Quick-Start Protocol February 2015

QIAprep® Spin Miniprep Kit


The QIAprep Spin Miniprep Kit (cat. nos. 27104 and 27106) can be stored at room
temperature (15–25°C) for up to 12 months.

For more information, please refer to the most recent version of the QIAprep Miniprep
Handbook, which can be found at: www.qiagen.com/handbooks.

For technical assistance, please call toll-free 00800-22-44-6000, or find regional phone
numbers at: www.qiagen.com/contact.

Notes before starting


 Optional: Add LyseBlue reagent to Buffer P1 at a ratio of 1 to 1000.
 Add the provided RNase A solution to Buffer P1, mix and store at 2–8°C.
 Add ethanol (96–100%) to Buffer PE before use (see bottle label for volume).
 All centrifugation steps are carried out at 13,000 rpm (~17,900 x g) in a conventional
table-top microcentrifuge.

1. Pellet 1–5 ml bacterial overnight culture by centrifugation at >8000 rpm (6800 x g) for 3
min at room temperature (15–25°C).
2. Resuspend pelleted bacterial cells in 250 μl Buffer P1 and transfer to a microcentrifuge
tube.
3. Add 250 μl Buffer P2 and mix thoroughly by inverting the tube 4–6 times until the
solution becomes clear. Do not allow the lysis reaction to proceed for
more than 5 min. If using LyseBlue reagent, the solution will turn blue.

Sample to Insight__
4. Add 350 μl Buffer N3 and mix immediately and thoroughly by inverting the tube 4–6
times. If using LyseBlue reagent, the solution will turn colorless.
5. Centrifuge for 10 min at 13,000 rpm (~17,900 x g) in a table-top microcentrifuge.
6. Apply 800 μl supernatant from step 5 to the QIAprep 2.0 spin column by pipetting. For
centrifuge processing, follow the instructions marked with a triangle (). For vacuum
manifold processing, follow the instructions marked with a circle ().  Centrifuge for
30–60 s and discard the flow-through, or  apply vacuum to the manifold to draw the
solution through the QIAprep 2.0 spin column and switch off the vacuum source.
7. Recommended: Wash the QIAprep 2.0 spin column by adding 0.5 ml Buffer PB. 
Centrifuge for 30–60 s and discard the flow-through, or  apply vacuum to the manifold
to draw the solution through the QIAprep 2.0 spin column and switch off the vacuum
source.
Note: This step is only required when using endA+ strains or other bacteria strains with
high nuclease activity or carbohydrate content.
8. Wash the QIAprep 2.0 spin column by adding 0.75 ml Buffer PE.  Centrifuge for
30–60 s and discard the flow-through, or  apply vacuum to the manifold to draw the
solution through the QIAprep 2.0 spin column and switch off the vacuum source. Transfer
the QIAprep 2.0 spin column to the collection tube.
9. Centrifuge for 1 min to remove residual wash buffer.
10. Place the QIAprep 2.0 column in a clean 1.5 ml microcentrifuge tube. To elute DNA,
add 50 μl Buffer EB (10 mM TrisCl, pH 8.5) or water to the center of the QIAprep 2.0
spin column, let stand for 1 min, and centrifuge for 1 min.
11. If the extracted DNA is to be analyzed on a gel, add 1 volume of Loading Dye to 5
volumes of purified DNA. Mix the solution by pipetting up and down before loading the
gel.