BJB3C 3fi Motor-Drive
BJB3C 3fi Motor-Drive
BJB3C 3fi Motor-Drive
WF:Step angle subdivision control signal-, When the signal is low, the motor is12800Step/Rpm.
COM+:Direction level+
UD:Direction level-
COM+:Pulse signal+
CP:Pulse signal-
PD: Reset signal. When powered, motor is locked (not appliedCPPulse, red) or running
(applyingCPPulse);
How to manually adjust the motor power and not close? Use this signal. When ON (active
low), the motor is in a free state; when OFF (active high) or not connected, cancels offline.
If you don't need this feature, do not connect this end.
COM+:versus PD Complete an offline signal together
AL: Alarm output signal
COM+,COM+,COM+ connected Inside.
All interfaces are 5V. If the PC port pulse output voltage is >5V, you need to insert
1K-...-4.7K to ensure the input current is in 15-30mA range.
Inappropriate R choice causes the noise to increase, forces motor out of step.
WF,UD,CP,PD are Active LOW