Cleaning Overview
Cleaning Overview
Cleaning Overview
• Colloids: SDI
• Scalants: LSI, SI
• Organics: TOC
• Micro-organisms: CFU/ml
• Plant design
• Plant operation
• Membrane element
• Chemicals
• Cleaning procedures
• CIP equipment
Cleaning criteria
• First stage
colloidal fouling, organic fouling,
microbiological fouling
• Last stage
scaling, organic fouling,
microbiological fouling
Feed water source
• Well water:
– iron fouling, scaling
• City water:
– scaling, colloidal, organic, and microbiological fouling
• Surface water:
– scaling, colloidal, organic, and microbiological fouling
• Analyze feed water and concentrate sample
• Analyze cartridge filter residue or SDI filter residue
FILMTEC™ membranes
-pH and Temperature limits
Element type Max Temp Max Temp Max Temp Max Temp
50 C 45 C 35 C 25 C
(122 F) (113 F) (95 F) (77 F)
pH range pH range pH range pH range
flow
10 2% STPP+0.8%
NaEDTA@35C
0
pH 10 pH 11 pH 12
2.5
Relative change permeate flow
2 pH 1 is most
effective
1.5
0.5
0
2% citric [email protected] HCl@pH 2,35C HCl @ pH 1, HCl@ pH 1,
acid@pH 4, ,35C 25C 35C
40C
More
Less Effective
Effective
Citric acid concerns
• Cartridge filters
• Temperature controlled heating/cooling
• CIP tank should not have a flat bottom
• Concentrate and permeate return lines immersed (minimize foaming)
• Properly designed cleaning pump
CIP System
Concentrate
Permeate from Concentrate to to Drain
Cleaning Tank (Normal Operation)
Storage Tank
(Cleaning Operation)
®
Recommended feed flow rates during
high flow cleaning