Frequency Measuring Transducer

The document describes a FAMA frequency transducer that measures the frequency of an input voltage and outputs a load-independent DC voltage or current signal. It transforms the input voltage into a pulse train with a frequency proportional to the input. The pulse train is then filtered and amplified to produce the DC output. The transducer has high input resistance, low response time, and excellent linearity. It is used in instrumentation, PLCs, and control systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
94 views2 pages

Frequency Measuring Transducer

The document describes a FAMA frequency transducer that measures the frequency of an input voltage and outputs a load-independent DC voltage or current signal. It transforms the input voltage into a pulse train with a frequency proportional to the input. The pulse train is then filtered and amplified to produce the DC output. The transducer has high input resistance, low response time, and excellent linearity. It is used in instrumentation, PLCs, and control systems.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

B1 B2

FAMA
FREQUENCY
TRANSDUCER

75,0 mm
SUPPLY

OUTPUT
OFFSET ZERO
FREQUENCY MEASURING
TRANSDUCER
VOLT 5V
10mA

10V

Type: FAMA
mAMP 20mA
NO OFFSET

+ - A1 A2

35,0 mm 100,0 mm

105,0 mm

FEATURES Description:
The transducer type FAMA is used to measure the frequency of an
input voltage. The output is a load independent DC voltage or current
• High input resistance signal. The input can be connected directly or via transformers.
• Low response time
• Excellent linearity Operation:
• All ranges class 0.5 according to EN60688. The input voltage is transformed to a suitable signal level. At each
zero-crossing the input creates a rectangular pulse with a constant
• 8 outputs available height and width. The pulse train, with a frequency proportional to
• Isolation > 4kV. Input, output and supply. that of the input voltage, is filtered and in amplifier converted to a
load independent DC output. The input voltage can also be used
• All standard AC voltages for power supply. as supply voltage. The supply voltage is galvanically separated by
Optional combined AC and DC supply. the plug-in transformer.

Applications:
Instrumentation, PLCs, PC and microprocessor control systems .

FUNCTION DIAGRAM
AC Supply AC/DC Supply

AC supply Supply
Isolation Isolation
=
˜=
A2
˜=
A2 Supply
Supply
A1 A1 =
AC input AC input
B2 B2 +
Input
˜=
+ DC output
-
Input
B1 ˜= -
DC output

{
B1
Signal
Isolation {
Output
Signal
Isolation Output

OUTPUT CHARACTERISTICS OUTPUT ACTUATOR

OUT
OUT
0 - 10 mA

2 - 10 mA

IN 0 - 20 mA
IN
4 - 20 mA

0 - 5V

1 - 5V
Output: 0 - 10 mA, 0 - 20 mA Output: 2 - 10 mA, 4 - 20 mA
0 - 10 V
0 - 5 V, 0 - 10 V 1 - 5 V, 2 - 10 V
2 - 10 V

CONNECTION DIAGRAM
Rail mounting Socket mounting
B1 B2

6
5 7
B1 B3
4 8

FAMA 3 9

2 10
+ - A1 A2 1 11
A1 + - A2

Output Supply

77

Thiim A/S Transformervej 31 Tel.: +45 4485 8000 Web: www.thiim.com


2860 Søborg - Denmark Fax: +45 4485 8005 Mail: [email protected]
SPECIFICATIONS ORDERING INFORMATION

INPUT FAMA AC voltage EXAMPLE: FAMA 450 1 550 1 400 2 B 230 D A 3 C


Nominal input VN Specify from 10 to 600 V
Max. continuous input 40√UN V rms. 10 V < UN < 300 V TYPE
720 V rms. UN > 300 V Frequency measuring transducer FAMA
Input resistance approx. 2 KΩ / V
AC frequency range 0 to 5000 Hz FREQUENCY RANGE
Lower level
PERFORMANCE PARAMETERS The first three figures of the
TIMING frequency in Hz, e.g. 45.0 Hz xxx
Response time < 200 msec. 0-90% or 100-10%
ELECTRICAL Followed by:
Precision Class 0.5 0 for Hz = 1.00 to 9.99 0
Linearity < 0.2 % 1 for Hz = 10.0 to 99.9 1
Supply dependence < ± 0.01 % / % DU supply 2 for Hz = 100 to 999 2
Temp. dependence < ± 0.01 % / °C
Ripple < 1 % pp High level
The first three figures of the
OUTPUT frequency in Hz, e.g. 55.0 Hz xxx
The output amplifier is protected against open and short circuit.
Followed by:
SUPPLY 0 for Hz = 1.00 to 9.99 0
AC and DC 18-360 VDC and 20-264 VAC 1 for Hz = 10.0 to 99.9 1
with isolated switchmode supply 2 for Hz = 100 to 999 2

AC supply range 24 V (From 20 to 28 V)
with transformer 110 V (From 99 to 140 V) VOLTAGE RANGE
230 V (From 198 to 264 V) The first three figures of the
400 V (From 342 to 484 V) voltage in Volt, e.g. 400 V 400

Frequency range 45 to 440 Hz (transformer)


Power consumption 2.5 VA, 1.1 W Followed by:
Frequency range 45 to 440 Hz 1 for V = 10.0 to 99.9 1
Power consumption 2.5 VA, 1.5 W 2 for V = 100 to 999 2
PLUG-IN supply module According to specifications

SUPPLY VOLTAGE
GENERAL 18-360 VDC and 20-264VAC E400
Temperature range - 25 °C to + 55 °C 20-28 VAC B024
Humidity Up to 90 % RH non-condensing 99-140 VAC B110
Dielectric test voltage Input to output 4000 VAC 198-264 VAC B230
Input to supply (internal) 4000 VAC 342-484 VAC B400
Output to supply (internal) 4000 VAC 352-576VAC B460
Weight 0.20 kg with internal supply
OUTPUT
Programmable with dipswitch D
0 - 10 mA, 2 - 10 mA,
International Standards 0 - 20 mA, 4 - 20 mA,
EMC directive 89/336: EN50081 - Emission 0 - 5 V, 1 - 5V
EN50082 - Immunity 0 - 10 V, 2 - 10 V
Low voltage directive 73/23: EN60255 - Electrical Relays
EN60688 - Measuring transducers HOUSING
Rail mounting with internal supply A
Socket 11 pin with internal supply E

SIZE
35 mm. 3

CODE
Code end C
Extended code E

78

We reserve the right to make changes for product improvement. FAMA.indd - 241114