Wind Load Calculation 29-08-2018

This document provides details for calculating wind loads on a 20.02m long structure with a roof slope of 15 degrees. It specifies parameters such as basic wind velocity, building type factor, effective height, dynamic pressure, and wind speed adjustment factors. It then calculates the external pressure coefficient, internal pressure coefficient, dynamic roof pressure, and resulting net wind pressures on the roof for different wind directions and zones. The maximum net suction pressure is found to be -1.77 kN/m2.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
339 views4 pages

Wind Load Calculation 29-08-2018

This document provides details for calculating wind loads on a 20.02m long structure with a roof slope of 15 degrees. It specifies parameters such as basic wind velocity, building type factor, effective height, dynamic pressure, and wind speed adjustment factors. It then calculates the external pressure coefficient, internal pressure coefficient, dynamic roof pressure, and resulting net wind pressures on the roof for different wind directions and zones. The maximum net suction pressure is found to be -1.77 kN/m2.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

WIND LOAD CALCULATION

Total Length - L - 20.02m

Spacing - S - 1.82m

Bay Width - B - 13.20m

Height - H - 1.5m

Roof Slope (e) - α - 15°

Basic wind velocity as per DM

- Vb - 35m/s

Building type factor Kb

Building Type Factor Kb

Type of Building = Welded => Kb = 8

Effective Height = Reference Height = He = 1.5m

Dynamic Pressure = qs = 0.613 Ve2

Effective Wind Speed = Ve = Vs x Sb

Site Wind Speed = Vs = Vb x Sa x Sd x Ss x Sp

From BS 6399 – 2 Section 2.2.2.2

Site Altitude above sea level = Δs = 50m

Altitude Factor = Sa = 1 + 0.001 Δs = 1.05

From BS 6399 – 2 Section 2.2.2.3

Direction Factor = Sd = 1 (For Unknown Wind Direction)

From BS 6399 – 2 Section 2.2.2.4

Seasonal Factor = Ss = 1

From BS 6399 – 2 Section 2.2.2.5

Probability Factor = Sp = 1

Vs = Vb x Sa x Sd x Ss x Sp

Vs = 35 x 1.05 x 1 x 1 x 1 = 36.75m/s

From BS 6399 – 2 Section 2.2.3.3‐Table 4

Terrain & Building Factor = Sb = 1.58

Effective Wind Speed = Ve = Vs x Sb

Ve = 31.5 x 1.58 = 58.06m/s


Not Considering External & Internal Pressure for walls, due to no walls

Only considering Roof Pressures.

External Pressure Co‐efficient = Cpe

From BS 6399 – 2 Table 10

Pressure
Pitch Zone for θ = 0°
Type
Angle α
Leeward A B C E F G

15° Suction -1.1 -0.8 -0.4 -1.3 -0.9 -0.5

Pressure
Pitch Zone for θ = 0°
Type
Angle α
Windward A B C E F G

15° Pressure +0.2 +0.2  +0.2  -1.3 -0.9 -0.5

Pressure
Pitch Zone for θ = 90°
Type
Angle α
Leeward A B C D

15° Suction -1.6 -1.5 -0.6 -0.4

Size effect factor for External Pressure = Cae

From BS 6399 – 2 from Fig.4

Cae = 0.87

Internal Pressure Co‐efficient = Cpi

From BS 6399 – 2 Table 16

Four walls equally permeable & Roof Impermeable = Cpi =-0.3

Size effect factor for Internal Pressure = Cie

From BS 6399 – 2 Clause 2.1.3.4

Cai = 0.78 from Fig.4

Dynamic Pressure = qs = 0.613 x Ve2

From BS 6399 – 2 from Fig.4

qs = 1.52 Kn/m2
External Surface Pressure Pe = qs x Cpe x Cae

Pressure

Type Zone for θ = 0°

Kn/m2

Leeward A B C E F G

Suction -1.45 -1.05 -0.53 -1.72 -1.19 -0.66

Pressure

Type Zone for θ = 0°

Kn/m2

Windward A B C E F G

Pressure +0.26 +0.26 +0.26 -1.72 -1.19 -0.66

Pressure Type
Zone for θ = 90°
Kn/m2

Leeward A B C D

Suction -2.12 -1.98 -0.79 -0.53

Internal Surface Pressure Pi = qs x Cpi x Cai

Pi = -0.35 Kn/m2
Net Pressure P = Pe - Pi

Pressure

Type Net Pressure at zone for θ = 0°

Kn/m2

Leeward A B C E F G

Suction -1.1 -0.7 -0.18 -1.37 -0.84 -0.31

Pressure

Type Net Pressure at zone for θ = 0°

Kn/m2

Windward A B C E F G

Pressure +0.61 +0.61 +0.61 -1.37 -0.84 -0.31

Pressure Type
Net Pressure at zone for θ = 90°
Kn/m2

Leeward A B C D

Suction -1.77 -1.63 -0.44 -0.18