rt500 Manual
rt500 Manual
rt500 Manual
With RF
Instruction Manual
Model No RT500RF
PRODUCT COMPLIANCE
SALUS Controls Plc hereby declares that the radio equipment type
868Mhz is in compliance with Directives 1999/5/EC, 2014/53/EU,
2006/95/EC, 2004/108/EC, 2011/65/EU, 2009/125/EC and 93/68/
EEC. The full text of the EU declaration of conformity is available at
the following internet address: www.saluslegal.com
SAFETY INFORMATION
These instructions are applicable to the SALUS Controls model stated
on the front cover of this manual only, and must not be used with
any other make or model.
Please leave these instructions with the end user where they should
be kept in a safe place for future reference.
ErP RATING
This product has been rated as: Class 1, Efficiency 1%
INTRODUCTION
The RT500RF from SALUS Controls is a stylish and accurate 5/2 or 7 day programmable
electronic thermostat with a large, easy to read Liquid Crystal Display (LCD). This
programmable thermostat has been specifically designed to be used for both Volt Free
and AC heating applications. This programmable thermostat can replace most common
residential thermostats and is designed to be used with electric, gas or oil heating control
systems. Unlike ordinary single unit design thermostats, this is a new type of thermostat
separating the operational functions into two units.
The Receiver is used for wiring connections and heat on/off control. The Control Centre
provides the user interface and temperature sensing / control. The two units are linked
together by a Radio Frequency (RF) signal.
Features
• Volt free switching option
• 5/2 or 7 day programming flexibility
• Built-in start up programming for quick installation
• Frost protection
• Large, easy to read LCD with blue backlight
• Burner on symbol
• Easy to use programming
• User friendly
RECEIVER
RECEIVERWIRING
WIRING TERMINALS
TERMINALS
TerminalIdentifier
Terminal Identifier Description
Description
1 1 NO
NO Normally Open
Normally Open[N/O]
[N/O]
2 2 COM
COM Linked Live
Linked Live feed
feed(230V
(230VAC
ACheating
heatingapplications only)
applications only)
3 3 L L Live feed (230V AC)
Live feed (230V AC)
4 N Neutral
4 N Neutral
Notes:
• Receiver unit should have a permanent 230V AC main supply
• Confirm that the Boiler has an external thermostat loop and
is configured for 230V switching
• If the boiler has two terminals for the thermostat, remove the
link from the boiler
b. 24V Installation
Notes:
• Receiver unit should have a permanent 230V AC main supply
• Confirm that the Boiler has an external thermostat loop
and is NOT configured for 230V switching
• If the boiler has two terminals for the thermostat,
remove the link from the boiler
Jumper Function
Program Jumper for 5-2 (factory default setting) or 7
individual days programming.
Span Movable jumper for selecting temperature span
of ± 0.5°C (factory default setting) or ± 1.0°C
1,2,3,4,5 Removable jumpers for altering the RF address
code when used in conjunction with the
corresponding DIP switch on the Receiver.
NOTE: The Reset button must be pressed after changing jumper positions.
Disconnect any AC power to the Receiver, and remove the batteries from the
Control Centre before attempting any adjustment of the RF Address Code
switches and jumpers. If you are not sure how to carry out this operation
correctly, consult either with a qualified electrician or heating engineer.
To adjust the RF address code of the Receiver, simply push up one or more
of the 5 DIP switch levers on the DIP switch bank located on the back of the
receiver (the levers are numbered 1 to 5 from bottom to top, as shown in the
picture below), and then make a note of the setting of each switch:
For example, if the DIP switches on the Receiver were set as follows:
1 - ON
2 - OFF
3 - OFF
4 - OFF
5 - ON
Then you would need to remove jumper caps 2, 3 and 4 on the Control
Centre to make sure that they are both set with the same RF address code.
Please make sure that you keep any of the jumper caps you remove in a safe
place, in case you later need to change the RF address setting again.
You must press RESET on the Control Centre after making any changes to
the RF address code settings.
1. Press the UP button on the Control Centre until the set point
temperature is higher than room temperature by a few degrees.
2. Wait for a few seconds. The Burner on (heat call) indicator should
appear on the bottom left of the LCD on the Control Centre.
3. Check the green LED on the receiver unit - it should be lit.
4. Press the DOWN button to adjust the set point temperature to be
lower than room temperature.
5. Wait for a few seconds, and the Burner on (heat call) indicator
should disappear and the green LED should switch off.
6. If at step 3 the green LED is not illuminated, press the RESET button on
the Control centre and try to place the Control Centre closer
to the Receiver.
7. Repeat steps 1 to 5.
If you are unable to get a stable RF connection between the Receiver and
Control Centre, check that the Receiver is both switched on and has a mains
supply (red LED lit). If this isn’t the problem you can also alter the RF address
code by following the ‘RF Address Code Setting’ section of this manual, and
then repeat steps 1 to 5 (note that the RESET button on the Control Centre
should be pressed after altering the address code).
Once all the RT500RF units have been installed, if one unit then
seems to function abnormally, try changing the RF address code of
that unit’s Control Centre and its corresponding Receiver, making
sure that the new RF address code is different to all others in the
installation.
The Time and Day are displayed along with a SET indicator, with all other
indicators cleared from the display. The hour part of the time is flashing to
indicate that it is the currently selected item and is ready to be adjusted.
• Press the UP or DOWN keys to increase or decrease the ‘hour’ setting –
the
selected item will stop flashing while a key is pressed, and will resume
flashing when you release the key.
• Press the SELECT key to select the ‘minutes’ section of the time. Set the
minutes in the same way as the hour by using the UP and DOWN keys.
• Press SELECT again to select the Day, and again change the setting with
the UP and DOWN keys.
• Press the SET key to confirm the new time and day settings. This will store
the changes and return the RT500RF to Normal mode.
The RT500RF Control Centre will also return to Normal mode (and save the
To review or change a programme, press the SET key when the RT500RF is in
Normal mode. This will change the unit status to Programme Setting mode.
The LCD display will display programme number 1 and SET PROG, with all
other indicators cleared. The weekdays will be flashing to indicate they are
the selected item and are ready to be adjusted:
Press the SELECT key to confirm the Weekday or Weekend selection. Once
this is set, the ‘Hour’ will flash to indicate that it is the selected item and is
the next item to be adjusted:
…before then allowing you to cycle back to Programme 1. Pressing the SET
key at any time will confirm the setting and return to the programme set
selection.
To review or change a programme, press the SET key when the RT500RF is
in Normal mode. This will change the unit status to Programme Setting
mode.
The LCD display will display programme number 1 and SET PROG, with all
other indicators cleared. The weekdays will be flashing to indicate they are
the selected item and are ready to be adjusted.
Pressing the SET key at any time when in programming mode will return
the RT500RF into Normal mode. Press the SELECT key to confirm the Day
selection. Once this is set, the ‘Hour’ will flash to indicate that it is the
selected item and is the next item to be adjusted:
Pressing the SELECT key allows you to step through each of the items to be
reviewed or adjusted within the programmes in the following sequence:
TEMPORARY OVERRIDE
It is possible to temporarily override the current set temperature of the
RT500RF. There are two ways to do this:
Pressing the UP or DOWN key will increase or decrease the set point
temperature in 0.5 °C steps - the set point temperature can be adjusted
within a set range or 10 °C to 35 °C.
You can press SET at any time to confirm the new Temporary Override
setting and return to Normal mode, or press no keys at all and wait
approximately four seconds.
MAINTENANCE
The RT500RF programmable thermostat requires no special maintenance.
Periodically, the outer casing can be wiped clean using a dry cloth (please
DO NOT use solvents, polishes, detergents or abrasive cleaners, as these can
damage the thermostat).
There are no user serviceable parts within the unit; any servicing or repairs
should only be carried out by SALUS Controls or their appointed agents.
Should the RT500RF programmable thermostat fail to function correctly,
check:
• The batteries are the correct type, fitted correctly and are not exhausted
- fit new batteries if in doubt.
• Heating system is switched on.
• The RT500RF Receiver is switched on.
• If the RT500RF is still not functioning correctly, press the Reset Button.
WARRANTY
SALUS Controls warrants that this product will be free from any defect
in materials or workmanship, and shall perform in accordance with
its specification, for a period of two years from the date of purchase.
SALUS Controls sole liability for breach of this warranty will be (at its option)
to repair or replace the defective product.
Default Programmes
Programme Output Weekday Weekend
1 ON 6:00 AM 6:00 AM
TEMP 21 ºC 21 ºC
2 ON 8:00 AM 8:00 AM
TEMP 14 ºC 21 ºC
3 ON 4:00 PM 4:00 PM
TEMP 21 ºC 21 ºC
4 ON 6:00 PM 6:00 PM
TEMP 21 ºC 21 ºC
5 ON 10:00 PM 10:00 PM
TEMP 14 ºC 14 ºC
Temperature
Scale: Celsius
Range: 5 ºC to 35 ºC
Resolution: 0.5 ºC
Tolerance: Less than ± 0.5 ºC at 25 ºC
Display Range: 5.0 ºC to 45.0 ºC
Display Resolution: 0.5 ºC
Frost Protection
Setting: 5 ºC
Setpoint Temperature Range: 5 ºC to 35 ºC
Measured Air Temperature Range: 5 ºC to 45 ºC (Displayed on LCD)
If room temp is higher than 45C,will show HI on
the LCD, if less than 5C will show LO on the LCD
Control Centre
Power Source: 2 x AA alkaline batteries
(don’t use rechargeable batteries)
Receiver
Power Source: 230V AC / 50Hz
Switch Rating
Switching Voltage: 0 - 230V AC / 50Hz
Switching Current: 16A resistive, 5A inductive
Protection Rating: IP30
Environment
Operating Temperature: 0 ºC to + 40 ºC
Storage Temperature: - 10 ºC to + 60 ºC