0% found this document useful (0 votes)
118 views

Design of Isolated Footing For Security Room: Node No. XD

This document provides the design of an isolated footing for a security room column. It details the column and load specifications, calculates the required and provided footing size and reinforcement, and verifies the footing design is safe based on bearing pressure, bending moment, shear, and punching shear checks.

Uploaded by

venu manikanta
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
118 views

Design of Isolated Footing For Security Room: Node No. XD

This document provides the design of an isolated footing for a security room column. It details the column and load specifications, calculates the required and provided footing size and reinforcement, and verifies the footing design is safe based on bearing pressure, bending moment, shear, and punching shear checks.

Uploaded by

venu manikanta
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 12

DESIGN OF ISOLATED FOOTING FOR SECURITY ROOM

NODE NO. = 16

Size of Column ( Bc x Dc ) = 0.325 x 0.325 m

Grade of Concrete ( fck ) M 30


Pu Mx
Grade of Steel ( fy ) Fe 500 238.739 10.25

Xumax / d = 0.46 Column Size


0.325 x 0.325
Ru = 4.02

Load acting on the Column ( P ) = 159.16 kN

Moment about X-Axis ( Mx ) = 6.83 kNm

Moment about Z-Axis ( Mz ) = 3.78 kNm

Total load on Footing ( W = 1.1*P ) = 175.08 kN

Safe bearing capacity of soil ( g safe ) = 50 kN/m2

Area of Footing required ( A = W / g safe ) = 3.5 m2

Size of Footing required ( Bf x Df ) = 1 x 2 m

Provided size of Footing ( Bf x Df ) = 2.2 x 2.2 m

Area of Footing provided ( A ) = 4.84 m2 SAFE

Check for Bearing Pressure:

( P/A ) + ( 6 x Mx / ( Bf x Df2 ) + ( 6 x Mz / (Bf x Df2 ) = 42.15 < 50 SAFE


( EQ governing case,
SBC increased by 25% )
( EQ governing case,
SBC increased by 25% )

( P/A ) - ( 6 x Mx / Bf x Df2 ) - ( 6 x Mz / Bf x Df2 ) = 30.19 > 0 SAFE

Footing is Safe in BEARING PRESSURE


Size of Column ( Bc x Dc ) = 0.325 x 0.325 m

Net upward pressure due to fac. Load (rmax) = 58.29 kN/m2

Net upward pressure due to fac. Load (rmin) = 40.36 kN/m2

Along Short Span: =

Moment, Mu = r Bf ( Bf - Bp )2/2 = 56.35 kNm

Depth of Footing required for B.M = 79.82 mm


( Dreq = sqrt ( Mu / Ru*Bf ) )

Provided Depth of Footing ( D ) = 350 mm

Assumed cover for Footing ( dc ) = 50 mm

Effective Depth ( d ) = 282 mm

Mu / Bf d2 = 0.322 B.M SAFE


Shear SAFE
Punching SAFE
% Steel required, Pt req ( from SP:16 ) = 0.12

Required Steel Area ( Ast req ) = 744.48 mm2

Diameter of Bars provided ( f ) = 12 mm

Area of each 12mm dia bar = 113.1 mm2

No. of 12mm dia bars required = 7 no's

Spacing of main bars required ( S req ) = 314 mm

Spacing of main bars provided ( S prov ) = 150 mm SAFE

Provided Pt = 0.27 %
Provide 12T @ 150mm c/c in Both directions

CHECK FOR ONE WAY SHEAR:

Shear force at critical section ( Vu ) = 84.06 KN


Vu = p Bf [0.5 ( Bf - Bc )-d ]
Effective width at critical section ( B'f ) = 2200 mm

Effective depth at critical section ( d' ) = 282 mm

Nominal shear stress ( t v = Vu / B'f d' ) = 0.14 N/mm2

Permissible shear stress in concrete ( t c ) = 0.38 N/mm2 > 0.14

Footing is Safe in ONE WAY SHEAR

CHECK FOR TWO WAY SHEAR:

Maximum Load, Pu = 238.74 kN

Perimeter of Footing at critical section = 2428 mm


Bo = [ 2*( Bc + Dc ) + 4d ]

Shear force at critical section, Vc = 22.47 kN

Net Shear force, Vu = 216.27 kN

Effective Depth at critical section, ( do ) = 282 mm

Shear Stress ( t v ) = 0.32 N/mm2

ks = 1

Maximum allowable Punching Shear, ( t 'c ) = 1.37 N/mm2 > 0.32


t'c = ks*0.25*sqrt( fck )

Footing is Safe in PUNCHING

Along Long Span:

Moment, Mu = r Bf ( Bf - Bp )2/2 = 56.35 kNm

Depth of Footing required for B.M = 79.82 mm


( Dreq = sqrt ( Mu / Ru*Bf ) )

Provided Depth of Footing ( D ) = 400 mm

Assumed cover for Footing ( dc ) = 50 mm

Effective Depth ( d ) = 344 mm


Mu / Bf d2 = 0.216 B.M SAFE
Shear SAFE
% Steel required, Pt req, from SP:16 = 0.12

Required Steel Area ( Ast req ) = 908.16 mm2

Diameter of Bars provided ( f ) = 12 mm

Area of each 12mm dia bar = 113.1 mm2

No. of 12mm dia bars required = 8 no's

Spacing of main bars required ( S req ) = 275 mm

Spacing of main bars provided ( S prov ) = 150 mm SAFE

Provided Pt = 0.22 %

Provide 12T @ 150mm c/c in Both directions

CHECK FOR ONE WAY SHEAR:

Shear force at critical section ( Vu ) = 76.11 kN


Vu = p Bf [0.5 ( Bf - Bc )-d ]

Effective width at critical section ( B'f ) = 2200 mm

Effective depth at critical section ( d' ) = 344 mm

Nominal shear stress ( t v = Vu / B'f d' ) = 0.1 N/mm2

Permissible shear stress in concrete ( t c ) = 0.35 N/mm2 > 0.1

Footing is Safe in ONE WAY SHEAR

Footing Dimensions:
2.20 x 2.20 x 0.35
Reinforcement Details:

Short Span:
12T @ 150mm c/c
Long Span:
12T @ 150mm c/c
CURITY ROOM

Mz
5.676

Column Size
0.325 x 0.325
N/mm2

N/mm2
N/mm2