Installation, Operation,

and Maintenance Manual


Model 3410
Table of Contents

Table of Contents
Introduction and Safety .......................................................................................................... 4
Introduction ............................................................................................................................. 4
Safety ...................................................................................................................................... 5
Safety terminology and symbols ............................................................................................. 5
Environmental safety .............................................................................................................. 6
User safety .............................................................................................................................. 6
Precautions before work ....................................................................................................... 7
Precautions during work ....................................................................................................... 7
Safety regulations for Ex-approved products in potentially explosive atmospheres ................ 8
Product approval standards .................................................................................................. 10
Product warranty ................................................................................................................... 11

Transportation and Storage ................................................................................................. 12


Inspect the delivery ............................................................................................................... 12
Inspect the package ........................................................................................................... 12
Inspect the unit ................................................................................................................... 12
Transportation guidelines ...................................................................................................... 12
Pump handling ................................................................................................................... 12
Lifting methods ................................................................................................................... 12
Storage guidelines ................................................................................................................ 15
Pump storage requirements ............................................................................................... 15

Product Description .............................................................................................................. 16


General description ............................................................................................................... 16
Nameplate information .......................................................................................................... 20

Installation ............................................................................................................................. 22
Preinstallation ....................................................................................................................... 22
Pump location guidelines .................................................................................................... 22
Foundation requirements ................................................................................................... 23
Set the baseplate .................................................................................................................. 23
Pump-to-driver alignment ...................................................................................................... 24
Alignment checks ............................................................................................................... 24
Align the pump using a straight edge .................................................................................. 25
Align the pump using a dial indicator .................................................................................. 26
Grout the baseplate .............................................................................................................. 27
Piping checklists ................................................................................................................... 28
General piping checklist ..................................................................................................... 28
Suction piping checklist ...................................................................................................... 29
Suction-piping valve considerations ................................................................................... 32
Discharge piping considerations ......................................................................................... 33
Pressure gauges ................................................................................................................ 33
Pump doweling ..................................................................................................................... 33

Commissioning, Startup, Operation, and Shutdown ......................................................... 34


Preparation for startup .......................................................................................................... 34
Pump priming ........................................................................................................................ 35
Fill the system ....................................................................................................................... 35
Start the pump ...................................................................................................................... 36
Operational checklist ............................................................................................................. 36
Check the rotation - Frame Mounted ..................................................................................... 37
Couple the pump and driver .................................................................................................. 38
Bearing lubrication ................................................................................................................ 38

Model 3410 Installation, Operation, and Maintenance Manual 1


Table of Contents

Lubricate the bearings with grease ..................................................................................... 38


Lubricate the bearings with oil (optional) ............................................................................ 38
Bar adjustment ................................................................................................................... 39
Seal the shaft with a packed stuffing box .............................................................................. 39
Mechanical seal options ........................................................................................................ 41
Connection of sealing liquid for a packed stuffing box .......................................................... 45
Connection of cooling water piping ....................................................................................... 45
Mechanical seal flushing and cooling .................................................................................... 46
Connection of drain piping .................................................................................................... 46
Pump priming ........................................................................................................................ 46
Start the pump ...................................................................................................................... 47
Pump operation precautions ................................................................................................. 47
Inspect the packed box after startup ..................................................................................... 48
Inspect the mechanical seal after startup .............................................................................. 48
Shut down the pump ............................................................................................................. 49
Make the final alignment of the pump and driver ................................................................... 50

Maintenance ........................................................................................................................... 51
Maintenance schedule .......................................................................................................... 51
Flood-damaged pumps ......................................................................................................... 52
Bearing maintenance ............................................................................................................ 52
Regrease the grease-lubricated bearings .......................................................................... 52
Lubricate the oil-lubricated bearings ................................................................................... 54
Bearing temperatures ......................................................................................................... 55
Bearing conditions .............................................................................................................. 55
Emergency ball bearing replacement ................................................................................. 55
Coupling lubrication ............................................................................................................ 55
Shaft-seal maintenance ........................................................................................................ 56
Packed stuffing box maintenance ....................................................................................... 56
Mechanical seal maintenance ............................................................................................ 56
Disassembly ......................................................................................................................... 57
Disassembly precautions ................................................................................................... 57
Drain the pump ................................................................................................................... 57
Remove the coupling guard ................................................................................................ 57
Remove the rotating element ............................................................................................. 60
Remove the bearings ......................................................................................................... 61
Remove the seals ............................................................................................................... 62
Remove the shaft sleeve .................................................................................................... 62
Remove the impeller ........................................................................................................... 62
Preassembly inspections ...................................................................................................... 63
Replace impeller wear rings ............................................................................................... 64
Radial clearances ............................................................................................................... 65
Reassembly .......................................................................................................................... 66
Install the impeller ............................................................................................................... 66
Assemble the rotating element ........................................................................................... 67
Install the bearings ............................................................................................................. 67
Install the rotating element ................................................................................................. 67
Assemble the casing .......................................................................................................... 67
Complete the assembly ...................................................................................................... 68
Bolt Torque Values - 3410 IOM .......................................................................................... 68
Spare parts ........................................................................................................................... 68

Troubleshooting .................................................................................................................... 70
Troubleshooting .................................................................................................................... 70

Parts Listings and Cross-Sectionals ................................................................................... 74


Drawings ............................................................................................................................... 74

2 Model 3410 Installation, Operation, and Maintenance Manual


Table of Contents

Parts list ................................................................................................................................ 75

Model 3410 Installation, Operation, and Maintenance Manual 3


Introduction and Safety

Introduction and Safety


Introduction
Purpose of this manual
The purpose of this manual is to provide necessary information for:
• Installation
• Operation
• Maintenance

CAUTION:
Failure to observe the instructions contained in this manual could result in personal injury and
property damage, and may void the warranty. Read this manual carefully before installing and
using the product.

NOTICE:
Save this manual for future reference and keep it readily available.

Requesting other information


Special versions can be supplied with supplementary instruction leaflets. See the sales
contract for any modifications or special version characteristics. For instructions, situations, or
events that are not considered in this manual or in the sales documents, please contact the
nearest ITT representative.
Always specify the exact product type and identification code when requesting technical
information or spare parts.

4 Model 3410 Installation, Operation, and Maintenance Manual


Introduction and Safety

Safety
WARNING:
• The operator must be aware of the pumpage and take appropriate safety precautions to
prevent physical injury.
• Risk of serious injury or death. If any pressure-containing device is over-pressurized, it can
explode, rupture, or discharge its contents. It is critical to take all necessary measures to
avoid over-pressurization.
• Risk of death, serious personal injury, and property damage. Installing, operating, or
maintaining the unit using any method not prescribed in this manual is prohibited.
Prohibited methods include any modification to the equipment or use of parts not provided
by ITT. If there is any uncertainty regarding the appropriate use of the equipment, please
contact an ITT representative before proceeding.
• Risk of injury and/or property damage. Operating a pump in an inappropriate application
can cause over pressurization, overheating, and/or unstable operation. Do not change the
service application without the approval of an authorized ITT representative.
• Running a pump without safety devices exposes operators to risk of serious personal
injury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed. See specific information about safety devices in other sections of this
manual.
• Risk of death, serious personal injury, and property damage. Heat and pressure buildup
can cause explosion, rupture, and discharge of pumpage. Never operate the pump with
suction and/or discharge valves closed.
• Never operate the pump with the suction valve closed.
• Precautions must be taken to prevent physical injury. The pump may handle hazardous
and/or toxic fluids. Proper personal protective equipment should be worn. Pumpage must
be handled and disposed of in conformance with applicable environmental regulations.

Safety terminology and symbols


About safety messages
It is extremely important that you read, understand, and follow the safety messages and
regulations carefully before handling the product. They are published to help prevent these
hazards:
• Personal accidents and health problems
• Damage to the product
• Product malfunction

Hazard levels
Hazard level Indication
A hazardous situation which, if not avoided, will
DANGER: result in death or serious injury

A hazardous situation which, if not avoided,


WARNING: could result in death or serious injury

A hazardous situation which, if not avoided,


CAUTION: could result in minor or moderate injury

Model 3410 Installation, Operation, and Maintenance Manual 5


Introduction and Safety

Hazard level Indication


• A potential situation which, if not avoided,
NOTICE: could result in undesirable conditions
• A practice not related to personal injury

Hazard categories
Hazard categories can either fall under hazard levels or let specific symbols replace the
ordinary hazard level symbols.
Electrical hazards are indicated by the following specific symbol:

Electrical Hazard:

These are examples of other categories that can occur. They fall under the ordinary hazard
levels and may use complementing symbols:
• Crush hazard
• Cutting hazard
• Arc flash hazard
The Ex symbol
The Ex symbol indicates safety regulations for Ex-approved products when used in
atmospheres that are potentially explosive or flammable.

Environmental safety
The work area
Always keep the pump station clean to avoid and/or discover emissions.

Recycling guidelines
Always recycle according to these guidelines:
1. If the unit or parts are accepted by an authorized recycling company, then follow local
recycling laws and regulations.
2. If the unit or parts are not accepted by an authorized recycling company, then return them
to the nearest ITT representative.

Waste and emissions regulations


Observe these safety regulations regarding waste and emissions:
• Dispose appropriately of all waste.
• Handle and dispose of the pumped fluid in compliance with applicable environmental
regulations.
• Clean up all spills in accordance with safety and environmental procedures.
• Report all environmental emissions to the appropriate authorities.

Reference for electrical installation


For electrical installation requirements, consult your local electric utility.

User safety
General safety rules
These safety rules apply:

6 Model 3410 Installation, Operation, and Maintenance Manual


Introduction and Safety

• Always keep the work area clean.


• Pay attention to the risks presented by gas and vapors in the work area.
• Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flash hazards.
• Always bear in mind the risk of drowning, electrical accidents, and burn injuries.

Safety equipment
Use safety equipment according to the company regulations. Use this safety equipment within
the work area:
• Helmet
• Safety goggles, preferably with side shields
• Protective shoes
• Protective gloves
• Gas mask
• Hearing protection
• First-aid kit
• Safety devices

Electrical connections
Electrical connections must be made by certified electricians in compliance with all internation-
al, national, state, and local regulations. For more information about requirements, see sections
dealing specifically with electrical connections.

Precautions before work


Observe these safety precautions before you work with the product or are in connection with
the product:
• Provide a suitable barrier around the work area, for example, a guard rail.
• Make sure that all safety guards are in place and secure.
• Make sure that the equipment is properly insulated when it operates at extreme
temperatures.
• Allow all system and pump components to cool before you handle them.
• Make sure that you have a clear path of retreat.
• Make sure that the product cannot roll or fall over and injure people or damage property.
• Make sure that the lifting equipment is in good condition.
• Use a lifting harness, a safety line, and a breathing device as required.
• Make sure that the product is thoroughly clean.
• Make sure that there are no poisonous gases within the work area.
• Make sure that you have quick access to a first-aid kit.
• Disconnect and lock out power before servicing.
• Check the explosion risk before you weld or use electric hand tools.

Precautions during work


Observe these safety precautions when you work with the product or are in connection with the
product:
• Never work alone.
• Always wear protective clothing and hand protection.
• Stay clear of suspended loads.
• Always lift the product by its lifting device.
• Beware of the risk of a sudden start if the product is used with an automatic level control.
• Beware of the starting jerk, which can be powerful.
• Rinse the components in water after you disassemble the pump.

Model 3410 Installation, Operation, and Maintenance Manual 7


Introduction and Safety

• Do not exceed the maximum working pressure of the pump.


• Do not open any vent or drain valve or remove any plugs while the system is pressurized.
Make sure that the pump is isolated from the system and that pressure is relieved before
you disassemble the pump, remove plugs, or disconnect piping.
• Never operate a pump without a properly installed coupling guard.
• Always bear in mind the risk of drowning, electrical accidents, and burn injuries.
• Never heat the condition monitor to temperatures in excess of 300°F (149°C).
• Never expose the condition monitor to open flames.
• Do not use the condition monitor in atmospheres containing acetic acid.
• Always wear protective gloves. The pump and condition monitor can be hot.
Wash the skin and eyes
1. Follow these procedures for chemicals or hazardous fluids that have come into contact with
your eyes or your skin:
Condition Action
Chemicals or hazardous 1. Hold your eyelids apart forcibly with your fingers.
fluids in eyes 2. Rinse the eyes with eyewash or running water for at least 15 minutes.
3. Seek medical attention.
Chemicals or hazardous 1. Remove contaminated clothing.
fluids on skin 2. Wash the skin with soap and water for at least 1 minute.
3. Seek medical attention, if necessary.

Safety regulations for Ex-approved products in potentially


explosive atmospheres
Description of ATEX
The ATEX directives are a specification enforced in Europe for electrical and non-electrical
equipment. ATEX deals with the control of potentially explosive atmospheres and the
standards of equipment and protective systems used within these atmospheres. The relevance
of the ATEX requirements is not limited to Europe. You can apply these guidelines to
equipment installed in any potentially explosive atmosphere.

Guidelines for compliance


Compliance is only fulfilled when the pump is operated within its intended use, for example
within its intended hydraulic range. The conditions of the service must not be changed without
approval of an authorized ITT representative. When installing or maintaining explosion-proof
pumps, follow these guidelines:
• Always install ATEX-approved equipment in compliance with the directive and applicable
standards (IEC/EN 60079–14).
• Do not install explosion proof products in locations that are classified as hazardous in the
national electric code, ANSI/NFPA 70–2005.

WARNING:
Risk of serious personal injury. Applying heat to impellers, propellers, or their retaining devices
can cause trapped liquid to rapidly expand and result in a violent explosion. This manual clearly
identifies accepted methods for disassembling units. These methods must be adhered to.
Never apply heat to aid in their removal unless explicitly stated in this manual.

If there are any questions regarding these requirements, the intended use, or if the equipment
requires modification, contact an ITT representative before you proceed.

Personnel requirements
ITT disclaims all responsibility for work done by untrained and unauthorized personnel.

8 Model 3410 Installation, Operation, and Maintenance Manual


Introduction and Safety

These are the personnel requirements for Ex-approved products in potentially explosive
atmospheres:
• All work on the product must be carried out by certified electricians and ITT-authorized
mechanics. Special rules apply to installations in explosive atmospheres.
• All users must know about the risks of electric current and the chemical and physical
characteristics of the gas and/or vapor present in hazardous areas.
• Any maintenance for Ex-approved products must conform to international and national
standards (for example IEC/EN 60079-17).

Product and product handling requirements


These are the product and product handling requirements for Ex-approved products in
potentially explosive atmospheres:
• Only use the product in accordance with the approved motor data stated on the
nameplates.
• The Ex-approved product must never run dry during normal operation. Dry running during
service and inspection is only permitted outside the classified area.
• Never start a pump without the proper priming.
• Before you start working with the product, make sure that the product and the control panel
are isolated from the power supply and the control circuit, so they cannot be energized.
• Do not open the product while it is energized or in an explosive gas atmosphere.
• Make sure that thermal contacts are connected to a protection circuit according to the
approval classification of the product.
• Intrinsically safe circuits are normally required for the automatic level-control system by the
level regulator if mounted in zone 0.
• The yield stress of fasteners must be in accordance with the approval drawing and the
product specification.
• Make sure that the equipment is properly maintained:
• Monitor the pump components and the end temperature of the liquid.
• Maintain proper bearing lubrication.
• Do not modify the equipment without approval from an authorized ITT representative.
• Only use parts that have been provided by an authorized ITT representative.

Equipment for monitoring


For additional safety, use condition-monitoring devices. Condition-monitoring devices include
but are not limited to these devices:
• Pressure gauges
• Flow meters
• Level indicators
• Motor load readings
• Temperature detectors
• Bearing monitors
• Leak detectors
• PumpSmart control system

Model 3410 Installation, Operation, and Maintenance Manual 9


Introduction and Safety

Product approval standards


Regular standards

WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure that the code classifications on the pump are compatible with the specific environment
in which the equipment is to be installed. If they are not compatible, do not operate the
equipment and contact an ITT representative before proceeding.

All standard products are approved according to CSA standards in Canada and UL standards
in USA. The drive unit degree of protection follows IP68. See the nameplate for maximum
submersion, according to standard IEC 60529.
All electrical ratings and performance of the motors comply with IEC 600341.

Explosion-proofing standards
All explosion-proof products for use in explosive atmospheres are designed in compliance with
one or more of the following approvals:
• EN, ATEX Directive 94/9/EC
• FM According to NEC
• Class 1 Div 1 Groups “C”, and “D”
• Class 2 Div 1 Groups “E”, “F”, and “G”
• Class 3 Div 1 Hazardous Locations
ATEX/IECEx:
• Group: IIC
• Category: Ex ia
• Temperature Class: T4 (for ambients up to 100ºC)
• ATEX Marking: Ex II 1 G

CSA certification
Intrinsically safe for:
• Class I, Div. 1, Groups A, B, C, D
• Class II, Div. 1, Groups E, F, G
• Class III
• Certified to Canadian and US requirements

10 Model 3410 Installation, Operation, and Maintenance Manual


Introduction and Safety

Product warranty
Coverage
ITT undertakes to remedy faults in products from ITT under these conditions:
• The faults are due to defects in design, materials, or workmanship.
• The faults are reported to an ITT representative within the warranty period.
• The product is used only under the conditions described in this manual.
• The monitoring equipment incorporated in the product is correctly connected and in use.
• All service and repair work is done by ITT-authorized personnel.
• Genuine ITT parts are used.
• Only Ex-approved spare parts and accessories authorized by ITT are used in Ex-approved
products.

Limitations
The warranty does not cover faults caused by these situations:
• Deficient maintenance
• Improper installation
• Modifications or changes to the product and installation made without consulting ITT
• Incorrectly executed repair work
• Normal wear and tear
ITT assumes no liability for these situations:
• Bodily injuries
• Material damages
• Economic losses

Warranty claim
ITT products are high-quality products with expected reliable operation and long life. However,
should the need arise for a warranty claim, then contact your ITT representative.

Model 3410 Installation, Operation, and Maintenance Manual 11


Transportation and Storage

Transportation and Storage


Inspect the delivery
Inspect the package
1. Inspect the package for damaged or missing items upon delivery.
2. Note any damaged or missing items on the receipt and freight bill.
3. File a claim with the shipping company if anything is out of order.
If the product has been picked up at a distributor, make a claim directly to the distributor.

Inspect the unit


1. Remove packing materials from the product.
Dispose of all packing materials in accordance with local regulations.
2. Inspect the product to determine if any parts have been damaged or are missing.
3. If applicable, unfasten the product by removing any screws, bolts, or straps.
For your personal safety, be careful when you handle nails and straps.
4. Contact your sales representative if anything is out of order.

Transportation guidelines
Precautions

WARNING:
• Stay clear of suspended loads.
• Observe accident prevention regulations in force.

Pump handling
WARNING:
Dropping, rolling or tipping units, or applying other shock loads, can cause property damage
and personal injury. Ensure that the unit is properly supported and secure during lifting and
handling.

CAUTION:
Risk of injury or equipment damage from use of inadequate lifting devices. Ensure lifting
devices (such as chains, straps, forklifts, cranes, etc.) are rated to sufficient capacity.

Lifting methods
WARNING:
• All lifting must be done in compliance with all applicable regulations/standards.
• Safe lifting points are specifically identified in this manual. It is critical to lift the equipment
only at these points. Integral lifting eyes or eye bolts on pump and motor components are
intended for use in lifting the individual components only.
• Lifting and handling heavy equipment poses a crush hazard. Use caution during lifting and
handling and wear appropriate Personal Protective Equipment (PPE, such as steel-toed
shoes, gloves, etc.) at all times. Seek assistance if necessary.
• Do not attach sling ropes to shaft ends.

The unit must be unloaded and handled by lifting equally at four or more points on the
baseplate. The lugs on the upper half casing are designed for lifting the upper half of the casing
only.

12 Model 3410 Installation, Operation, and Maintenance Manual


Transportation and Storage

Pumps mounted horizontally


Pump mounting Lifting method
A bare pump Place a nylon sling, chain, or wire rope around both bearing housings.
A pump mounted on a base that
has lifting holes WARNING:
If the driver has been mounted on the
baseplate at the factory, then it is safe to
lift the entire assembly.

CAUTION:
Take care to size equipment for unbal-
anced loads that may exist if the driver is
not mounted on the base at the time of
lifting. The driver may or may not be
mounted at the factory.

Attach nylon slings, chains, or wire rope to ANSI/OSHA Standard S


hooks. Then attach the hooks in the holes provided in the four corners
of the base. Make sure that the points of the hooks do not touch the
bottom of the pump base. Size the equipment for the load so that the
lift angle is less than 45° from the vertical.
A pump mounted on a base Place one sling around the outboard bearing housing and place
that does not have lifting holes the another sling around the back-end of the driver as close to
the mounting feet as possible. Make certain that the sling will
not damage the housing cover or conduit boxes. Join the free
ends of the slings together and place over the lifting hook.

1. Nylon sling, chain, or wire rope


2. Do not lift the entire pump with these lugs
3. Choker hitch around the bearing frame
Figure 1: The proper lifting method for a horizontal bare pump

Model 3410 Installation, Operation, and Maintenance Manual 13


Transportation and Storage

Figure 2: The proper lifting method for a horizontal pump on a base with lifting holes

Figure 3: The proper lifting method for a horizontal pump on a base without lifting holes

Pumps mounted vertically


Pump mounting Lifting method
Half pedestal Place a nylon sling chain or wire rope around both flanges. Use a latch
hook or standard shackle and end loops. Be sure the lifting equipment
is long enough to keep the lift angle less than 30° from the vertical.
Full pedestal Install eyebolts in the three holes provided at the top of the support
and tighten securely. Attach a chain or wire rope using a latch hook or
standard shackle and end loop. You must use shoulder eyebolts that
are manufactured per ANSI B18.15 and sized to fit the holes provided.
Be sure the lifting equipment is long enough to keep the lift angle less
than 30° from the vertical.

1. Nylon sling, chain, or wire rope


Figure 4: The proper lifting method for a vertical pump mounted on a half pedestal

14 Model 3410 Installation, Operation, and Maintenance Manual


Transportation and Storage

1. Nylon sling, chain, or wire rope


Figure 5: The proper lifting method for a vertical pump mounted on a full pedestal

Storage guidelines
Pump storage requirements
Storage requirements depend on the amount of time that you store the unit. The normal
packaging is designed only to protect the unit during shipping.
Length of time in storage Storage requirements
Upon receipt/short-term (less than six months) • Store in a covered and dry location.
• Store the unit free from dirt and vibrations.
Long-term (more than six months) • Store in a covered and dry location.
• Store the unit free from heat, dirt, and vibra-
tions.
• Rotate the shaft by hand several times at least
every three months.

Treat bearing and machined surfaces so that they are well preserved. Refer to drive unit and
coupling manufacturers for their long-term storage procedures.
You can purchase long-term storage treatment with the initial unit order or you can purchase it
and apply it after the units are already in the field. Contact your local ITT sales representative.

Model 3410 Installation, Operation, and Maintenance Manual 15


Product Description

Product Description
General description
Product description
Goulds Model 3410 is a single-stage, double-suction pump with the following capabilities:
Measurement Maximum tolerance
Capacity 12,000 gpm (45,425 lpm)
Head 530 ft (161 m)
Pressure • Cast iron: 175 psig (1,200 kPa)
• Ductile iron or steel: 250 psig (1,725 kPa)
Temperature 350°F (177°C)

Pump sizes with an H designation are designed for a higher flow than the equivalent size
standard pump. External casing dimensions are the same, but the H pumps have wider casing
cutwaters and impellers.
The complete model line has four different shafts with only two bearing assemblies. Standard
constructions are all-iron, bronze fitted, 316SS fitted, and all 316SS. Other constructions are
available upon request.
Right-hand rotation is standard. Left-hand rotation is available as an option. The rotation can be
changed after installation without any additional parts.

Vertical application
Model 3410 is available in a vertical configuration (3410V). This arrangement is ideal for
applications with limited space such as shipboard service. A rugged fabricated-steel frame
supports the pump and driver, providing a machined fit for positive alignment when using
standard P-base motors.

Figure 6: Vertical configuration

WARNING:
Leakage of pumped liquid can create an explosive environment. Make sure that the pumped
liquid is compatible with all pump materials it comes in contact with.

16 Model 3410 Installation, Operation, and Maintenance Manual


Product Description

Casing
The casing is split horizontally. The upper and lower halves are held together with capscrews
and studs on the side of each stuffing box to aid in disassembly and reassembly. The casing is
supported by integrally cast feet. Separate bearing housings are attached directly to machined
fits in each end of the casing with capscrews.
Fourteen of the 27 casings are double volute as follows:
• 4x6-11
• 4x6-11H
• 6x8-11
• 8x10-21
• 8x10-12
• 8x10-14
• 8x10-17
• 8x10-17H
• 10x12-12
• 10x12-12H1
• 10x12-14
• 10x12-17
• 10x12-15
• 12x14-14
• 12x14-15
Flanged suction and discharge connections are located in the lower half of the casing and
conform to ANSI 16.1/16.5 class 125/150. The 125# flat-face flanges are standard with 250#
flat-face available as an option.
DIN flanges may also be provided on all sizes except the 6x8-22. The flanges are provided in
accordance with EN 1092-2. These flanges are smooth, flat faced and meet or exceed the
minimum thickness required by the PN rating. The flanges provided are PN16 on smaller sizes
and PN10 on the larger sizes.
The casings are standard with the following parts:
• Two jackscrews (except S group)
• Two lifting lugs
• Two tapered dowel pins for alignment
• One 0.030 in. (0.0762 cm) parting gasket
The upper-half casing has a vent connection, a priming connection, and two stuffing box seal
ring connections. The lower half has two drain connections.

Impeller
• Enclosed, double suction
• Axial hydraulic balance
• Key driven
• Dynamically balanced, when the diameter to width ratio is less than six

Wear rings
• Casing wear rings are supplied as standard to maintain proper running clearance and to
minimize leakage between the suction and discharge chambers in the casing. Each casing
ring is held in place by a single anti-rotation pin located in a milled slot at the horizontal
parting surface.

1 This casing uses a partial splitter.

Model 3410 Installation, Operation, and Maintenance Manual 17


Product Description

• Optional impeller wear rings are available on all pump sizes. The impeller wear rings are
held in position by axial setscrews. Field installation of impeller rings requires a
remachining of the impeller hubs.
• The casing rings remain the same for designs with or without impeller rings.

Shaft
The shaft is a heavy-duty design that minimizes deflection and vibration. The shaft deflection is
a maximum of 0.002 in. (0.051 mm) at the stuffing box face under the worst operating
conditions. The shaft on M, L, and XL group pumps is completely dry with gasket seals
between the impeller hubs and shaft sleeves. The S group does not have a completely dry
shaft. The S group is standard with a 420 stainless steel shaft. The M, L, and XL sizes have an
ANSI 4140 steel shaft standard with an option for 316 stainless steel.

Shaft sleeves
The M, L and XL group pumps have standard shaft sleeves. They are keyed to the shaft at the
impeller and held axially in place using threaded sleeve nuts. The S group pumps are standard
without shaft sleeves, but sleeves are available.

Stuffing box
Non-asbestos stuffing box packing is standard. The stuffing box contains split lantern rings and
renewable stuffing box throat bushings. Tapped openings are provided for water sealing from
either the pump casing or an outside source. Bypass piping is optional. Two-piece, investment
cast, 316 stainless steel, non-quench glands are standard on all 3410 pumps.

Mechanical seals
• Mechanical seals are available as an option on the Model 3410. Oversize stuffing box
bores are standard on pumps with factory-installed mechanical seals. This provides
greater flexibility and an improved operating environment.
• Pumps that are supplied with standard packed boxes can be converted to mechanical
seals in the field. This conversion requires either remachining of the stuffing box to
accommodate the mechanical seal or remachining of the gland to adapt to the existing
stuffing box. If the stuffing box bores are remachined, then all standard Model 3410
mechanical seals and the standard I.D. pilot glands can be used.
• Balanced seals require conversion to stepped sleeves. Most unbalanced mechanical seals
will fit in the standard packed box bores, but this requires remachining the I.D. pilot off the
glands. In this case, the glands must be centered on the shaft or the sleeve using a feeler
gauge.
• Pumps supplied with mechanical seals can also be converted to packed boxes in the field.
A cartridge conversion kit is available and includes a box of fittings plus sleeves to convert
oversize bores to standard packed-box bores.

Bearings
• The Model 3410 is standard with double-row ball thrust bearings and a single-row deep
groove ball bearing at the coupling end. There are only two sizes of bearing housings and
bearings used on the Model 3410 product line. The S and M groups use identical bearings,
as do the L and XL groups. The thrust bearing is held in position with a tapered snap ring
and is locked in the thrust bearing housing to take any unbalanced axial thrust load. The
radial bearing is free to float axially in the bearing housing taking radial loads only.
• Grease lubrication is standard. Oil lubrication is optional and uses the same shaft,
bearings, and bearing housings. Bearing cooling is available with oil lubrication only and is
required for temperatures over 250°F (121°C). The bearing housings are completely
sealed by Inpro VBS bearing isolators.

18 Model 3410 Installation, Operation, and Maintenance Manual


Product Description

Bedplates
Cast iron bedplates are furnished as standard. They include a drip collection chamber with a
tapped drain connection and an opening suitable for grouting. Fabricated steel bedplates are
available as an option.

Intended applications
The Goulds 3410 model line is designed for a wide range of industrial, municipal, and marine
services, which includes:
• Process – Quench water, stripper bottoms, reboiler circulation, and cooling tower
• Pulp and paper – Primary and secondary cleaner, filtrate, mill water supply, and fan pump
• Primary metals – Cooling water, quench, and leaching
• Municipal – High lift, low lift, wash water, waste water, and raw water
• Utilities – Cooling tower, component cooling, and service water
• Marine – Bilge and ballast, cargo, cooling service, and fire pump

Model 3410 Installation, Operation, and Maintenance Manual 19


Product Description

Nameplate information
Important information for ordering
Every pump has a nameplate that provides information about the pump. The nameplate is
located on the pump casing.
When you order spare parts, identify this pump information:
• Model
• Size
• Serial number
• Item numbers of the required parts
Refer to the nameplate on the pump casing for most of the information. See Parts List for item
numbers.

Nameplate types
Nameplate Description
Pump casing Provides information about the hydraulic characteristics of the pump.
Pump The formula for the pump size is: Discharge x Suction - Nominal Maximum Impeller Diameter in inches.
(Example: 2x3-8)
ATEX If applicable, your pump unit might have an ATEX nameplate affixed to the pump, the baseplate, or the
discharge head. The nameplate provides information about the ATEX specifications of this pump.

Nameplate on the pump casing using English units

Figure 7: Nameplate on the pump casing using English units


Table 1: Explanation of nameplate on the pump casing
Nameplate field Explanation
S/N Goulds serial number
Model Pump model
Size Size of the pump
Std. Dim Standard Dimensional designation
Hydro Pressure Hydrostatic pressure at 70°F, in pounds per square inch
Max. Design Working Maximum working pressure in pounds per square inch
Press.
RPM Rated pump speed, in revolutions per minute
Head
Material Pump material
Impeller Diameter Impeller trim diameter
Cont/Item No Purchaser's contract or item number
Max. Dia Impeller maximum diameter
Nameplate field Explanation
MODEL Pump model
SIZE Size of the pump

20 Model 3410 Installation, Operation, and Maintenance Manual


Product Description

Nameplate field Explanation


FLOW Rated pump flow, in gallons per minute
HEAD Rated pump head, in feet
RPM Rated pump speed, in revolutions per minute
HYDRO PRESS Hydrostatic pressure at 100°F, in pounds per square inch
MAX. DES. WORKING PRESS Maximum working pressure at temperature °F, in pounds per square inch
S/N Serial number of the pump
CONT./ITEM NO. Customer contract or item number
IMP. DIA. Rated impeller diameter
MAX. DIA. Maximum impeller diameter
STD. DIM. Standard ANSI dimensional code
MAT'L Material of construction

ATEX nameplate

Figure 8: ATEX nameplate


Nameplate field Explanation
II Group 2
2 Category 2
G/D Pump can be used when gas and dust are present
T4 Temperature class

WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure that the code classifications on the pump are compatible with the specific environment
in which the equipment is to be installed. If they are not compatible, do not operate the
equipment and contact an ITT representative before proceeding.

Model 3410 Installation, Operation, and Maintenance Manual 21


Installation

Installation
Preinstallation
Precautions

WARNING:
• When installing in a potentially explosive environment, ensure that the motor is
properly certified.
• All equipment being installed must be properly grounded to prevent unexpected
discharge. Discharge can cause equipment damage, electric shock, and result in serious
injury. Test the ground lead to verify it is connected correctly.

NOTICE:
• Supervision by an authorized ITT representative is recommended to ensure proper
installation. Improper installation may result in equipment damage or decreased perfor-
mance.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state and local regulations.

Pump location guidelines


Guideline Explanation/comment
Keep the pump as close to the liquid source as This minimizes the friction loss and keeps the
practically possible. suction piping as short as possible.
Make sure that the space around the pump is suffi- This facilitates ventilation, inspection, mainte-
cient. nance, and service.
If you require lifting equipment such as a hoist or This makes it easier to properly use the lifting
tackle, make sure that there is enough space above equipment and safely remove and relocate the
the pump. components to a safe location.
Protect the unit from weather and water damage due This is applicable if nothing else is specified.
to rain, flooding, and freezing temperatures.
If the possibility of freezing exists during a shutdown
period, then drain the pump completely and use
compressed air to blow out all passages and pockets
where liquid might collect.
Do not install and operate the equipment in closed Acceptable devices:
systems unless the system is constructed with proper- • Pressure relief valves
ly-sized safety devices and control devices.
• Compression tanks
• Pressure controls
• Temperature controls
• Flow controls
If the system does not include these devices,
consult the engineer or architect in charge before
you operate the pump.
Take into consideration the occurrence of unwanted The best pump location for noise and vibration
noise and vibration. absorption is on a concrete floor with subsoil
underneath.
If the pump location is overhead, undertake special Consider a consultation with a noise specialist.
precautions to reduce possible noise transmission.
When possible, locate the pump below the fluid level. This facilitates priming, ensures a steady flow of
liquid, and provides a positive suction head on
the pump.
Make sure there is a suitable power source available If the pump is motor-driven, then the electrical
for the pump driver. characteristics of the power source should be
identical to those shown on motor data plate.

22 Model 3410 Installation, Operation, and Maintenance Manual


Installation

The installation must be evaluated to determine that the Net Positive Suction Head Available
(NPSHA) meets or exceeds the Net Positive Suction Head Required (NPSHR), as stated by the
pump performance curve.

Foundation requirements
Requirements
• The foundation must be able to absorb any type of vibration and form a permanent, rigid
support for the unit.
• The foundation must weigh at least five times the weight of the pump unit.
• Provide a flat, substantial concrete foundation in order to prevent strain and distortion
when you tighten the foundation bolts.

Foundation bolts
• Foundation bolts must be embedded in the concrete to a depth of 8âM M 12 in. (20âM M 30
cm) and locked with either a hook around a reinforcing bar or a nut and washer at the
bottom.
• Foundation bolts must have a sleeve around them at least six times the bolt diameter in
length and at least two bolt sizes larger in ID.
• If a nut and washer are used for locking, then the washer must have an OD two sizes
larger than the sleeve.
• Foundation bolts must be sized 0.125 in. (3.175 mm) less than the anchor bolt holes in the
base.

Bolt installation diagram

1. Baseplate
2. Grout
3. Alternate bolt and washer
4. Concrete
5. Bolt sleeve
Figure 9: Bolt installation

Set the baseplate


Pumps are checked at the factory for the ability to be aligned to the required tolerances. Due to
the flexibility of an ungrouted base and handling in shipment, do not assume that the unit is in
alignment when it is placed on the rough foundation. If these directions are followed, then the
required alignment must be readily achieved.
1. Perform the initial or rough alignment.
Rough alignment is designated as 0.020 in. (0.051 cm) TIR for parallel alignment and 0.009
in. (0.023 cm) TIR per inch of radius for angular alignment. Use blocks at the anchor bolts
and midway between to position the bottom of the base at a finished height with the

Model 3410 Installation, Operation, and Maintenance Manual 23


Installation

foundation bolts extending through the holes in the baseplate. Instead of blocks and shims,
you can also use metal wedges with a small taper.
2. If the unit has a non-flexible coupling, such as a Falk Gear coupling, then disconnect the
coupling halves.
This is usually not necessary on flexible-type couplings, such as Wood’s Sure-Flex
coupling.
3. Tighten all pump and motor bolts.
This ensures that bolts have not loosened or that a soft foot has not occurred due to base
distortion during shipment. A soft foot causes a change in the alignment when one bolt is
loosened.
4. If the driver is being installed in the field, then make sure it is centered in its bolt holes with
shims added to bring the driver into rough alignment with the pump.
Move the pump also, if necessary.

NOTICE:
Risk of improper alignment. Do not use more than six shims and use the thickest shims
possible. Place thin shims in between thick shims.

5. Level and plumb the pump shaft, coupling faces, and flanges by adding or removing shims
between the blocks and the bottom of the base.
6. Hand-tighten the anchor bolt nuts. Then tighten the nuts with a wrench, taking care not to
distort the base.
Do not reconnect the non-flexible coupling until after you complete the alignment operation.
The baseplate does not need to be level.
7. After the foundation bolts are lightly torqued, recheck the alignment requirements.
If the alignment must be corrected, then add or remove shims or wedges under the
baseplate.

Pump-to-driver alignment
Precautions

WARNING:
• Misalignment can cause decreased performance, equipment damage, and even catas-
trophic failure of frame-mounted units leading to serious injury. Proper alignment is the
responsibility of the installer and the user of the unit. Check the alignment of all drive
components prior to operating the unit.
• Follow the coupling installation and operation procedures from the coupling manufactur-
er.
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM)
for specific instructions and recommendations.

Alignment checks
When to perform alignment checks
You must perform alignment checks under these circumstances:
• The process temperature changes.
• The piping changes.
• The pump has been serviced.

24 Model 3410 Installation, Operation, and Maintenance Manual


Installation

Types of misalignment
Type of misalignment Description
Angular misalignment Shafts have an axis concentric at the intersection but not parallel.
Parallel offset misalignment Shafts have an axis parallel but offset.

Check and correct angular misalignment before correcting parallel misalignment.

Permissible coupling misalignment


Type of misalignment Single element coupling Double element (spacer) coupling
Parallel misalignment 0.1 mm | 0.004 in. TIR (4 mils) 1.52 mm | 0.060 in. TIR per foot of
spacer length
Angular misalignment 0.1 mm | 0.004 in. TIR per inch of 0.51 mm | 0.002 in. TIR per inch of
radius. radius

Types of alignment checks


Type of check When it is used
Initial alignment (cold alignment) Prior to operation when the pump and the driver are at ambient
check temperature.
Final alignment (hot alignment) After operation when the pump and the driver are at operating
check temperature.

To make the final alignment, move and shim the motor on its base until the coupling hubs are
within the recommended tolerances measured in total runout. Take all measurements with the
pump and driver bolts tightened. Make the final alignment check after the unit has attained its
final operating temperature.

Initial alignment (cold alignment) checks


When Why
Before you grout the baseplate This ensures that alignment can be accomplished.
After you grout the baseplate This ensures that no changes have occurred during the grouting
process.
After you connect the piping This ensures that pipe strains have not altered the alignment.

Final alignment (hot alignment) checks


When Why
After the first run This ensures correct alignment when both the pump and the driver
are at operating temperature.
Periodically This follows the plant operating procedures.

Cold settings for parallel vertical alignment


Introduction
This section shows the recommended preliminary (cold) settings for electric motor-driven
pumps based on different temperatures of pumped fluid. Consult driver manufacturers for
recommended cold settings for other types of drivers such as steam turbines and engines.

Recommended settings
Pumped fluid temperature Recommended setting for driver shaft
Ambient 0.05 mm | 0.002 in. to 0.102 mm | 0.004 in., low
38°C | 100°F 0.00 mm | 0.000 in. to 0.05 mm | 0.002 in, high
93°C | 200°F 0.102 mm | 0.004 in. to 0.152 mm | 0.006 in., high
149°C | 300°F 0.203 mm | 0.008 in. to 0.254 mm | 0.010 in., high
204°C | 400°F 0.305 mm | 0.012 in. to 0.356 mm | 0.014 in., high

Align the pump using a straight edge


Before you begin, you must have a straight edge and a taper gauge or set of feeler gauges.

Model 3410 Installation, Operation, and Maintenance Manual 25


Installation

Only use this method if the face and outside diameters of the coupling halves are square and
concentric with the coupling bores. If this condition does not exist or elastomeric couplings do
not make this method convenient, then use the dial indicator method.
1. Check for angular alignment by inserting the taper or feeler gauges between the coupling
faces at 90° intervals.
The unit is in angular alignment when these four measurements are the same or are within
recommended tolerances.
2. Check for parallel alignment by placing a straight edge across both coupling rims on all four
sides.
The unit is in parallel alignment when the straight edge rests evenly across both coupling
rims in all four positions.

1. Feeler gauge
Figure 10: Incorrect angular alignment

1. Straight edge
Figure 11: Incorrect parallel alignment

1. Straight edge
2. Feeler gauge
Figure 12: Correct alignment

Align the pump using a dial indicator


Before you begin, you must have a dial indicator with a mounting magnet and extension bars.
A dial indicator can provide more accurate alignment than a straight edge.
1. Fasten the indicator stand or magnetic base to the pump half of the coupling.
2. Adjust the assembly until the indicator button is resting on the periphery of the other
coupling half.
3. Set the dial to zero and use chalk to mark the coupling half where the button rests. Then
place a separator between the coupling halves so that the bearing slack does not affect the
readings.
Chalk and separators are not necessary on the elastomeric couplings that have not been
disconnected.
4. Rotate both shafts by the same amount.

26 Model 3410 Installation, Operation, and Maintenance Manual


Installation

All readings must be made with the button on the chalk mark.
The dial readings will indicate whether the driver must be raised, lowered, or moved to
either side. You can accurately align the shaft centers with this method even where faces or
outside diameters of the coupling are not square or concentric with the bores.

NOTICE:
Risk for rotation unbalance. Any gross deviation in squareness or concentricity must be
corrected.

5. After each adjustment, recheck both parallel and angular alignments.

1. Dial indicator
2. Reference mark
3. Separator to take up the bearing slack
Figure 13: Angular alignment

1. Dial indicator
2. Reference mark
3. Separator to take up the bearing slack
Figure 14: Parallel alignment

Grout the baseplate


CAUTION:
Do not grout until the initial alignment is made.

Grout compensates for an uneven foundation. Together with the baseplate, grout makes a very
rigid interface between the pump and the foundation by distributing the weight over the length
of the base and preventing shifting. Use an approved, non-shrinking grout such as Embeco 636
or 885 by Master Builders, Cleveland, Ohio, or the equivalent.

Model 3410 Installation, Operation, and Maintenance Manual 27


Installation

1. Baseplate
2. Shims
3. Form
4. Concrete
5. Anchor bolt
6. Bolt sleeve
7. Grout
Figure 15: Baseplate grouting
1. Build a strong form around the foundation to contain the grout.
2. Soak the top of the foundation thoroughly, then remove surface water.
3. Completely fill the baseplate with grout.
If necessary, temporarily use air relief tubing or drill vent holes in order to remove trapped
air.
4. After the grout has completely hardened, tighten the foundation bolts.
It will take approximately 24 hours for the grout to harden.
5. Check the alignment.
6. Approximately fourteen days after the grout has been poured and the grout has completely
dried, apply an oil-based paint to the exposed edges of the grout in order to prevent air and
moisture from coming in contact with the grout.

Piping checklists
General piping checklist
Precautions

CAUTION:

Do not move the pump to the pipe. This could make final alignment impossible.

CAUTION:
Flange loads from the piping system, including those from the thermal expansion of the
piping, must not exceed the limits of the pump. Casing deformation can result in contact with
rotating parts, which can result in excess heat generation, sparks, and premature failure.

28 Model 3410 Installation, Operation, and Maintenance Manual


Installation

NOTICE:
Vary the capacity with the regulating valve in the discharge line. Never throttle the flow from the
suction side. This action can result in decreased performance, unexpected heat generation,
and equipment damage.

Piping guidelines
Guidelines for piping are given in the Hydraulic Institute Standards available from the Hydraulic
Institute at 9 Sylvan Way, Parsippany, NJ 07054-3802. You must review this document before
you install the pump.

Checklist
Check Explanation/comment Checked
Check that all piping is supported This helps to prevent:
independently of, and lined up • Strain on the pump
naturally with, the pump flange.
• Misalignment between the pump and the drive unit
• Wear on the pump bearings, seal, and shafting
Keep the piping as straight as This helps to minimize friction losses.
possible. Avoid unnecessary
bends. Use 45° or long radius 90°
fittings where necessary.
Check that only necessary fittings This helps to minimize friction losses.
are used.
Make sure that the inside diame- —
ters match properly when you use
flange joints.
Do not connect the piping to the —
pump until:
• The grout for the baseplate
or sub-base becomes hard.
• The hold-down bolts for the
pump are tightened.
Make sure that all the piping joints This prevents air from entering the piping system or
and fittings are airtight. leaks that occur during operation.
If the pump handles corrosive
fluids, make sure that the piping
allows you to flush out the liquid
before you remove the pump.
If the pump handles liquids at This helps to prevent misalignment due to thermal
elevated temperatures, make expansion of the piping.
sure that the expansion loops and
joints are properly installed.
Make sure that all piping compo- —
nents, valves and fittings, and
pump branches are clean prior to
assembly.

Suction piping checklist


The sizing and installation of the suction piping is extremely important. It must be selected and
installed so that pressure losses are minimized and sufficient liquid flows into the pump when it
is started and operated. Many NPSH problems can be directly attributed to improper suction
piping systems.

CAUTION:
• Flange loads from the piping system, including those from the thermal expansion of the
piping, must not exceed the limits of the pump. Deformation can result in contact with
rotating parts, which can result in excess heat generation, sparks, and premature failure.
• Air pockets can form in the top of the reducer and the pipe when operating on suction lift.
Never use a concentric reducer in a horizontal line.

Model 3410 Installation, Operation, and Maintenance Manual 29


Installation

Piping checklist
Check Explanation/comment Checked
Check that the elbows in the suction When there is an elbow in a position other than
piping for horizontal double-suction the vertical when in relation to the pump suction
pumps are installed per the Hydraulics nozzle, this causes more liquid to enter one side
Institute Standards since there is al- of the impeller than the other. The result is highly
ways an uneven turbulent flow around unequalized thrust loads that overheat the bear-
an elbow. ings and cause rapid wear, which adversely
affects the hydraulic performance. See the Ex-
ample of unbalanced loading figure.
Check that pipe reducers on the inlet This avoids excessive turbulence and noise.
side have no more than one pipe
diameter reduction in a single reducer.
When operating on a suction lift, check A horizontal suction line must have a gradual
that the suction pipe slopes upward to rise to the pump. Any high point in the pipe can
the pump nozzle. become filled with air and prevent proper opera-
tion of the pump.
(Optional) You can install a short sec- This facilitates the cleansing of the liquid pas-
tion of pipe adjacent to the suction sage of the pump without dismantling the pump.
flange such as Dutchman or a spool With this arrangement, anything that clogs the
piece that is designed so that it can be impeller is accessible with the removal of the
readily dropped out of the line. spool piece or pipe section.

Example of unbalanced loading

CAUTION:
Risk of excessive axial load or cavitation. Do not install an elbow directly before the suction of
a double suction pump if the plane of the suction is parallel to the pump shaft. Alternatively,
install an elbow with straightening vanes to help evenly distribute the flow.

This figure shows the unbalanced loading of a double-suction impeller due to the uneven flow
around an elbow that is adjacent to the pump:

1. Pump casing
2. Impeller
3. Pump suction flange
4. Suction elbow
5. Water velocity increases here and causes a greater flow to one side of the impeller.
Figure 16: Unbalanced loading of double-suction impeller

30 Model 3410 Installation, Operation, and Maintenance Manual


Installation

Examples

1. Level centerline of pipe


2. Check valve
3. Gate valve
4. Increaser
Figure 17: Suction pipe installed with a gradual rise to the pump – correct

1. Air pocket
Figure 18: Suction pipe installed with a gradual rise to the pump – incorrect

1. Air pocket
Figure 19: Suction pipe installed with a reducer – incorrect

1. Air pocket
Figure 20: Incorrect

1. No air pockets
2. Gradual rise
Figure 21: Correct

Model 3410 Installation, Operation, and Maintenance Manual 31


Installation

1. No air pockets
2. Eccentric reducer
3. Gradual rise
Figure 22: Gradual rise to the pump – correct

1. Distance plus eccentric reducer straightens the flow


Figure 23: Suction pipe above the pump – correct

1. Path of the water


Figure 24: Suction pipe above the pump – incorrect

Suction-piping valve considerations


Suction valves

CAUTION:
Never throttle the flow from the suction side. Only use suction valves to isolate the pump for
maintenance, and install such valves in positions to avoid air pockets.

Before you install suction valves in the suction piping, review these considerations:
• Make sure that the suction piping valves are placed right before the run of recommended
straight pipe.
• Never throttle the pump with the use of a valve on the suction side of the pump.
• Only use suction valves to isolate the pump for maintenance purposes.
• Always install the valve in a position that avoids the formation of air pockets.

Foot valves
If the pump operates under static suction lift conditions, you can install a foot valve in the
suction line in order to avoid the necessity of priming each time you start the pump.
Before you install foot valves in the suction piping, review these considerations:
• Make sure this valve is of the flapper type, rather than the multiple spring type, and that it is
sized to avoid excessive friction in the suction line.
• Size the foot valve and pipe in order to maximize NPSHA to the pump by minimizing
suction line losses.
• When foot valves are used, or where there are other possibilities of water hammer, close
the discharge valve slowly before you shut down the pump.

32 Model 3410 Installation, Operation, and Maintenance Manual


Installation

Check valves
In normal applications, check valves are placed in the discharge piping. Before you use a
check valve in the suction piping, consider the added pressure drop to the pump, the potential
of water hammer, and the chance of allowing the entire pump volute to be exposed to the
discharge pressure.

Gate valves
Where two or more pumps are connected to the same suction line, install gate valves so that
any pump can be isolated from the line.
Before you install gate valves, review these considerations:
• Always install gate valves on the suction side of the pumps with a positive pressure for
maintenance purposes.
• Always install gate valves with the stems in a horizontal position to avoid air pockets.
• Globe valves should not be used, particularly where NPSH is critical.

Discharge piping considerations


Before you construct discharge piping, review these considerations:
• If the discharge piping is short, then the pipe diameter can be the same as the discharge
opening.
• If the piping is long, then the pipe diameter should be one or two sizes larger than the
discharge opening.
• On long horizontal runs, it is desirable to maintain the most even grade possible.
• Avoid high spots, such as loops. High spots will collect air and throttle the system or lead to
erratic pumping.
• A check valve and an isolating gate valve should be installed in the discharge line.
• The check valve is placed between the pump and the gate valve. This protects the
pump from excessive backpressure and prevents liquid from running back through the
pump in case of power failure.
• The gate valve is used for priming and starting and also shutting down the pump.

Pressure gauges
Install properly sized pressure gauges in both the suction and discharge nozzles in the gauge
taps provided. The gauges enable the operator to observe the operation of the pump and to
determine whether the pump is operating in conformance with the performance curve. If
cavitation, vapor binding, or other unstable operations occur, then widely fluctuating discharge
pressure will be noted.

Pump doweling
Pump units can be doweled on diagonally opposite feet. Do not do this until the unit has run for
a sufficient length of time and alignment is within the required alignment tolerance.

Model 3410 Installation, Operation, and Maintenance Manual 33


Commissioning, Startup, Operation, and Shutdown

Commissioning, Startup, Operation, and


Shutdown
Preparation for startup
WARNING:
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM)
for specific instructions and recommendations.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Running a pump without safety devices exposes operators to risk of serious personal
injury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.
• Check the rotation of the power unit and pump in relation to that of the drive as shown by
the arrows on the case. Rotate the drive manually before you apply power-checking
rotation. Do not operate in the reverse direction of these arrows as serious damage or
injury can occur.

CAUTION:
• Serious damage to the pump may result if it is started dry. Make sure that the pump is
completely filled with liquid before it is started.

System flushing
Flush new and old systems in order to eliminate all foreign matter. Heavy scale, welding
splatter, and wire or other large foreign matter can clog the pump impeller. This reduces the
capacity of the pump which then causes cavitation, excessive vibration, and/or damage to
close clearance parts such as wear rings, seals, and sleeves.

Pre-operation inspections

NOTICE:
Foreign objects in the pumped liquid or piping system can block the flow and cause excess
heat generation, sparks and premature failure. Make sure that the pump and systems are free
of foreign objects before and during operation.

Perform these inspections before you start the pump:


• Check the alignment between the pump and motor.
See Coupling alignment in the Installation chapter for alignment requirements.
• Check all connections to the motor and starting device against the wiring diagram.
Check the voltage, phase, and frequency on the motor nameplate against the line circuit.
• Check the suction and discharge piping and the pressure gauges for proper operation.
• Check that you can turn the rotating element by hand in order to verify that it rotates freely.
• Check the stuffing box adjustment, lubrication, and piping.
• Check the driver lubrication.
Refer to the driver Installation, Operation, and Maintenance manual.

34 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

• Check that the pump bearings are properly lubricated.


• If the pump is oil lubrication, check that the oil level is correct prior to starting pump.
• If the pump is oil mist lubrication, check that the mist is flowing properly prior to starting
pump.
• Check that the coupling is properly lubricated, if required.
• Check that the pump is full of liquid and that all valves are properly set and operational,
with the discharge valve closed and the suction valve fully open. Purge all air from the top
of the casing.
• Check the direction of the rotation.
Be sure that the driver operates in the direction indicated by the arrow on the pump casing.
Serious damage can result if you operate the pump with the incorrect rotation. Check the
rotation each time you disconnect the motor leads.

Pump priming
CAUTION:
Do not run the pump dry.

When to prime the pump


You must prime the pump before startup. When it is possible, locate the pump below the fluid
level in order to facilitate priming and to ensure a steady flow of liquid. This condition provides a
positive suction head on the pump. It is also possible to prime the pump by pressurizing the
suction vessel.

Methods for pump priming


Pump installation Priming method
Positive head on the suction Open the suction valve and loosen the vent plug on top of the
casing. This allows air to be purged from the casing. While you
vent the air from the pump body, always rotate the pump shaft
a few times by hand.
Suction lift Priming must be done by other methods such as foot valves,
ejectors, or by manually filling the casing and suction line.

Fill the system


DANGER:
All openings (e.g. pipe connections, flanges) must be sealed off with proper fitting and material
prior to filling pump. Failure to plug all openings will result in personal injury.

1. Locate the vents at the highest point so that trapped gases and air can escape.
However, if the gases are flammable, toxic, or corrosive, then vent them to an appropriate
place in order to prevent harm to personnel or to other parts of the system.
2. Check the pipe hangers and anchors to make sure that they are properly set to take the
additional weight of the pumped fluid.
3. Close all of the drains.
4. Fill the system slowly so that excessive velocities do not cause rotation of the pumping
elements.
Rotation of the pumping elements can cause damage to the pump or its driver.
5. Check the adequacy of the anchors and hangers:
a) Mount a dial indicator off of any rigid structure not tied to the piping.

Model 3410 Installation, Operation, and Maintenance Manual 35


Commissioning, Startup, Operation, and Shutdown

b) Set the indicator button on the pump flange in the axial direction of the nozzle.
If the indicator moves as the filling proceeds, then the anchors and supports are not
adequate or are not set properly. Take corrective measures.

Start the pump


1. Close the drain valves.
2. Completely open all valves in the suction and discharge lines.
3. Turn on the seal water to the stuffing box.
These lines must always be left open if the pumped fluid is dirty or if there is the possibility
of air leaks.
4. Prime the pump.

NOTICE:
Make sure that the pump is properly primed. If it is not, then shut down the pump and
correct the condition.

5. Start the pump driver.


Turbines and engines can require a brief warm-up period. Consult the instructions provided
by the engine manufacturer.
6. When the pump is operating at full speed, make sure that the check valve has opened.
The check valve must open five seconds or less after startup in order to prevent damage to
the pump by operating at zero flow.
7. Adjust the liquid seal valves to produce the recommended pressure for either the
mechanical seal or the packed stuffing box.

Operational checklist
Check Explanation/comment Checked
Driver rotation Check the rotation each time the motor leads are discon-
nected.

WARNING:
Check the rotation of the power unit
and pump in relation to that of the
drive as shown by the arrows on
the case. Rotate the drive manually
before you apply power-checking
rotation. Do not operate in the re-
verse direction of these arrows as
serious damage or injury can occur.

Stuffing box adjustment Make stuffing box packing gland and lubrication adjust-
ments.
Flow It is difficult to accurately measure flow rate (volume/
time). Any of the following methods of measuring can be
used:
• Venturi meters
• Flow nozzles
• Orifice plates
• Timing the draw down in the wet well
Record any reading for future reference.

36 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

Check Explanation/comment Checked


Pressure Check and record both suction and discharge pressure
gauge readings for future reference. Also record the
following:
• Voltage
• Amperage per phase
• Kilowatts (if an indicating wattmeter is available)
• Pump speed
Temperature Check and record bearing temperatures using a
thermometer. The temperature should not exceed 180°F
(82°C).
Vibration and sound The acceptable vibration level of a centrifugal pump
depends on the rigidity of the pump and the supporting
structure. Recommended values for vibration can vary
between 0.20–0.60 ips (inches per second) velocity
depending on the operating characteristics and the
structure. Refer to the Centrifugal Pump section of the
Hydraulic Institute Standards for a complete description
and charts on various pumps.
Field sound levels are difficult to measure because of
background noise from piping, valves, drivers, gears,
and other parts. Follow the recommendations in the
Hydraulic Institute Standards.

Check the rotation - Frame Mounted


WARNING:
• Starting the pump in reverse rotation can result in the contact of metal parts, heat
generation, and breach of containment. Ensure correct driver settings prior to starting any
pump.
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM)
for specific instructions and recommendations.

1. Lock out power to the driver.


2. Make sure that the coupling hubs are fastened securely to the shafts.
3. Make sure that the coupling spacer is removed.
The pump ships with the coupling spacer removed.
4. Unlock power to the driver.
5. Make sure that everyone is clear, and then jog the driver long enough to determine that the
direction of rotation corresponds to the arrow on the pump.
6. Lock out power to the driver.

Model 3410 Installation, Operation, and Maintenance Manual 37


Commissioning, Startup, Operation, and Shutdown

Couple the pump and driver


WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury or death.
Always disconnect and lock out power to the driver before performing any installation or
maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for
specific instructions and recommendations.

CAUTION:
• You must use a coupling guard made of a spark-resistant material in an ATEX classified
environment.
• Running a pump without safety devices exposes operators to risk of serious personal
injury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.

Couplings must have proper certification to be used in an ATEX classified environment. Use
the instructions from the coupling manufacturer in order to lubricate and install the coupling.
Refer to driver/coupling/gear manufacturers IOM for specific instructions and recommenda-
tions.

Bearing lubrication
CAUTION:
• Risk of explosive hazard and premature failure from sparks and heat generation.
Ensure bearings are properly lubricated prior to startup.
• Risk of heat generation, sparks and premature failure. Do not insulate bearing housings.

Lubricate the bearings with grease


Grease-lubricated pumps can be identified by grease fittings located on bearing housing.
Sufficient lubricant is inserted at the factory for 2,000 hours of operation. See the Maintenance
chapter for grease lubrication instructions.

Lubricate the bearings with oil (optional)


NOTICE:
• The bar must be adjusted as stated in this procedure. Otherwise, the bearing will not be
lubricated.
• Do not fill the oil reservoir of the bearing frame through the plug at the top.

Oil-lubricated pumps are not lubricated at factory. Use a high quality, turbine-type oil with rust
and oxidation inhibitors. Constant level oilers are supplied in the box of fittings that
accompanies most oil-lubricated pumps. Make oil adjustments before lubrication. See
Lubricating-oil requirements (page 54) for recommended lubricants and supplies.
Bearing cooling is available with the oil lubrication option only. Cooling water must be
connected to the bearing housing with a waste or return line. Water cooling is required when
operating temperatures exceed 250°F (121°C).

38 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

1. Remove the oiler.

1. Oiler
2. Adjustment assembly
3. Housing
2. Remove the adjustment assembly from the oiler.
3. Adjust the bars to dimension A as specified in Bar adjustment (page 39).
4. Lock in position.
5. Replace the adjustment assembly in the oiler.
6. Install the oiler.
7. Fill each bottle with oil and replace in the oiler housing.
The oil reservoir in the bearing housing is filled when the oil remains visible in the bottle.
You will need to fill the bottle several times.

Bar adjustment
Specification Measurement
Dimension A 9/16 in. (14.5 mm)
Dimension B 1/2 in. (13 mm)
Oiler size #5 8 oz (204 ml)
Casing capacity • S and M groups: 9 oz (266 ml)
• L and XL groups: 16.5 oz (489 ml)

Seal the shaft with a packed stuffing box


NOTICE:
Packed stuffing boxes are not allowed in an ATEX-classified environment.

1. Make sure the stuffing box is clean and contains no foreign material.
2. Install the gland studs into the casing if they are not already installed.
The stuffing box packing is furnished in the box of fittings that accompanies the pump.
When you are packing the stuffing box, use the following order for the packing and lantern
rings:
1. Two packing rings
2. Lantern ring

Model 3410 Installation, Operation, and Maintenance Manual 39


Commissioning, Startup, Operation, and Shutdown

3. Last three packing rings

1. Lantern ring flush connection


2. Two-piece, investment-cast 316 SS plain gland (non-quench)
3. Stuffing box bushing
3. Twist the packing ring sideways just enough to get it around the shaft or sleeve.

Figure 25: Packing rings


4. Twist the lantern ring halves just enough to get them around the shaft sleeve.
Two pieces make one ring. The notches must face each another but do not need to be
aligned.

Figure 26: Lantern rings


5. Install the packing and lantern ring in the proper sequence.
Each ring must be installed separately.
a) Firmly seat each ring.
b) Use the stuffing box gland to push the packing and lantern ring into the stuffing box.

40 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

c) Stagger the joints in each ring by 90 degrees.


Make sure the center of the lantern ring lines up with the flush tap in the stuffing box.
Any extra rings are spares.

1. Gland
2. packing
6. Hand-tighten the gland nuts evenly but not tight.
7. To remove the packing from the stuffing box, do the following:
a) Remove the gland assembly.
b) Remove the packing with a packing hook.
c) Remove the lantern ring by inserting a wire hook into the ring on the outer edge.
d) Clean the stuffing box.
An alternate method of removing the packing is to remove the upper-half casing (see the
Maintenance chapter). Remove the packing and lantern ring, and then inspect the sleeves
or the shaft. Replace the sleeves or the shaft if either is deeply grooved.

Mechanical seal options


NOTICE:
Mechanical seals used in an ATEX classified environment must be properly certified. Failure to
ensure this may result in equipment damage or physical injury.

When mechanical seals are furnished, the description and identification are indicated on the
order forms. Installation drawings from the seal manufacturer are attached to pump. Most seals
are installed and adjusted at the factory. File these drawings for future use in maintenance and
adjustment of the seal whenever the pump is disassembled.

Prepare the seal for operation


To properly prepare the seal for operation, various cooling and flushing flows may have to be
connected. In some cases, these flows are recirculated from pump casing. In other cases,
liquid from an outside source may be used. Connect cooling and flushing flows to the seal as
directed in instructions supplied by the manufacturer.
All Model 3410 mechanical seals use O-ring mounted stationary seats and a flush gland with a
pilot fit in the ID of the stuffing box as standard. All S group pumps are standard without shaft
sleeves; sleeves are optional. M, L, and XL groups are standard with shaft sleeves and sleeve
nuts.

Model 3410 Installation, Operation, and Maintenance Manual 41


Commissioning, Startup, Operation, and Shutdown

Single inside unbalanced or integrally balanced seals


The following figure illustrates a single inside unbalanced or integrally balanced (metal bellows)
seal for an S group pump. This design incorporates the standard 420SS sleeveless shaft and
oversized stuffing box bore. The stuffing box bore is used to pilot the standard gland.

1. Sleeveless 420SS shaft


2. Oversize stuffing box bore
3. ID pilot fit in stuffing box
4. Standard two-bolt flush gland (cast iron or bronze)
5. O-ring mounted stationary seat
Figure 27: Single inside unbalanced or integrally balanced seal for an S group pump
The following figure illustrates the same type of seal for M group pumps. Note that the shaft is
protected by sleeves and sleeve nuts as standard. All other features and details are the same.

1. Standard shaft sleeve


2. Oversize stuffing box bore
3. ID pilot fit in stuffing box
4. Standard two-bolt flush gland (cast iron or bronze)
5. O-ring mounted stationary seat
Figure 28: Single inside unbalanced or integrally balanced seal for an M group pump

Conventional balanced seals


Conventional balanced seals require a stepped shaft sleeve. The following figure shows an S
group pump with a stub sleeve to accomplish the seal balancing.

42 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

1. Stub sleeve
2. ID pilot fit in stuffing box
3. Standard flush gland with O-ring mounted stationary seat
Figure 29: S group pump — stub sleeve
The following figure illustrates a standard stepped sleeve used on the M group pumps to
reduce the mounting diameter down to the standard sleeve nut OD.

1. Standard stuffing box bore


2. Non-piloting gland requiring feeler gauge centering on the shaft
Figure 30: M group pump — stepped sleeve
Bellows-type mechanical seals are integrally balanced and do not require a step in the sleeve.
They can be mounted directly on the sleeveless S group shaft or on a standard, non-balanced
M group sleeve.

Packing converted to a mechanical seal


Pumps that are supplied with packing boxes can be converted to mechanical seals in the field.
This conversion requires remachining the stuffing box to allow for the standard gland pilot
feature or remachining the standard gland to remove the pilot lip as shown in the following
figures. In this case, a shimming operation is required to center the gland on the shaft.
The following figure illustrates a single inside unbalanced mechanical seal mounted in the S
group standard stuffing box. Note that the pilot lip has been machined off the gland since there
is inadequate room in the bore for the pilot. With this arrangement, it is necessary to use a
feeler gauge or shims to center the gland on the shaft.

Model 3410 Installation, Operation, and Maintenance Manual 43


Commissioning, Startup, Operation, and Shutdown

1. Standard stuffing box bore


2. Non-piloting gland requiring feeler gauge centering on the shaft
Figure 31: S group pump – single inside unbalanced seal
The following figure illustrates a bellows-type balanced mechanical seal mounted in an S group
standard stuffing box. There is inadequate room in the standard stuffing box to mount a
conventional balanced seal requiring a stepped shaft sleeve. Use of these seals requires
remachining of the stuffing box bores.

1. Standard stuffing box bore


2. Non-piloting gland requiring feeler gauge centering on the shaft
Figure 32: S group pump — bellows-type seal
The following mechanical seals can be installed in standard stuffing boxes by using a
remachined, non-pilot gland:
• Crane type 1, 81T, 9T, and Metal Bellows (680)
• Flowserve RO

Mechanical seal converted to packing


Pumps supplied with mechanical seals can be converted to packing. The packing conversion
kit includes all the standard stuffing box fittings plus a liner sleeve that presses into the oversize
stuffing box bore.

44 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

1. Stuffing box bushing


2. Liner sleeve in oversize stuffing box bore
3. Standard packed box gland
Figure 33: Convert to packing

Connection of sealing liquid for a packed stuffing box


NOTICE:
Make sure to lubricate the packing. Failure to do so may result in shortening the life of the
packing and the pump.

You must use an external sealing liquid under these conditions:


• The pumped fluid includes abrasive particles.
• The stuffing-box pressure is below atmospheric pressure when the pump is running with a
suction lift or when the suction source is in a vacuum. Under these conditions, packing is
not cooled and lubricated and air is drawn into pump.

Conditions for application of an external liquid


Condition Action
The stuffing box pressure is above atmospheric Normal gland leaks of 40 to 60 drops per minute is
pressure and the pumped fluid is clean. usually sufficient to lubricate and cool the packing.
You do not need sealing liquid.
The stuffing box pressure is below atmospheric An outside source of clean compatible liquid is
pressure or the pumped fluid is not clean. required.
An outside source of clean compatible liquid is You must connect the piping to the lantern ring
required. connection with a 40 to 60 drops-per-minute leak
rate. The pressure must be 1.01 kg/cm2 | 15 psi
above the stuffing box pressure.

Connection of cooling water piping


Tapped openings on top of the quench gland are provided for water sealing. Bypass piping is
connected from a T-shaped joint installed in the vent plug opening at the top of the upper
casing to the tapped opening in the stuffing box.

Model 3410 Installation, Operation, and Maintenance Manual 45


Commissioning, Startup, Operation, and Shutdown

Mechanical seal flushing and cooling


NOTICE:
• The mechanical seal must have an appropriate seal-flush system. Failure to do so will
result in excess heat generation and seal failure.
• Sealing systems that are not self-purging or self-venting, such as plan 23, require
manual venting prior to operation. Failure to do so will result in excess heat generation and
seal failure.

A liquid film is required between the seal faces for proper lubrication. If the liquid flashes to
vapor, then the faces will run dry and become damaged. This requires that the liquid be cooled
so that vapor pressure is well below stuffing box pressure. Consult with ITT Goulds for a
recommendation if there is any uncertainty. Refer to the drawing supplied by the seal
manufacturer for the location of the taps. You can use the following methods to flush and cool
the seal:
Cool liquid flushing Description
method
External source A clean, cool, compatible liquid is injected from an outside source directly into
the seal gland. Flushing liquid must be at a pressure 5–15 psi (0.34–1.03 bar)
greater than the pressure in the stuffing box. You must inject 1.5–2 gpm (2–8
lpm). You can install a control valve and rotometer in the inlet line for accurate
regulation.
Product cooling Pumped liquid is piped from the pump casing, is cooled in an external heat
exchanger, and is injected into the seal gland. You can install a control valve
and rotometer in the inlet line for accurate regulation.

Other piping plans are available.

Connection of drain piping


Tapped openings around the stuffing box for draining leakage are optional. Check the
assembly dimension print for size and location. Check the rotor for free turning.

WARNING:
Explosion risk. Rubbing could lead to excess heat generation and sparks. Rotate the shaft by
hand to make sure it rotates smoothly and that there is no rubbing.

Pump priming
CAUTION:
Do not run the pump dry.

When to prime the pump


You must prime the pump before startup. When it is possible, locate the pump below the fluid
level in order to facilitate priming and to ensure a steady flow of liquid. This condition provides a
positive suction head on the pump. It is also possible to prime the pump by pressurizing the
suction vessel.

46 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

Methods for pump priming


Pump installation Priming method
Positive head on the suction Open the suction valve and loosen the vent plug on top of the
casing. This allows air to be purged from the casing. While you
vent the air from the pump body, always rotate the pump shaft
a few times by hand.
Suction lift Priming must be done by other methods such as foot valves,
ejectors, or by manually filling the casing and suction line.

Start the pump


1. Close the drain valves.
2. Completely open all valves in the suction and discharge lines.
3. Turn on the seal water to the stuffing box.
These lines must always be left open if the pumped fluid is dirty or if there is the possibility
of air leaks.
4. Prime the pump.

NOTICE:
Make sure that the pump is properly primed. If it is not, then shut down the pump and
correct the condition.

5. Start the pump driver.


Turbines and engines can require a brief warm-up period. Consult the instructions provided
by the engine manufacturer.
6. When the pump is operating at full speed, make sure that the check valve has opened.
The check valve must open five seconds or less after startup in order to prevent damage to
the pump by operating at zero flow.
7. Adjust the liquid seal valves to produce the recommended pressure for either the
mechanical seal or the packed stuffing box.

Pump operation precautions


General considerations

Operation at reduced capacity

WARNING:
• Risk of breach of containment and equipment damage. Excessive vibration levels can
cause damage to bearings, stuffing box, seal chamber, and/or mechanical seal. Observe
pump for vibration levels, bearing temperature, and excessive noise. If normal levels are
exceeded, shut down and resolve.
• Risk of explosion and serious physical injury. Do not operate pump with blocked system
piping or with suction or discharge valves closed. This can result in rapid heating and
vaporization of pumpage.
• Risk of equipment damage and serious physical injury. Heat build-up can cause rotating
parts to score or seize. Observe pump for excessive heat build-up. If normal levels are
exceeded, shut down and resolve.

CAUTION:
• Avoid increased radial load. Failure to do so can cause stress on the shaft and bearings.

Model 3410 Installation, Operation, and Maintenance Manual 47


Commissioning, Startup, Operation, and Shutdown

NOTICE:
Cavitation can cause damage to the internal surfaces of the pump. Ensure net positive suction
head available (NPSHA) always exceeds NPSH required (NPSH3) as shown on the published
performance curve of the pump.

Operation under freezing conditions

NOTICE:
Do not expose an idle pump to freezing conditions. Drain all liquid that is inside the pump.
Failure to do so can cause liquid to freeze and damage the pump.

Operation at reduced head


On motor-driven pumps, the pump capacity increases with reduced head along with
horsepower consumption, so if the discharge head or pressure drops far below the rated point
for any length of time, then the motor should be watched for heating. If this condition is likely to
persist, then arrangements should be made either to manually or automatically throttle the
discharge valve to build up head to a safe point.

Operation with surge conditions


If a pump is installed with a quick-closing valve in the discharge line that closes when the pump
is running, then dangerous pressure surges can build up that can cause damage to the pump
or line. In this situation, you must provide a cushioning arrangement to protect the pumping
equipment.

Inspect the packed box after startup


Newly installed packing requires time to run in. During this period, frequent attention and
careful adjustments are necessary. Use the following instructions to adjust the stuffing box
gland while the pump is running at rated speed.
1. Draw the gland nuts up evenly and only 1/6 of a turn at a time.
Allow sufficient time between adjustments for the packing to adjust itself and for you to
observe the effect on leakage.
2. If any sign of heating is evident, then shut down the pump and allow the box to cool.
Several starts may be necessary before the box runs cool. Do not back off the gland nuts
on a hot box because this can result in leakage between the outer edge of the packing and
the stuffing box bore.

Inspect the mechanical seal after startup


NOTICE:
Never run the pump with a dry seal. Make sure that any flush cooling lines are operating
properly.

The mechanical seal is adjusted at the factory. If the seal leaks slightly when the pump is first
started, then allow a few hours of run-in for the seal to adjust itself.

48 Model 3410 Installation, Operation, and Maintenance Manual


Commissioning, Startup, Operation, and Shutdown

Shut down the pump


WARNING:
Precautions must be taken to prevent physical injury. The pump may handle hazardous and/or
toxic fluids. Proper personal protective equipment should be worn. Pumpage must be handled
and disposed of in conformance with applicable environmental regulations.

1. Slowly close the discharge valve.


2. Shut down and lock out the driver to prevent accidental rotation.

Model 3410 Installation, Operation, and Maintenance Manual 49


Commissioning, Startup, Operation, and Shutdown

Make the final alignment of the pump and driver


WARNING:
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM)
for specific instructions and recommendations.
• Misalignment can cause decreased performance, equipment damage, and even catas-
trophic failure of frame-mounted units leading to serious injury. Proper alignment is the
responsibility of the installer and the user of the unit. Check the alignment of all drive
components prior to operating the unit.
• Follow the coupling installation and operation procedures from the coupling manufactur-
er.

You must check the final alignment after the pump and driver are at operating temperature. For
initial alignment instructions, see the Installation chapter.
1. Run the unit under actual operating conditions for enough time to bring the pump, driver,
and associated system to operating temperature.
2. Shut down the pump and the driver.
3. Remove the coupling guard.
See Remove the coupling guard in the Maintenance chapter.
4. Check the alignment while the unit is still hot.
See Pump-to-driver alignment in the Installation chapter.
5. Reinstall the coupling guard.
6. Restart the pump and driver.

50 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Maintenance
Maintenance schedule
CAUTION:
Shorten the inspection intervals if the pumped liquid is abrasive or corrosive, or if the
environment is classified as potentially explosive.

NOTICE:
This timetable assumes that the unit has been constantly monitored after startup. Adjust the
timetable for any extreme or unusual applications or conditions.

Monthly inspections
Check the bearing temperature with a thermometer. Do not check the temperature by hand. If
the bearings are running over 180°F (82°C), then there is too much or too little lubricant.
If changing the lubricant or adjusting to the proper level does not correct the condition, then
disassemble and inspect the bearings.

Three-month inspections
Perform these tasks every three months:
• Check the oil on oil-lubricated units.
• Check the grease-lubricated bearings for saponification. This condition is usually caused
by the infiltration of water or other fluid. Saponification gives the grease a whitish color. If
this condition occurs, then wash out the bearings with a clean industrial solvent and
replace the grease with the proper type as recommended.

Six-month inspections
Perform these tasks every six months:
• Check the packing and replace if necessary. Use the grade recommended. Make sure the
seal cages are centered in the stuffing box at the entrance of the stuffing box piping
connection.
• Take vibration readings on the bearing housings. Compare the readings with the last set of
readings to check for possible pump component failure.
• Check the shaft or shaft sleeve for scoring. Scoring accelerates packing wear.
• Check the alignment of the pump and driver. Shim the units if necessary. If misalignment
reoccurs frequently, then inspect the entire piping system. Unbolt the piping at the suction
and discharge flanges to see if it springs away, which indicates strain on the casing.
Inspect all piping supports for soundness and effective support of load. Correct as
necessary.

Annual inspections
Perform these inspections one time each year:
• Remove the upper half of the casing. Inspect the pump thoroughly for wear. Order
replacement parts if necessary.
• Check the wear ring clearances. Replace the wear rings when clearances become three
times their normal clearance or when you observe a significant decrease in discharge
pressure for the same flow rate.
Refer to Radial clearances (page 65) for standard clearances.
• Remove any deposit or scaling.

Model 3410 Installation, Operation, and Maintenance Manual 51


Maintenance

• Clean out the stuffing box piping.


• Measure the total dynamic suction and discharge head in order to test pump performance
and pipe condition. Record the figures and compare them with the figures of the last test.
This is especially important where the pumped liquid tends to form a deposit on internal
surfaces.
• Inspect foot valves and check valves. A faulty foot or check valve will cause poor
performance. The check valve safeguards against water hammer when the pump stops.

Flood-damaged pumps
If the pump is properly sealed at all joints and connected to both suction and discharge, then it
will exclude outside liquid. Therefore, it is only necessary to service the bearings, stuffing box,
and coupling after flood damage.
Perform the following service on a centrifugal pump after a flooded condition:
• Dismantle the frame, and then inspect the bearings for any rusted or badly worn surfaces.
Clean as necessary. If the bearings are free from rust and wear, then reassemble and
relubricate them with one of the recommended lubricants. Depending on the length of time
the pump has remained in the flooded area, it is unlikely that bearing replacement is
necessary. Only replace the bearings if rust or worn surfaces appear.
• Inspect the stuffing box and clean out any foreign matter that will clog the box. Replace
packing that appears to be worn or no longer regulates leakage properly. Clean and
thoroughly flush mechanical seals.
• Dismantle and thoroughly clean the couplings. Lubricate the couplings where required with
one of the lubricants recommended by the coupling manufacturer.

Bearing maintenance
These bearing lubrication sections list different temperatures of the pumped fluid. If the
pump is ATEX-certified and the temperature of the pumped fluid exceeds the permitted
temperature values, then consult your ITT representative.

Regrease the grease-lubricated bearings


CAUTION:
Grease-lubricated bearings are lubricated at the factory. Do not grease too frequently.

NOTICE:
Risk of equipment damage. Ensure that the grease container, the greasing device, and the
fittings are clean. Failure to do so can result in impurities entering the bearing housing while
regreasing the bearings.

52 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

1. Relief plug
2. Fitting
Figure 34: Grease lubricated bearings
1. Wipe dirt from the grease fittings.
2. Remove the two grease-relief plugs on the bearing housings.
3. Fill both of the grease cavities through the fittings with a recommended grease until the
fresh grease comes out of the relief holes.
4. Run the pump for about 30 minutes or until grease no longer comes out of the housing.
5. Reinstall the grease-relief plugs.
6. Wipe off any excess grease.
7. Recheck the alignment.
The bearing temperature usually rises after you regrease due to an excess supply of grease.
Temperatures return to normal in about two to four operating hours as the pump runs and
purges the excess grease from the bearings.
Lubricating-grease requirements
Grease-lubricated ball bearings are standard on this model. A grease-lubricated bearing can be
identified by grease fittings located on the bearing housing.

Precautions

NOTICE:
• Avoid equipment damage or decreased performance. Never mix greases of different
consistencies (NLGI 1 or 3 with NLGI 2) or with different thickeners. For example, never
mix a lithium-based grease with a polyurea based grease. If it is necessary to change the
grease type or consistency, remove the rotor and old grease from the housing before
regreasing.
• Remove the bearings and old grease if you need to change the grease type or
consistency. Failure to do so may result in equipment damage or decreased performance.

Recommended grease types


• Mobilux EP No. 2
• Texaco Multifak EP-2
• ShellAlvania EP-2

Requirements
Keep the following points in mind when lubricating with grease:
• Grease must be of sodium or lithium base with a NLGI-2 consistency. Do not use graphite.
• Greases made from animal or vegetable oils are not recommended due to the danger of
deterioration and forming of acid.

Model 3410 Installation, Operation, and Maintenance Manual 53


Maintenance

• Additional or replacement lubricant must be added after 2,000 hours or at three-month


intervals.
• Replace the lubricant in the housings at least once annually. This must be done when an
overhaul is made.
• When greasing anti-friction bearings, do not use high-pressure equipment. High pressure
can damage the bearings or seals, cause unnecessary loss of grease, create a danger of
overheating due to over greasing, and produce unsightly conditions around the bearing.
• Excess grease is the most common cause of overheating. Maintain the grease level at
about the capacity of the bearing and 1/3 to 1/2 of the cavity between the bearing and
grease fitting. Any greater amount will be discharged by the seal or vent.

Lubricate the oil-lubricated bearings


Oil-lubricated ball bearings are optional. Oil-lubricated pumps are supplied with oilers that
maintain a constant oil level in the bearing housing.
For an illustration of the oiler, see Lubricate the bearings with oil (optional) (page 38).
1. After the pump has been installed, flush the housings to remove dirt, grit, and other
impurities that have entered the bearing housing during shipment or installation.
2. Fill the oiler bottles on both bearing housings with the proper lubricant and place on the
oiler housing.
The oil reservoir in the bearing housing is filled when a constant oil level remains in the
bottle. Several fillings of the bottle are required for initial lubrication. Never put oil into the
oiler housing without the use of the oiler bottle.
Lubricating-oil requirements
Oil requirements based on temperature
For the majority of operating conditions, bearing temperatures run between 49°C | 120°F and 82°C |
180°F, and you can use an oil of ISO viscosity grade 68 at 38°C | 100°F. If temperatures exceed 82°C |
180°F, refer to the table for temperature requirements.
Temperature Oil requirement
Bearing temperatures exceed 82°C | 180°F Use ISO viscosity grade 100. Bearing temperatures
are generally about 11°C | 20°F higher than bear-
ing-housing outer surface temperatures.
Pumped-fluid temperatures are extreme Refer to the factory or a lubrication expert.

Acceptable oil for lubricating bearings


Acceptable lubricants
Brand Lubricant type
Chevron GTS Oil 68
Exxon Teresstic EP 68
Mobil DTE 26 300 SSU @ 38°C | 100°F
Philips Mangus Oil 315
Shell -29-0°C | -20-32°F: Tellus Oil 23
0-65°C | 32-150°F: Tellus Oil 68
65-93°C | 150-200°F: Turbo Oil 150
Royal Purple SYNFILM ISO VG 68 Synthetic Lube
Texaco Below 26.7°C | 80°F: Regal Oil R&O-46 #10 weight
Above 26.7°C | 80°F (): Regal Oil R&O-46 #20
weight

Lubricate new bearings with oil for the first time


New bearings should be lubricated as described in Lubricate the bearings with oil (optional)
(page 38).

54 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Bearing temperatures
• Bearing temperatures up to 180°F (82°C) are normal. For accurate measurement, place a
contact-type thermometer against the bearing housing. Record the reading in a convenient
location for reference.
• The stability of the temperature, rather than the number of degrees, is the best indication
of normal operation. A sudden increase in temperature is an indication of danger and a
signal to investigate. Check the unit for abnormal hydraulic operation and unnecessary
loads, such as coupling misalignment. See Troubleshooting (page 70).
• Do not use the human hand as a thermometer. A temperature that feels hot to the hand
can vary from 120°F (49°C) to 130°F (54°C) depending upon the individual. Above this
temperature, the human hand can not accurately estimate temperature.

Bearing conditions
The life of a bearing can be drastically reduced if contaminated with even a small amount of
dust or dirt. All bearing assembly operations must be done in an environment that is as free of
dust as possible. All tools and hands must be kept clean.
If... Then...
New bearings need to be installed They must not be unwrapped, cleaned, or washed until just
before the time of installation.
Old bearings are contaminated They must be replaced. Washing bearings does not guarantee
cleanliness.
There is any question as to the condition It is always best to replace them. This may prevent an
of bearings unplanned shutdown. Check the bearing housing seals and
replace as required.

Clean contaminated bearings


If new bearings are not available and immediate reassembly is necessary, then contaminated
bearings can be cleaned using the following procedure.
1. Pour 1–2 quarts (0.9–1.9 liters) of clean, water-free kerosene into a clean pail.
2. Dip the bearings into the kerosene and agitate slowly.
3. Blow-dry the bearings with air that is clean, filtered, and compressed.
Hold the two races together but allow the inner race to rotate a few turns now and then to
dislodge the kerosene from the retainer pockets.
4. When the bearings are dry, oil the bearings immediately with a good grade of clean
machine oil to prevent corrosion or rust.

Emergency ball bearing replacement


If the outboard-end ball bearing needs replacement and it is not desirable to overhaul the entire
pump, then the bearing can be replaced without disassembling the entire pump. See the
Disassembly and Reassembly sections for details.

Coupling lubrication
Grid or gear-tooth couplings
Grid or gear-tooth couplings, such as Falk Grid Steelflex or Falk Crowned Tooth coupling, are
initially lubricated with Falk Long Term Grease (LTG) and do not require relubrication for up to
three years. If the coupling leaks grease or is exposed to extreme temperatures or excessive
moisture, then more frequent lubrication is required.
Use the grease recommendations from the coupling manufacturer for the best performance.

Flexible couplings
Flexible couplings, such as Wood’s Sure-Flex or Falk Torus coupling, provide smooth
transmission of power. There is no rubbing action of metal against rubber to cause wear.
Couplings are not affected by abrasives, dirt, or moisture. This eliminates the need for
lubrication or maintenance and provides clean and quiet performance.

Model 3410 Installation, Operation, and Maintenance Manual 55


Maintenance

If other types of couplings are used, then follow the maintenance instructions provided by the
coupling manufacturer.

Shaft-seal maintenance
Packed stuffing box maintenance
Check or instruction Explanation/comment
When starting a pump with fiber packing Never draw the gland to the point where the packing is
for the first time, make sure that the compressed too tightly and no leakage occurs. This will burn
packing is slightly loose without causing the packing, score the shaft sleeve, and prevent circulation of
an air leak. As the pump runs in, gradual- the liquid that cools the packing.
ly tighten the gland bolts evenly.
Turn the rotating element by hand. The stuffing box is improperly packed or adjusted if friction in
the box prevents turning the rotating element by hand. A
properly operated stuffing box runs lukewarm with a slow drip
of sealing liquid.
After the pump has been in operation for This indicates proper packing, shaft sleeve lubrication, and
some time and the packing is completely cooling.
run in, check that the stuffing box leaks at
the rate of 40–60 drops per minute. NOTICE:
Eccentricity of the shaft or sleeve through the packing can
result in excess leakage. Make sure that the parts are properly
centered.

Check the packing frequently and replace Six months is a reasonable expected life, depending on
as service indicates. operating conditions. Use a packing tool in order to remove all
old packing from the stuffing box. Never reuse old packing or
add new rings to old packing. Clean the stuffing box thorough-
ly before you install new packing.
Check the condition of the shaft or sleeve —
for possible scoring or eccentricity and
make replacements as necessary.
When placing new, non-asbestos pack- —
ing into the stuffing box, open the molded
rings sideways and push the joints into
the stuffing box first. Then install the rings
one at a time, making sure to seat each
ring firmly. Stagger the joints at a 90°
rotation from each preceding joint.

Mechanical seal maintenance


Keep in mind the following general rules regarding mechanical seal maintenance. Refer to the
instructions provided by the seal manufacturer for detailed information.
• Mechanical seals are precision products that must be treated with care. Use special care
when handling seals. Make sure that oil and parts are clean in order to prevent scratching
the finely lapped sealing faces. Even light scratches on these faces can result in leaky
seals.
• Mechanical seals typically require no adjustment or maintenance except for routine
replacement of worn or broken parts.
• A used mechanical seal should not be put back into service unless the sealing faces have
been replaced or relapped. Relapping is practical only for seals that are 2 in. (5.1 cm) or
larger.
For optimum seal life, always follow these precautions:
• Keep the seal faces as clean as possible.
• Keep the seal as cool as possible.
• Make sure the seal always has proper lubrication.
• If the seal is lubricated with filtered fluid, then clean the filter frequently.

56 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Disassembly
Disassembly precautions
WARNING:
• Risk of serious physical injury or death from rapid depressurization. Ensure pump is
isolated from system and pressure is relieved before disassembling pump, removing
plugs, opening vent or drain valves, or disconnecting piping.
• Risk of serious personal injury. Applying heat to impellers, propellers, or their retaining
devices can cause trapped liquid to rapidly expand and result in a violent explosion. This
manual clearly identifies accepted methods for disassembling units. These methods must
be adhered to. Never apply heat to aid in their removal unless explicitly stated in this
manual.
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM)
for specific instructions and recommendations.
• Handling heavy equipment poses a crush hazard. Use caution during handling and wear
appropriate Personal Protective Equipment (PPE, such as steel-toed shoes, gloves, etc.)
at all times.
• Precautions must be taken to prevent physical injury. The pump may handle hazardous
and/or toxic fluids. Proper personal protective equipment should be worn. Pumpage must
be handled and disposed of in conformance with applicable environmental regulations.
• Risk of serious personal injury from exposure to hazardous or toxic liquids. A small amount
of liquid will be present in certain areas like the seal chamber upon disassembly.

CAUTION:
• Avoid injury. Worn pump components can have sharp edges. Wear appropriate gloves
while handling these parts.

Drain the pump


1. Close the isolation valves on the suction and discharge sides of the pump.
You must drain the system if no valves are installed.
2. Open the drain valve.
Do not proceed until liquid stops coming out of the drain valve. If liquid continues to flow
from the drain valve, the isolation valves are not sealing properly and you must repair them
before you proceed.
3. Leave the drain valve open.
Do not close the drain valve until the reassembly is complete.
4. Drain the liquid from the piping and flush the pump if it is necessary.
5. Disconnect all auxiliary piping and tubing.
6. Remove the coupling guard.

Remove the coupling guard


1. Remove the nut, bolt, and washers from the slotted hole in the center of the coupling guard.

Model 3410 Installation, Operation, and Maintenance Manual 57


Maintenance

2. Slide the driver half of the coupling guard toward the pump.

1. Driver
2. Slide to remove
3. Remove the nut, bolt, and washers from the driver half of the coupling guard.
4. Remove the driver-side end plate.

1. End plate
2. Coupling guard half
3. Driver
5. Remove the driver half of the coupling guard:
a) Slightly spread the bottom apart.

58 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

b) Lift upwards.

1. Annular groove
2. Driver half of the coupling guard
3. Driver

1. Annular groove
2. Coupling guard half
3. Driver
6. Remove the remaining nut, bolt, and washers from the pump half of the coupling guard.
It is not necessary to remove the end plate from the pump side of the bearing housing. You
can access the bearing-housing tap bolts without removing this end plate if maintenance of
internal pump parts is necessary.
7. Remove the pump half of the coupling guard:
a) Slightly spread the bottom apart.

Model 3410 Installation, Operation, and Maintenance Manual 59


Maintenance

b) Lift upwards.

1. Coupling guard half


2. Annular groove
3. Pump end plate
4. Driver

Remove the rotating element


1. Disconnect the coupling.
2. If the unit is oil-lubricated, then remove the reservoir bottle and oil drain plugs from the
bottom of the bearing housings and drain the oil. Replace the plugs after draining.
3. Remove the glands from the casing.
• If the pump has packed stuffing boxes, then remove the nut from the stud, and then
remove the gland halves.
• If the pump has mechanical seals, then slide the glands toward the bearings.
Make sure to protect the lapped stationary seal faces from damage.
4. Remove the casing screws (426) and nuts (425), and then remove the dowel pins (469G).
5. Loosen the top half by doing one of the following:
Group Instructions
S Insert a prying tool into the parting slot and pry the upper-half of the casing
loose. Repeat on the other side as required.
M, L, XL Tighten the two jacking bolts (418) evenly until the seal is broken.

60 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Group Instructions
S group M, L, XL groups

1. 469G
2. 426
3. Parting slot 1. 426
2. 425
3. 418

6. Remove the upper casing using a sling and hoist or a lift and lifting lugs.

WARNING:
Never attempt to lift the entire pump using lifting lugs.

7. Remove and discard the gaskets.


8. Remove the screws (372U) from the bearing saddle.
9. Place the sling on the shaft (122), and then use a suitable hoist or lift to remove the rotating
element and place it on padded supports.
On pumps with mechanical seals, make sure that the casing rings (103) do not slip and
damage the seals.
10. Mark the coupling position on the shaft (122) and remove the coupling.
Use instructions from the coupling manufacturer in order to remove the coupling.

Remove the bearings


CAUTION:
Never use a hammer to drive the shaft through the bearings. Doing so can cause severe shaft
and bearing damage.

NOTICE:
Do not remove bearings from the shaft unless you need to replace them.

1. Remove the screws (371C) and slide the housings (134) off the bearings (168 and 112)
and the shaft (122).
Make sure not to damage the oil seal (332).
2. Using snap ring pliers in order to remove the retaining ring (361) from the thrust end of the
shaft.
3. Remove the bearings (168 and 112) with a bearing puller.
Group Instructions
S Use a two-jaw puller on the end cover (109). Use caution not to damage
the end cover.

Model 3410 Installation, Operation, and Maintenance Manual 61


Maintenance

Group Instructions
M, X, XL Use a split-jaw puller on the back of the bearing (168 and 112).

Make sure not to damage the bearings. If the bearing needs to be reinstalled, then protect it
from contamination by wrapping it in clean cloth or paper.
4. For L and XL groups only, remove the radial bearing spacer (443T).
5. Remove the gaskets (360), bearing end covers (109), and deflectors (123).
6. Remove the outboard seal (332) from the coupling-end bearing housing, and remove the
inboard seal (333) from each end cover (109).
You can discard the old bearings and gasket.

Remove the seals


1. Do one of the following:
• If the pump has mechanical seals, then slide the glands with the stationary seat in
place off the shaft. Make sure not to damage the lapped seal faces.
• If the pump has packed stuffing boxes, then remove the nuts (355), gland (107),
packing (106), lantern rings (105), and stuffing box bushings (125).
2. Slide the casing wear ring (103) off the impeller and shaft.
3. Remove the rotating portion of both seals.

Remove the shaft sleeve


NOTICE:
Do not remove the optional shaft sleeve on S group pumps unless you intend to replace it.

1. Remove the shaft sleeve as follows:


When you remove the sleeve (126), use a very fine emery cloth to smooth the shaft in order
to prevent binding.
Group Instructions
S 1. Loosen the sleeve (126) with low heat, approximately 350–400°F
(177–222°C). Use a temperature stick or other measuring device to
monitor the temperature.
2. Apply torque with a strap wrench.
3. Slide the sleeve carefully off the shaft.
M, L, XL 1. Loosen the setscrew (222B) on the sleeve nut (124).
2. Use a spanner or strap wrench to unscrew the sleeve nut (124).
3. Remove and discard the O-rings (497).
4. Carefully slide the sleeve (126) off the shaft.
5. Remove and discard the sleeve-to-impeller gasket (428) located on the
end of the sleeve nearest the impeller.

Remove the impeller


CAUTION:
Do not damage the impeller hub surface that is sealed by the sleeve gasket.

1. Do one of the following:


Group Instructions
S 1. Use snap ring pliers to remove the retaining rings (361H).
2. Drive or press the impeller (101) off the shaft.
3. Remove the key (178).
See the Retaining ring configuration in the Parts Listings and Cross-
sectional Drawings chapter for an illustration of the S group retaining ring
configuration.

62 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Group Instructions
M, L, XL 1. Draw a mark on the shaft to indicate the location of the impeller hub.
2. Drive or press the impeller (101) off the shaft.
3. Remove the key (178).

Preassembly inspections
O-rings
Inspect the O-rings (497) and replace them if damaged.

Wear rings
When hydraulic performance has substantially reduced, replace the casing wear rings.
The original radial clearance between the impeller and the casing wear rings is shown in Radial
clearances (page 65).

Impeller wear rings


If the unit has impeller wear rings (142) and it is necessary to replace the rings, then proceed
as specified in Replace impeller wear rings (page 64).

NOTICE:
If the impeller was supplied without wear rings and excessive wear has occurred, then wear
rings can be fitted in the field. The impeller must then be remachined. Contact your local ITT
representative for details.

Casing joint gasket


Inspect the parting gaskets (331). If they are torn or otherwise damaged, then cut a new gasket
of 1/32 in. (0.8 mm) non-asbestos material using the recommendations below. Use the upper
half of the casing as a template. Strike the face with a soft-face hammer. This will cut the
gasket against the edge of the casing. The gasket must cover the entire surface of the parting
flange, especially around the wear ring locks and stuffing box. Otherwise, internal leakage from
high to low pressure zones in the pump will occur.
The following gasket materials are recommended if pre-cut replacement gaskets are not
available:
• JM - 961
• Durable - Durlon
• Garlock Blue Guard 3000
• Armstrong - N8090
• Rodgers - D7031

Shaft
Check the shaft (122) for runout to make sure that it is not bent. Straighten or replace the shaft
as necessary. Bearing seats must be in perfect condition. Check keyways for burrs or foreign
matter.

Impeller
Check the impeller (101). Replace the impeller if any of the following conditions exist:
• Excessive erosion, especially on inlet vanes
• Deterioration of the gasket mating surface to the point that the gasket (428) cannot seal
properly
• Excessive erosion of surfaces
If the impeller diameter needs to be cut, then make sure that it is dynamically-balanced. Grind
the outside of the shrouds near the periphery in order to correct imbalance.

Model 3410 Installation, Operation, and Maintenance Manual 63


Maintenance

Shaft sleeve
The sleeve (126) surface in the stuffing box area must be smooth and free of grooves. If there
are grooves, replace the shaft sleeve. The O-ring groove in the end of the sleeve nut must be in
good condition. The impeller end of the sleeve must be in good condition to ensure that the
gasket (428) will seal properly. The original diametric clearance between the shaft sleeve and
the stuffing box bushing is 0.030–0.034" (0.76–0.86 mm). If this clearance has increased to
more than 0.050–0.060" (1.27–1.5 mm), then the sleeve, and possibly the stuffing box bushing,
must be replaced.

Bearings
Check ball bearings (112 and 168) for visible wear. Slowly turn the races and look for pits or
worn areas on the balls or raceways.
Hold the inner race and spin the outer race. If there are rasping noises or the bearing catches
or binds, then replace the bearing. If any wear on the race is apparent, then replace the
bearing.
Replace ball bearings that are worn, loose, rough, or noisy when rotated.

Seals
Check the seals (332 and 333) for wear, cracks, cuts, deformities, and signs of excessive
leakage. Check the thrust-bearing end cover (109A) for signs of leakage and damage. Check
the grease fittings (113) or oil breathers (113A) (oil option) for serviceability and replace as
required.

General
Clean all parts before reassembly. This is especially important at O-ring grooves, gasket
surfaces, mating surfaces, and bearing areas. Check that threads on dowels, screws, nuts,
studs, and all gasket surfaces are in good condition. Make sure the anti-rotation pins (445A)
are firmly pressed into the wear rings (103).
Refer to Bearing maintenance (page 52) for specific instructions on cleaning bearings.

Replace impeller wear rings


1. Remove the old rings:
a) Remove the three setscrews (320).
b) Pull the ring (142) off the impeller hub.
2. Clean the hub and press on a new ring (142).
3. Drill and tap three holes 120° (1,600 mils) apart with a 7/32-in. drill and a 1/4-in. 20NC tap
on each ring.
4. Insert the setscrews.
Make sure to use 5/16 in. x 1/4 in. cup point safety setscrews.
5. Tighten the screws and lightly upset the threads. Do not use the existing holes.

64 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Radial clearances
Radial clearance between the impeller and casing wear rings

1. Casing wear ring


2. Radial clearance
3. Impeller
Table 2: Radial clearances by material
Group Pump size Iron and bronze Steel
2 x 3-11
3 x 4-10
4 x 6-9
0.005–0.007 in. 0.009–0.011 in.
S 4 x 6-11
(0.013–0.018 mm) (0.022–0.028 mm)
4 x 6-11H
4 x 6-13
4 x 6-13H
4 x 6-15
6 x 8-11
6 x 8-14
6 x 8-14H 0.005–0.007 in. 0.009–0.011 in.
M
6 x 8-17 (0.013–0.018 mm) (0.022–0.028 mm)
8 x 10-11
8 x 10-12
8 x 10-14
6 x 8-22
0.005–0.007 in. 0.009–0.011 in.
6 x 10-17
(0.013–0.018 mm) (0.022–0.028 mm)
8 x 10-17
0.0055–0.0075 in. 0.010–0.012 in.
8 x 10-17H
(0.014–0.019 mm) (0.025–0.030 mm)
0.005–0.007 in. 0.009–0.011 in.
8 x 10-21
L (0.013–0.018 mm) (0.022–0.028 mm)
0.0055–0.0075 in.
10 x 12-12
(0.014–0.019 mm) 0.010–0.012 in.
0.005–0.007 in. (0.025–0.030 mm)
10 x 12-14
(0.013–0.018 mm)
0.0065–0.0085 in. 0.011–0.013 in.
10 x 12-17
(0.017–0.022 mm) (0.028–0.033 mm)

Model 3410 Installation, Operation, and Maintenance Manual 65


Maintenance

Group Pump size Iron and bronze Steel


10 x 12-12H 0.0055–0.0075 in. 0.010–0.012 in.
10 x 12-15 (0.014–0.019 mm) (0.025–0.030 mm)
XL
0.0065–0.0085 in. 0.011–0.013 in.
12 x 14-15
(0.017–0.022 mm) (0.028–0.033 mm)

Reassembly
Install the impeller
CAUTION:
Check for magnetism on the pump shaft and demagnetize the shaft if there is any
detectable magnetism. Magnetism attracts ferritic objects to the impeller, seal, and bearings
which can result in excessive heat generation, sparks, and premature failure.

NOTICE:
The impeller and wear-ring clearance setting procedures must be followed. Improperly
setting the clearance or not following any of the proper procedures can result in sparks,
unexpected heat generation, and equipment damage.

1. Insert the key (178) into the shaft (122).


2. Determine the correct positioning of the impeller (101) on the shaft (122).
Facing the coupling-end of shaft, determine the proper rotation of the unit.
3. For S group pumps, install the retaining ring (361H) in the inboard (coupling-end) retaining
groove.
4. Slide the impeller (101) on the shaft and drive the impeller flush with the retaining ring
(361H).
5. If you are reinstalling the shaft and impeller, then line up the impeller hub with the mark
made on the shaft during disassembly.
6. Install the shaft sleeve.
Pump group Instructions
S 1. Install the retaining ring so that the tapered side is facing the outboard
end of the shaft.
The inward pressure asserted by the double taper automatically centers
the impeller and eliminates lateral play.
The outboard (thrust-end) retaining ring groove and retaining ring (361H)
are tapered.
2. If the pump does not use the optional sleeve, then you are finished. If the
pump uses the optional sleeve, then continue to complete the following
steps.
3. Make sure that the shaft is free of dirt, grease, and bonding compounds.
4. Apply a thin coat of Loctite 635 or equivalent to the shaft sleeve area and
the inside of the sleeve.
5. Slide the sleeve on the outboard end of the shaft and seat the sleeve
firmly against the shaft shoulder.
M, L, XL 1. Place the sleeve-to-impeller gasket (428) on the impeller (101).
Make sure that the gasket is aligned with the key (178).
2. Slide the sleeve (126) onto the shaft.
3. Slide the O-rings (497) onto the shaft by stretching them over the
threaded end.
4. Using a spanner or strap wrench to tighten the sleeve nuts (124),
adjusting the impeller to approximate center.
Do not tighten the setscrew. You will need to adjust the impeller again
when the rotating element is placed in the casing.

7. Position the casing wear rings (103) on the impeller.


Make sure that the anti-rotation pins (445A) are seated firmly.

66 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Assemble the rotating element


1. Slide the stuffing box bushing (125) onto the shaft or sleeve.
Units with mechanical seals do not have a stuffing box bushing.
2. If the unit is equipped with mechanical seals, then install the seals at this time.
Refer to the instructions provided by the seal manufacturer for details.
3. Slide the deflectors (123), bearing end covers (109), and gaskets (360) onto the shaft.

Install the bearings


1. Apply a thin film of machine oil to the bearing seats on the shaft.
2.
NOTICE:
There are several methods you can use to install bearings. The recommended method is to
use an induction heater that heats and demagnetizes the bearings. Bearings can get hot
and can cause physical injury.

Start the bearings (112 and 168) onto the shaft by tapping the inner race with a hammer or
mallet.
Keep the bearing square at all times.
3. After the bearing is started on shaft, use a driving sleeve in order to press or drive the
bearing until it contacts the shoulder on the inboard side of the seal.
Make sure that the sleeve contacts only one inner race.
4. For the outboard (thrust) bearing, install a tapered bearing-retaining ring (361) in the
retaining ring groove on the outboard (thrust) end of the shaft (122).
5. Slide the bearing housings (134) over the bearings.
6. Tighten the screws (371C) in two stages:
a) Using an X pattern, tighten the screws to 8 ft-lbs (11 Nm).
b) Again, using an X pattern, tighten the screws to 12 ft-lbs (16.3 Nm).
c) Repeat these steps on the opposite side.

Install the rotating element


NOTICE:
The impeller and wear-ring clearance setting procedures must be followed. Improperly
setting the clearance or not following any of the proper procedures can result in sparks,
unexpected heat generation, and equipment damage.

1. Install the rotating element in the lower casing with a sling, adequate hoist, or lift.
Make sure that the casing wear ring (103) and anti-rotation pins (445A) seat properly in the
wear ring grooves and pin grooves.
2. Tighten or loosen the sleeve nuts with a strap wrench as required in order to center the
impeller in the seated wear rings.
For M, L, and XL groups, tighten the sleeve nuts (124) to 30 ft-lbs (40.7 Nm).
3. Tighten the sleeve nut setscrews (222B).
Make sure that the stuffing box bushings (125) are aligned properly in the stuffing boxes.
4. Tighten the bearing housing to the lower casing on each side.
a) Install and tighten the screws (372U) until snug.
b) Tighten the screws on each side to 40 ft-lbs (55 Nm).
c) Tighten each side to 59 ft-lbs (80 Nm).

Assemble the casing


Make sure that the mating surfaces on the upper and lower halves of the casing are clean.
1. Install the gasket (351).
2. Carefully align and install the upper casing using a hoist, lift, and sling attached to lifting
lugs on the upper casing.

Model 3410 Installation, Operation, and Maintenance Manual 67


Maintenance

3. Install the dowel pins (496G).


4. Install the screws (426) and parting nuts (425) on the studs (356A) and tighten as follows:
a) Using an X pattern working outwards towards the flanges, tighten the nuts and screws
to the following torque:
• S and M groups: 40 ft-lbs (55 Nm)
• L and XL groups: 60 ft-lbs (80 Nm)
b) Using the same pattern, increase the torque to the following:
• S and M groups: 90 ft-lbs (122 Nm)
• L and XL groups: 180 ft-lbs (245 Nm)
c) Using the same pattern, tighten again to the following torque:
• S and M groups: 105 ft-lbs (142 Nm)
• L and XL groups: 255 ft-lbs (345 Nm)
d) Recheck the torque on each nut and screw.

Complete the assembly


1. Install the stuffing box packing (106) and lantern rings (105).
See Seal the shaft with a packed stuffing box (page 39).
2. Install the stuffing box gland (107) and nuts (355).
Make sure to only finger-tighten the nuts.
3. Adjust the glands.
4. Install the oiler (251) and drain plugs if they were removed.
Perform the following as required:
1. Lubricate the bearings.
2. Align the pump and driver.
3. Connect the coupling.
4. Replace the coupling guard.
5. Replace the sealing liquid.
6. Replace the cooling water piping.
7. Prime the pump.
8. Inspect after starting.
9. Check the stuffing boxes.

Bolt Torque Values - 3410 IOM


Table 3: Bolt Torque Values - FT-lb. (N-m)
Dry Threads Lub. Threads Dry Threads Lub. Threads
Sizes
2210 2210 2239 2239
3/8" 12 (16) 6 (8) 36 (48) 18 (24)
7/16" 20 (28) 10 (14) 58 (78) 29 (39)
1/2" 30 (41) 15 (20) 90 (122) 44 (60)
9/16" 44 (60) 22 (30) 126 (170) 63 (85)
5/8" 60 (81) 30 (41) 175 (237) 87 (118)
3/4" 105 (142) 53 (72) 305 (414) 154 (209)
7/8" 170 (231) 85 (115) 495 (671) 248 (336)
1" 255 (346) 128 (174) 740 (1003) 371 (503)

Spare parts
Critical service spare parts
ITT recommends that you have spare parts available to insure against possible long and costly
downtime periods, especially on critical services.

68 Model 3410 Installation, Operation, and Maintenance Manual


Maintenance

Part Notes
Rotating element This is a group of assembled parts including a shaft,
impeller, bearings, bearing housings with seals, wear rings,
stuffing box bushings, and all rotating parts except the
coupling.
Stuffing box packing and lantern ring (if any) One set for each stuffing box.
Mechanical seals (if any) One seal for each stuffing box.

Recommended spare parts


Alternately, you can have the spare parts available that are most likely to wear and can be used
as needed.
Part Notes
Stuffing box packing (if any) One seal for each stuffing box.
Mechanical seal (if any) -
Shaft sleeve (if any) -
Ball bearings One of each.
Wear rings For the casing and the impeller.
Shaft At least one is required.
Impeller key -
Stuffing box bushings (if any) -

Ordering parts
Repair orders will be handled with the minimum of delay if the following directions are followed:
• Specify the model number, pump size, and serial number. These can all be obtained from
the nameplate.
• List plainly the names, part numbers, and materials of the parts required. These names
and numbers must agree with those in the Parts list chapter of this manual.
• Specify the number of parts required.
• Specify definite billing and shipping instructions.

Model 3410 Installation, Operation, and Maintenance Manual 69


Troubleshooting

Troubleshooting
Troubleshooting
Symptom Cause Remedy
The pump is not deliver- The pump is not primed. Re-prime the pump and check that the pump and suction
ing liquid. line are full of liquid.
The pump has lost prime. Check for leaks in the suction pipe joints and fittings.
Vent the casing to remove accumulated air. Check the
mechanical seal or packing.
The impeller is clogged. Back-flush the pump in order to clean the impeller.
The impeller is loose on the shaft. Check the key, locknut, and setscrews.
The shaft is rotating in the wrong direction. Change the rotation. The rotation must match the arrow
on the bearing housing or pump casing.
The shaft is not rotating at all. Check the power, coupling, line shaft, and shaft keys.
The foot valve or suction pipe opening is Consult an ITT representative for the proper submersion
not submerged enough. depth. Use a baffle to eliminate vortices.
The suction lift is too high. Check for obstructions at the inlet and make sure the
suction valves are open. Check for pipe friction losses.
Use a vacuum or compound gauge to check the NPSH
available.
The motor speed is too low. Make sure that the motor wiring is correct and receives
full voltage or that the turbine receives full steam
pressure. The motor can have an open phase.
The system static head is too high. Check with ITT to determine whether a larger impeller
can be used. If not, then cut pipe losses, increase the
speed, or both. Do not overload the driver.
The system head or discharge head is too Check for pipe friction losses and that the valves are
high. wide open. The condition can be corrected with larger
piping.

70 Model 3410 Installation, Operation, and Maintenance Manual


Troubleshooting

Symptom Cause Remedy


The pump is not deliver- The suction piping has air leaks. Check the suction piping for air pockets and air leaks.
ing enough liquid or pres- The stuffing box has air leaks. Check the packing or seal and replace if necessary.
sure. Check for the proper amount of lubrication.
The motor speed is too low. Make sure that the motor wiring is correct and receives
full voltage or that the turbine receives full steam
pressure. The motor can have an open phase.
The discharge head is too high. Check for pipe friction losses and that the valves are
wide open. The condition can be corrected with larger
piping.
The suction lift is too high. Check for obstructions at the inlet and make sure the
suction valves are open. Check for pipe friction losses.
Use a vacuum or compound gauge to check the NPSH
available.
The impeller is clogged. Back-flush the pump in order to clean the impeller.
The amount of available NPSH is not 1. Increase the positive suction head by lowering the
sufficient. pump or increasing the suction pipe and fittings size.
2. Sub-cool the suction piping at the inlet to lower the
temperature of liquid that is entering the pump.
3. Pressurize the suction vessel.
The impeller or wear rings are worn or Inspect the impeller and wear rings and replace if any of
broken. the following conditions are present:
• The impeller or wear rings are damaged.
• The vane sections are severely eroded.
• The wear ring clearance is three times normal.
The foot valve is too small or partially Check the valve and replace with the correct size if
obstructed. necessary.
The suction inlet is not submersed deep If the inlet cannot be lowered or if the problem persists
enough. after the inlet is lowered, then chain a board to the
suction pipe. The board will be drawn into the eddies and
smother the vortex.
The shaft is rotating in the wrong direction. Change the rotation. The rotation must match the arrow
on the bearing housing or pump casing.
The system static head is too high. Check with ITT to determine whether a larger impeller
can be used. If not, then you can cut pipe losses,
increase the speed, or both. Do not overload the driver.
The mechanical seal is worn or broken. Repair or replace the seal as necessary.
The liquid passages are obstructed. Make sure that the suction and discharge valves are fully
open. Disassemble the pump and inspect the passages
and casing. Remove the obstruction.
Air or gases are trapped in the liquid. Consult with ITT.
The pump starts and then The suction lift is too high. Check for obstructions at the inlet and make sure the
stops pumping. suction valves are open. Check for pipe friction losses.
Use a vacuum or compound gauge to check the NPSH
available.
The impeller is clogged. Back-flush the pump in order to clean the impeller.
The suction piping has air leaks. Check the suction piping for air pockets and air leaks.
The stuffing box has air leaks. Check the packing or seal and replace if necessary.
Check for the proper amount of lubrication.
There is not enough suction head for hot or Consult with ITT about increasing the suction head.
volatile liquids.
The foot valve or suction pipe opening are Consult an ITT representative for the proper submersion
not submerged enough. depth. Use a baffle in order to eliminate vortices.
Air or gases are trapped in the liquid. Consult with ITT.
The casing gasket is damaged. Check the gaskets and replace if necessary.
The bearings are running The shaft is bent. Straighten the shaft or replace it if necessary.
hot. The bearings are worn out or improperly Inspect the bearings and replace them if necessary.
lubricated.
There is excessive pipe strain on the pump Relieve the strain and check the alignment. Consult ITT if
casing. necessary.
The pump and driver are not aligned Realign the pump and driver.
properly.
The lubrication has not been applied prop- Check the lubricant for suitability and level.
erly.
The lubrication is not cooled properly. Check the cooling system.

Model 3410 Installation, Operation, and Maintenance Manual 71


Troubleshooting

Symptom Cause Remedy


The pump is noisy or vi- The pump and driver are not aligned Realign the pump and driver.
brates. properly.
The impeller is partly clogged. Back-flush the pump to clean the impeller.
The impeller or shaft is broken or bent. Replace the impeller or shaft as necessary.
The foundation is not rigid. Tighten the hold-down bolts of the pump and motor or
adjust the stilts.
The bearings are worn. Replace the bearings.
Rotating parts are binding. Check the internal wearing parts for proper clearances.
The pump is cavitating. Locate and correct the system problem.
The pump leaks exces- The shaft is bent. Straighten the shaft or replace it if necessary.
sively at the stuffing box. The pump and driver are not aligned Realign the pump and driver.
properly.
The bearings are worn out or improperly Inspect the bearings and replace them if necessary.
lubricated.
The stuffing box is over- The stuffing box has air leaks. Check the packing or seal and replace if necessary.
heating. Check for the proper amount of lubrication.
The stuffing box is improperly packed. Check the packing and repack the stuffing box. If the
packing is too tight, then try releasing the gland pressure
and tightening again.
The incorrect packing or mechanical seal Consult with ITT.
has been installed.
The mechanical seal is damaged. Inspect and replace the mechanical seal as necessary.
Consult with ITT.
The shaft sleeve is scored. Machine or replace the shaft sleeve as necessary.
The packing is too tight or the mechanical Check and adjust the packing. Replace any parts as
seal is not adjusted properly. necessary. Adjust the mechanical seals. Consult the
instructions supplied by the seal manufacturer or consult
with ITT.
The motor requires ex- The discharge head has dropped below Install a throttle valve. If this does not help, then trim the
cessive power. the rated point and is pumping too much impeller diameter.
liquid. If this does not help, then consult an ITT representative.
The liquid is heavier than expected. Check the specific gravity and viscosity.
The shaft is rotating in the wrong direction. Change the rotation. The rotation must match the arrow
on the bearing housing or pump casing.
The impeller is damaged. Inspect the impeller and replace it if necessary.
Rotating parts are binding. Check the internal wearing parts for proper clearances.
The shaft is bent. Straighten the shaft or replace it if necessary.
The motor speed is too high. Check the motor voltage or the steam pressure received
by turbines. Make sure the motor speed matches the
speed on the nameplate.
The stuffing box is improperly packed. Check the packing and repack the stuffing box. If the
packing is too tight, then try releasing the gland pressure
and tightening again.
The bearings are worn out or improperly Inspect the bearings and replace them if necessary.
lubricated.
The running clearances between the wear Check for the proper clearances. Replace the casing or
rings are incorrect. impeller wear rings if necessary.
There is excessive pipe strain on the pump Relieve the strain and check the alignment. Consult ITT if
casing. necessary.
The amount of available NPSH is not 1. Increase the positive suction head by lowering the
sufficient. pump or increasing the suction pipe and fittings size.
2. Sub-cool the suction piping at the inlet to lower the
temperature of liquid that is entering the pump.
3. Pressurize the suction vessel.
The pump and driver are not aligned. Realign the pump and driver.
The suction inlet is not submersed deep If the inlet cannot be lowered or if the problem persists
enough. after the inlet is lowered, then chain a board to the
suction pipe. The board will be drawn into the eddies and
smother the vortex.
The casing is distorted due to excessive Check the alignment. Examine the pump for rubbing
strains from the suction and discharge between the impeller and the casing. Replace damaged
piping. parts and redo the piping.

72 Model 3410 Installation, Operation, and Maintenance Manual


Troubleshooting

Symptom Cause Remedy


The element turns hard or The shaft is bent. Straighten the shaft or replace it if necessary.
has a rub. The running clearances between the wear Check for the proper clearances. Replace the casing or
rings are incorrect. impeller wear rings if necessary.
There is excessive pipe strain on the pump Relieve the strain and check the alignment. Consult ITT if
casing. necessary.
There is excessive runout on the shaft or Inspect the rotating element and bearings. Replace worn
impeller rings. or damaged parts as necessary.
There is dirt in the casing ring or between Clean and inspect the wear rings. Replace worn or
the impeller and casing wear rings. damaged parts as necessary. Isolate and relieve the
source of dirt.

Model 3410 Installation, Operation, and Maintenance Manual 73


Parts Listings and Cross-Sectionals

Parts Listings and Cross-Sectionals


Drawings
Exploded view

74 Model 3410 Installation, Operation, and Maintenance Manual


Parts Listings and Cross-Sectionals

Retaining ring configuration

Parts list
Item Quantity per Part name Bronze-fitted All iron Iron/316 All 316SS
pump rotating
element
100 1 upper Casing 1003 - A743 CF-8M
1 lower
101 1 Impeller 1179 1000 316
102 2 Seal tubing (optional) Brass Steel 316
103 2 Casing wear ring 1618 1000 1071
105 2 Lantern ring Glass-filled Teflon
106 1 set Stuffing box packing Square non-asbestos (die-formed S and M groups)
107 2 Stuffing box gland AISI 316
109 2 Bearing end cover 1000
109A 1 Thrust bearing end cover Steel
112 1 Thrust ball bearing Steel
113 2 Grease fitting Steel
113A 2 Breather (oil lubrication only) Steel
122 1 Shaft AISI 4140
123 1 Deflector (optional) Laminated plastic
124 1 Sleeve nut (M, L, and XL only) 1618 1000 1071
125 2 Stuffing box bushing 316
126 2 Shaft sleeve (optional on S group) 1618 1000 316
134 2 Bearing housing 1000

Model 3410 Installation, Operation, and Maintenance Manual 75


Parts Listings and Cross-Sectionals

Item Quantity per Part name Bronze-fitted All iron Iron/316 All 316SS
pump rotating
element
142 2 Impeller wear ring 1618 1000 316
168 1 Coupling ball bearing Steel
178 1 Impeller key AISI 1018
222B 4 Sleeve nut setscrews Steel
250 2 Mechancial seal gland (Flush 1179 1003 1002 316
STD)
2 Mechanical seal gland (FL-VT- Steel
DR, optional)
251 2 Sight oiler (optional oil lubrication) White metal and glass
317 2 Thrust mechanical seal (optional) Steel
317A 1 Radial mechanical seal (optional) Steel
320 6 Retaining setscrew (for optional 303 SS
impeller wear ring)
332 1 Oil seal outboard grease Buna rubber
332A 1 Labyrinth seal outboard (optional) Steel
333 1 Oil seal - inboard, grease Buna rubber
333A 1 Labyrinth seal inboard (optional) Steel
351 1 Parting casing gasket 1/32 in. non-asbestos
353 4 Gland studs 316
353B 2 Hex capscrew with cast iron me- Steel
chanical seal gland
4 Hex capscrew with steel mechani- Steel
cal seal gland
355 4 Gland stud hex nut 304
356A 4 Casing parting stud Steel
360 2 Gasket, end cover to bearing Kraft paper
housing
360Q 8 Gasket, gland to case Non-asbestos
361 1 Thrust bearing retaining ring Steel
361H 2 Impeller retaining ring (S group Steel Stainless steel
only)
371C 8 Hex capscrew Steel
372U 4 Hex capscrew Steel
418 2 Hex capscrew (casing jacking) Steel
425 4 Parting hex nuts Steel
426 Varies Hex capscrew (parting) Steel
428 2 Gasket, sleeve to impeller (M, L, 1/32 in. non-asbestos
and XL only)
445A 2 Anti-rotation pin, casing wear ring AISI 420 AISI 316
469G 2 Tapered pin with hex nut Steel
494 2 Cooling assembly (optional) Fitting copper tube
497 2 Sleeve nut O-ring (M, L, and XL Buna rubber
only)

Materials of construction
Code Specification
1000 Cast iron - ASTM A48 Class 25B
1003 Cast iron - ASTM A48 Class 30B
1179 Bronze - ASTM B584-UNS C87600
304 Wrought stainless - ASTM A276, Type 304
AISI 1018 ASTM A108, Grade 1018 -B1112
AISI 420 ASTM A276, Type 420
AISI 4140 ASTM A322, Grade 4140
1618 Bronze -ASTM B584 Alloy C80500
1071 Nitronic 60 - ASTM A743 Grade CF10SMnN

76 Model 3410 Installation, Operation, and Maintenance Manual


Visit our website for the latest version of this
document and more information:
http://www.gouldspumps.com

ITT Goulds Pumps


240 Fall Street
Seneca Falls, NY 13148
USA

© 2016 ITT Corporation Form IOM-3410.en-US.2016-11


The original instruction is in English. All non-English instructions are translations of the original
instruction.

You might also like