MACH-ProCom™

BACnet ®
Controller

Optimum form and function

With its extensive network routing


ability to multiple open protocols, and its
highly scalable I/O and small footprint,
the Reliable Controls® MACH-ProCom™
achieves an optimum balance between
form and function. This fully programmable,
Internet-connected, BACnet Building
Controller (B-BC) is ideal for large
mechanical rooms and multi-building
applications.

MPC
MACH-ProCom™
T ech S pecs F eatures O rdering

Processor Protocol 128 Control-BASIC™ MP-C


• 147 MHz, high-performance,32-bit • BACnet Programs • MACH-ProCom controller
embedded microcontroller -- B/IP x 2, Ethernet, MS/TP x 2, • User programmable control
Memory and PTP strategy in a readable, BASIC- Accessories
• 8 MB operating RAM • DHCP like language
• 3200 bytes per program
MP-DINRAIL
• 1 MB non-volatile RAM (trends and -- Dynamic Host Configuration
• Two-piece adapter kit to
dynamic values) Protocol Trend Logs mount controller onto 35
• 4 MB Flash EEPROM operating • Modbus • Each Trend Log stores up to 8 mm x 7.5 mm top hat DIN
system, database, and controller -- Supports both RTU and TCP points rail. DIN rail not included
configuration communications in slave • Values recorded at user-defined MPP-IO
Supply Voltages mode and master mode with intervals
up to 128 slave devices • MACH-ProPoint I/O
• 24 VAC ±10% 20 VA max. 50/60 Hz • Dynamically assigned expansion module with
• 24 VDC ±10% 4 W max. • SMTP Runtime Logs 12 universal inputs and 8
Communications -- Provides standard email • Totals the On time and records outputs
communications for the On/Off times of every binary MPP-IO-H
• IEEE 802.3 Ethernet 10/100 BaseT
broadcasting email alarms point
• 2 EIA-485 @ 76.8 kbps max. • MPP-IO with HOA (Hand/
-- Supports TLS/SSL security • Dynamically assigned Off/Auto) switches and
• 1 EIA-232 @ 115.2 kbps max. PC or
• SNMP 128 Variable Arrays potentiometer overrides
modem
-- Simple Network Management • Up to 128 elements in a one- for each output
• SMART-Net port @ 16 sensors max.
Protocol dimensional array MPP-IO-U
Expansion Modules
• SNTP 128 User Passwords • MACH-ProPoint I/O
• Up to 8 MACH-ProPoint expansion
-- Simple Network Time Protocol • Protects access to system expansion module with
modules
Inputs and Outputs 12 universal inputs and 8
Real-Time Clock • Each user is assigned a user
• Up to 8 MACH-ProPoint universal outputs
• ± 1 second per day name and an access level
expansion modules MPP-IO-U-H
Memory/RTC Backup Custom Units
• Maximum possible inputs of 192 • MPP-IO-U with HOA
• 72 hour backup • 8 analog engineering units
• Maximum possible outputs of (Hand/Off/Auto) switches
• 10 years for database • 8 binary units and potentiometer
128
Wiring Terminals • 8 multistate units with 8 states, overrides for each output
1024 Variables 30 characters each
• 12 to 22AWG (3.31 mm² to 0.33 mm²) MPP-IO-DL
• Selectable standard and custom SMART-Net™ Port
• Stranded or solid core ranges,as well as fixed program- • Door label sheet for MP-S,
• Networks up to 16 SMART- MP-S-H, MPW-S, MPW-
• Copper conductors only driven values
Sensors™ S-H, MPP-IO, MPP-IO-H,
Dimensions 128 PID Loops MPP-IO-U, and MPP-IO-
1536 Network In Points
• 15.2 cm L x 13.7 cm W x 3.9 cm H • Standard P, PI, or PID controllers U-H
for closed loop control
512 Network Out Points
(5 15/16" L x 5 3/8" W x 1 1/2" H) MPP-I
• The total maximum number
Mounting 128 Schedules • MPP Input expansion
of writes and shares to other
• #8 clearance holes on • 14 On/Off times for each devices module with 24 universal
12.7 cm L x 11.0 cm W weekday or exception inputs
Real-Time Clock
(5" L x 4 5/16" W) 32 Calendars MPP-I-DL
Warranty
• Screw depth 25 mm (1") • Days of the year designated as • Door label sheet for MPP-I
• 5 years
Weight holidays MPP-O
20 Custom Tables Certification
• 0.25 kg (0.6 lb.) • MACH-ProPoint Output
• BTL Listed (B-BC)
Ambient Limits • For creating custom scaling expansion module with 16
functions • UL 916 Listed
• Operating: -20 oC to 55 oC universal outputs
64 System Groups • FCC CFR 47 Part 15/B
(-4 oF to 131 oF) MPP-O-H
• Shipping: -40 °C to 60 °C • Allows related points to be • CE
• MPP-O with HOA (Hand/
(-40 °F to 140 °F) grouped onto one display Off/Auto) switches and
• Humidity: 10% to 90% • 160 points/group potentiometer overrides
RH non-condensing for each output
MPP-O-DL
• Door label sheet for
MPP-O
SS-RJ11TB-B,
SS-RJ11TB-C
• SMART-Net breakout
connector RJ-11 to
terminal block
SS-X
• SMART-Sensor Network
Expansion Board

MPC-23/02/16-TKB © 2007–2016 Reliable Controls ® Corporation. All rights reserved Designed and Manufactured in Canada
MACH-ProCom™
A pplication D iagram

PC or Modem

SMART-Sensor™ LCD

Internet Connected

Network to other controllers

MACH-ProZone™
Power 24 VAC/VDC

MACH-ProCom controller

Outputs Inputs

MPP-IO MPP-I MPP-I MPP-I

MPP-IO MPP-IO MPP-O MPP-O

Connect up to 8 MACH-ProPoint expansion modules of any mix with a maximum input count of 192, and a maximum output count of
128 per controller. Expansion modules are daisy-chained to the AUX-Net port of the controller in any combination.

MPC-23/02/16-TKB © 2007–2016 Reliable Controls ® Corporation. All rights reserved Designed and Manufactured in Canada