Sam Chef Col Service
Sam Chef Col Service
Sam Chef Col Service
Section 1: Refrigerator
Service Modes
Components Page 15
Troubleshooting Errors
Installation Page 3
Troubleshooting Page 7
Bluetooth Page 8
Section 3: Combo-Oven
This course is designed to update experienced technicians on the 2017 Samsung Chef Collection products
including refrigerators, vent hood, combo-ovens and cook tops.
Upon successful completion of this course, the attendees will be able to:
Activate - Press Ice Maker + Filter Reset + Control Lock until 0 – FF appears
Deactivate - Repeat above step until Normal temperature settings are displayed
Force Mode
1. Press Freezer+ Control Lock for 5 seconds and release when it blinks
Notes:
Inverter Board
Enter Force Mode to activate *FF-Fr-F FF- C FF- A FF* note A FF will activate all
Notes:
TDM BRF9000 – 42in
The Time Divided Multi-Cycle (TDM) System (Stepper Valve) is used to switch refrigerant flow.
This improves temperature control and energy efficiency.
Freezer + CV side
Fridge side
Notes:
Force Mode – BRF8000 – 36in
Load Mode will display what is running or active, with the use of the reference chart
Notes:
Load Mode – Reference Codes
Notes:
Diagnostic Mode
HASS Port
HASS Cables
Components
Power Switch
Notes:
SMPS PBA – Power Board
Notes:
Main PCB
Network and Wi-fi
Wi-Fi Module
DA92-00960A
Notes:
USB Hub PBA
Notes:
Inverter Location on 42in
Inverter PBA
Notes:
7C – Pantry Sensor Error
Notes:
13-C Ambient Humidity Sensor Error
Notes:
21-C Freezer Fan Error
Notes:
22-C R Fan Error
Notes:
23-C Condenser Fan Motor
Notes:
24-C Freezer Defrost Error
Notes:
24-C Freezer Defrost Error
Notes:
26-C Ice Maker Function Error
Notes:
29-C CV-Defrost Error – Voltage Check
Notes:
31-C CV-Fan Error
Notes:
33-C Ice Maker Heater error
Notes:
44-C / 45C : Communication Error between Main PCB and Inverter PCB
Notes:
62-C: Pantry Fan Error
Notes:
71-C: Abnormal High Freezer Temperature
When its door remains open for an extended time or high temperature food is stored, close the door or take
out the hot food. Then, after a while, the error will disappear
77-C: Camera Error
Notes:
82-C: F-Compressor IPM Fault Error.
Notes:
84-C: F-Compressor Motor Restriction
Notes:
86-C: F-Compressor High Voltage
Notes:
88-C: R-Compressor IPM Fault Error
Notes:
90-C: R-Compressor Motor Restriction
Notes:
92-C: R-Compressor High Voltage
Notes:
Troubleshooting - Top 5 Symptoms
Symptom: Unit not Operating, No power
Notes:
Symptom. Sensor Error Code
Symptom. Fan Not Operating
The control panel is controlled by touch for:
Fan speeds (3 + Boost)
LED light on/off
Variable timer
In addition, vent hood can be controlled remotely with smart phone or tablet via Bluetooth.
Notes:
Notes:
Notes:
Notes:
Notes:
Notes:
Notes:
Notes:
Notes:
Notes:
Notes:
Notes:
Notes: