0% found this document useful (0 votes)
54 views2 pages

NAP Series: High-Voltage Pulses High-Attenuation Type

1. The document provides specifications for NAP series high-voltage pulse surge protectors, including models NAP-04 through NAP-30. 2. Key specifications include rated voltage of 250V AC/DC, rated currents from 4A to 30A, leakage currents from 0.5mA to 1mA max depending on model, and operating temperature range of -40 to 85 degrees C. 3. The units have push-down type terminal blocks and optional DIN rail installation, and are approved by safety standards in the US, Canada, Europe and ENEC.

Uploaded by

Saifudin Zuhri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views2 pages

NAP Series: High-Voltage Pulses High-Attenuation Type

1. The document provides specifications for NAP series high-voltage pulse surge protectors, including models NAP-04 through NAP-30. 2. Key specifications include rated voltage of 250V AC/DC, rated currents from 4A to 30A, leakage currents from 0.5mA to 1mA max depending on model, and operating temperature range of -40 to 85 degrees C. 3. The units have push-down type terminal blocks and optional DIN rail installation, and are approved by safety standards in the US, Canada, Europe and ENEC.

Uploaded by

Saifudin Zuhri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

High-voltage pulses high-attenuation type Ordering information

NAP series 1
NAP -10 -472
2 3 4
-O
1 Model Name
R
2 Rated Current
3 Line to ground capacitor code:See table 1.1.

table1.1 Line to ground capacitor code


Line to ground
Leakage Current
Code capacitor
(Input 125/250V 60Hz)
(nominal value)
000 5 A/ 10 A max Not Provided
101 12.5 A/ 25 A max 100pF
221 25 A/ 50 A max 220pF
331 37.5 A/ 75 A max 330pF
471 50 A/ 100 A max 470pF
681 75.5 A/ 150 A max 680pF
102 0.13 mA/ 0.25mA max 1000pF
222 0.25 mA/ 0.5 mA max 2200pF
332 0.38 mA/ 0.75mA max 3300pF
472 0.5 mA/ 1.0 mA max 4700pF
The terminal cover is retracted inside the unit DIN rail installation type is option
* When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4 Options
D :DIN rail installation type
* The dimensions change when the option is set.
Refer to External view.

Features of NAP series

High-voltage pulses high-attenuation type


- Single Phase 250 VAC
- Push down type terminal block

Specifications
No. Items NAP-04-472 NAP-06-472 NAP-10-472 NAP-16-472 NAP-20-472 NAP-30-472
1 Rated Voltage[V] AC 1f 250 / DC250
2 Rated Current[A] 4 6 10 16 20 30
3 Test Voltage (Terminal-Mounting Plate) 2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100MW min at room temperature and humidity
5 Leakage current 125/250V 60Hz 0.5mA/1.0mA max
6 Voltage drop 1.0V max
7 Safety agency approval temperatures -25 to +85C (Refer to Derating Curve)
8 Operating temperature -40 to +85C (Refer to Derating Curve)
9 Operating humidity 20 to 95%RH (Non condensing)
10 Storage temperature/humidity -40 to +85C/20 to 95%RH (Non condensing)
11 Vibration 10 to 55Hz, 19.6m/s2 (2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact 196.1m/s2 (20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
14 Case size (without projection) /Weight 53X41X92 mm [2.09X1.61X3.62 inches] (WXHXD) /300g max (Option : -D refer to external view)

Circuit Diagram Derating Curve

Case
100

80
Load Factor [%]

1 3 60
CY
LINE LOAD 40
CY 20
2 4
0
-40 -30 -20 40 50 55 60 70 80 90
Ambient Temperature [C]
CY : Line to ground capacitor : Mounting Plate

NA-4
NAH,NAC,NAM,NAP series
External view
As this product is adopted push-down type terminal block, this appearance is as follows.
1The terminal cover is retracted inside the unit.
2The screws for connecting the terminals are held in the up right position.

Standard Type
92
[3.62]
82 ±0.5 (2.5) 27
[3.23] [0.1] [1.06]
2-f4.8 2-Protection Earth
77 8
[0.19]
Mounting Hole [3.03] [0.31]

Input
Terminal

Output

45 ±0.5
[1.77]
Name Plate Terminal
[0.59]

[2.09]
15

53
[0.47]
Output

12
Input Terminal
Terminal

6-M4
Terminal cover Terminal cover Mounting Plate

[0.08]
(2)
¶ Closed the terminal cover
¶ Tolerance : ±1 [±0.04]
¶ Weight : 300g max
¶ Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]
[1.61]
41

¶ Case : PBT
¶ Dimensions in mm, [ ]=inches
¶ Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max

DIN rail installation Type


92 (11) (2.5) 27
[3.62] [0.43] [0.1] [1.06]
77 2-Protection Earth 8
[3.03] [0.31]

Input
Terminal

Output
Name Plate Terminal
[0.59]

[2.09]
15

53
[0.47]

Output
12

Input Terminal
Terminal

6-M4
Terminal cover Terminal cover Mounting Plate
[0.08]
(2)

¶ Closed the terminal cover

¶ Tolerance : ±1 [±0.04]
¶ Weight : 300g max
[1.61]
41

¶ Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]


¶ Case : PBT
¶ Dimensions in mm, [ ]=inches
[0.35]

¶ Terminal block screw tighting torque M4:1.6N-m (16.9kgf-cm) max


(9)

[0.28]
7

DIN rail

¡Note when installing the EMI/EMC


Filter on a DIN rail. DIN rail
When the EMI/EMC Filter is grounded through
the DIN rail, the proper noise attenuation may not Name Plate
be achieved.
Be sure to connect the protection earth (PE) of
the EMI/EMC Filter body to the earth.
It can connect the ground to either one only.

NA-5

You might also like