EXPANSION ANCHOR
Technical Datasheet
Update: Apr-18
HST3 Expansion anchor
Ultimate-performance expansion anchor for cracked concrete and seismic
Anchor version Benefits
- Highest resistance for reduced member
thickness, short spacing and edge
distances
HST3
HST3-R - Increased undercut percentage in
(M8-M24) combination with optimized coating
- Suitable for non-cracked and cracked
concrete C 12/15 to C 80/95
- Highly reliable and safe anchor for
structural seismic design with ETA
C1/C2 approval
- Flexibility with two embedment depths
included in the ETA
- Minimum edge and spacing distances
HST3-BW reduced by up to 25% compared to HST
HST3-R-BW
- Design tension resistance increased by
(M8-M24)
up to 66% compared to HST
- Product and length identification mark
facilitates quality control and inspection
Approvals / certificates
Description Authority / Laboratory No. / date of issue
European technical assessment a) DIBt, Berlin ETA-98/0001 / 2018-02-09
Fire test report DIBt, Berlin ETA-98/0001 / 2018-02-09
Shock approval FOCP, Zurich BZS D 08-602 / 2016-08-17
a) All data given in this section according to ETA-98/0001, issue 2017-20-07.
1 Updated: Apr-18
Static and quasi-static loading (for a single anchor)
Characteristic resistance
Anchor size M8 M10 M12 M16 M20 M24
Non-cracked concrete
Tension HST3/HST3-BW 12,0 12,8 22,0 17,9 25,0 26,5 39,6 51,3 60,0
[kN]
NRk HST3-R/HST3-R-BW 12,0 12,8 22,0 17,9 25,0 26,5 39,6 51,3 60,0
Shear HST3/HST3-BW 13,8 21,9 23,6 34,0 35,4 54,5 55,3 83,9 94,0
[kN]
VRk HST3-R/HST3-R-BW 15,7 25,6 25,3 31,1 36,7 48,6 63,6 97,2 115,0
Cracked concrete
Tension HST3/HST3-BW 8,0 9,1 15,0 12,7 20,0 18,9 28,2 36,5 40,0
[kN]
NRk HST3-R/HST3-R-BW 8,5 9,1 15,0 12,7 20,0 18,9 28,2 36,5 40,0
Shear HST3/HST3-BW 13,8 21,9 23,6 34,0 35,4 54,5 55,3 83,9 94,0
[kN]
VRk HST3-R/HST3-R-BW 15,7 24,3 25,3 31,1 36,7 48,6 63,6 97,2 115,0
Updated: Apr-18 2
Design resistance
Anchor size M8 M10 M12 M16 M20 M24
Non-cracked concrete
Tension HST3/HST3-BW 8,0 8,5 14,7 11,9 16,7 17,6 26,4 34,2 40,0
[kN]
NRd HST3-R/HST3-R-BW 8,0 8,5 14,7 11,9 16,7 17,6 26,4 34,2 40,0
Shear HST3/HST3-BW 11,0 17,5 18,9 27,2 28,3 43,6 44,2 67,1 62,7
[kN]
VRd HST3-R/HST3-R-BW 12,6 20,5 20,2 24,9 29,4 38,9 50,9 77,8 88,5
Cracked concrete
Tension HST3/HST3-BW 5,3 6,1 10,0 8,5 13,3 12,6 18,8 24,4 26,7
[kN]
NRd HST3-R/HST3-R-BW 5,7 6,1 10,0 8,5 13,3 12,6 18,8 24,4 26,7
Shear HST3/HST3-BW 11,0 16,2 18,9 23,6 28,3 42,9 44,2 67,1 62,7
[kN]
VRd HST3-R/HST3-R-BW 12,6 16,2 20,2 23,6 29,4 38,9 50,9 77,8 83,9
Recommended loadsa)
Anchor size M8 M10 M12 M16 M20 M24
Non-cracked concrete
Tension HST3/HST3-BW 5,7 6,1 10,5 8,5 11,9 12,6 18,8 24,4 28,6
[kN]
NRec HST3-R/HST3-R-BW 5,7 6,1 10,5 8,5 11,9 12,6 18,8 24,4 28,6
Shear HST3/HST3-BW 7,9 12,5 13,5 19,4 20,2 31,1 31,6 47,9 44,8
[kN]
VRec HST3-R/HST3-R-BW 9,0 14,6 14,5 17,8 21,0 27,8 36,3 55,5 63,2
Cracked concrete
Tension HST3/HST3-BW 3,8 4,3 7,1 6,1 9,5 9,0 13,4 17,4 19,0
[kN]
NRec HST3-R/HST3-R-BW 4,0 4,3 7,1 6,1 9,5 9,0 13,4 17,4 19,0
Shear HST3/HST3-BW 7,9 11,6 13,5 16,8 20,2 30,6 31,6 47,9 44,8
[kN]
VRec HST3-R/HST3-R-BW 9,0 11,6 14,5 16,8 21,0 27,8 36,3 55,5 59,9
a) With overall partial safety factor for action = 1,4, The partial safety factors for action depend on the type of loading and shall be
taken from national regulations,
3 Updated: Apr-18
Design resistance in case of seismic performance C2
Anchor size M8 M10 M12 M16 M20 M24
Tension HST3 / HST3-BW 2,0 6,9 11,9 16,0 20,7 -
[kN]
NRd, seis HST3-R / HST3-R-BW 2,3 6,9 11,9 16,0 20,7 -
Shear HST3 / HST3-BW 7,9 15,2 22,9 38,8 66,3 -
[kN]
VRd,seis HST3-R / HST3-R-BW 7,9 13,8 22,1 34,0 53,9 -
Fire resistance
Characteristic resistance
Anchor size M8 M10 M12 M16 M20 M24
Fire Exposure R30
Tension HST3/HST3-BW 0,9 1,5 2,4 2,3 5,0 4,4 7,1 9,1 12,6
[kN]
NRk,fi HST3-R/HST3-R-BW 1,9 1,8 3,0 3,2 5,0 4,7 7,1 9,1 12,6
Shear HST3/HST3-BW 0,9 1,5 2,4 2,3 5,2 4,4 9,7 15,2 21,9
[kN]
VRk,fi HST3-R/HST3-R-BW 4,9 4,7 11,8 8,9 17,1 16,9 31,9 37,0 62,8
Fire Exposure R120
Tension HST3/HST3-BW 0,6 0,8 0,9 0,8 1,3 1,5 2,4 3,8 5,4
[kN]
NRk,fi HST3-R/HST3-R-BW 1,5 1,5 2,4 2,5 4,0 3,8 5,6 7,3 10,1
Shear HST3/HST3-BW 0,6 0,8 0,9 0,8 1,5 1,5 2,4 3,8 5,4
[kN]
VRk,fi HST3-R/HST3-R-BW 1,7 2,0 3,3 3,3 4,8 6,2 9,0 14,1 20,3
Updated: Apr-18 4
Design resistance
Anchor size M8 M10 M12 M16 M20 M24
Fire Exposure R30
Tension HST3/HST3-BW 0,9 1,5 2,4 2,3 5,0 4,4 7,1 9,1 12,6
[kN]
NRd,fi HST3-R/HST3-R-BW 1,9 1,8 3,0 3,2 5,0 4,7 7,1 9,1 12,6
Shear HST3/HST3-BW 0,9 1,5 2,4 2,3 5,2 4,4 9,7 15,2 21,9
[kN]
VRd,fi HST3-R/HST3-R-BW 4,9 4,7 11,8 8,9 17,1 16,9 31,9 37,0 62,8
Fire Exposure R120
Tension HST3/HST3-BW 0,6 0,8 0,9 0,8 1,3 1,5 2,4 3,8 5,4
[kN]
NRd,fi HST3-R/HST3-R-BW 1,5 1,5 2,4 2,5 4,0 3,8 5,6 7,3 10,1
Shear HST3/HST3-BW 0,6 0,8 0,9 0,8 1,5 1,5 2,4 3,8 5,4
[kN]
VRd,fi HST3-R/HST3-R-BW 1,7 2,0 3,3 3,3 4,8 6,2 9,0 14,1 20,3
Materials
Mechanical properties
Anchor size M8 M10 M12 M16 M20 M24
Nominal tensile HST3/HST3-BW 800 800 800 720 700 530
[N/mm²]
strength fuk,thread HST3-R/HST3-R-BW 720 710 710 650 650 650
Yield strength HST3/HST3-BW 640 640 640 576 560 450
fyk,thread HST3-R/HST3-R-BW [N/mm²] 576 568 568 520 520 500
Stressed cross-section As [mm²] 36,6 58,0 84,3 157 245 353
Moment of resistance W [mm³] 31,2 62,3 109 277 541 935
Char, bending HST3/HST3-BW 30 60 105 240 457 595
[Nm]
resistance M0Rk,s HST3-R/HST3-R-BW 27 53 93 216 425 730
Material quality
Part Material
M10, M16: Galvanized or Stainless steel
Expansion HST3/HST3-BW
M8, M12, M20, M24: Stainless steel
sleeve
HST3-R/HST3-R-BW Stainless steel A4
HST3/HST3-BW Carbon steel, galvanized, coated (transparent)
Bolt
HST3-R/HST3-R-BW Stainless steel A4, cone coated (transparent)
HST3/HST3-BW Galvanized
Washer
HST3-R/HST3-R-BW Stainless steel A4
HST3/HST3-BW Strength class 8
Hexagon nut
HST3-R/HST3-R-BW Stainless steel A4, coated
5 Updated: Apr-18
Setting information
Setting details
Anchor size M8 M10 M12 M16 M20 M24
Nominal diameter of drill bit do [mm] 8 10 12 16 20 24
Cutting diameter of drill bit dcut ≤ [mm] 8,45 10,45 12,5 16,5 20,55 24,55
hef,1 [mm] - 40 50 65 - -
Effective embedment depth
hef,2 [mm] 47 60 70 85 101 125
h1,1 ≥ [mm] - 53 68 86 - -
Drill hole depth1)
h1,2 ≥ 59 73 88 106 124 151
hnom,1 [mm] - 48 60 78 - -
Thread engagement length
hnom,2 [mm] 54 68 80 98 116 143
Maximum diameter of clearance
df [mm] 9 12 14 18 22 26
hole in the fixture
Torque moment Tinst [Nm] 20 45 60 110 180 300
Maximum thickness of fixture tfix,max [mm] 195 220 270 370 310 330
Width across ≤
SW [mm] 13 17 19 24 30 36
1) In case of diamond drilling +5 mm for M8 to M10 and +2 mm for M12 to M24.
Installation equipment
Anchor size M8 M10 M12 M16 M20 M24
Rotary hammer TE2(-A) – TE30(-A) TE40 – TE80
Diamond coring tool DD-30W, DD-EC1
Setting tool Hilti S7W 6AT 22A – SI-AT-A22 -
Hollow drill bit - TE-CD, TE-YD
Other tools hammer, torque wrench, blow out pump
Updated: Apr-18 6
Setting parameters of HST3 / HST3-R for M8 and M10
M10
Anchor Size M8
C20/25 to C50/60a) C12/15b) C12/15 to C20/25 to C50/60a) C12/15b)
Concrete class C55/67 to C80/95b) C16/20b) C16/20a) C55/67 to C80/95b) C16/20b)
Effective anchorage
hef [mm] 47 47 40 60 60
depth
Minimum base material
hmin [mm] 80 100 100 80 100 120 120
thickness
Minimum spacing in smin [mm] 35 35 35 50 40 40 70
non-cracked concrete for c ≥ [mm] 55 50 65 95 100 60 90
Minimum spacing in smin [mm] 35 35 35 40 40 40 45
cracked concrete for c ≥ [mm] 50 50 55 90 100 55 85
Minimum edge distance cmin [mm] 40 40 50 50 60 50 80
in non-cracked concrete for s ≥ [mm] 50 50 80 190 90 90 120
Minimum edge distance cmin [mm] 40 40 40 45 60 45 70
in cracked concrete for s ≥ [mm] 50 50 75 180 90 80 120
Critical spacing for scr,sp [mm] 141 188 168 180 240
splitting failure and
concrete cone failure scr,N [mm] 141 141 120 180 180
Critical edge distance for ccr,sp [mm] 71 94 84 90 120
splitting failure and
concrete cone failure ccr,N [mm] 71 71 60 90 90
7 Updated: Apr-18
Setting parameters of HST3(-BW) / HST3-R(-BW) for M20 and M24
Anchor Size M20 M24
C20/25 to C50/60a) C12/15b) C20/25 to C50/60a) C12/15b)
Concrete class C55/67 to C80/95b) C16/20b) C55/67 to C80/95b) C16/20b)
Effective anchorage hef [mm] 101 101 125 125
depth
Minimum base material hmin [mm] 160 200 200 250 250
thickness
Minimum HST3 smin [mm] 120 90 90 125 180
spacing in HST3-BW for c ≥ [mm] 180 130 165 255 375
non-cracked HST3-R smin [mm] 120 90 90 125 180
concrete HST3-R-BW for c ≥ [mm] 180 130 165 205 375
Minimum HST3 smin [mm] 120 90 90 125 140
spacing in for c ≥
HST3-BW [mm] 180 130 165 180 325
cracked HST3- smin [mm] 120 90 90 125 140
concrete RHST3-R-BW for c ≥ [mm] 180 130 140 130 325
Min. edge HST3 cmin [mm] 120 80 90 170 260
distance in HST3-BW for s ≥ [mm] 180 180 140 295 400
non-cracked HST3-R cmin [mm] 120 80 120 150 260
concrete HST3-R-BW for s ≥ [mm] 180 180 270 235 400
Min. edge HST3 cmin [mm] 120 80 100 125 230
distance in HST3-BW for s ≥ [mm] 180 180 240 240 295
cracked HST3-R cmin [mm] 120 80 100 125 230
concrete HST3-R-BW for s ≥ [mm] 180 180 240 140 295
Critical spacing for scr,sp [mm] 384 404 375 500
splitting failure and concrete
cone failure scr,N [mm] 303 303 375 375
Critical spacing for ccr,sp [mm] 192 202 188 250
splitting failure and
concrete cone failure ccr,N [mm] 152 152 188 188
a) Data covered by ETA-98/0001 issue 2017-20-07.
b) Data covered by Hilti Technical Data
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to
be reduced.
Updated: Apr-18 8
Setting instructions
*For detailed information on installation see instruction for use given with the package of the product
Setting instruction for HST3, HST3-BW, HST3-R, HST3-R-BW
Hammer drilling (M8, M10, M12, M16, M20, M24)
1. Drill the hole 2. Clean the hole
3a. Insert the anchor with hammer 3a. Insert the anchor with setting tool HS-SC
5b. Torque with impact wrench with Adaptative torque module (M8-M12)
9 Updated: Apr-18
5a. Torque with calibrated torque wrench (M8-M24) 5b. Torque with impact wrench with Adaptative
torque module (M8-M12)
6a. Torque with calibrated torque wrench (M8-M24) 5b. Torque with impact wrench with Adaptative
torque module (M8-M12)
Updated: Apr-18 10