The TTN-D8/MUX-4X2 digital multiplexing relay board allows up to 8 sensors to be connected and sequentially sampled through 2 analog inputs on a Titan I/O module. It provides relays to switch 2 groups of 4 sensors each. Applications must be tolerant of intermittent sampling at a minimum rate of around 15 seconds. The board is compact at 4" x 2" x 1.5", uses 2.5W of power, and easily installs via a single screw connection to the I/O module.

Uploaded by

fahmi1987
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
44 views2 pages

TTN d8 Mux 4x2 Data Sheet

The TTN-D8/MUX-4X2 digital multiplexing relay board allows up to 8 sensors to be connected and sequentially sampled through 2 analog inputs on a Titan I/O module. It provides relays to switch 2 groups of 4 sensors each. Applications must be tolerant of intermittent sampling at a minimum rate of around 15 seconds. The board is compact at 4" x 2" x 1.5", uses 2.5W of power, and easily installs via a single screw connection to the I/O module.

Uploaded by

fahmi1987
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TTN-D8/MUX-4X2

Digital Multiplexing Output Relay Board

The Titan D8/MUX-4X2 provides relays for sequential


switching of 2 groups of 4 sensors each into two analog
inputs on the Titan I/O module.

www.arguscontrols.com

Applications
This module is used in special
applications enabling 2 sets of up to 4
sensors each to share a common
input on the Titan I/O module. For
example, 2 analog inputs on an I/O
module can be used for sampling up
to 4 temperature sensors each. Since
each sensor is switched on
individually and sequentially, any
applications using this type of
configuration must be tolerant of
intermittent sampling and a minimum
sample refresh rate of about 15
seconds.

Alternatives

For sensor multiplexing applications the TTN-D8/MUX-8X1 can multiplex 1 set of 8 sensors
into a single input on Titan I/O module. This uses the smallest possible number of analog
inputs but reduces the minimum sampling frequency. The TTN-D8/MUX-3.0V is identical to
the TTN-D8MUX-8X1 except that it provides on-board 3.0 volt excitation for interfacing with
either Decagon or Spectrum soil moisture sensors.

Features

Enables up to 8 sensors (in 2 groups of 4 sequentially sampled sensors)


Economical
to be connected using only 2 I/O module inputs

Status Indicator LEDs Indicate control signal status for each output

Simple plug-in connection to I/O Module and secured by single


Easy to Install
screw
Compatible with most sensors that can be directly interfaced to the
Compatibility
analog inputs on the Titan I/O module

PHONE: 604-538-3531 or 1-888-667-2091 (Canada and the US)  FAX: 604-538-4728  EMAIL: [email protected]
TTN-D8/MUX-4X2 Page 2

Specifications

Dimensions 4" x 2" x 1½" (length x width x height)


Module Power Consumption 2.5W @ 24VDC (supplied via Titan I/O module connection)
Max. Sensor Connections 8 (in 2 groups of 4)
Inputs used on I/O Module 2

Wiring Details

Typical Wiring Configuration


For installation, refer to the custom wiring diagrams supplied with each part.
Wire colors are shown for illustration purposes

Additional Information

For more information, please contact Argus.

www.arguscontrols.com

PHONE: 604-538-3531 or 1-888-667-2091 (Canada and the US)  FAX: 604-538-4728  EMAIL: [email protected]

Rev November 2012

You might also like