Triangle 0.0 12.9 87.1 Clients
Diag. Code (Japan) 8.6 48.4 43.0
Substation 2
Hyosung
% gas
Clients
methods Substation n

I
16 17 HiCMS Hyosung intelligent Condition Monitoring System
Total Integrated Monitoring Solution
Portable UHF PD Monitoring System for Transformer Total Integrated Condition Monitoring Solution with Web & Mobile
HiCMS TM-100 HiCMS Smart HMI
The HiCMS TM100 is the portable UHF PD analyzer The HiCMS SmartHMI is a monitoring system for
suitable for monitoring of PD activity in transformer. This assessing the condition of transformers, GIS, Cables,
device detects and records the UHF PD signal generated Switchgears in the substation. The web and mobile
by defects in the transformer without outage. Using the access are available within substation network.
Hyosung’s unique algorithm, TM 100 determine the This total integrated solution brings about the efficient
defect cause and location, then it will provide the early enhancement not only in the operation of substation but
warning of unexpected failure before complete breakdown also in cost-saving of maintenance.
occurs.

Features
• Partial Discharge(PC) measurement for each compartment of
transformer.
• Analysis algorithm to classify both PD and background noise.
• Location estimation of Partial Discharge position in transformer
using the time of flight method. Features
• Convenient and handy through light weight, compact size and
battery operation. Highly Integrated Monitoring Solution Web & Mobile Access
• Fully protected against surge and transient overvoltage Smart HMI system provides total monitoring solution with all kind This system complies with the state-of-art mobile and web
of power apparatus including transformer, GIS, Cable and technology. The operators are able to access effects on the
Switchgear in the substation for the operators and asset condition of their assets immediately and remotely, anywhere and
managers. The existing condition monitoring system for each anytime with their smart phone(android or i-phone) or PC web-
Specification asset must be installed before SmartHMI. SmartHMI is the browser. It is the most effective in providing visibility and insight into
the substation asset management
integrated software of all existing condition monitoring system. It is
“One solution for All equipment”
Maximized Network Security
Item Specification Condition Based Maintenance To prevent unauthorized access, misuse or modification of
Given its online diagnostic capabilities, and ability to set alarms, substation network, Network Security is the most crucial aspect.
Detection bandwidth 300 ~ 1,500MHz the system can provide advanced notification of impending failure. With user authentication process, strong firewall and network
Input signal level -85 ~ 0dBm Thus better decisions can be made earlier. The operators have all separation are the minimum requirements of SmartHMI.
their assets and the entire system constantly in one view of real- Communication between SmartHMI Server and client(mobile
No. of Input channel 4ch time monitoring base. phone apps or Web-browser of operator’s PC) using substation
network is encrypted to maintain security.
Sensor type Monolpole type sensor Advanced Analysis Tools
Using internationally recognized algorithms approved by IEEE and
Sensor install position Drain valve IEC, the best possible diagnosis of fault conditions can be
Supply voltage 90 ~ 264VAC / 50 ~ 60Hz realized. The Dissolved Gas Analysis, TMS tools or UHF PD
Analysis are available techniques for the Transformer monitoring in
Synchronization PT signal or internal SmartHMI. GIS condition monitoring tools include the partial
discharge, circuit breaker operation, leakage current of lighting
Operation temp. -25 ~ 55℃
arrester, gas density analysis. Cables and other assets
Weight about 20kg assessment tools are provided on request. Alarming set-points
can be setup from the beginning and modified over time as the
Case dimension 411 x 322 x 168mm assets’ normal operating conditions are learned.

I
18 19 HiCMS Hyosung intelligent Condition Monitoring System
On-site Inspection Service
Typical Layout

S/S #1
Operator

GIS Monitoring Electrical Facilities

TR. Monitoring
Manager
MCS, VCB
Web Browser GIS, GCB
DB Server
TRANSFORMER

Provider
S/S #2 Secured Network LA

Operator LA GIS, GCB TRANSFORMER MCS VCB


Smart HMI
Server
S/S #N •Leakage current •Operating characteristics •Dissolved gas analysis •Localized overheating •Open/close performance
•SF6 gas components •Partial discharge •Partial discharge •Vacuum level of valve
Manager
•Partial discharge •OLTC torque check
•Localized overheating •Localized overheating
Smart Device

Provider

Substation IT center Remote location

X ray-based diagnosis of internal condition Abnormal temperature detection Measures internal noise
Display Mode of Web HMI

Transformer partial discharge measurement CB and DS operation testing

Initial display Substation layout GIS monitoring Transformer monitoring

Dissolved gas analysis SF6 gas component analysis


Display Mode of Mobile Device

LA leakage current measurement UHF partial discharge measurement Gas leakage checking

Summary of PD monitoring DGA monitoring


Initial display Trend analysis
S/S condition for GIS for Transformer

I
20 21 HiCMS Hyosung intelligent Condition Monitoring System
Global Network
MOSCOW

BREMEN
COLMAR‐BERG CZESTOCHOWA
BISSEN FRANKFURT
Seoul : MAULBURG
Electronic R&D Center BAD SACKINGEN MURG SIGHISOARA
Gwangju Frozen Storage PITTSBURGH MILANO
OHIO BEIJING
Anyang Plant SOUTH HILL ISTANBUL
BARCELONA BAODING
R&DB Labs SEOUL
Power & Industrial Systems R&D Center LOS ANGELES CHARLOTTE QINGDAO TOKYO
DALLAS DECATUR
NANTONG OSAKA
Oksan Plant ENSENADA NANJING ZHANGJIAGANG
HOUSTON WUHU CHANGSHU
SHANGHAI
Sejong Plant NEW DELHI CHONGQING FUJIAN JIAXING
SHAOXING GUANGZHOU TAIPEI
Daejeon Plant
MEXICO RIYADH QATAR
GUANGDONG KAOHSIUNG
DUBAI ZHUHAI HONGKONG
ABU DHABI MUMBAI
MYANMAR
Gumi Plant
PANAMA BANGKOK MANILA
Jeonju Plant Daegu Plant RAYONG
Ulsan Plant HOCHIMINH
Eonyang Plant
Steel Wire Technical Center Yongyeon Plant KUALA LUMPUR
SINGAPORE
Changwon Plant
Power & Industrial Systems R&D Center

JAKARTA

AMERICANA
SAO PAULO

DOMESTIC SANTA CATARINA


OVERSEAS
DURBAN

13 Plants
4
R&D Centers
34
Manufacturing
10
Trading Entities
28 Trading
Entities (4 affiliated branches) Offices

DOMESTIC NORTH AMERICA ASIA JAPAN EUROPE


Hyosung Japan
TEXTILE & INDUSTRIAL MATERIALS U.S.A CHINA Hyosung Japan Osaka Branch GERMANY
ULSAN PLANT (Nylon/Polyester chips, Nylon fibers, Polyester fibers, Tire cords, Aramid) Hyosung Holdings U.S.A., Inc. (Headquarter) Hyosung Chemical Fiber (Jiaxing) Co., Ltd. Hyosung Corporation Frankfurt Office
GUMI PLANT (Spandex, Polyester fibers) Hyosung Holdings USA, Inc. (Houston Office) Hyosung Chemicals (Jiaxing) Co., Ltd. MALAYSIA Lloyd Dynamowerke GmbH & Co. KG (LDW)
ANYANG PLANT (Rolled carpets, Automotive carpets, Nylon BCF) Hyosung U.S.A., Inc. (Headquarter) Hyosung International Trade (Jiaxing) Co., Ltd. Hyosung Corporation Kuala Lumpur Office GST GmbH - Maulburg
EONYANG PLANT (Steel cords, Bead wires) Hyosung U.S.A., Inc. (Decatur Plant) Hyosung Spandex (Jiaxing) Co., Ltd. GST GmbH - Murg
MYANMAR
DAEJEON PLANT (Tile carpets, PP BCF) Hyosung U.S.A., Inc. (L.A. Office) Hyosung Spandex (Guangdong) Co., Ltd. GST GmbH - Bad Säckingen
Myanmar Hyosung Co., Ltd.
DAEGU PLANT (Dyeing) GST LLC - South Hill Hyosung Composites (Guangdong) Co., Ltd.
JEONJU PLANT (Carbon fibers) HICO America Sales and Technology, Inc. Hyosung Financial System Co., Ltd PHILIPPINES ITALY
Nautilus Hyosung America, Inc. Hyosung Spandex (Zhuhai) Co., Ltd. Hyosung Europe S.R.L.
Hyosung Corporation Manila Office
POWER & INDUSTRIAL SYSTEMS Nautilus Hyosung GSC (Global Software Center) Hyosung Spandex Corporation Shaoxing Office
SINGAPORE LUXEMBOURG
Hyosung Spandex Corporation Zhangjigang Office Hyosung Luxembourg S.A.
CHANGWON PLANT (Transformers, Circuit breakers, Motors) Hyosung Singapore Pte, Ltd.
Hyosung Spandex Corporation Fujian Office
SEJONG PLANT (PV inverter, STATCOM, Welding machine) CENTRAL & SOUTH AMERICA Hyosung Spandex Corporation Qingdao Office
Hyosung Wire Luxembourg S.A.
HGS CHANGWON PLANT (Pumps) TAIWAN
BRAZIL Zhangjiagang Xiao-sha coil Service Co., Ltd.
Hyosung (Taiwan) Corporation
POLAND
Hyosung Do Brasil Ltda. Hyosung Sumiden Steel Cord (Nanjing) Co., Ltd. GST Automotive Safety Poland Sp.z o.o.
CHEMICALS Hyosung Corporation Kaohsiung Office
Hyosung Brasil Ltda. Hyosung Steelcord (Qingdao) Co., Ltd.
YONGYEON PLANT 1 (PP/DH, NF 3) Baoding Hyosung Tianwei Transformer Co., Ltd. THAILAND ROMANIA
Hyosung Brasil Industria E Comercio De Fibras Ltda.
YONGYEON PLANT 2 (TPA, Polyketone) Nantong Hyosung Transformer Co., Ltd. GST Automotive Safety RO S.R.L.
Sumiden Hyosung Steel Cord (Thailand) Co., Ltd.
YONGYEON PLANT 3 (TAC films, PET films) MEXICO Beijing Hyosung Computer Technology Co., Ltd. Hyosung Corporation Bangkok Office RUSSIA
GUMI PLANT (Polyester films, Nylon films) Hyosung Corporation Oficina de Mexico GST Automotive Safety (Changshu) Co., Ltd. Hyosung Corporation Moscow Office
OKSAN PLANT (TAC films, Coating films) GST Automotive Safety Components International S.A. de C.V. Hyosung Corporation Beijing Office U.A.E.
.
Hyosung Russia LLC
Hyosung Corporation Chongqing Office Hyosung Corporation Dubai Office
TRADING / INFORMATION & COMMUNICATION PANAMA Hyosung Corporation Guangzhou Office Hyosung Corporation – Abu Dhabi Office SPAIN
GUMI PLANT (ATM) Hyosung Corporation Panama Office
Hyosung Corporation Shanghai Office Hyosung Corporation Barcelona Office
GWANGJU FROZEN STORAGE
VIETNAM
Hyosung Corporation Wuhu Office
AFRICA Hyosung Vietnam Co., Ltd. TURKEY
HONG KONG Hyosung Dong Nai Co., Ltd. Hyosung Istanbul Tekstil Ltd Sti
SOUTH AFRICA Hyosung International (HK) Ltd. Hyosung Corporation Hochiminh Office Hyosung Corporation Istanbul Office
GST Automotive Safety South Africa (Proprietary) Limited
INDIA QATAR
Hyosung Corporation India Pvt. Ltd., Hyosung Corporation Qatar Office
Nautilus Hyosung India Office
SAUDI ARABIA
INDONESIA Hyosung Corporation Saudi Arabia Office
Hyosung Corporation Jakarta Office
Nautilus Hyosung Indonesia Office

I
22 23 HiCMS Hyosung intelligent Condition Monitoring System